Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Environmental Protection Agency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Ammonia Generation and Utilization in a Passive SCR (TWC+SCR) System on Lean Gasoline Engine

Lean gasoline engines offer greater fuel economy than the common stoichiometric gasoline engine, but the current three-way catalyst (TWC) on stoichiometric engines is unable to control nitrogen oxide (NOX) emissions in the oxygen-rich exhaust. Thus, lean NOX emission control is required to meet existing Tier 2 and upcoming Tier 3 emission regulations set by the U.S. Environmental Protection Agency (EPA). While urea-based selective catalytic reduction (SCR) has proven effective in controlling NOX from diesel engines, the urea storage and delivery components can add significant size and cost. As such, onboard NH3 production via a passive SCR approach is of interest. In a passive SCR system, NH3 is generated over a close-coupled TWC during periodic slightly rich engine operation and subsequently stored on an underfloor SCR catalyst. Upon switching to lean operation, NOX passes through the TWC and is reduced by the stored NH3 on the SCR catalyst. In this work, a passive SCR system was evaluated on a 2.0-liter BMW lean burn gasoline direct injection engine to assess NH3 generation over a Pd-only TWC and utilization over a Cu-based SCR catalyst. System NOX reduction efficiency and fuel efficiency improvement compared to stoichiometric engine operation were measured. A feedback control strategy based on cumulative NH3 produced by the TWC during rich operation and NOX emissions during lean operation was implemented on the engine to control lean/rich cycle timing. 15% excess NH3 production over a 1:1 NH3:NOX ratio was required (via longer rich cycle timing) to achieve 99.7% NOX conversion at an SCR average inlet temperature of 350 C. Increasing NH3 generation further resulted in even higher NOX conversion; however, tailpipe NH3 emissions resulted. At higher temperatures, NH3 oxidation becomes important and limits NH3 availability for NOX reduction. At the engine conditions studied here, greater than 99% NOX conversion was achieved with passive SCR while delivering fuel efficiency benefits ranging between 6-11% compared with stoichiometric operation.

Prikhodko, Vitaly Y↗

Model Year 2017 Fuel Economy Guide: EPA Fuel Economy Estimates

The Fuel Economy Guide is published by the U.S. Department of Energy as an aid to consumers considering the purchase of a new vehicle. The Guide lists estimates of miles per gallon (mpg) for each vehicle available for the new model year. These estimates are provided by the U.S. Environmental Protection Agency in compliance with Federal Law. By using this Guide, consumers can estimate the average yearly fuel cost for any vehicle. The Guide is intended to help consumers compare the fuel economy of similarly sized cars, light duty trucks and special purpose vehicles.

biodiesel↗

Personal Fuel Economy in Conventional and Hybrid Electric Vehicles: Integrating Driving Cycle Predictions with Power Distribution Optimization

Improving fuel efficiency and lowering emissions are key societal goals. Standard driving cycles, pre-designed by the US Environmental Protection Agency (EPA), have long been used to estimate vehicle fuel efficiency in laboratory controlled conditions. They have also been used to test and tune different energy management strategies for hybrid electric vehicles (HEVs). This study uses standard driving cycles as a base for comparison, while aiming to develop fuel efficiency estimates based on personalized driving cycles that can inform consumers’ vehicle purchase and use decisions. To do this, we extracted driving cycles for conventional vehicles and HEVs from a large-scale survey that contains real-world GPS-based driving records. Next, the driving cycles were assigned to one of three categories: aggressive, normal, or calm. Then the driving cycles were used along with a driver-vehicle simulation that captures driver decisions (vehicle speed during a trip), powertrain, and vehicle dynamics to estimate personal fuel efficiency for conventional vehicles and HEVs. To optimize personal fuel efficiency estimates, the Equivalent Consumption Minimization Strategy (ECMS) is applied. Depending on the driving style (aggressive, normal, or calm) and the driving scenario (city or highway driving), conventional vehicle fuel consumption can vary widely compared with standard EPA driving cycles. Specifically, conventional vehicle fuel efficiency was 13% lower in calm city driving, but almost 34% higher for aggressive highway driving compared with standard EPA driving cycles. Interestingly, when a driving cycle is predicted based on application of case-based reasoning and used to tune the power distribution in HEVs, their fuel consumption can improve by up to 12% in city driving. Implications and limitations of the findings are discussed in the paper.

