Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cyber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Smart manufacturing maturity models and their applicability: a review

The purpose of this paper is to review existing smart manufacturing (SM) maturity models' dimensions and maturity levels to assess their applicability and drawbacks. There are many maturity models available but many of them have not been validated or do not provide a useful guide or tool for applications. This gap creates the need for a review of the existing maturity model's applicability. Nineteen peer-reviewed maturity models related to “Digital Transformation,” “Industry 4.0” or “Smart Manufacturing” were selected based on a systematic literature review and five consulting firm models were selected based on the author's industry knowledge. The chosen models were analyzed to determine 10 categories of dimensions. Then they are assessed on a 1–5 scale for how applicable they are in the 10 categories of dimensions. The five “consulting firm” models have a first-mover advantage, are more widely used in industry and are more applicable, but some require payment, and they lack published details and validation. The 19 “peer reviewed” models are not as widely used, lack awareness in the industry and are not as easy to apply because of no web tool for self-assessment, but they are improving. The categories defined to characterize the models and facilitate comparisons for users include “Information Technology (IT) and Cyber-Physical System (CPS) and Data,” “Strategy and Organization,” “Supply Chain and Logistics,” “Products and Services,” “Culture and Employees,” “Technology and Capabilities,” “Customer and Market,” “Cybersecurity and Risk,” “Leadership and Management” and “Governance and Compliance.” The analyzed maturity models were particularly weak in the areas of cybersecurity, leadership and governance. Researchers and practitioners can use this review with consideration of their specific needs to determine if a maturity model is applicable or if a new model needs to be developed. The review can also aid in the development of maturity models through the discussion of each of the dimension categories. Finally, compared to existing reviews of SM maturity models, this research determines comprehensive dimension categories and focuses on applicability and drawbacks.

42 ENGINEERING↗

Virtual Agents-Based Attack-Resilient Distributed Control for Islanded AC Microgrid

Due to its dependence on a communication network, distributed secondary control of microgrids is susceptible to denial-of-service (DoS) attacks in channel shutdown mode, which may negatively impact the network connectivity and thus deteriorate the coordination and power sharing among distributed generators (DGs). Honeypot is a common method for cyber deception by introducing fake targets. However, in the context of microgrid, the misleading information spread by honeypots will also impact the system performance. This paper proposes an attack-resilient distributed control for AC microgrids utilizing virtual agents (VAs) to counteract both DoS edge and node attacks. The VAs are designed to not impact the system’s steady state during normal operation but to share information among neighboring real agents and serve as dummy targets for DoS attacks. The control with VAs is implemented by a primal-dual gradient based distributed algorithm to efficiently obtain a practical solution for voltage/frequency regulation and power sharing. The simulation results on a 4-DG test system and a modified IEEE 34-bus system show that 1) VAs do not impact the normal functionality of the test system, and 2) deploying VAs can enhance the resilience of the microgrid control against DoS edge and node attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Statistical Analysis of Inter-Area Oscillations in the U.S. Eastern Interconnection: A 2017-2023 Perspective

Recent advancements and the accumulation of high-resolution, long-term phasor measurement unit (PMU) data have provided detailed insights into inter-area oscillations in power grids. This study conducts a comprehensive statistical analysis of inter-area oscillations within the United States Eastern Interconnection from 2017 to 2023. Utilizing data captured by the advanced wide-area Frequency Monitoring Network (FNET/GridEye), this investigation examines the occurrence patterns, dominant frequencies, damping ratios, and excitation mechanisms of these oscillations. Our analysis sheds light on the evolving statistical behaviors of inter-area oscillations, offering updated and critical information for grid operators and planners. The insights gained from this study can be instrumental in enhancing the operational resilience of the power network and guiding strategic developments in grid infrastructure to accommodate future challenges. Additionally, the study discusses emerging challenges associated with the modernization of the power grid, including increased renewable penetration, dynamic load variability, and cyber-physical vulnerabilities that complicate oscillation monitoring and control.

