Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Digital signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Validating uPSP with Transducers

Unsteady Pressure-Sensitive Paint (uPSP) technology provides simultaneously high-frequency and high-spatial resolution surface pressure fluctuation measurements. It has demonstrated value in wind tunnel test facilities to evaluate aerospace vehicle unsteady aerodynamics. The calibration of measurements from digital pixel counts into corresponding physical units relies on both lab-based and in-situ calibration steps, and its validation is both challenging and critical to adoption of the technology. We present a rigorous methodology for direct comparison of uPSP-derived surface pressure measurements to reference pressure transducer data based on a model of the camera-based measurement error, a model of the flow field pressure signal, and their propagation through the uPSP data reduction algorithm. The methodology is demonstrated on data collected in a small-scale, subsonic wind tunnel test as well as data collected from a Space Launch System unsteady aerodynamics characterization test at the NASA Ames Research Center Unitary Plan Wind Tunnel Complex.

Pressure-Sensitive Paint↗

Production and tests of the ADDC for the Micromegas detector of the ATLAS New Small Wheel

The Large Hadron Collider (LHC) at CERN will perform a series of upgrades to allow luminosity increases during the next physics runs expected from 2022 on. These will also significantly increase the trigger rates of all the detectors. As part of the ATLAS Phase-I upgrade, the current Small Wheel muon detectors will be replaced with state-of-the-art New Small Wheel (NSW) detectors to cope with the increased luminosity of the LHC. The Address in Real Time Data Driver Card (ADDC) is designed to transmit the trigger data from the resistive Micro-Mesh Gaseous Structure (Micromegas) detectors of the NSW. The ART ASIC on the ADDC is a customdesigned chip to receive theAddress in Real Time (ART) signals from theVMMfront-end ASIC and perform hit-selection processing. The processed trigger data is then sent to the Trigger Processor (TP) through optical links. A total of 512 ADDCs will be installed on the detector close to the front-end boards. Therefore, those cards must be able to work properly in a high radiation and magnetic field environment. Furthermore, after four rounds of prototyping, the ADDC production was launched in January of 2019. 600 ADDC boards have been produced and tested with an automated test stand. This test setup can simulate the front-end signals and provide "Level-1 Data Driver Card" (L1DDC) functions as well as part of the TP functions. Thus, the ADDC functionality and stability can be verified without the remaining NSW electronics. This paper describes the ADDC hardware prototype development, radiation and integration testing, and the ADDC automated production test procedure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Persistent, “Mysterious” Seismoacoustic Signals Reported in Oklahoma State during 2019

Here, we report on the source of seismoacoustic pulses that were observed across the state of Oklahoma (OK) during summer of 2019, and the subject of national media coverage and speculation. Seismic network data collected across four U.S. states and interviews with witnesses to the pulse’s effect on residential structures demonstrate that they were triggered by routine ammunition disposal operations conducted by McAlester Army Ammunition Plant (McAAP). During these operations, conventional explosives destroy obsolete munitions stored in pits through a controlled sequence of electronically timed shots that occur over tens of minutes. Despite noise-abatement efforts that reduce coupling of acoustic energy with air, some lower frequency, subaudible (infrasonic) sound radiates from these shots as discrete pulses. We use nine months of blast log documents, seismic network records, analyst picks, and physical modeling to demonstrate that seismic stations as far as 640 km from McAAP sample these pulses, which record seasonal patterns in stratospheric and tropospheric winds, as well as the dynamic formation of waveguides and shadow zones. Digital short-term average to long-term average detectors that we augment with dynamic thresholds and time-binning operations identify these pulses with a fair probability, when compared with visual observations. Our analyses thereby provide estimates of observation rates for both partial and full sequences of these pulses, as well as single shots. We suggest that disposal operations can exploit existing, composite seismic networks to predict where residents are likely to witness blasting. Crucially, our data also show that dense seismic networks can record multiscale atmospheric processes in the absence of infrasound arrays.

