Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Comparative Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Neural Ordinary Differential Equations for Nonlinear System Identification

Neural ordinary differential equations (NODE) have been recently proposed as a promising approach for nonlinear system identification tasks. In this work, we systematically compare their predictive performance with current state-of-the-art nonlinear and classical linear methods. In particular, we present a quantitative study comparing NODE's performance against neural state-space models and classical linear system identification methods and evaluate their inference speed and prediction performance on open-loop errors across eight different dynamical systems. The experiments show that NODEs can consistently improve the prediction accuracy by order of magnitude compared to benchmark methods. Besides improved accuracy, we also observed that NODEs are less sensitive to hyperparameters compared to neural state-space models by paying the cost of increased computation at the inference time.

machine leaning, system identification, physics in↗

Optical sample-position sensing for electrostatic levitation

A comparative study is conducted for optical position-sensing techniques applicable to micro-G conditions sample-levitation systems. CCD sensors are compared with one- and two-dimensional position detectors used in electrostatic particle levitation. In principle, the CCD camera method can be improved from current resolution levels of 200 microns through the incorporation of a higher-pixel device and more complex digital signal processor interface. Nevertheless, the one-dimensional position detectors exhibited superior, better-than-one-micron resolution.

Sridharan, G.↗

Comparison of Test Stand and Helicopter Oil Cooler Bearing Condition Indicators

The focus of this paper was to compare the performance of HUMS condition indicators (CI) when detecting a bearing fault in a test stand or on a helicopter. This study compared data from two sources: first, CI data collected from accelerometers installed on two UH-60 Black Hawk helicopters when oil cooler bearing faults occurred, along with data from helicopters with no bearing faults; and second, CI data that was collected from ten cooler bearings, healthy and faulted, that were removed from fielded helicopters and installed in a test stand. A method using Receiver Operating Characteristic (ROC) curves to compare CI performance was demonstrated. Results indicated the bearing energy CI responded differently for the helicopter and the test stand. Future research is required if test stand data is to be used validate condition indicator performance on a helicopter.

Dempsey, Paula J.↗

SU-E-T-503: Intensity Modulated Proton Therapy (IMPT) Versus Intensity Modulated X-Ray Therapy (IMRT) for Patient with Hepatocellular Carcinoma: A Dosimetric Comparison

Purpose This study compares the dosimetric parameters in treatment of unresectable hepatocellular carcinoma between intensity modulated proton therapy (IMPT) and intensity modulated x-ray radiation therapy (IMRT). Methods and Materials: We studied four patients treated at our institution. All patients were simulated supine with 4D-CT using a GE light speed simulator with a maximum slice thickness of 3mm. The average CT and an internal target volume to account for respiration motion were used for planning. Both IMRT and IMPT plans were created using Elekta’s CMSXiO treatment planning system (TPS). The prescription dose was 58.05 CGE in 15 fractions. The IMRT plans had five beams with combination of co-planar and non-co-planar. The IMPT plans had 2 to 3 beams. Dose comparison was performed based on the averaged results of the four patients. Results The mean dose and V95% to PTV were 58.24CGE, 98.57% for IMPT, versus 57.34CGE and 96.68% for IMRT, respectively. The V10, V20, V30 and mean dose of the normal liver for IMPT were 23.10%, 18.61%, 13.75% and 9.78 CGE; and 47.19%, 37.55%, 22.73% and 17.12CGE for IMRT. The spinal cord didn’t receive any dose in IMPT technique, but received a maximum of 18.77CGE for IMRT. The IMPT gave lower maximum dose to the stomach as compared to IMRT (19.26 vs 26.35CGE). V14 for left and right kidney was 0% and 2.32% for IMPT and 3.89% and 29.54% for IMRT. The mean dose, V35, V40 and V45 for small bowl were similar in both techniques, 0.74CGE, 6.27cc, 4.85cc and 3.53 cc for IMPT, 3.47CGE, 9.73cc, 7.61cc 5.35cc for IMRT. Conclusion Based on this study, IMPT plans gave less dose to the critical structures such as normal liver, kidney, stomach and spinal cord as compared to IMRT plans, potentially leading to less toxicity and providing better quality of life for patients.