Inter-area oscillations↗

Identification of Critical Infrastructure via PageRank

Assessing critical infrastructure vulnerabilities is paramount to arranging efficient plans for their protection. Critical infrastructures are cyber-physical systems that can be represented as a network consisting of nodes and edges and highly interdependent in nature. Given the interdependent nature of critical infrastuctures, failure in one node may cause failure in many others resulting in a cascade of failures. In this paper, we propose a node criticality metric that uses Google’s PageRank algorithm to identify nodes that are likely to fail (are vulnerable), nodes whose failure may cascade to many other sites in the network (are important), and nodes that are both vulnerable and important (are critical). We then present a series of experiments to understand how protecting certain critical nodes can help mitigate massive cascading failures. Simulating failures in a real-world network with and without critical node protections demonstrates the importance of identifying critical nodes in an infrastructure network.

Kay, Bill↗

VWC-BERT: Scaling Vulnerability–Weakness–Exploit Mapping on Modern AI Accelerators

Defending cybersystems needs accurate mapping of software and hardware vulnerabilities to generalized descriptions of weaknesses, and weaknesses to exploits. These mappings enable cyber defenders to build plans for effective defense and assessment of potential risks to a cybersystem. With close to 170k vulnerabilities, manual mapping is not a feasible option. However, automated mapping is challenging due to limited training data, computational intractability, and limitations in computational natural language processing. Tools based on breakthroughs in Transformer-based language models have been demonstrated to classify vulnerabilities with high accuracy. We make three key contributions in this paper: (1) We present a new framework, \VWCBERT, that augments the Transformer-based hierarchical multi-class classification framework of Das et al. (\textsc{V2W-BERT}) with the ability to map weaknesses to exploits. (2) We implement \VWCBERT~ on modern AI accelerator platforms using two data parallel techniques for the pre-training phase and demonstrate nearly linear speedups across NVIDIA and Graphcore accelerator platforms. We observe nearly linear speedups for up to 16 V100 and 8 A100 GPUs, and about 3.4$\times$ speedup for A100 relative to V100 GPUs. We also observe excellent speedups on Graphcore, with $5.7\times$ speedup on 128 IPUs relative to 16 IPUs. Enabled by scaling, we also demonstrate higher accuracy using a larger language model, RoBERTa-Large. We show up to 87\% accuracy for strict and up to 98\% accuracy for relaxed classification. (3) We develop a novel parallel link manager for the link prediction phase and demonstrate up to 21$\times$ speedup with 16 V100 GPUs relative to one V100 GPU, and thus reducing the runtime from 2.5 hours to 10 minutes. We believe that generalizability and scalability of \VWCBERT~ will benefit both the theoretical development and practical deployment of novel cyberdefense solutions and vulnerability classification.

Das, Siddhartha Shankar↗

A Secure Learning Control Strategy via Dynamic Camouflaging for Unknown Dynamical Systems under Attacks

This paper presents a secure reinforcement learning (RL) based control method for unknown linear time-invariant cyber-physical systems (CPSs) that are subjected to compositional attacks such as eavesdropping and covert attack. We consider the attack scenario where the attacker learns about the dynamic model during the exploration phase of the learning conducted by the designer to learn a linear quadratic regulator (LQR), and thereafter, use such information to conduct a covert attack on the dynamic system, which we refer to as doubly learning-based control and attack (DLCA) framework. We propose a dynamic camouflaging based attack-resilient reinforcement learning (ARRL) algorithm which can learn the desired optimal controller for the dynamic system, and at the same time, can inject sufficient misinformation in the estimation of system dynamics by the attacker. The algorithm is accompanied by theoretical guarantees and extensive numerical experiments on a consensus multi-agent system and on a benchmark power grid model.