58 GEOSCIENCES↗

Field Micrometeorological Measurements, Process-Level Studies and Modeling of Methane and Carbon Dioxide Fluxes in a Boreal Wetland Ecosystem

The main instrumentation platform consisted of eddy correlation sensors mounted on a scaffold tower at a height of 4.2 m above the peat surface. The sensors were attached to a boom assembly which could be rotated into the prevailing winds. The boom assembly was mounted on a movable sled which, when extended, allowed sensors to be up to 2 m away from the scaffolding structure to minimize flow distortion. When retracted, the sensors could easily be installed, serviced or rotated. An electronic level with linear actuators allowed the sensors to be remotely levelled once the sled was extended. Two instrument arrays were installed. A primary (fast-response) array consisted of a three-dimensional sonic anemometer, a methane sensor (tunable diode laser spectrometer), a carbon dioxide/water vapor sensor, a fine wire thermocouple and a backup one-dimensional sonic anemometer. The secondary array consisted of a one-dimensional sonic anemometer, a fine wire thermocouple and a Krypton hygrometer. Descriptions of these sensors may be found in other reports (e.g., Verma; Suyker and Verma). Slow-response sensors provided supporting measurements including mean air temperature and humidity, mean horizontal windspeed and direction, incoming and reflected solar radiation, net radiation, incoming and reflected photosynthetically active radiation (PAR), soil heat flux, peat temperature, water-table elevation and precipitation. A data acquisition system (consisting of an IBM compatible microcomputer, amplifiers and a 16 bit analog-to-digital converter), housed in a small trailer, was used to record the fast response signals. These signals were low-pass filtered (using 8-pole Butterworth active filters with a 12.5 Hz cutoff frequency) and sampled at 25 Hz. Slow-response signals were sampled every 5 s using a network of CR21X (Campbell Scientific, Inc., Logan Utah) data loggers installed in the fen. All signals were averaged over 30-minute periods (runs).

Verma, S. B.↗

On Certain Theoretical Developments Underlying the Hilbert-Huang Transform

One of the main traditional tools used in scientific and engineering data spectral analysis is the Fourier Integral Transform and its high performance digital equivalent - the Fast Fourier Transform (FFT). Both carry strong a-priori assumptions about the source data, such as being linear and stationary, and of satisfying the Dirichlet conditions. A recent development at the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC), known as the Hilbert-Huang Transform (HHT), proposes a novel approach to the solution for the nonlinear class of spectral analysis problems. Using a-posteriori data processing based on the Empirical Mode Decomposition (EMD) sifting process (algorithm), followed by the normalized Hilbert Transform of the decomposed data, the HHT allows spectral analysis of nonlinear and nonstationary data. The EMD sifting process results in a non-constrained decomposition of a source real-value data vector into a finite set of Intrinsic Mode Functions (IMF). These functions form a nearly orthogonal derived from the data (adaptive) basis. The IMFs can be further analyzed for spectrum content by using the classical Hilbert Transform. A new engineering spectral analysis tool using HHT has been developed at NASA GSFC, the HHT Data Processing System (HHT-DPS). As the HHT-DPS has been successfully used and commercialized, new applications pose additional questions about the theoretical basis behind the HHT and EMD algorithms. Why is the fastest changing component of a composite signal being sifted out first in the EMD sifting process? Why does the EMD sifting process seemingly converge and why does it converge rapidly? Does an IMF have a distinctive structure? Why are the IMFs nearly orthogonal? We address these questions and develop the initial theoretical background for the HHT. This will contribute to the development of new HHT processing options, such as real-time and 2-D processing using Field Programmable Gate Array (FPGA) computational resources,