Liu, Jun↗

U.S. Light-duty Vehicle Air Conditioning Fuel Use and the Impact of Four Solar/Thermal Control Technologies

The U.S. uses 7.6 billion gallons of fuel per year for vehicle air conditioning (A/C), equivalent to 5.7 percent of the total national light-duty vehicle (LDV) fuel use. This equates to 30 gallons/year per vehicle, or 23.5 grams (g) of carbon dioxide (CO2) per mile, for an average U.S. vehicle. A/C is a significant contribution to national fuel use; therefore, technologies that reduce A/C loads may reduce operational costs, A/C fuel use, and CO2 emissions. Since A/C is not operated during standard EPA fuel economy testing protocols, EPA provides off-cycle credits to encourage OEMs to implement advanced A/C technologies that reduce fuel use in the real world. NREL researchers assessed thermal/solar off-cycle credits available in the U.S. Environmental Protection Agency's (EPA's) Final Rule for Model Year 2017 and Later Light-Duty Vehicle Greenhouse Gas Emissions and Corporate Average Fuel Economy. Credits include glazings, solar reflective paint, and passive and active cabin ventilation. Implementing solar control glass reduced CO2 emissions by 2.0 g/mi, and solar reflective paint resulted in a reduction of 0.8 g/mi. Active and passive ventilation strategies only reduced emissions by 0.1 and 0.2 g/mi, respectively. The national-level analysis process is powerful and general; it can be used to determine the impact of a wide range of new vehicle thermal technologies on fuel use, EV range, and CO2 emissions.

30 DIRECT ENERGY CONVERSION↗

Model Year 2018 Fuel Economy Guide: EPA Fuel Economy Estimates

The Fuel Economy Guide is published by the U.S. Department of Energy as an aid to consumers considering the purchase of a new vehicle. The Guide lists estimates of miles per gallon (mpg) for each vehicle available for the new model year. These estimates are provided by the U.S. Environmental Protection Agency in compliance with Federal Law. By using this Guide, consumers can estimate the average yearly fuel cost for any vehicle. The Guide is intended to help consumers compare the fuel economy of similarly sized cars, light duty trucks and special purpose vehicles.

biodiesel↗

Methodology for National Water Savings Model and Spreadsheet Tool—Outdoor Water Use

This report describes the method Lawrence Berkeley National Laboratory (LBNL) developed to estimate national impacts of the U.S. Environmental Protection Agency’s (EPA’s) WaterSense labeling program for weather-based irrigation controllers (WBIC). Estimated impacts include the national water savings attributable to the program and the net present value of the lifetime water savings for consumers of irrigation controllers.

Chen, Yuting↗

Field Test to Evaluate Deep Borehole Disposal.

The U.S. Department of Energy (DOE) has embarked on the Deep Borehole Field Test (DBFT), which will investigate whether conditions suitable for disposal of radioactive waste can be found at a depth of up to 5 km in the earth’s crust. As planned, the DBFT will demonstrate drilling and construction of two boreholes, one for initial scientific characterization, and the other at a larger diameter such as could be appropriate for waste disposal (the DBFT will not involve radioactive waste). A wide range of geoscience activities is planned for the Characterization Borehole, and an engineering demonstration of test package emplacement and retrieval is planned for the larger Field Test Borehole. Characterization activities will focus on measurements and samples that are important for evaluating the long-term isolation capability of the Deep Borehole Disposal (DBD) concept. Engineering demonstration activities will focus on providing data to evaluate the concept’s operational safety and practicality. Procurement of a scientifically acceptable DBFT site and a site management contractor is now underway. The concept of deep borehole disposal (DBD) for radioactive wastes is not new. It was considered by the National Academy of Science (NAS 1957) for liquid waste, studied in the 1980’s in the U.S. (Woodward–Clyde 1983), and has been evaluated by European waste disposal R&D programs in the past few decades (for example, Grundfelt and Crawford 2014; Grundfelt 2010). Deep injection of wastewater including hazardous wastes is ongoing in the U.S. and regulated by the Environmental Protection Agency (EPA 2001). The DBFT is being conducted with a view to use the DBD concept for future disposal of smaller-quantity, DOE-managed wastes from nuclear weapons production (i.e., Cs/Sr capsules and granular solid wastes). However, the concept may also have broader applicability for nations that have a need to dispose of limited amounts of spent fuel from nuclear power reactors. For such nations the cost for disposing of volumetrically limited waste streams could be lower than mined geologic repositories.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessing Alignment Between a Top-Down LCA Model and a Bottom-Up Supply Chain Model for Data Gap Identification and Prioritization

