Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fast charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

A short account of thermoelectric film characterization techniques

Thermoelectric films and periodic structures have particularly intriguing electrical and thermal transport features due to their low dimensionality. As a result, they have piqued the attention of researchers from across the spectrum of disciplines. Their applications span from cooling fast CPUs to providing energy for wearable devices. The progress in the techniques for synthesizing TE materials and fabricating thin films has facilitated the emergence of a flourishing research domain in the field of electrical and thermal transport at the nanoscale. Further, a significant proportion of contemporary electronic, opto-electronic, and solar energy components are composed of materials featuring numerous interfaces and nanoscale contacts. Consequently, it is imperative to explore the thermal energy transfer and charge carrier transport across the films with thickness dimensions in the nanometer range. The development of cutting-edge approaches for grasping complicated processes at the nanoscale is critical. This review provides a concise overview of the prevalent methodologies developed over the last two decades and employed for the characterization of the Seebeck coefficient and electrical and thermal conductivity of thermoelectric films.

36 MATERIALS SCIENCE↗

Electron image contrast analysis of mosaicity in rutile nanocrystals using direct electron detection

Direct electron detection provides high detective quantum efficiency, significantly improved point spread function and fast read-out which have revolutionized the field of cryogenic electron microscopy. However, these benefits for high-resolution electron microscopy (HREM) are much less exploited, especially for in situ study where major impacts on crystallographic structural studies could be made. By using direct detection in electron counting mode, rutile nanocrystals have been imaged at high temperature inside an environmental transmission electron microscope. The improvements in image contrast are quantified by comparison with a charge-coupled device (CCD) camera and by image matching with simulations using an automated approach based on template matching. Together, these approaches enable a direct measurement of 3D shape and mosaicity (~1°) of a vacuum-reduced TiO 2 nanocrystal about 50 nm in size. Thus, this work demonstrates the possibility of quantitative HREM image analysis based on direct electron detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interpretation of F-106B in-flight lightning signatures

Various characteristics of the electromagnetic data obtained on a NASA F-106B aircraft during direct lightning strikes are presented. Time scales of interest range from 10 ns to 400 microsecond. The following topics are discussed: (1) Lightning current, I, measured directly versus I obtained from computer integration of measured I-dot; (2) A method of compensation for the low frequency cutoff of the current transformer used to measure I; (3) Properties of fast pulses observed in the lightning time-derivative waveforms; (4) The characteristic D-dot signature of the F-106B aircraft; (5) An RC-discharge interpretation for some lightning waveforms; (6) A method for inferring the locations of lightning channel attachment points on the aircraft by using B-dot data; (7) Simple, approximate relationships between D-dot and I-dot and between B and I; and (8) Estimates of energy, charge, voltage, and resistance for a particular lightning event.

Trost, T. F.↗

Time-resolved measurement of neutron energy isotropy in a sheared-flow-stabilized Z pinch

Previous measurements of neutron energy using fast plastic scintillators while operating the Fusion Z Pinch Experiment (FuZE) constrained the energy of any yield-producing deuteron beams to less than 4.65 keV. FuZE has since been operated at increasingly higher input power, resulting in increased plasma current and larger fusion neutron yields. A detailed experimental study of the neutron energy isotropy in these regimes applies more stringent limits to possible contributions from beam-target fusion. The FuZE device operated at -25 kV charge voltage has resulted in average plasma currents of 370 kA and D–D fusion neutron yields of $4\times10^7 \pm 4\times10^6$ neutrons per discharge. Measurements of the neutron energy isotropy under these operating conditions demonstrates the energy of deuteron beams is less than $7.4 \pm 5.6^\mathrm{(stat)} \pm 3.7^\mathrm{(syst)}$ keV. Characterization of the detector response has reduced the number of free parameters in the fit of the neutron energy distribution, improving the confidence in the forward-fit method. Gamma backgrounds have been measured and the impact of these contributions on the isotropy results have been studied. Additionally, a time dependent measurement of the isotropy has been resolved for the first time, indicating increases to possible deuteron beam energies at late times. This suggests the possible growth of m = 0 instabilities at the end of the main radiation event but confirms that the majority of the neutron production exhibits isotropy consistent with thermonuclear origin.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Fast Radio Burst Luminosity Function and Death Line in the Low-Twist Magnetar Model