Kizhner, Semion↗

On the Hilbert-Huang Transform Theoretical Developments

One of the main heritage tools used in scientific and engineering data spectrum analysis is the Fourier Integral Transform and its high performance digital equivalent - the Fast Fourier Transform (FFT). Both carry strong a-priori assumptions about the source data, such as linearity, of being stationary, and of satisfying the Dirichlet conditions. A recent development at the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC), known as the Hilbert-Huang Transform (HHT), proposes a novel approach to the solution for the nonlinear class of spectrum analysis problems. Using a-posteriori data processing based on the Empirical Mode Decomposition (EMD) sifting process (algorithm), followed by the normalized Hilbert Transform of the decomposition data, the HHT allows spectrum analysis of nonlinear and nonstationary data. The EMD sifting process results in a non-constrained decomposition of a source real value data vector into a finite set of Intrinsic Mode Functions (IMF). These functions form a near orthogonal adaptive basis, a basis that is derived from the data. The IMFs can be further analyzed for spectrum interpretation by the classical Hilbert Transform. A new engineering spectrum analysis tool using HHT has been developed at NASA GSFC, the HHT Data Processing System (HHT-DPS). As the HHT-DPS has been successfully used and commercialized, new applications post additional questions about the theoretical basis behind the HHT and EMD algorithms. Why is the fastest changing component of a composite signal being sifted out first in the EMD sifting process? Why does the EMD sifting process seemingly converge and why does it converge rapidly? Does an IMF have a distinctive structure? Why are the IMFs near orthogonal? We address these questions and develop the initial theoretical background for the HHT. This will contribute to the developments of new HHT processing options, such as real-time and 2-D processing using Field Programmable Array (FPGA) computational resources, enhanced HHT synthesis, and broaden the scope of HHT applications for signal processing.

Kizhner, Semion↗

Methodology for Validation of Unsteady Pressure-Sensitive Paint Measurements using Pressure Transducers

Unsteady Pressure-Sensitive Paint (uPSP) technology provides simultaneously high-frequency and high-spatial resolution surface pressure fluctuation measurements. It has demonstrated value in wind tunnel test facilities to evaluate aerospace vehicle unsteady aerodynamics. The calibration of measurements from digital pixel counts into corresponding physical units relies on both lab-based and in-situ calibration steps, and its validation is both challenging and critical to adoption of the technology. We present a rigorous methodology for direct comparison of uPSP-derived surface pressure measurements to reference pressure transducer data based on a model of the camera-based measurement error, a model of the flow field pressure signal, and their propagation through the uPSP data reduction algorithm. The methodology is demonstrated on data collected in a small-scale, subsonic wind tunnel test as well as data collected from a Space Launch System unsteady aerodynamics characterization test at the NASA Ames Research Center Unitary Plan Wind Tunnel Complex.

Pressure-Sensitive Paint↗

The HYDICE instrument design and its application to planetary instruments

The Hyperspectral Digital Imagery Collection Experiment (HYDICE) instrument represents a significant advance in the state of the art in hyperspectral sensors. It combines a higher signal-to-noise ratio (SNR) and significantly better spatial and spectral resolution and radio metric accuracy than systems flying on aircraft today. The need for 'clean' data, i.e., data free of sampling artifacts and excessive spatial or spectral noise, is a key driver behind the difficult combination of performance requirements laid out for HYDICE. Most of these involve the sensor optics and detector. This paper presents an optimized approach to those requirements, one that comprises push broom scanning, a single, mechanically cooled focal plane, a double-pass prism spectrometer, and an easily fabricated yet wide-field telescope. Central to the approach is a detector array that covers the entire spectrum from 0.4 to 2.5 microns. Among the major benefits conferred by such a design are optical and mechanical simplicity, low polarization sensitivity, and coverage of the entire spectrum without suffering the spectral gaps caused by beam splitters. The overall system minimizes interfaces to the C-141 aircraft on which it will be flown, can be calibrated on the ground and in flight to accuracies better than those required, and is designed for simple, push-button operation. Only unprocessed data are recorded during flight. A ground data processing station provides quick-look, calibration correction, and archiving capabilities, with a throughput better than the requirements. Overall performance of the system is expected to provide the solid database required to evaluate the potential of hyperspectral imagery in a wide variety of applications. HYDICE can be regarded as a test bed for future planetary instruments. The ability to spectrally image a wide field of view over multiple spectral octaves offers obvious advantages and is expected to maximize science return for the required cost and weight.