Mukherjee, Sayak↗

Resilient Operating Constraints for Power Distribution Systems under Setpoint Attacks

Integration and operation of distributed generation (DG) and energy storage (ES) in power distribution systems are enabled by communication networks and embedded sensor and control devices that increase the vulnerability of the systems to cyber-threats, broadening the attack surface and making adversary actions more unpredictable. This paper proposes a methodology that uses ellipsoidal approximations to quantify the potential damage caused by successful attacks that affect, directly or indirectly, the desired operation setpoints and may drive the power distribution operation to unsafe states by violating the limits of voltage or line flows. More specifically, a new methodology is introduced to find the optimal non-symmetric operating constraints that can be imposed to each DG and ES in order to guarantee that the power distribution system is resilient to any malicious setpoints. The proposed method takes as inputs the system topology, DG and ES capabilities, and load limits to solve a convex optimization problem formulated using linear matrix inequalities (LMIs) and the power flow equations. The proposed solution is agnostic to the attacker's action or load profile and it does not require any assumption about the location or means of the attack. The numerical results on a test distribution feeder with several DG and ES illustrate how the proposed resilient operating constraints guarantee the security of the power distribution system under setpoint attacks.

Giraldo, Jairo↗

Self-Security for Grid-Interactive Smart Inverters Using Steady-State Reference Model

Smart inverters exchange information with other devices through a shared communication link, making the inverters more prone to receive harmful commands from external parties. This erroneous data can be received due to an anomaly in the system, such as a device fault, unintentional utility operator action, or a cyber-attack. In this paper, a device-level self-security strategy is implemented using reference models for a grid-interactive inverter to examine the incoming power setpoints, detect the anomalies, and protect the system accordingly. The PQ setpoints received from the utility supervisory controller are autonomously examined using the inverter’s normal and stable operating regions before engaging the setpoints to the inverter’s local controller. Grid parameters are estimated in real-time during the examination process. The efficacy of the self-security algorithm is tested using a three-phase 3-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative grid emulator. The results verify that the proposed method can detect harmful PQ setpoints that can cause abnormal or unstable inverter operation.

Gursoy, Mehmetcan↗

Denial of Service Attack Detection via Differential Analysis of Generalized Entropy Progressions

Denial-of-Service (DoS) attacks are one the most common and consequential cyber attacks in computer networks. While existing research offers a plethora of detection methods, the issue of achieving scalability, a low false positive rate, and high detection accuracy remains open. In this work, we address this problem by developing a differential method based on generalized entropy progression. In this method, named as DoDGE, we continuously fit the line of best fit to the entropy progression of destination addresses and check if the derivative, that is, the slope of this line is less than the negative of the dynamically computed standard deviation of the derivatives. Furthermore, to distinguish from flash events, we leverage the symmetry that when a flash event occurs, the derivative of the entropy progression of source addresses is positive. With this design, we omit the usage of the thresholds and the results with five real-world network traffic datasets confirm that DoDGE outperforms threshold-based DoS attack detection by two orders of magnitude in terms of false positives on average. When compared to ten machine learning (ML) models, DoDGE achieves a balanced accuracy of 99%, while the average balanced accuracy for the ML models is 52%. Moreover, the results show that DoDGE successfully differentiates between a flash event and a DoS attack. Furthermore, since the main computation cost of DoDGE is the entropy computation, which is linear in the volume of the unit-time network flow, uses integer only operations, and works on a small fraction of the total flow, it is lightweight and scalable.

Cybersecurity, wireless communication↗

A Hybrid Anomaly Detection Approach for Obfuscated Malware

With the rapid evolution of malicious software, cyber threats have become increasingly sophisticated, employing advanced obfuscation techniques to evade traditional detection methods. This study presents a hybrid anomaly detection approach applied to obfuscated malware. Even though there is a large body of research in this field, existing malware detection techniques have some drawbacks, such as requiring large amounts of data, trustworthiness (imprecise results) of algorithms, and advanced obfuscation. To overcome these challenges, there is a need to employ solid and efficient techniques for malware detection. This paper proposes a hybrid approach, combining an autoencoder with traditional machine-learning methods to create an efficient malware detection framework. We used the malware memory dataset (MalMemAnalysis-2022) to evaluate this framework. The results indicate that our proposed approach can detect obfuscated malware when a deep autoencoder used for feature learning is combined with logistic regression, and it is extremely fast with an Accuracy, Detection Rate (DR), Matthew Correlation Coefficient(MCC), and Statistical Parity Difference

malware detection, Hybrid Anomly Detection, Obfusc↗

Vulnerability Detection Methodology for a Digital Signal Processor Micro-Controller at Edge Level Distributed Energy Resource Controller

