Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Failure Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Electromigration in thin-film photovoltaic module metallization systems

Electromigration as a possible thin-film module failure mechanism was investigated using several specially made, fully aluminized thin-film photovoltaic (TF-PV) modules. The effect of electromigration, as determined experimentally by measuring increases in electrical resistance across scribe lines, can be expressed as the product of a damage function, which correlates degradation rate with operating conditions such as current density and temperature, and a susceptibility function, which is defined by module design parameters, particularly aluminum purity and the configuration of the intercell region. Experimental measurements and derived acceleration factors suggest that open-circuit failure resulting from electromigration should not be a serious problem in present state-of-the-art TF-PV modules. Nevertheless, significant intercell resistance increases can result from long-term electromigration exposure, especially in future high-efficiency modules. The problem can be alleviated, however, by appropriate metallization applications and/or proper design of the intercell region.

Wen, L.↗

Making Plasticized Polymer Electrolytes Stable Against Sodium Metal for High‐Energy Solid‐State Sodium Batteries

Abstract Solid polymer electrolytes based on plastic crystals are promising for solid‐state sodium metal (Na 0 ) batteries, yet their practicality has been hindered by the notorious Na 0 ‐electrolyte interface instability issue, the underlying cause of which remains poorly understood. Here, by leveraging a model plasticized polymer electrolyte based on conventional succinonitrile plastic crystals, we uncover its failure origin in Na 0 batteries is associated with the formation of a thick and non‐uniform solid electrolyte interphase (SEI) and whiskery Na 0 nucleation/growth. Furthermore, we design a new additive‐embedded plasticized polymer electrolyte to manipulate the Na 0 deposition and SEI formulation. For the first time, we demonstrate that introducing fluoroethylene carbonate (FEC) additive into the succinonitrile‐plasticized polymer electrolyte can effectively protect Na 0 against interfacial corrosion by facilitating the growth of dome‐like Na 0 with thin, amorphous, and fluorine‐rich SEIs, thus enabling significantly improved performances of Na//Na symmetric cells (1,800 h at 0.5 mA cm −2 ) and Na//Na 3 V 2 (PO 4 ) 3 full cells (93.0 % capacity retention after 1,200 cycles at 1 C rate in coin cells and 93.1 % capacity retention after 250 cycles at C/3 in pouch cells at room temperature). Our work provides valuable insights into the interfacial failure of plasticized polymer electrolytes and offers a promising solution to resolving the interfacial instability issue.

Zou, Peichao↗

A new technique for simultaneous monitoring of electrocardiogram and walking cadence

A new technique for simultaneously recording continuous electrocardiographic (ECG) data and walking step rate (cadence) is described. The ECG and gait signals are recorded on 2 channels of an ambulatory Holter monitor. Footfall is detected using ultrathin, force-sensitive foot switches and is frequency modulated. The footfall signal provides an indication of the subject's activity (walking or standing), as well as the instantaneous walking rate. Twenty-three young and elderly subjects were studied to demonstrate the use of this ECG and gait recorder. High-quality gait signals were obtained in all subjects, and the effects of walking on the electrocardiogram were assessed. Initial investigation revealed the following findings: (1) Although walking rates were similar in young and elderly subjects, the elderly had both decreased heart rate (HR) variability (p < 0.005) and increased cadence variability (p < 0.0001). (2) Overall, there was an inverse relation between HR and cadence variability (r = -0.73). Three elderly subjects with no known cardiac disease had HR and cadence variability similar to those of the young, whereas elderly subjects with history of congestive heart failure were among those with the lowest HR variability and the highest cadence variability. (3) Low-frequency (approximately equal to 0.1 Hz) HR oscillations (frequently observed during standing) persisted during walking in all young subjects. (4) In some subjects, both step rate and HR oscillated at the same low frequency (approximately equal to 0.1 Hz) previously identified with autonomic control of the baroreflex.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Cardiopulmonary↗

Frequency–Magnitude Statistics of Laboratory Foreshocks Vary With Shear Velocity, Fault Slip Rate, and Shear Stress

Understanding the nucleation phase of earthquakes is key for advancing earthquake hazard assessment and improving earthquake early warning systems. However, little progress has been made in this area due to a poor understanding of nucleation processes and incomplete seismic and fault zone measurements. The ability to integrate measured fault zone properties with seismic data could significantly improve our understanding of how earthquakes begin and whether there are systematic variations in seismic properties preceding failure. In this work, we use high-resolution laboratory measurements of fault zone properties along with acoustic emission data to document temporal variations of foreshock properties. Our data show that foreshock size increases with shear stress, loading rate, and fault slip rate. We propose that the preseismic fault slip rate and fault zone thickness (i.e., porosity) work in concert to modulate foreshock properties.