Basedow, R.↗

The ETROC2 as the Final Version for CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD (Low Gain Avalanche Diodes) silicon devices, read out by ETROCs for precision timing measurement with down to ~30 ps timing resolution per track. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. The front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile. The ETROC chip is implemented in a commercial 65nm CMOS process. Each channel consists of a preamplifier, a discriminator, a TDC used for TOA (Time Of Arrival) and TOT (Time Over Threshold) measurements, and a memory for data storage and readout. An in-pixel auto threshold calibration is included, along with a self-testing pattern generator. The TOT is used for time-walk correction of the TOA measurement. The detailed hit information (TOA and TOT) from each cell will be read out from a local circular buffer after each Level-1 Accept (about 1 MHz). In addition, a charge injection circuit is implemented to allow for testing and calibration. For more detailed monitoring of the signal pulses, waveform sampling circuits are included for one pixel. The clock distribution is based on a 16x16 H-tree design with a shielding structure to alleviate potential interference. The global peripheral circuits include a PLL, a phase shifter, an I2C slave controller, a fast control block, a global readout, and a data driver along with an efuse and temperature sensor. The ETROC builds event data frames for each L1A selected event and is also capable of providing L1 trigger information for user-defined delayed hits. The main design challenge is how to extract precision timing information from the small LGAD signals in the presence of high irradiation fluence, while keeping the power consumption and digital activity low. The ETL design goal for the time resolution of 50 ps per hit is required to achieve a 35 ps arrival time measurement for a MIP particle, which has its track registered in two ETL disk layers. The LGAD contribution is known to be about 30 ps, this means that the jitter from the ETROC has to be kept below 40 ps. The ETROC2 is the first full size full functionality prototype design fully compatible with the final chip specifications for CMS ETL and now becomes the final version. The ETROC2 chips have been extensively tested. We will present here new testing results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with one pixel TWC applying to all pixels, the final SEU testing using both heavy ion and proton beam, more beam test studies including different sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tiehui [Fermilab] (ORCID:0009000765225605)↗

Video Skimming and Characterization through the Combination of Image and Language Understanding Techniques

Digital video is rapidly becoming important for education, entertainment, and a host of multimedia applications. With the size of the video collections growing to thousands of hours, technology is needed to effectively browse segments in a short time without losing the content of the video. We propose a method to extract the significant audio and video information and create a "skim" video which represents a very short synopsis of the original. The goal of this work is to show the utility of integrating language and image understanding techniques for video skimming by extraction of significant information, such as specific objects, audio keywords and relevant video structure. The resulting skim video is much shorter, where compaction is as high as 20:1, and yet retains the essential content of the original segment.

IMAGE PROCESSING↗

The impact of detection rate changes and correlations on random-coincidence background measurements

Coincidence detection of multiple particles emitted during an experiment can yield a new depth of understanding of the underlying process under study. However, the probability of detecting particles that are generated from the same physical event within a given coincidence time window is generally much lower than that of detecting particles that appear in the same coincidence time window, but were not created from the same physical event, and are therefore detected randomly in coincidence with each other. Thus, accurate and precise methods of measuring this random-coincidence background are essential for a wide variety of fields of science. A method to determine this background directly using the data themselves without any additional experimental run time or fake signals introduced in the data was recently established (O’Donnell, 2016). This method yields a statistical uncertainty on the random-coincidence background that is orders of magnitude smaller than that of the true coincidence data, though the potential for systematic errors of backgrounds from this method was never explored. In this work, we discuss common varieties of correlated and uncorrelated changes in the detection rates of each particle detected in an experiment. Here we demonstrate here that a correlation between particle detection rates from, for example, an incident particle beam that initiates a physical process of interest, creates systematic errors in the random-coincidence background measurement. We also discuss the impact of a variety of other realistic scenarios for rate changes in experiments. Lastly, a method is introduced to correct for errors in the random-coincidence background from any source, yielding an optimization between statistical precision and eliminating potential lingering systematic errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NASA Tech Briefs, November 2008