This work presents a method for evaluating the alignment between the results of bottom-up and top-down models and using the evaluation to enhance the bottom-up model and underlying data set. Disaggregation is used to enhance the embodied energy results of top-down models, which are then compared to bottom-up model results. Using the disaggregated top-down results makes it possible to identify specific data gaps and deficiencies within the bottom-up model and its data set. The top-down results will also provide information around which data gaps in the bottom-up model are contributing the most error to the results; in this way, data gaps can be identified as either critical or non-critical, and the effort needed to acquire and add data can be prioritized. Although the proposed method could be applied to any physical quantity or environmental impact that can be quantified with both bottom-up models (typically in physical units) and top-down models (typically in monetary units), embodied energy is the focus of this work. The disaggregated energy baseline is calculated from the throughput vector x, which gives the total economic activity required from each sector to provide a final demand. Using the direct requirements matrix, each element in x is disaggregated into a vector of inputs to the corresponding sector. Energy data from the interventions matrix B is then used to convert the monetary flows of the disaggregated x into physical energy flows. For each energy flow, the origin sector, the destination sector, and the energy carrier type will all be known. These energetic flows are analogous but not identical to direct energy inputs that would appear in a unit process used in life cycle analysis and other bottom-up methods, and thus can be used to evaluate the alignment between the top-down results and the results of a bottom-up model. To demonstrate and further develop the proposed method, embodied energy for chemicals assessed in the 2015 U.S. DOE bandwidth study on energy use within the chemical sector will be calculated using a top-down and a bottom-up model. The Materials Flows through Industry (MFI) modeling tool developed at the National Renewable Energy Laboratory is used as the bottom-up model, and the U.S. EEIO model, recently published by the U.S. Environmental Protection Agency, is used as the top-down model. U.S. EEIO and MFI results will be evaluated to determine how well the model results align. Where the two models are not in good alignment, the disaggregation method described above will be applied to the top-down model to generate a more detailed set of results that will aid in identifying data gaps in the MFI database. Using only MFI, data gaps can be identified in terms of which sectors have few or no unit processes in the database, but no information is available regarding the impact of the missing data on MFI results. The disaggregated top-down results will provide this information on which gaps in the MFI data are critical and have a significant impact on the results, and which are less important.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Appendix B: Commercial Solar Financing Options

As the solar photovoltaic (PV) market in the United States has evolved, so too have the financing mechanisms associated with it. This appendix provides a snapshot of the current commercial solar financing arena and an overview of existing financing mechanisms. While there is significant overlap in solar financing options among the residential, government, and commercial sectors, this report focuses on options and considerations for commercial entities only. Traditional solar financing models are being adapted to encompass increasingly complex relationships between solar energy consumers and solar development. This guide explores the variety of financing options available to commercial entities, ranging from the historical mainstays of the solar financing spectrum - third-party ownership (TPO) models, which include power purchase agreements (PPAs) and leases, in addition to loans and cash purchases - to relatively more recent additions, including property-assessed clean energy (PACE) financing, performance contracting, and green bonds, among others. This appendix ('Appendix B. Commercial Solar Financing Options') is one chapter in the Environmental Protection Agency's broader Guide to Purchasing Green Power, which provides a detailed overview of green power markets and procurement.