Integration of renewable energy and energy storage based Distributed Energy Resource (DER) assets to the grid has seen an upsurge over the past few decades. Traditionally, energy would be generated at a thermal or nuclear power plant and then transmitted over long distance through the transmission grid and then supply to the customers at the distribution grid. Modern renewable energy based DER assets have brought energy production at the edge of distribution grid, which has made the grid vulnerable to cyber intrusion as the power flow controllers for such DER assets are now distributed across the grid from distribution level to transmission level. This paper discusses the vulnerability posed by such power flow controllers of DER assets and demonstrates a detection methodology for unauthorized access and manipulation of system configuration for Digital Signal Processor based Microcontrollers. Experimental results proving efficacy of the methodology have been shown in paper.

Bhowmik, Pankaj↗

Interstate-24 MOTION: Closing the Loop on Smart Mobility

We introduce the I-24 Mobility Technology Interstate Observation Network (MOTION), a transportation cyber-physical systems testbed under development in Tennessee. It consists of a six-mile freeway segment instrumented with 400 4K resolution cameras, processed by a real-time compute system to enable continuous performance monitoring of freeway traffic. The testbed is being developed to support next generation connected and autonomous vehicle technologies and advanced traffic management. When complete, the testbed will be the longest continuously observed freeway segment in the world. This article introduces the testbed, discusses the core design choices, and outlines the preliminary work conducted to support the design.

Gloudemans, Derek↗

An Active Detection Scheme for Sensor Spoofing in Grid-tied PV Systems

In this paper an active detection scheme for sensor spoofing (manipulated externally via a cyber attack) in grid-tied PV systems is discussed. The core of the proposed active detection scheme is to introduce a private (secret) watermarking signal into the control inputs of the DC-DC converter and DC-AC inverter stages to detect any malicious spoofing (manipulation) of voltage/current sensor measurements controlling both the DC-DC converter maximum power point tracking (MPPT) stage and the DC-AC inverter of the grid-tied PV system. Several types of possible spoofing mechanisms (attack models) are discussed. The proposed sensor spoofing attack detector system consists of injecting a small magnitude of digital watermarking signal (DWS) and conduct three statistical watermark tests on the reported sensor measurements to determine if a) the proposed system is healthy and operating as expected b) if sensor signals were spoofed (manipulated) externally or c) if a particular sensor is malfunctioning due to a faulty hardware. It is shown via extensive simulations that the proposed DWS approach is robust in detecting malicious external manipulation of sensors controlling the grid tied PV system. A testing platform is currently under development and the experimental results will be discussed in the conference presentation.

Ibrahim, Hasan↗

Strengthening Cybersecurity for Industrial Control Systems: Innovations in Protecting PLC-Based Infrastructure

In this paper, we propose two new approaches aimed at enhancing the security of industrial control systems (ICS) that utilize programmable logic controllers (PLCs) for the control of critical processes. The first approach involves the addition of a unique digital watermark to the PWM control that adjusts the motor speed to control the critical process. This enables efficient detection and identification of any unauthorized modifications to the sensor signals responsible for controlling the plant. The second approach focuses on monitoring the input current (i.e power) drawn by the PLC during the execution of critical process control tasks. Malicious intrusions to change the PLC parameters and/or unauthorized firmware updates can be rapidly detected. Both approaches demonstrate a substantial improvement in the security of ICS, effectively safeguarding against potential cyber-attacks. Experimental results from a laboratory scale water tank level controlled via PLC showcases rapid intrusion detection capabilities.