Topics covered include: Digital Phase Meter for a Laser Heterodyne Interferometer; Vision System Measures Motions of Robot and External Objects; Advanced Precipitation Radar Antenna to Measure Rainfall From Space; Wide-Band Radar for Measuring Thickness of Sea Ice; Vertical Isolation for Photodiodes in CMOS Imagers; Wide-Band Microwave Receivers Using Photonic Processing; L-Band Transmit/Receive Module for Phase-Stable Array Antennas; Microwave Power Combiner/Switch Utilizing a Faraday Rotator; Compact Low-Loss Planar Magic-T; Using Pipelined XNOR Logic to Reduce SEU Risks in State Machines; Quasi-Optical Transmission Line for 94-GHz Radar; Next Generation Flight Controller Trainer System; Converting from DDOR SASF to APF; Converting from CVF to AAF; Documenting AUTOGEN and APGEN Model Files; Sequence History Update Tool; Extraction and Analysis of Display Data; MRO DKF Post-Processing Tool; Rig Diagnostic Tools; MRO Sequence Checking Tool; Science Activity Planner for the MER Mission; UAVSAR Flight-Planning System; Templates for Deposition of Microscopic Pointed Structures; Adjustable Membrane Mirrors Incorporating G-Elastomers; Hall-Effect Thruster Utilizing Bismuth as Propellant; High-Temperature Crystal-Growth Cartridge Tubes Made by VPS; Quench Crucibles Reinforced with Metal; Deep-Sea Hydrothermal-Vent Sampler; Mars Rocket Propulsion System; Two-Stage Passive Vibration Isolator; Improved Thermal Design of a Compression Mold; Enhanced Pseudo-Waypoint Guidance for Spacecraft Maneuvers; Altimetry Using GPS-Reflection/Occultation Interferometry; Thermally Driven Josephson Effect; Perturbation Effects on a Supercritical C7H16/N2 Mixing Layer; Gold Nanoparticle Labels Amplify Ellipsometric Signals; Phase Matching of Diverse Modes in a WGM Resonator; WGM Resonators for Terahertz-to-Optical Frequency Conversion; Determining Concentration of Nanoparticles from Ellipsometry; Microwave-to-Optical Conversion in WGM Resonators; Four-Pass Coupler for Laser-Diode-Pumped Solid-State Laser; Low-Resolution Raman-Spectroscopy Combustion Thermometry; Temperature Sensors Based on WGM Optical Resonators; Varying the Divergence of Multiple Parallel Laser Beams; Efficient Algorithm for Rectangular Spiral Search; Algorithm-Based Fault Tolerance Integrated with Replication; Targeting and Localization for Mars Rover Operations; Terrain-Adaptive Navigation Architecture; Self-Adjusting Hash Tables for Embedded Flight Applications; Schema for Spacecraft-Command Dictionary; Combined GMSK Communications and PN Ranging; System-Level Integration of Mass Memory; Network-Attached Solid-State Recorder Architecture; Method of Cross-Linking Aerogels Using a One-Pot Reaction Scheme; An Efficient Reachability Analysis Algorithm.