60 APPLIED LIFE SCIENCES↗

Nature of Electronically Excited States of Furocoumarins

A comprehensive study of spectral-luminescent and photophysical properties of coumarin sensitizers is performed using the methods of quantum chemistry, electron spectroscopy, and fluorescence. A comparative study of photophysical processes occurring in 8-methoxypsoralen (8-MOP) and 4,9-dimethoxy-7-methylfuro [3,2-g][1] benzofuran-5-1 (khellin) is performed using the quantum-chemical software package based on the semi-empirical method of intermediate neglect of differential overlap with original spectroscopic parameterization. The dependences of the fluorescent properties and reactivity of the compounds on the geometry and composition of the solvation shell of molecules are established. It is shown that incorporation of additional methoxy groups in the structure of molecules has the strongest effect on the spectral-luminescent characteristics of khellin compared with 8-MOP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ureteral pseudodiverticulosis and urothelial cell carcinoma: rethinking the association

Purpose: To compare frequency of new and recurrent urothelial cell carcinoma (UCC) among patients with and without pseudodiverticulosis on imaging. Methods: This retrospective case–control study compared all 113 sequential patients with ureteral pseudodiverticulosis on radiographic urography between 1/1/2002 and 12/31/2012. Six patients were lost to follow-up. 107 patients without pseudodiverticulosis were matched by imaging modality, clinical indication, and tumor grade. Known UCC and primary outcome of new or recurrent UCC were determined through pathology on cystoscopy or clinical follow-up. Results: Nearly half of patients with pseudodiverticulosis had known UCC at the time of imaging (49/107, 46%). Mean cystoscopy follow-up was 7.0 and 4.6 years for pseudodiverticulosis cases with and without known UCC, respectively, and 7.5 and 7.3 years for controls, respectively. Mean clinic follow-up was 7.5 and 6.0 years for pseudodiverticulosis cases with and without known UCC, respectively, and 6.4 and 7.6 years for controls, respectively. Among patients with known UCC at the time of imaging, similar rates of recurrent UCC were demonstrated on follow-up among patients with pseudodiverticulosis (6/49, 12%) and without (7/49, 14%). Among patients with no known history of UCC at the time of imaging, no patients with pseudodiverticulosis developed UCC on follow-up and 5% (3/58) of patients without pseudodiverticulosis developed UCC. Conclusion: Although half of patients with ureteral pseudodiverticulosis have a known diagnosis of UCC, the presence of pseudodiverticulosis did not signify an increased likelihood of developing new or recurrent UCC over the follow-up period.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relationships Between Solidification Parameters in A319 Aluminum Alloy

The design of high-performance materials depends on a comprehensive understanding of the alloy-specific relationships between solidification and properties. However, the inconsistent use of a particular solidification parameter for presenting materials characterization in the literature impedes inter-study comparability and the interpretation of findings. Therefore, there is a need for accurate expressions relating the solidification parameters for each alloy. In this study, A319 aluminum alloy castings were produced in a permanent mold with various preheating temperatures in order to control metal cooling. Analysis of the cooling curve for each casting enabled the identification of its liquidus, Al-Si eutectic, and solidus temperatures and times. These values led to the calculation of the primary solidification rate, total solidification rate, primary solidification time, and local solidification time for each casting, which were related to each other as well as to the average casting SDAS and material hardness. Expressions for each of their correlations have been presented with high coefficients of determination, which will aid in microstructural prediction and casting design.