We explore the burst energy distribution of fast radio bursts(FRBs)in the low-twist magnetar model ofWadiasingh & Timokhin(WT19). Motivated by the power-lawfluence distributions of FRB121102, we proposean elementary model for the FRB luminosity function of individual repeaters with an inversion protocol thatdirectly relates the power-law distribution index of magnetar short burstfluences to that for FRBs. The protocolindicates that the FRB energy scales virtually linearly with crust/field dislocation amplitude, if magnetar shortbursts prevail in the magnetoelastic regime. Charge starvation in the magnetosphere during bursts(required inWT19)for individual repeaters implies the predicted burstfluence distribution is narrow,3 decades for yieldingstrains and oscillation frequencies feasible in magnetar crusts. Requiring magnetic confinement and chargestarvation, we obtain a death line for FRBs, which segregates magnetars from the normal pulsar population,suggesting only the former will host recurrent FRBs. We convolve the burst energy distribution for individualmagnetars to define the distribution of luminosities in evolved magnetar populations. The broken power-lawluminosity function’s low-energy character depends on the population model, while the high-energy index tracesthat of individual repeaters. Independent of the evolved population, the broken power-law isotropic-equivalentenergy/luminosity function peaks at∼1037–1040erg with a low-energy cutoff at∼1037erg. Lastly, we considerthe localfluence distribution of FRBs andfind that it can constrain the subset of FRB-producing magnetarprogenitors. Our model suggests that improvements in sensitivity may reveal aflattening of the global FRBfluencedistribution and saturation in FRB rates.

Cosmology↗

Additively Manufactured Plastic Plasma Spectrometer

We report results in development and testing of a low resource top hat electrostatic analyzer (ESA) for space plasma measurements. This device has been additively manufactured (3D-printed) using fused deposition modeling. The classic top hat design is composed of four plastic pieces, without any surface coatings. The three conducting electrodes are printed from carbon nanotube infused polyether ether ketone (CNT-PEEK). The fourth piece, an insulating electrode support, uses pure PEEK. This ESA is designed to detect electrons in space from 10eV up to 30 keV. We demonstrate that the printed CNT-PEEK is sufficiently electrically conductive to support the fast high voltage slewing often required for high time resolution measurements. The plastic ESA has been successfully vibrated beyond standard pre-flight levels, tested under keV electron beam illumination over a wide range of temperatures, and tested under UV illumination, simulating the solar Ly-α flux. In comparison with an identical machined aluminum ESA, our CNT-PEEK ESA provides nominal energy/angle band passes, closely matching simulation. These band passes imply minimal impact from surface charging at beam energies of 2-3 keV, although more investigation is needed. We also find that the CNT-PEEK ESA provides far superior out-of-band electron rejection and UV photon rejection compared to the machined aluminum ESA. We do not detect any problems with trapped gases or outgassing. This development offers potential for significant mass savings, implementation of otherwise unattainable geometric configurations, and dramatic simplification in manufacturing and assembly processes required for development of space plasma instruments.

Quetzal Larrick↗

Voyager 2 electron observations in the magnetosphere of Neptune

This paper describes electron data obtained during the Neptune encounter by the Voyager 2 plasma science experiment. The densities and temperatures of low-energy (10-5950 eV) electrons and the electrostatic potential of the spacecraft near Neptune are derived. The data indicate that the escape of charged particles from Triton and the local ionization of atoms in the neutral torus originating from Triton are the major plasma sources. It is inferred that this neutral torus of hydrogen atoms has a density of about 300/cu cm and an inner boundary at 8 R(N). The data near Neptune exhibit signatures suggesting that both precipitation into Neptune's atmosphere and ring absorption are important plasma loss mechanisms. Plasma transport in the magnetosphere appears to be very fast; the diffusion coefficient is 1 x 10 exp -7 L exp 3 R(N) exp 2/sec.

Zhang, Ming↗

The Parameterization of Top-Hat Particle Sensors with Microchannel-Plate-Based Detection Systems and its Application to the Fast Plasma Investigation on NASA's Magnetospheric MultiScale Mission