Source record↗

Hydra Rendezvous and Docking Sensor

The U.S. technology to support a CEV AR&D activity is mature and was developed by NASA and supporting industry during an extensive research and development program conducted during the 1990's and early 2000 time frame at the Marshall Space Flight Center. Development and demonstration of a rendezvous/docking sensor was identified early in the AR&D Program as the critical enabling technology that allows automated proxin~ity operations and docking. A first generation rendezvous/docking sensor, the Video Guidance Sensor (VGS) was developed and successfully flown on STS 87 and again on STS 95, proving the concept of a video-based sensor. Advances in both video and signal processing technologies and the lessons learned from the two successful flight experiments provided a baseline for the development of a new generation of video based rendezvous/docking sensor. The Advanced Video Guidance Sensor (AVGS) has greatly increased performance and additional capability for longer-range operation. A Demonstration Automatic Rendezvous Technology (DART) flight experiment was flown in April 2005 using AVGS as the primary proximity operations sensor. Because of the absence of a docking mechanism on the target satellite, this mission did not demonstrate the ability of the sensor to co~ltrold ocking. Mission results indicate that the rendezvous sensor operated successfully in "spot mode" (2 km acquisition of the target, bearing data only) but was never commanded to "acquire and track" the docking target. Parts obsolescence issues prevent the construction of current design AVGS units to support the NASA Exploration initiative. This flight proven AR&D technology is being modularized and upgraded with additional capabilities through the Hydra project at the Marshall Space Flight Center. Hydra brings a unique engineering approach and sensor architecture to the table, to solve the continuing issues of parts obsolescence and multiple sensor integration. This paper presents an approach to sensor hardware trades, to address the needs of future vehicles that may rendezvous and dock with the International Space Station (ISS). It will also discuss approaches for upgrading AVGS to address parts obsolescence, and concepts for modularizing the sensor to provide configuration flexibility for multiple vehicle applications. Options for complementary sensors to be integrated into the multi-head Hydra system will also be presented. Complementary sensor options include ULTOR, a digital image correlator system that could provide relative six-degree-of-freedom information independently from AVGS, and time-of-flight sensors, which determine the range between vehicles by timing pulses that travel from the sensor to the target and back. Common targets and integrated targets, suitable for use with the multi-sensor options in Hydra, will also be addressed.

Roe, Fred↗

The NASA Spacecraft Transponding Modem

A new deep space transponder is being developed by the Jet Propulsion Laboratory for NASA. The Spacecraft Transponding Modem (STM) implements the standard transponder functions and the channel service functions that have previously resided in spacecraft Command/Data Subsystems. The STM uses custom ASICs, MMICs, and MCMs to reduce the active device parts count to 70, mass to I kg, and volume to 524 cc. The first STMs will be flown on missions launching in the 2003 time frame. The STM tracks an X-band uplink signal and provides both X-band and Ka-band downlinks, either coherent or non-coherent with the uplink. A NASA standard Command Detector Unit is integrated into the STM, along with a codeblock processor and a hardware command decoder. The decoded command codeblocks are output to the spacecraft command/data subsystem. Virtual Channel 0 (VC-0) (hardware) commands are processed and output as critical controller (CRC) commands. Downlink telemetry is received from the spacecraft data subsystem as telemetry frames. The STM provides the following downlink coding options: the standard CCSDS (7-1/2) convolutional coding, ReedSolomon coding with interleave depths one and five, (15-1/6) convolutional coding, and Turbo coding with rates 1/3 and 1/6. The downlink symbol rates can be linearly ramped to match the G/T curve of the receiving station, providing up to a 1 dB increase in data return. Data rates range from 5 bits per second (bps) to 24 Mbps, with three modulation modes provided: modulated subcarrier (3 different frequencies provided), biphase-L modulated direct on carrier, and Offset QPSK. Also, the capability to generate one of four non-harmonically related telemetry beacon tones is provided, to allow for a simple spacecraft status monitoring scheme for cruise phases of missions. Three ranging modes are provided: standard turn around ranging, regenerative pseudo-noise (PN) ranging, and Differential One-way Ranging (DOR) tones. The regenerative ranging provides the capability of increasing the ground received ranging SNR by up to 30 dB. Two different avionics interfaces to the command/data subsystem's data bus are provided: a MIL STD 1553B bus or an industry standard PCI interface. Digital interfaces provide the capability to control antenna selection (e.g., switching between high gain and low gain antennas) and antenna pointing (for future steered Ka-band antennas).