15 GEOTHERMAL ENERGY↗

A Piloted Evaluation of Damage Accommodating Flight Control Using a Remotely Piloted Vehicle

Toward the goal of reducing the fatal accident rate of large transport airplanes due to loss of control, the NASA Aviation Safety Program has conducted research into flight control technologies that can provide resilient control of airplanes under adverse flight conditions, including damage and failure. As part of the safety program s Integrated Resilient Aircraft Control Project, the NASA Airborne Subscale Transport Aircraft Research system was designed to address the challenges associated with the safe and efficient subscale flight testing of research control laws under adverse flight conditions. This paper presents the results of a series of pilot evaluations of several flight control algorithms used during an offset-to-landing task conducted at altitude. The purpose of this investigation was to assess the ability of various flight control technologies to prevent loss of control as stability and control characteristics were degraded. During the course of 8 research flights, data were recorded while one task was repeatedly executed by a single evaluation pilot. Two generic failures, which degraded stability and control characteristics, were simulated inflight for each of the 9 different flight control laws that were tested. The flight control laws included three different adaptive control methodologies, several linear multivariable designs, a linear robust design, a linear stability augmentation system, and a direct open-loop control mode. Based on pilot Cooper-Harper Ratings obtained for this test, the adaptive flight control laws provided the greatest overall benefit for the stability and control degradation scenarios that were considered. Also, all controllers tested provided a significant improvement in handling qualities over the direct open-loop control mode.

Cunningham, Kevin↗

Performance degradation due to anodic failure mechanisms in lithium-ion batteries

Here, we report a mechano-chemical model for anodic degradation during fast-charging of nickel-manganese-cobalt (NMC)/graphite (C) cell due to SEI growth, lithium plating/stripping, dead lithium storage, and film fracture of composite SEI and plated lithium film. Degradation of the battery is analyzed for a range of charging rates from 1 to 6 C-rates, and the influence of plating mechanisms – lithium plating and dead lithium deposition and recovery during stripping – on the film resistance of the anode are accounted for in the model. Dynamic evolution of the interfacial properties is modeled using rule-of-mixture approach. Model predictions of plating associated stress fields are used to compute critical energy release rate for film cracking. The results indicate an increased tendency of fracture for thinner SEI film with lithium plating at higher charging rates. The process of reforming the cracked film absorbs a significant portion of the electrode current thereby reducing the cell capacity and plating efficiency. The mechano-chemical model provides an extensive analytical framework for understanding the synergistic coupling of anodic degradation mechanisms, prognosticating conditions of SEI failure, and evaluating the capacity fade and efficiency of lithium-ion battery.

25 ENERGY STORAGE↗

Open-Hole Testing of Resin Infused Carbon Composite Laminates to Facilitate Damage Growth and Failure Analysis Tools for Structural Design

In manufacturing of carbon-fiber reinforced composite aircraft structures, resin infusion offers a highly repeatable process for manufacturing structural components with resin content control, low labor requirements, and complex curvatures. To further understand the structural capabilities of res-in infused composites (RIC), this study – as part of the NASA-led Hi-Rate Composite Aircraft Manufacturing project efforts – performed open hole tension (OHT) and open hole compression (OHC) testing on RIC laminates. This testing provides information on the damage morphology and growth characteristics of RICs, which fuels the development and evaluation of analysis tools for progressive damage growth and failure responses. X-ray computed tomography (XCT) was implemented on each OHC and OHT specimen prior to mechanical testing to identify preexisting damage and/or defects. Two OHT and OHC specimens were loaded monotonically to failure and an additional OHT and OHC specimen were loaded intermittently at defined conditions and XCT scanned after each run. From the data obtained in this study, damage mechanisms leading to failure were identified, damage morphology and size were assessed, and damage initiation and failure loads were measured.

HiCAM↗

Making Plasticized Polymer Electrolytes Stable Against Sodium Metal for High‐Energy Solid‐State Sodium Batteries

Solid polymer electrolytes based on plastic crystals are promising for solid-state sodium metal (Na 0 ) batteries, yet their practicality has been hindered by the notorious Na 0 -electrolyte interface instability issue, the underlying cause of which remains poorly understood. Here, in this study, by leveraging a model plasticized polymer electrolyte based on conventional succinonitrile plastic crystals, we uncover its failure origin in Na 0 batteries is associated with the formation of a thick and non-uniform solid electrolyte interphase (SEI) and whiskery Na 0 nucleation/growth. Furthermore, we design a new additive-embedded plasticized polymer electrolyte to manipulate the Na 0 deposition and SEI formulation. For the first time, we demonstrate that introducing fluoroethylene carbonate (FEC) additive into the succinonitrile-plasticized polymer electrolyte can effectively protect Na 0 against interfacial corrosion by facilitating the growth of dome-like Na 0 with thin, amorphous, and fluorine-rich SEIs, thus enabling significantly improved performances of Na//Na symmetric cells (1,800 h at 0.5 mA cm −2 ) and Na//Na 3 V 2 (PO 4 ) 3 full cells (93.0 % capacity retention after 1,200 cycles at 1 C rate in coin cells and 93.1 % capacity retention after 250 cycles at C/3 in pouch cells at room temperature). Our work provides valuable insights into the interfacial failure of plasticized polymer electrolytes and offers a promising solution to resolving the interfacial instability issue.