The most common instrument for low energy plasmas consists of a top-hat electrostatic analyzer geometry coupled with a microchannel-plate (MCP)-based detection system. While the electrostatic optics for such sensors are readily simulated and parameterized during the laboratory calibration process, the detection system is often less well characterized. Furthermore, due to finite resources, for large sensor suites such as the Fast Plasma Investigation (FPI) on NASA's Magnetospheric Multiscale (MMS) mission, calibration data are increasingly sparse. Measurements must be interpolated and extrapolated to understand instrument behavior for untestable operating modes and yet sensor inter-calibration is critical to mission success. To characterize instruments from a minimal set of parameters we have developed the first comprehensive mathematical description of both sensor electrostatic optics and particle detection systems. We include effects of MCP efficiency, gain, scattering, capacitive crosstalk, and charge cloud spreading at the detector output. Our parameterization enables the interpolation and extrapolation of instrument response to all relevant particle energies, detector high voltage settings, and polar angles from a small set of calibration data. We apply this model to the 32 sensor heads in the Dual Electron Sensor (DES) and 32 sensor heads in the Dual Ion Sensor (DIS) instruments on the 4 MMS observatories and use least squares fitting of calibration data to extract all key instrument parameters. Parameters that will evolve in flight, namely MCP gain, will be determined daily through application of this model to specifically tailored in-flight calibration activities, providing a robust characterization of sensor suite performance throughout mission lifetime. Beyond FPI, our model provides a valuable framework for the simulation and evaluation of future detection system designs and can be used to maximize instrument understanding with minimal calibration resources.

Instrument-model↗

Novel indium phosphide charged particle detector characterization with a 120 GeV proton beam

Thin film detectors which incorporate semiconductor materials other than silicon have the potential to build upon their unique material properties and offer advantages such as faster response times, operation at room temperature, and radiation hardness. To explore the possibility, promising candidate materials were selected, and particle tracking detectors were fabricated. An indium phosphide detector with a metal-intrinsic-metal structure has been fabricated for particle tracking. The detector was tested using radioactive sources and a high energy proton beam at Fermi National Accelerator Laboratory. In addition to its simplistic design and fabrication process, the indium phosphide particle detector showed a very fast response time of hundreds of picoseconds for the 120 GeV protons, which are comparable to the ultra-fast silicon detectors. This fast-timing response is attributed to the high electron mobility of indium phosphide. Such material properties can be leveraged to build novel detectors with superlative performance.

47 OTHER INSTRUMENTATION↗

Optimal conditions for efficient flow-electrode capacitive deionization

One of the current barriers to achieving fast and stable performance for flow-electrode capacitive deionization (FCDI) is determining optimal operating parameters. To date, however, no consensus has been reached for universal conditions for FCDI. Through experimental and modeling approaches in this study, we systematically evaluated the influence of applied potential (V = 1.2–2.4 V) and electrolyte concentration (C0 = 0.05–0.5 M) on the FCDI and electrodialysis (ED) desalination processes. Evaluation indicators include the concentration decrease in the desalinated solution, salt removal rates, pH fluctuations, charge efficiency, and energy consumption. Results demonstrated that the dynamic curves of concentration decrease at 2.0 V nearly overlapped with the response at 1.6 V at certain electrolyte concentrations, while the salt removal rates at 0.2 M salt concentration were the best among all concentrations tested at a range of applied potential. Therefore, it was thus concluded that the optimum conditions for FCDI operation are 1.6 V applied potential and 0.2 M initial salt concentration, under which faradaic reactions are not being triggered, and concentration polarization does not significantly affect ion transfer. Furthermore, a comparative study between FCDI and ED indicated that ED has a different dependence on the electrolyte concentration and applied potential, in which the desalination can be linearly enhanced with increasing potential but greatly limited at high concentrations. Due to the presence of carbon particles in FCDI, the enhanced charge/ion transfer is probably the main reason for the different desalination performance of FCDI and ED. Overall, the optimal operating parameters obtained in this work could be used as basic test conditions for further development of new carbon-based materials for FCDI.

42 ENGINEERING↗

Hydration of a Side-Chain-Free n-Type Semiconducting Ladder Polymer Driven by Electrochemical Doping