Huang, Peng-Hao↗

Secure Firmware Update and Device Authentication for Smart Inverters using Blockchain and Physically Uncloable Function (PUF)-Embedded Security Module

Cybersecurity of inverters has been significantly important as inverters become smarter in cyber-physical environments. However, firmware security of smart inverters against firmware attacks from various attack vectors has been less studied. Furthermore, this paper proposes a secure firmware update and device authentication method using a blockchain-based public key infrastructure (PKI) management system and a physically unclonable function (PUF)-embedded security module in a smart inverter. The proposed method is validated by experiments.

blockchain↗

A Graph-Net with Node Embeddings to Detect False Data Injection Attacks in Photovoltaic Systems

Distributed energy resources (DER) contribute to the operational stability of the larger power grid both at utility-scale as well as commercial and residential scales in aggregated forms. These DER in-turn are susceptible to increasing cyber threats. An adversary can plug into the same local network that a field photovoltaic (PV) system uses to interconnect its data loggers and inverters and manipulate certain measurements collected from the network or trick existing irradiance and inverter readings through false data injection attacks (FDIA). Control routines that rely on these measurements can propagate the false data, impacting critical decisions that result in a suboptimal operation or even cause intentional harm leading to inverter-tripping or unscheduled loads that need to be shed. To detect FDIA in PV systems, the paper introduces an attention-based graph neural network with node embeddings and applied it to a simple prototypical DC-coupled microgrid with PV, energy storage, and load. The algorithm shows a detection accuracy of up to 98.95%. The proposed FDIA detection technique will provide micro-grid operators with an effective method to safeguard their systems, guaranteeing the secure and reliable operation.

Parvez, Imtiaz [Utah Valley University]↗

Self-Secure Inverters Against Malicious Setpoints

The next generation of grid-interactive inverters brings a communication feature that allows data sharing from utility supervisory controllers and smart devices that are connected to the same network. This feature enhances the control capabilities of grid-interactive inverters to provide services beyond active power injection. However, communication networks entail more vulnerable surfaces to malicious attacks that may result in modifying active and reactive power setpoints and causing weak-grid conditions or abnormal inverter operation. In this paper, steady-state and the dynamic behavior of the inverter for the incoming setpoints are analyzed to detect false data injection attacks and provide device-level security. The steady-state behavior of the inverter in the operating region is determined from the grid parameters such as the grid voltage and the grid impedance. These estimations are accomplished by the proposed self-security technique through a low-frequency signal injection-based approach combined with the recursive least square method. Moreover, a reduced fourth-order inverter model is used as the dynamic reference model, and grid parameters as well as the incoming setpoints are implemented to the reference model to verify whether the dynamic behavior of the inverter is inside the permissible region of operation. The validity and performance of the proposed method are verified experimentally through Allen-Bradley Powerflex 755 three-phase inverter and a 12 kW NHR 9410 regenerative power grid emulator. The results show that the self-secure smart-inverter is able to accept or reject the incoming commands and thus is protected from malicious cyber-physical attacks.

Hossen, Tareq↗

Impact-Driven Sampling Strategies for Hybrid Attack Graphs

Cyber-Physical Systems (CPSs) have a large input space, with discrete and continuous elements across multiple layers. Hybrid Attack Graph (HAG) provide a flexible and efficient approach to generate attack sequences for a CPS. Analysis and testing of large-scale HAGs are prohibitively costly. We propose a dimension reduction via property-preserving multi-layer graph sampling algorithms. Existing property-preserving graph sampling approaches generate a representative subgraph of an original large-sized graph while preserving the key properties, such as node and edge distribution, clustering coefficients, and betweenness. On the other hand, we propose impact-driven sampling strategies to transform the input data to a lower-dimensional representation while retaining key properties of the data.

Subasi, Omer↗