Berner, Jeff B.↗

Unlocking the Mysteries of the Moon’s Shadowed Regions

The Moon poles host large quantities of water-ice deposits in the permanently shadowed regions (PSRs), which are vital for enabling sustainable human space exploration, making these regions high-priority targets for upcoming Artemis missions [1]. Unfortunately, today, the best available orbital lunar imagery [2, 3] lacks the meter-scale resolution and signal needed to understand the geomorphology and trafficability of PSRs, complicating the planning and execution of future missions seeking to explore PSRs. We have developed an image enhancement tool called HORUS (Hyper-effective nOise Removal Unet Software) [4, 5], designed to enhance LRO Narrow-Angle Camera (NAC) optical low-light imagery of permanently shadowed regions by effectively removing the CCD-related, photon, and other residual noises that corrupt the images. The tool is composed of two deep learning neural networks trained on environmental metadata and real and synthetic imagery, the latter generated by a physical noise model (LROC). We demonstrated that HORUS effectively produces low-noise, high-resolution images (~1.5m/px), achieving a 5 to 10x improvement over existing long-exposure images of PSRs. HORUS allows scientists and engineers to identify geomorphic features (e.g., craters and boulders) in shadowed regions as small as 3 meters across as well as to peek inside of small shadowed regions, for the first time. The tool was deployed and thoroughly validated for NASA's VIPER mission [6], where it was applied to 20 candidate target regions across the lunar South Pole. Additionally, we conducted different approaches to validate the resulting HORUS-processed images. With HORUS denoised images, VIPER scientists can increase their confidence on what surface features (previously unseen) exist in the shadowed regions, helping them plan rover traverses more safely and efficiently (e.g., Fig. 1) In this manuscript, we will describe how VIPER scientists are utilizing HORUS denoised images to extract new information from the terrain and increase their confidence in what surface features exist in the shadowed regions. In combination with other high-resolution images and digital elevation maps, HORUS images are helping the team analyze potential lading and science sites, as well as planning traverses more safely and efficiently (e.g., Fig. 1). Additionally, we will describe how HORUS tool unlocks a broad range of scientific and exploration applications to other Artemis and CPLS missions to the lunar poles, including (but not limited to) geomorphic analysis, change detection, surface hazard detection, and terrain relative navigation.

artificial intelligence↗

Brain segmentation and the generation of cortical surfaces

This paper describes methods for white matter segmentation in brain images and the generation of cortical surfaces from the segmentations. We have developed a system that allows a user to start with a brain volume, obtained by modalities such as MRI or cryosection, and constructs a complete digital representation of the cortical surface. The methodology consists of three basic components: local parametric modeling and Bayesian segmentation; surface generation and local quadratic coordinate fitting; and surface editing. Segmentations are computed by parametrically fitting known density functions to the histogram of the image using the expectation maximization algorithm [DLR77]. The parametric fits are obtained locally rather than globally over the whole volume to overcome local variations in gray levels. To represent the boundary of the gray and white matter we use triangulated meshes generated using isosurface generation algorithms [GH95]. A complete system of local parametric quadratic charts [JWM+95] is superimposed on the triangulated graph to facilitate smoothing and geodesic curve tracking. Algorithms for surface editing include extraction of the largest closed surface. Results for several macaque brains are presented comparing automated and hand surface generation. Copyright 1999 Academic Press.