36 MATERIALS SCIENCE↗

SU-E-T-110: Development of An Independent, Monte Carlo, Dose Calculation, Quality Assurance Tool for Clinical Trials

Purpose: To develop a comprehensive end-to-end test for Varian's TrueBeam linear accelerator for head and neck IMRT using a custom phantom designed to utilize multiple dosimetry devices. Purpose: To commission a multiple-source Monte Carlo model of Elekta linear accelerator beams of nominal energies 6MV and 10MV. Methods: A three source, Monte Carlo model of Elekta 6 and 10MV therapeutic x-ray beams was developed. Energy spectra of two photon sources corresponding to primary photons created in the target and scattered photons originating in the linear accelerator head were determined by an optimization process that fit the relative fluence of 0.25 MeV energy bins to the product of Fatigue-Life and Fermi functions to match calculated percent depth dose (PDD) data with that measured in a water tank for a 10x10cm2 field. Off-axis effects were modeled by a 3rd degree polynomial used to describe the off-axis half-value layer as a function of off-axis angle and fitting the off-axis fluence to a piecewise linear function to match calculated dose profiles with measured dose profiles for a 40×40cm2 field. The model was validated by comparing calculated PDDs and dose profiles for field sizes ranging from 3×3cm2 to 30×30cm2 to those obtained from measurements. A benchmarking study compared calculated data to measurements for IMRT plans delivered to anthropomorphic phantoms. Results: Along the central axis of the beam 99.6% and 99.7% of all data passed the 2%/2mm gamma criterion for 6 and 10MV models, respectively. Dose profiles at depths of dmax, through 25cm agreed with measured data for 99.4% and 99.6% of data tested for 6 and 10MV models, respectively. A comparison of calculated dose to film measurement in a head and neck phantom showed an average of 85.3% and 90.5% of pixels passing a 3%/2mm gamma criterion for 6 and 10MV models respectively. Conclusion: A Monte Carlo multiple-source model for Elekta 6 and 10MV therapeutic x-ray beams has been developed as a quality assurance tool for clinical trials.

60 APPLIED LIFE SCIENCES↗

Remote sensing of the biosphere

The current state of understanding of the biosphere is reviewed, the major scientific issues to be addressed are discussed, and techniques, existing and in need of development, for the science are evaluated. It is primarily concerned with developing the scientific capabilities of remote sensing for advancing the subject. The global nature of the scientific objectives requires the use of space-based techniques. The capability to look at the Earth as a whole was developed only recently. The space program has provided the technology to study the entire Earth from artificial satellites, and thus is a primary force in approaches to planetary biology. Space technology has also permitted comparative studies of planetary atmospheres and surfaces. These studies coupled with the growing awareness of the effects that life has on the entire Earth, are opening new lines of inquiry in science.

Source record↗

Circulating levels of perfluoroalkyl substances are associated with dietary patterns – A cross sectional study in elderly Swedish men and women

Background: In our daily life, we are exposed to perfluoroalkyl substances (PFAS) with possible health implications. The main exposure route for these substances is diet but comparative studies on how dietary habits influence exposure are lacking. Objectives: To examine the relations between blood levels of PFAS and adherence to three predefined dietary patterns (a WHO recommended diet, a Mediterranean-like diet, and a Low-Carbohydrate High-Protein (LCHP) diet) in an elderly Swedish population. Methods: Dietary data from 7-day food records and serum concentrations of PFAS were obtained from a 70-year-old Swedish population (n=844), the Prospective Investigation of the Vasculature in Uppsala Seniors (PIVUS) study. The Healthy Diet Indicator score (based on WHO recommendations), the Mediterranean Diet Score and LCHP score were used to assess adherence. Multivariate linear regression was used to assess the associations between eight major PFAS and adherence to each dietary pattern. Results: The WHO recommended diet was positively associated with perfluorohexane sulfonic acid (PFHxS). The LCHP diet was positively related to four out of eight PFAS; namely, perfluorooctane sulfonic acid (PFOS), perfluorononanoic acid (PFNA), perfluorodecanoic acid (PFDA) and perfluoroundecanoic acid (PFUnDA). The Mediterranean-like diet was positively associated with most PFAS; namely perfluorooctanoic acid (PFOA), perfluorooctane sulfonamide (PFOSA), PFHxS, PFNA, PFDA, and PFUnDA. Conclusions: All dietary patterns were positively associated with blood levels of PFAS. The highest body burden of PFAS was found in individuals with high adherence to a Mediterranean-like diet, whilst individuals who more closely followed the officially recommended diet displayed a lower body burden of these compounds. - Highlights: • Perfluoroalkyl substances (PFAS) quantified in blood of 70-y-old Swedish subjects. • Adherence to predefined dietary patterns was associated with circulating PFAS. • A Mediterranean-like diet was positively associated with most circulating PFAS. • A low-carbohydrate high-protein diet was positively related to some PFAS in blood. • A WHO-recommended diet was only related to higher circulating levels of PFHxS.