14 SOLAR ENERGY↗

Policy, Regulatory, Legal, and Permitting Case Study Subtask 3.2 – Topical Report

This report summarizes the policy, regulatory, legal, and permitting requirements to-date for the siting of a CO 2 injection and storage project in the CarbonSAFE Illinois East Sub-Basin pre-feasibility study area. Where applicable, the East Sub-Basin case study focuses on a proposed carbon capture and storage (CCS) site location in West Terre Haute, Indiana. Indiana has established the legal mechanisms to obtain rights to the subsurface mineral estate with the expectation to apply to reservoir pore space for CO 2 storage in an analogous manner to storage of natural gas, which is a common practice in Indiana. There is, however, no precedent in Indiana to take liability for stored CO 2 . There are currently no Indiana State incentives for CCS, but at the Federal level, tax credits for carbon capture and storage under 26. U.S. Code § 45Q constitute the greatest incentive targeted at CCS projects. The amendment to these credits put forth in the Bipartisan Budget Act (the FUTURE Act) of 2018 substantially increases the per-ton incentive for CCS—from $22.66 per ton in tax year 2017 up to $50 per ton in tax year 2027, for CO 2 not used as an injectant (i.e. saline storage). Additional economic opportunities may exist for the provision of CO 2 for potential EOR in the Illinois Basin. Policies that may support the development of CO 2 pipelines and/or CCS projects in Indiana include: 1) Title 41 of the FAST Act (2015), which created a new governance structure, procedures, and funding authorities in order to improve and expedite Federal review and authorization of covered infrastructure projects, including pipelines, and 2) the Eminent Domain for Transportation of Carbon Dioxide by Pipeline (IC 14-39, Indiana State, 2011), which declares pipeline transportation of CO 2 exclusively to a carbon management application, including sequestration, enhanced oil recovery, and deep saline injection as a benefit to the welfare of Indiana and the people. The US Environmental Protection Agency’s (EPA) Underground Injection Control (UIC) Program Class VI rule and permit requirements address all components pertaining to CO 2 injection and monitoring for long-term storage, and outline the minimum technical criteria to protect underground sources of drinking water at, and surrounding, injection well sites. The Class VI requirements also address financial responsibility for corrective action, post-injection site care, and site closure. In addition, UIC Program public notice requirements include that the EPA issue notice of the draft permit preparation to key stakeholders, and open a public comment period of not less than 30 days. A public hearing about the permit would also be held, if specifically requested by the public. A potential Class VI CO 2 injection well permit for the East Sub-Basin case study site would be obtained through the US EPA Region 5, because the State of Indiana does not have UIC Class VI primacy. Although no CO 2 injection wells have been permitted in Indiana, the US EPA Region 5 (which covers Illinois and Indiana) and the East Sub-Basin CarbonSAFE team (via the Midwest Geological Sequestration Consortium [MGSC]) have Class VI permitting experience from several projects located in Illinois. Based on our experience, applying for a Class VI permit can be an intensive and iterative process requiring clear communication and numerous interactions with EPA staff. In addition to gathering and preparing the data/models and documentation necessary for a permit application’s initial submittal, the subsequent public comments, EPA response and review, and answering of any follow-up questions/requests by the EPA could significantly increase the timeframe of draft permit issuance. The US EPA offers guidance documents regarding the specific Class VI permit requirements, and shows a general permitting timeline example from the FutureGen Alliance 2.0 covering one-and-a-half years from permit submittal to issuance. However, the overall permitting process to-date has a high degree of variability, and in MGSC’s project experience we observed a more extended timeline to receive Class VI permits for each of two CO 2 injection wells.