NASA Discipline Neuroscience↗

Seismic Study of the Dynamics of the Solar Subsurface from SoHO Observations

In collaboration with Dr. Baudin, we have developed and refined the new observational methodology for local helioseismology known as time-distance analysis. Global helioseismology study the solar oscillations as a superposition of resonant modes, whose properties (mode frequencies) reflect the global structure of the sun (sound speed stratification, rotation rate, etc). In contrast, local helioseismology look at the solar oscillations as wave packets whose propagation will be affected by perturbations of the media sampled. These local perturbations (sound speed or velocity flows) will modify the propagation time, that in turn can be used as a diagnostic tool for a given region. From a data reduction perspective, the processing of solar dopplergrams that result in time-distance maps, i.e. propagation times as a function of distance between bounces at the surface, is radically different from the methodology used for global mode analysis. We have, in a first step, further develop the programs needed to carry out such analysis. We have then applied them to NMI data set, and explore the trade-off between various averaging and filtering approaches - steps required to improve the signal-to-noise ratio of correlation maps - and the resulting stability and precision of the fitted propagation times. While excessive averaging (whether over space, propagation distance, or time) will reduce the diagnostic potential of the method, insufficient averaging lead to unstable fits, or uncertainties so large as to hide the information we seek. In a second phase, we have developed the analysis methodology required to infer local properties from perturbation in time propagation. Namely, we have developed time-distance inversion techniques, with an emphasis on inferences of velocity flows from time anomalies. Note also that during the period covered by this grant, all the investigators on this proposal (i.e., Drs. Baudin, Eff-Darwich, Korzennik, and Noyes) took part in the organization of the SOHO 6 /GONG 99 Workshop: Structure and Dynamics of the Interior of the Sun and Sunlike Stars, held on June 1-4 1999 at the Boston Park Plaza Hotel in Boston, Massachusetts, USA. it was very well attended by more than 160 participants from 26 countries from all over the world. The proceedings were published in two volumes as ESA SP-418, with Sessions I-III in Volume 1, and Sessions IV-VI in Volume 2 (1,000 pages in total). The complete contents are also included in digital form on a CD-ROM included with Volume 1. This CD-ROM also contains additional multi-media material that complements some of the contributions.

Korzennik, Sylvain G.↗

The Biolink Implantable Telemetry System

Most biotelemetry applications deal with the moderated data rates of biological signals. Few people have studied the problem of transcutaneous data transmission at the rates required by NASA's Life Sciences-Advanced BioTelemetry System (LS-ABTS). Implanted telemetry eliminate the problems associated with wire breaking the skin, and permits experiments with awake and unrestrained subjects. Our goal is to build a low-power 174-216MHz Radio Frequency (RF) transmitter suitable for short range biosensor and implantable use. The BioLink Implantable Telemetry System (BITS) is composed of three major units: an Analog Data Module (ADM), a Telemetry Transmitter Module (TTM), and a Command Receiver Module (CRM). BioLink incorporates novel low-power techniques to implement a monolithic digital RF transmitter operating at 100kbps, using quadrature phase shift keying (QPSK) modulation in the 174-216MHz ISM band. As the ADM will be specific for each application, we focused on solving the problems associated with a monolithic implementation of the TTM and CRM, and this is the emphasis of this report. A system architecture based on a Frequency-Locked Loop (FLL) Frequency Synthesizer is presented, and a novel differential frequency that eliminates the need for a frequency divider is also shown. A self sizing phase modulation scheme suitable for low power implementation was also developed. A full system-level simulation of the FLL was performed and loop filter parameters were determined. The implantable antenna has been designed, simulated and constructed. An implant package compatible with the ABTS requirements is also being proposed. Extensive work performed at 200MHz in 0.5um complementary metal oxide semiconductors (CMOS) showed the feasibility of integrating the RF transmitter circuits in a single chip. The Hajimiri phase noise model was used to optimize the Voltage Controlled Oscillator (VCO) for minimum power consumption. Two test chips were fabricated in a 0.5pm, 3V CMOS process. Measured phase noise for a 1.5mW, 200MHz ring oscillator VCO is -80dBc/Hz at 100KHZ offset, showing good agreement with the theory. We also propose a novel superregenerative receiver architecture for implementing the command receiver. The superregenerative receiver's simplicity, low cost, and low power consumption has made it the receiver of choice for short-distance data communications, remote control and home automation. We present the design of a superregenerative AM receiver implemented in a 0.5um CMOS technology that operates at 433.92MHz and dissipates only 300uW. Further work entails detailed transistor-level design of the FLL and superregenerative receiver and a monolithic implementation of an implantable transceiver in 0.5um CMOS technology.

Betancourt-Zamora, Rafael J.↗