54 ENVIRONMENTAL SCIENCES↗

Comparison of Numerical Methods for Modeling the Wave Field Effects Generated by Individual Wave Energy Converters and Multiple Converter Wave Farms

This numerical study compares the wave field generated by the spectral wave action balance code, SNL-SWAN, to the linear-wave boundary-element method (BEM) code, WAMIT. The objective of this study is to assess the performance of SNL-SWAN for modeling wave field effects produced by individual wave energy converters (WECs) and wave farms comprising multiple WECs by comparing results from SNL-SWAN with those produced by the BEM code WAMIT. BEM codes better model the physics of wave-body interactions and thus simulate a more accurate near-field wave field than spectral codes. In SNL-SWAN, the wave field’s energy extraction is modeled parametrically based on the WEC’s power curve. The comparison between SNL-SWAN and WAMIT is made over a range of incident wave conditions, including short-, medium-, and long-wavelength waves with various amounts of directional spreading, and for three WEC archetypes: a point absorber (PA), a pitching flap (PF) terminator, and a hinged raft (HR) attenuator. Individual WECs and wave farms of five WECs in various configuration were studied with qualitative comparisons made of wave height and spectra at specific locations, and quantitative comparisons of the wave fields over circular arcs around the WECs as a function of radial distance. Results from this numerical study demonstrate that in the near-field, the difference between SNL-SWAN and WAMIT is relatively large (between 20% and 50%), but in the far-field from the array the differences are minimal (between 1% and 5%). The resultant wave field generated by the two different numerical approaches is highly dependent on parameters such as: directional wave spreading, wave reflection or scattering, and the WEC’s power curve.

16 TIDAL AND WAVE POWER↗

Spectroscopic Study of the Charge Density Wave Order in 2H-TaS{sub 2}.

We conduct Angle Resolved Photoemission Spectroscopy (ARPES) investigation on 2H-TaS2, a prototypical incommensurate Charge Density Wave (CDW) material. A comparative study of the low-energy electronic structures of 2H-TaS2 and two other related compounds, 2H-TaSe2 and 2H-NbSe2, identifies several generic features of their CDW orders. Firstly, Fermi surface (FS) nesting alone doesn't seem to give rise to the CDW instability in these compounds. Secondly, partial gapping of the underlying FS surface in the CDW state is common to each of these materials. Finally, the CDW energy gap, unlike the energy gap in a superconductor, is not symmetric with respect to the chemical potential.