01 COAL, LIGNITE, AND PEAT↗

High-Quality Home Performance: Arizona's Home Performance with ENERGY STAR (R) Program

Arizona Public Service (APS) has created a high-quality Home Performance with ENERGY STAR (ENERGY STAR) program. In addition to being based on the ENERGY STAR guidelines developed by the U.S. Department of Energy and U.S. Environmental Protection Agency, they have used two other national guideline/standards to improve quality and contractor satisfaction: DOE's Standard Work Specifications for Home Energy Upgrades (SWS) and the Home Performance Coalition's Home Performance Extensible Markup Language (HPXML). As the program found areas for improvement, they worked with their implementer FSL Home Energy Solutions (FSL) to develop a quality assurance (QA) program based on the SWS. They also worked with energy assessment and other software providers to implement HPXML in a program administration software platform. This gave contractors a choice in what energy assessment software they used - each tool allowed in the program exported HPXML seamlessly to the program administration platform. APS worked closely with FSL and contractors to implement the QA program and roll out the software improvements. After implementing the QA program and software, the program saw approximately 15% improvement in measure and work scope quality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE Zero Energy Ready Homes

This article describes the U.S. Department of Energy's Zero Energy Ready Home Program and Housing Innovation Awards. Since 2013, builders around the country have certified over 1,170 homes to the high performance criteria of the DOE Zero Energy Ready Home program. Each year DOE recognizes the best innovators among this group with the DOE Housing Innovation Awards. 2017 winners will be announced at an awards event taking place at the Energy & Environmental Building Alliance (EEBA) high-performance home summit October 10-12, 2017, in Atlanta, Georgia. Twenty-five builders are expected to take home awards and grand award winners in each of the five competition categories will be revealed at the conference. Participating builders represent every climate zone in the country and DOE Zero Energy Ready labeled homes can be found in 34 states. Homes represent the full spectrum of the U.S. construction industry, from affordable to production to custom homes and from single-family detached to duplexes and up to five-story multifamily buildings as well as some retrofit projects have also met the criteria. Every DOE ZER certified home is certified through the ENERGY STAR Certified Homes (Version 3.0, revision 8) program and the U.S. Environmental Protection Agency’s Indoor airPLUS program. Each home must meet the hot water distribution requirements of the EPA’s WaterSense program and the insulation requirements of the 2012 International Energy Conservation Code. If the home has HVAC ducts, they must be installed within the conditioned space of the home. Appliances, exhaust fans, ceiling fans, and most of the lighting should be ENERGY STAR qualified. The DOE Zero Energy Ready Home program also requires homes to have solar electric panels installed or at a minimum to have the conduit and electrical panel space in place for future PV installation, if the home is in a location appropriate for solar power. Homes are constructed with enough energy efficiency built in so that, with a reasonable amount of solar PV panels (i.e., small enough to fit comfortably on the roof), the home could produce enough of its own power to equal the power it uses in a year.

U.S. Department of Energy Building Technologies Pr↗

Automating the Analysis of GHGRP Data Using Python, to Perform Temporal Analysis on Natural Gas Supply Chain Parameters - LCAXIX

This work was presented at the American Center for Life Cycle Assessment 2019 Conference (LCAXIX) in Tucson, AZ on September 24, 2019. Subpart W of the Environmental Protection Agency’s (EPA) Greenhouse Gas Reporting Program (GHGRP) consists of facility level greenhouse gas data for petroleum and natural gas systems that emit 25,000 metric tons or more of GHGs per year. Envirofacts is a tool that provides all publicly available data reported to GHGRP and it can be used to customize and download the data. This is one of the most granular datasets available that can be used to perform a detailed cradle-to-gate Life Cycle Analysis (LCA) of the United States natural gas supply chain. However, as robust as this data is, it is not available in a format that can be analyzed easily, and it is especially difficult to perform a temporal analysis on it. NETL's python script downloads all the .csv files for the desired reporting years from the subpart W of GHGRP.