Here, we study the organic electrochemical transistors (OECTs) performance of the ladder polymer, poly(benzimidazobenzophenanthroline) (BBL) in an attempt to better understand how an apparently hydrophobic side-chain-free polymer is able to operate as an OECT with favorable redox kinetics in an aqueous environment. We examine two BBLs of different molecular masses from different sources. Both BBLs show significant film swelling during the initial reduction step. By combining electrochemical quartz crystal microbalance (eQCM) gravimetry, in-operando atomic force microscopy (AFM), and both ex-situ and in-operando grazing incidence wide-angle x-ray scattering (GIWAXS), we provide a detailed structural picture of the electrochemical charge injection process in BBL in the absence of any hydrophilic side-chains. Compared with ex-situ measurements, inoperando GIWAXS shows both more swelling upon electrochemical doping than has previously been recognized, and less contraction upon dedoping. The data show that BBL films undergo an irreversible hydration driven by the initial electrochemical doping cycle with significant water retention and lamellar expansion that persists across subsequent oxidation/reduction cycles. This swelling creates a hydrophilic environment that facilitates the subsequent fast hydrated ion transport in the absence of the hydrophilic side-chains used in many other polymer systems. Due to its rigid ladder backbone and absence of hydrophilic side-chains, the primary BBL water uptake does not significantly degrade the crystalline order, and the original dehydrated, unswelled state can be recovered after drying. The combination of doping induced hydrophilicity and robust crystalline order leads to efficient ionic transport and good stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Directly Embedded Ni3S2/Co9S8@S-Doped Carbon Nanofiber Networks as a Free-Standing Anode for Lithium-Ion Batteries

Transition metal sulfides as electrode materials for lithium-ion batteries have attracted significant research attention due to their high theoretical capacity, excellent redox reversibility, and earth abundance. However, this material family still suffers from poor conductivity and experiences huge volume changes. Here, we demonstrate a facile and scalable electrospinning method to prepare Ni3S2 and Co9S8 nanoparticles embedded in sulfur doped carbon nanofiber networks as a free-standing anode material for lithium ion batteries. Similar to literature findings, the coupling of two different metal sulfides indeed synergistically promoted the electrochemical performance. Embedding them within individual carbon nanofibers not only enhances the intrinsic conductivity, but also provides a highly stable structure, which results in excellent battery performance. Furthermore, the individual carbon nanofibers intertwine with each other to form a free-standing 3D nanofiber network which acts as a freeway network for fast electron transfer and the pores between fibers allow easy penetration of the electrolyte, namely easy lithium ion access to active nanoparticles. When directly applied as the anode in lithium ion batteries, the free-standing nanofiber mat bypassed all slurry making steps and showed excellent cycling stability with a high specific capacity of 528 mA h g-1 after 200 cycles at a current density of 300 mA g-1. Good rate capability was also obtained. Additionally, the charge storage process analysis indicated that the pseudocapacitive behavior of the material is attributed to its good performance. This work introduces a facile strategy to simultaneously and in situ generate Co9S8 and Ni3S2 nanoparticles within a S-doped carbon fiber matrix via facile electrospinning followed by a one-step heating procedure. It is demonstrated that the free-standing transition bimetallic sulfide nanofibers prepared are very promising for light and small battery applications.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

Alternative CNDOL Fockians for fast and accurate description of molecular exciton properties

CNDOL is an a priori, approximate Fockian for molecular wave functions. In this study, we employ several modes of singly excited configuration interaction (CIS) to model molecular excitation properties by using four combinations of the one electron operator terms. Those options are compared to the experimental and theoretical data for a carefully selected set of molecules. The resulting excitons are represented by CIS wave functions that encompass all valence electrons in the system for each excited state energy. The Coulomb–exchange term associated to the calculated excitation energies is rationalized to evaluate theoretical exciton binding energies. This property is shown to be useful for discriminating the charge donation ability of molecular and supermolecular systems. Multielectronic 3D maps of exciton formal charges are showcased, demonstrating the applicability of these approximate wave functions for modeling properties of large molecules and clusters at nanoscales. This modeling proves useful in designing molecular photovoltaic devices. Our methodology holds potential applications in systematic evaluations of such systems and the development of fundamental artificial intelligence databases for predicting related properties.

Chemistry↗

Fast dynamic aperture optimization with forward-reversal integration

A fast dynamic aperture (DA) optimization method for storage rings has been developed through the use of reversal integration. Even if dynamical systems have an exact reversal symmetry, a numerical forward integration differs from its reversal. For a chaotic trajectory, cumulative round-off errors are scaled, which results in an exponential growth on the difference. The exponential effect is a generic chaos indicator which represents the sensitivity of the chaotic motion to its initial condition. The chaos indicator of the charged particle motion can be obtained by comparing the forward integrations of particle trajectories with corresponding reversals, a.k.a. “backward integrations.” The indicator is observable even through short-term particle tracking simulations. Therefore, adopting it as an objective function could speed up optimization. Finally, the DA of the National Synchrotron Light Source II storage ring, and another test diffraction-limited light source ring, were optimized using this method for the purpose of demonstration.

