SEARCH · Engineering Papers
Results for “Device”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Understanding Recombination Pathways of CdSeTe/CdTe Devices Using Temperature Dependence of Fill Factor
Understanding the temperature dependence of photovoltaic parameters is critical for identifying performance limiting mechanisms in CdTe-based solar cells. In this study, we investigate the temperature dependence of fill factor (FF(T)) in CdSeTe/CdTe solar cells using a combination of experimental current density-voltage (JV) measurements and numerical simulations. The measured FF(T) exhibits a nonlinear response with temperature, peaking at moderate temperature values (10–30°C). Through numerical modeling, we reveal that this peaking behavior in FF(T) arises when the dominant recombination mechanism transitions from bulk to interface with increasing temperature. This transition is primarily driven by low hole mobility (0.6–1.2 cm2/V·s), while electron mobility, interface recombination velocities, and carrier lifetime also contribute to the effect. Our findings demonstrate that FF(T) analysis is a promising diagnostic tool for distinguishing recombination pathways and guiding the optimization of thin-film CdTe solar cells under real-world conditions.
Comparison of SAR distribution of hip and knee implantable devices in 1.5T conventional cylindrical-bore and 1.2T open-bore vertical MRI systems
Not provided.
Full Device Evaluation of Metal Halide Perovskite Solar Cells in Low Earth Orbit Aboard the International Space Station
This study investigates how sustained low Earth orbit (LEO) exposure affects metal halide perovskite (MHP) thin films and perovskite solar cells (PSCs). It examines samples deployed on the Materials International Space Station Experiment (MISSE) 15 and 16 missions. Five methylammonium lead iodide (MAPI) thin films are deployed on MISSE-16, each with distinct UV filters to selectively attenuate AM0 spectral bands. While post-flight optical analysis reveals that the least UV-exposed film exhibits the highest emission and lowest non-radiative recombination rate, no clear correlation is observed among the rest, and all MAPI films maintained excellent integrity throughout the mission. MISSE-15 deployed eight PSCs with diverse structures, MHP compositions, and contact materials. Post-flight analysis reveals stable, highly emissive MHPs, but damaged contacts due to ion migration, which caused loss of electrical response. The MISSE missions demonstrate MHPs' suitability for space applications, while highlighting the need for improved interfacial layers and contact materials to enhance charge carrier mobility, prevent ion migration, and improve charge carrier extraction efficiency.
Topology optimization for the full-cell design of porous electrodes in electrochemical energy storage devices
In this paper, we introduce a density-based topology optimization framework to design porous electrodes for maximum energy storage. We simulate the full cell with a model that incorporates electronic potential, ionic potential, and electrolyte concentration. The system consists of three materials, namely pure liquid electrolyte and the porous solids of the anode and cathode, for which we determine the optimal placement. We use separate electronic potentials to model each electrode, which allows interdigitated designs. As a result, a penalization is required to ensure that the anode and cathode do not touch, i.e., causing a short circuit. We compare multiple 2D designs generated for different fixed conditions, e.g. material properties. A 3D design with complex channel and interlocked structure is also created. All optimized designs are far superior to the traditional monolithic electrode design with respect to energy storage metrics. We observe up to a 750% increase in energy storage for cases with slow effective ionic diffusion within the porous electrode.
Insights into the performance of InAs-based devices in extreme environments from multiscale simulations
Not provided.
High-permittivity dielectric edge termination for vertical high voltage devices
Not provided.
Active Lithium Injection for a Real Time Control of the Divertor Heat Flux for Fusion Devices
When the local heat flux exceeds specified flux limit, tungsten PFC surfaces can be damaged, which is not acceptable for a reliable reactor operations. The divertor PFCs are typically designed for a specific heat flux limit usually assuming an average steady-state heat flux which is typically 5–10 MW/m 2 . However, in addition to steady-state heat flux, fusion reactor divertor PFCs could experience transient heat fluxes such as ELMs and/or other magnetic reconnection events which can deposit large transient heat fluxes onto the divertor PFCs. The transient divertor heat flux could be significantly larger than the steady-state heat flux which could damage the solid PFC surfaces. The divertor heat flux can be subjected to additional complications such as the uncertainties in the the divertor strike point heat flux projection. Moreover, there are additional experimental observations of non-axisymmetric power flux which can occur under non-axisymmetric magnetic perturbations. The liquid lithium (LL) PFCs is more resilient against such transient heat fluxes as they could evaporate LL as needed and the lost LL can be then replenished afterward. In this paper, we analyze a case for a transient divertor heat pulse of 1 MJ in 10 ms for a ITER-size reactor. This is a small perturbation (~ 0.1%) to the expected plasma stored energy compared to the previously analyzed case of 20 MJ heat pulse. Even with this relatively modest heat pulse, the LL surface undergoes ~ 100 °C temperature rise. However, the resulting LL surface heating without rapid cooldown mechanism could lead to excessive LL evaporation continuing well after the transient heat flux resulting in a significant Li injection of ~ 0.6 mol in about a 200 ms period. This amount of Li injection could cause plasma dilution and performance degradation. On the other hand, an active Li injection capability if optimized could prevent the LL surface temperature rise and thus reducing subsequent Li evaporation into the plasma by a factor of 7 compared to the passive LL PFC case. A crucial tool of active Li injection is a rapid response pellet injector which could inject light impurity pellets before the excessive heat flux could reach the divertor plate causing serious damage. A simple pellet ablation model suggests a favorable pellet deposition profile for smaller ~ 0.1 mm radius pellet with ~ 10–20 m/s velocity. Moreover, if it is possible to inject from the private flux region, the pellet injection efficiency into the high heat flux strike point region can be as high as 80% compared to ~ 50% for the injection from outer radius region. The pellet deposition efficiency can be further improved by designing a shell-pellet which can burst when a certain ablation fraction is reached. Finally, a possible implementation technique using an inductive pellet injector with a rapid time response of a few msec is proposed here which can be tested in NSTX-U.