25 ENERGY STORAGE↗

Field Experience Detecting PV Underperformance in Real Time Using Existing Instrumentation

Maintenance at large-scale photovoltaic plants employs a mix of preventative and corrective maintenance practices. Large outages, such as an inverter tripping offline, are often easy to detect. More subtle sub-inverter faults and failures can accumulate and go unnoticed for months or years. A software-based fault detection method has been developed to analyze commonly measured data from large-scale PV plants for more timely detection of subtle underperformance. The method has been demonstrated on eight datasets from large-scale plants with high accuracy of detection. Results are validated using aerial infrared scanning. String outages are detected with a true positive rate of 73 percent and tracker issues are detected with a true positive rate of 88 percent. The developed method can be uniformly applied to photovoltaic plants across a range of scales and configurations to assess performance, quickly detect underperformance, and determine the source and location of failures. The results inform and improve operations and maintenance at PV plants, ultimately aiding in improved affordability, reliability, availability, and resiliency of solar electricity.

14 SOLAR ENERGY↗

Qualitative differences between on-orbit and transition RCS control

Two separate reaction control system (RCS) digital autopilots (DAPs) evolved from one original Space Shuttle orbital autopilot concept. A computer overload forced this evolution. Part of the overload problem was due to unique performance requirements imposed on the RCS controller during each of several different flight regimes. The two resultant RCS DAPs yield different effector responses because they rely on different sources of sensory input and they process data differently. This paper describes the evolution of the two RCS controllers and illustrates their behavioral differences. The transition autopilot, used in orbital insertion and deorbit, is sensitive to orbiter flexure due to its feedthrough character. The on-orbit autopilot is sensitive to transient rate control degradation from large disturbances due to feed-forward rate estimation. Simulation results and flight data are used to illustrate performance differences between the two autopilots under various conditions. These include computer failures where electronic stringing and procedural reconfiguration differences affect autopilot behavior.

Hattis, P. D.↗

Advanced Gas Turbine (AGT) power-train system development

Technical work on the design and component testing of a 74.5 kW (100 hp) advanced automotive gas turbine is described. Selected component ceramic component design, and procurement were tested. Compressor tests of a modified rotor showed high speed performance improvement over previous rotor designs; efficiency improved by 2.5%, corrected flow by 4.6%, and pressure ratio by 11.6% at 100% speed. The aerodynamic design is completed for both the gasifier and power turbines. Ceramic (silicon carbide) gasifier rotors were spin tested to failure. Improving strengths is indicated by burst speeds and the group of five rotors failed at speeds between 104% and 116% of engine rated speed. The emission results from combustor testing showed NOx levels to be nearly one order of magnitude lower than with previous designs. A one piece ceramic exhaust duct/regenerator seal platform is designed with acceptable low stress levels.

Helms, H. E.↗

Characterization of debond growth mechanism in adhesively bonded composites under mode II static and fatigue loadings

An experimental investigation of adhesively bonded composite joint was conducted to characterize the debond growth mechanism under mode II static and fatigue loadings. For this purpose, end-notched flexure specimens of graphite/epoxy (T300/5208) adherends bonded with EC 3445 adhesive were tested. In all specimen tested, the fatigue failure occurred in the form of cyclic debonding. The present study confirmed the result of previous studies that total strain-energy-release rate is the driving parameter for cyclic debonding. Further, the debond growth resistance under cyclic loading with full shear reversal (i.e., stress ratio, R = -1) is drastically reduced in comparison to the case when subjected to cyclic shear loading with no shear reversal (i.e., R = 0.1).

Mall, S.↗

Reliability and risk assessment of structures

Development of reliability and risk assessment of structural components and structures is a major activity at Lewis Research Center. It consists of five program elements: (1) probabilistic loads; (2) probabilistic finite element analysis; (3) probabilistic material behavior; (4) assessment of reliability and risk; and (5) probabilistic structural performance evaluation. Recent progress includes: (1) the evaluation of the various uncertainties in terms of cumulative distribution functions for various structural response variables based on known or assumed uncertainties in primitive structural variables; (2) evaluation of the failure probability; (3) reliability and risk-cost assessment; and (4) an outline of an emerging approach for eventual certification of man-rated structures by computational methods. Collectively, the results demonstrate that the structural durability/reliability of man-rated structural components and structures can be effectively evaluated by using formal probabilistic methods.