Rai, Srijana↗

Comparison of Radon Results in 4- Versus 6-Plex Townhouse Units

In this work, to determine whether there were any significant differences in radon frequency between 4-unit (4-plex) and 6- unit (6-plex) multifamily buildings, an analysis was performed on three different populations of townhouses: one located within an Environmental Protection Agency (EPA) Radon Zone 1 site (Population A) and two others, both located in an EPA Radon Zone 3 site (Populations B and C). Within their respective population grouping, all units were two stories, identical in construction and floor plan, and were constructed by the same contractor over a 1- to 2-year period. In addition, each unit had its own separate, ducted forced-air heat pump. Long-term radon testing was performed using alpha track detectors (ATDs) for a period of 180 days. All detectors were placed in accordance with EPA residential sampling protocols (EPA 402-R-92-003) along the centerline of each unit. Followup testing (short-term, 7-day electret) was performed in all units in which the ATD test results were ≥4 pCi/L, and all elevated results were confirmed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nuclear Energy Model Intercomparison Project

This document summarizes the current status and future plans of the Nuclear Model Intercomparison Project. The objectives of this project are to understand how issues central to nuclear energy are modeled in long-term capacity expansion models, to investigate how model structures and input assumptions impact projections for nuclear’s role, to refine model representations of nuclear energy, and to communicate findings to the research community and decision-makers. High-level goals are discussed for each of the four participating model groups: the U.S. Energy Information Administration (EIA), U.S. Environmental Protection Agency (EPA), Electric Power Research Institute (EPRI), and National Renewable Energy Laboratory (NREL). This document summarizes scenarios and assumptions for the model comparison, outcomes from the first workshop, and next steps.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Testing Rod Seal Leakage of a 700 HP Reciprocating Compressor

Methane emissions from reciprocating compressors in the U.S. natural gas industry account for over 72.4 Bcf per year according to a 2006 statement by the United States Environmental Protection Agency. Methane also has a global warming potential 50 times greater than carbon monoxide. Reciprocating compressors are the machinery type with the highest contribution to methane emissions at natural gas transmissions stations. The largest contributing factor comes from the sealing components in the packing components around the piston rod. SwRI, therefore, designed and setup a test loop to perform baseline packing leakage measurements on a four stage 700 HP JGT/4 compressor. The goal was to improve upon current packing leakage models and to compare new seals vs. used seals. The test loop design is described including the limits of operation. The Data Acquisition System (DAQ), including data measurements, is also fully described. The project shows the results of the commissioning process that verified the operation of all the components. Once the loop was commissioned, SwRI performed baseline packing leakage for multiple pressure ratios on each of the four stages of the compressor. The data was collected to develop an analytical model of the packing leakage. Finally, similar testing was performed after replacing the typical rod seal packing with used packing. The used packing leakage was compared to the baseline packing leakage.

03 NATURAL GAS↗

Long-term trends in connected thermostat performance

Internet-connected thermostats (CTs) control heating and cooling systems in about 30% of North American homes, and capture half of annual thermostat sales. In 2017 the U.S. Environmental Protection Agency created a program to certify the performance of ENERGY STAR® Connected Thermostats. To demonstrate compliance with energy-saving criteria, thermostat vendors must submit performance summaries for a representative sample of up to 1250 homes. Vendors must then re-submit results from a new, representative sample every six months in order to maintain their ENERGY STAR certification. This procedure has created a unique record of each thermostat’s long-term performance in response to changes in weather, customer demographics, building stock, and algorithms. Our analysis covers submissions from 13 different vendors, who submitted data up to 7 times over four years. We found that these semi-annual samples generated relatively stable trends for comfort temperatures and Heating, Ventilating and Air Conditioning (HVAC) runtimes over the study period. However, some vendors achieved consistently more energy-conserving comfort temperatures and shorter HVAC runtimes than others. The most recent submission runtimes averaged 700 hours for heating and 1,300 hours for cooling, but some vendors achieved runtimes as much as 17% below the mean. This implies lower energy consumption is due in large part to more successful algorithms and control strategies used by those vendors.

Meier, Alan↗

Waste Reduction Network Waste Glossary

This document contains relevant industry definitions to support partners in the Better Buildings, Better Plants Waste Reduction Network. Definitions were compiled using the CalRecycle Glossary, SWANA’s Waste Glossary, the U.S. Environmental Protection Agency, the State of Washington’s Department of Ecology, the Ellen MacArthur Foundation, and Metro Oregon. Some terms contain multiple complementary definitions.

Better Buildings, waste glossary, compost, waste d↗