Devices for Thermal Conductivity Measurements of Electroplated Bi for X-ray TES Absorbers
Electroplated bismuth (Bi) is commonly used in transition-edge sensors (TESs) for X-rays because of its high stopping power and low heat capacity (Collan in Phys Rev B 1:2888, 1970, Yan in Appl Phys Lett 111:192602, 2017). Electroplated Bi is usually grown on top of another metal that acts as seed layer, typically gold (Au), making it challenging to extrapolate its thermoelectric properties. In this work, we present four-wire resistance measurement structures that allow us to measure resistance as a function of temperature of electroplated Bi independently of Au. The results show that the thermal conductivity of the Bi at 3 K is high enough to ensure the correct thermalization of X-ray photons when used as an absorber for TESs.
X-ray Topography Characterization of GaN Substrates Used for Power Electronic Devices
Explore the source record for details and available documents.
Board-level and Packaged Device Failure Analysis Using Electromagnetic Antenna/Injection Power Spectrum Analysis (EMAPSA/EMIPSA)
Explore the source record for details and available documents.
Evaluation of Portable Sensor and Spectroscopic Devices for Seafood Decomposition Determination
Not provided.
A comparison of efficiency-aware model-predictive control approaches for wave energy devices
In this study, we compare four different formulations of model predictive control that attempt to maximise electrical power generated by a wave energy converter (WEC). Control laws include (1) pure maximisation of mechanical power, (2) maximisation of mechanical power with a control penalty factor, (3) maximisation of electrical power using power conversion efficiency, and (4) maximisation of electrical power using the full electro-mechanical model of a system. For this study, a wave-to-wire model is developed for a floating spherical buoy connected to a permanent magnet synchronous generator. The performance of the controllers, including the mechanical and electrical power outputs, is compared in irregular wave conditions for the unconstrained and force-constrained scenarios. The results demonstrate that the controller designed to maximise mechanical power is not suitable for practical applications and may lead to negative electrical power output due to the non-ideal power take-off efficiency. Moreover, the replacement of the power take-off dynamics by the efficiency coefficient does not guarantee the maximum electrical power production.
Maybe less is more: Considering capacity factor, saturation, variability, and filtering effects of wave energy devices
Not Available
Enabling residential heating decarbonization through hydronic low-temperature thermal distribution using forced-air assistive devices
Space heating represents approximately one-tenth of the United States’ energy use and has a breadth of potential for emission reduction. An element of space heating, hydronic heat distribution methods, use water supply temperatures up to 82.2 °C (180 °F). However, this operating temperature can be incompatible with high-efficiency heat generation systems, which typically provide heating temperatures of up to 60 °C (140 °F). In this work, a low-cost retrofit solution is developed using experimentally validated computational tools by incorporating an airflow distributor that preferentially directs the airflow from a fan to enhance heat transfer over the finned-tube heat exchanger found in conventional baseboards. The same heat output of traditional baseboard heat distribution systems operating at higher water supply temperatures (71.1 – 82.2 °C) can also be achieved at lower temperatures (≤60 °C). Specifically, results indicate that the technology can produce more than a 46.7% improvement in the heat transfer output at temperatures as low as 60 °C (140 °F), effectively matching the same output range achieved by 71.1 – 82.2 °C (160–180 °F) water supply temperatures. An important benefit of this solution is that it utilizes the existing infrastructure as opposed to requiring the replacement of the entire distribution system. Additionally, this technology enables existing building infrastructure to be coupled with newer, high-efficiency heating systems such as condensing boilers, solar-thermal systems, and geothermal/air-to-water heat pumps that may produce lower water supply temperatures (60 °C). A geospatially resolved techno-economic and environmental analysis is completed and presented to further understand the equivalent carbon footprint of enabling higher efficiency heat generation systems with the improved efficiency heat distribution system disclosed. Using 2021 grid-average emission factors, an emission reduction of up to a 67.5% decrease (2658 kgCO 2 /yr) for a single-family home, depending on state and climate region, could be realized by replacing a traditional natural gas-fired boiler with an air-to-water heat pump coupled to the same high-temperature heat distribution system along with the low-cost retrofit solution. A complete CO 2 emission reduction of 6688 kgCO 2 /yr, depending on state and climate region, could be realized if all electricity is further renewably sourced. Thus, this study provides a possible pathway towards enabling the reduction of operational emissions in space heating.