Chamis, C. C.↗

Space transportation architecture: Reliability sensitivities

A sensitivity analysis is given of the benefits and drawbacks associated with a proposed Earth to orbit vehicle architecture. The architecture represents a fleet of six vehicles (two existing, four proposed) that would be responsible for performing various missions as mandated by NASA and the U.S. Air Force. Each vehicle has a prescribed flight rate per year for a period of 31 years. By exposing this fleet of vehicles to a probabilistic environment where the fleet experiences failures, downtimes, setbacks, etc., the analysis involves determining the resiliency and costs associated with the fleet of specific vehicle/subsystem reliabilities. The resources required were actual observed data on the failures and downtimes associated with existing vehicles, data based on engineering judgement for proposed vehicles, and the development of a sensitivity analysis program.

Williams, A. M.↗

In-flight demonstration of hybrid GPS/Loran RAIM

A receiver autonomous integrity monitoring (RAIM) scheme has been implemented in a real time, prototype hybrid GPS/LORAN receiver. A four-channel GPS receiver and an eight-channel LORAN-C receiver are used to obtain raw GPS and LORAN pseudorange measurements. The measurement data is sent to a microcomputer for position and integrity determination. Navigation data is presented to the pilot on a standard course deviation indicator with a data renewal rate of up to one update per second. Provisions are made to simulate signal malfunctions in real time by injecting step or ramp failures in the pseudorange measurements. A least-squares fault detection algorithm is presented for the detection of slowly growing measurement errors. The performance of the hybrid GPS/LORAN receiver has been demonstrated through actual flight tests. One of the flight tests is summarized in the paper.

Van Graas, Frank↗

Qualification of the Tropical Rainfall Measuring Mission Solar Array Deployment System

The Tropical Rainfall Measuring Mission (TRMM) solar arrays are placed into orbital configuration by a complex deployment system. Its two wings each comprise twin seven square solar panels located by a twelve foot articulated boom. The four spring-driven hinge lines per wing are rate-limited by viscous dampers. The wings are stowed against the spacecraft kinematically, and released by five pyrotechnically-actuated mechanisms. Since deployment failure would be catastrophic, a total of 17 deployment tests were completed to qualify the system for the worst cast launch environment. This successful testing culminated in the flawless deployment of the solar arrays on orbit, 15 minutes after launch in November 1997. The custom gravity negation system used to perform deployment testing is modular to allow its setup in several locations, including the launch site in Japan. Both platform and height can be varied, to meet the requirements of the test configuration and the test facility. Its air pad floatation system meets tight packaging requirements, allowing installation while stowed against the spacecraft without breaking any flight interfaces, and avoiding interference during motion. This system was designed concurrently with the deployment system, to facilitate its installation, to aid in the integration of the flight system to the spacecraft, while demonstrating deployment capabilities. Critical parameters for successful testing were alignment of deployment axes and tables to gravity, alignment of table seams to minimize discontinuities, and minimizing pressure drops in the air supply system. Orbital performance was similar to that predicted by ground testing.

Lawrence, Jon↗

Delayed Alumina Scale Spallation on Rene'n5+y: Moisture Effects and Acoustic Emission

The single crystal superalloy Rene'N5 (with or without Y-doping and hydrogen annealing) was cyclically oxidized at 1150 C for 1000 hours. After considerable scale growth (>= 500 hours), even the adherent alumina scales formed on Y-doped samples exhibited delayed interfacial spallation during subsequent water immersion tests, performed up to one year after oxidation. Spallation was characterized by weight loss, the amount of spalled area, and acoustic emission response. Hydrogen annealing (prior to oxidation) reduced spallation both before and after immersion, but without measurably reducing the bulk sulfur content of the Y-doped alloys. The duration and frequency of sequential, co-located acoustic emission events implied an interfacial crack growth rate at least 10(exp -3) m/s, but possibly higher than 10(exp 2) m/s. This is much greater than classic moisture-assisted slow crack growth rates in bulk alumina (10(exp -6) to 10(exp -3) m/s), which may still have occurred undetected by acoustic emission. An alternative failure sequence is proposed: an incubation process for preferential moisture ingress leads to a local decrease in interfacial toughness, thus allowing fast fracture driven by stored strain energy.

Smialek, James L.↗

Diagnosis and management of baroreflex failure

Baroreflex failure has a range of presentations, varying from the acute onset of a hypertensive crisis to a chronically volatile blood pressure and heart rate with hypertensive surges in response to stress, punctuated by periods of normal or even low blood pressure during rest. Differentiating this syndrome from other causes of labile hypertension is essential in devising effective treatment.

Review, Tutorial↗