43 PARTICLE ACCELERATORS↗

Improving Signal to Noise Ratios in Ion Mobility Spectrometry and Structures for Lossless Ion Manipulations (SLIM) using a High Dynamic Range Analog-to-Digital Converter

Signal digitization is a commonly overlooked part of ion mobility-mass spectrometry (IMS-MS) workflows, yet it is a significant contributor for determining signal-to-noise ratios and MS resolution. Here we report on the integration of a 2 GS/s, 14-bit ADC with a structures for lossless ion manipulations (SLIM)-IMS-MS and compare the performance to a commonly used 8-bit ADC. The 14-bit ADC provided an effective reduction in digitized noise by factor of ~6, owing largely to the use of smaller bit sizes. The low baseline allowed the threshold voltage levels to be set very close to the MCP baseline voltage, allowing for as much signal to be acquired as possible without causing overloading or excessive digitization of MCP baseline noise. Analyses of Agilent tuning mixture ions and a complex mixture of heavy labeled phosphopeptides showed that the 14-bit ADC (compared to the 8-bit ADC) provided a modest signal-to-noise increase (~1.5 to 2-fold) for high intensity ions, such as the Agilent tuning mixture ions and the 2+ and 3+ charge states of many phosphopeptide constituents. However, signal enhancements were as much as 10-fold for low intensity ions, and the 14-bit ADC enabled discernable signal intensities otherwise lost using an 8-bit digitizer. Additionally, the 14-bit ADC required ~14-fold fewer mass spectra to be averaged to produce a mass spectrum with similar S/N as the 8-bit ADC under identical conditions, potentially providing an order of magnitude higher measurement throughput. The high resolution, low baseline, and fast speed of the new 14-bit ADC enables high performance digitization of MS, IMS-MS, and SLIM-IMS-MS spectra, and allows a much fuller picture of analyte profiles in complex mixtures to be acquired.

data acquisition, digitization, ion mobility spect↗

Advanced Electronics for the SONTRAC Neutron Spectrometer

Solar neutrons are the tell-tale of highly energetic processes (e.g. solar flares) at the Sun in which particle acceleration is taking place over a broad range in energy. Unlike charged radiation, neutrons escape unscathed from the ambient magnetic fields, providing a view of particle acceleration unhindered by the effects of transport. High-energy neutrons are challenging to measure with the traditional double scatter technique based on time-of-flight (ToF). This technique is limited by the finite flight path and active scintillator sizes required by small satellite platforms. The new SOlar Neutron TRACking (SONTRAC) concept, based on scintillating-fiber bundles, will provide high resolution imaging of fast neutrons at energies where the bulk of solar and magnetospheric neutrons resides. Recent development of the new SONTRAC instrument concept's advanced electronics and processing algorithms are presented.

SiPM readout↗

High precision real-time insertion device and monochromator synchronization at NSLS-II

We report that insertion devices have become the dominant photon source at synchrotron and free electron laser light source facilities the world over. Undulators, characterized by their small deflection parameter, exhibit a high degree of constructive interference in photon production from high energy charged particle beams leading to very high photon rates at specific harmonics of the fundamental frequency with relatively narrow spectral widths. Spectroscopic measurements of interest typically span several of these harmonic widths, which requires precision adjustment of an undulator’s magnetic gap to maintain peak flux within the much narrower bandwidth of a beamline monochromator at the desired energy. High precision insertion device controls are developed at NSLS-II including real-time linked control of monochromator hardware allowing for fast, high precision, hardware triggered, spectroscopic measurements. Furthermore, this fast fly scan method is described, compared statistically for self consistency, and shown to be far superior in both efficiency and accuracy as compared to standard step scan measurements.

36 MATERIALS SCIENCE↗

Accurate contrast determination for X-ray speckle visibility spectroscopy

X-ray speckle visibility spectroscopy using X-ray free-electron lasers has long been proposed as a probe of fast dynamics in noncrystalline materials. In this paper, numerical modeling is presented to show how the data interpretation of visibility spectroscopy can be impacted by the nonidealities of real-life X-ray detectors. Using simulated detector data, this work provides a detailed analysis of the systematic errors of several contrast extraction algorithms in the context of low-count-rate X-ray speckle visibility spectroscopy and their origins are discussed. Here, it was found that the finite detector charge cloud and pixel size lead to an unavoidable `degeneracy' in photon position determination, and that the contrasts extracted using different algorithms can all be corrected by a simple linear model. The results suggest that experimental calibration of the correction coefficient at the count rate of interest is possible and essential. This allows computationally lightweight algorithms to be implemented for on-the-fly analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