Angle Resolved Photoemission Spectroscopy↗

Open-Shell Donor–Acceptor Conjugated Polymers with High Electrical Conductivity

Conductive polymers largely derive their electronic functionality from chemical doping, processes by which redox and charge-transfer reactions form mobile carriers. While decades of research have demonstrated fundamentally new technologies that merge the unique functionality of these materials with the chemical versatility of macromolecules, doping and the resultant material properties are not ideal for many applications. Here, it is demonstrated that open-shell conjugated polymers comprised of alternating cyclopentadithiophene and thiadiazoloquinoxaline units can achieve high electrical conductivities in their native “undoped” form. Spectroscopic, electrochemical, electron paramagnetic resonance, and magnetic susceptibility measurements demonstrate that this donor–acceptor architecture promotes very narrow bandgaps, strong electronic correlations, high-spin ground states, and long-range π-delocalization. A comparative study of structural variants and processing methodologies demonstrates that the conductivity can be tuned up to 8.18 S cm -1 . This exceeds other neutral narrow bandgap conjugated polymers, many doped polymers, radical conductors, and is comparable to commercial grades of poly(styrene-sulfonate)-doped poly(3,4-ethylenedioxythiophene). X-ray and morphological studies trace the high conductivity to rigid backbone conformations emanating from strong π-interactions and long-range ordered structures formed through self-organization that lead to a network of delocalized open-shell sites in electronic communication. The results offer a new platform for the transport of charge in molecular systems.

36 MATERIALS SCIENCE↗

Ubiquitous strong electron–phonon coupling at the interface of FeSe/SrTiO 3

The observation of replica bands in single-unit-cell FeSe on SrTiO 3 (STO)(001) by angle-resolved photoemission spectroscopy (ARPES) has led to the conjecture that the coupling between FeSe electrons and the STO phonons are responsible for the enhancement of T c over other FeSe-based superconductors. However the recent observation of a similar superconducting gap in single-unit-cell FeSe/STO(110) raised the question of whether a similar mechanism applies. Here we report the ARPES study of the electronic structure of FeSe/STO(110). Similar to the results in FeSe/STO(001), clear replica bands are observed. We also present a comparative study of STO(001) and STO(110) bare surfaces, and observe similar replica bands separated by approximately the same energy, indicating this coupling is a generic feature of the STO surfaces and interfaces. Lastly, our findings suggest that the large superconducting gaps observed in FeSe films grown on different STO surface terminations are likely enhanced by a common mechanism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Uncertainty-aware mixed-variable machine learning for materials design

Abstract Data-driven design shows the promise of accelerating materials discovery but is challenging due to the prohibitive cost of searching the vast design space of chemistry, structure, and synthesis methods. Bayesian optimization (BO) employs uncertainty-aware machine learning models to select promising designs to evaluate, hence reducing the cost. However, BO with mixed numerical and categorical variables, which is of particular interest in materials design, has not been well studied. In this work, we survey frequentist and Bayesian approaches to uncertainty quantification of machine learning with mixed variables. We then conduct a systematic comparative study of their performances in BO using a popular representative model from each group, the random forest-based Lolo model (frequentist) and the latent variable Gaussian process model (Bayesian). We examine the efficacy of the two models in the optimization of mathematical functions, as well as properties of structural and functional materials, where we observe performance differences as related to problem dimensionality and complexity. By investigating the machine learning models’ predictive and uncertainty estimation capabilities, we provide interpretations of the observed performance differences. Our results provide practical guidance on choosing between frequentist and Bayesian uncertainty-aware machine learning models for mixed-variable BO in materials design.

36 MATERIALS SCIENCE↗

A comparative analysis of electronic and molecular quantum dot cellular automata

This paper presents a comparative analysis of electronic quantum-dot cellular automata (EQCA) and Magnetic quantum dot Cellular Automata (MQCA). QCA is a computing paradigm that encodes and processes information by the position of individual electrons. To enhance the high dense and ultra-low power devices, various researches have been actively carried out to find an alternative way to continue and follow Moore’s law, so called “beyond CMOS technology”. There have been several proposals for physically implementing QCA, EQCA and MQCA are the two important QCAs reported so far. This paper provides a comparative study on these two QCAs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Source size of x rays from self-modulated laser wakefield accelerators

A comparative study of x-ray sources generated with different mechanisms from self-modulated laser wakefield acceleration (SM-LWFA) electrons was performed to compare the source size or spatial resolution for use in high energy density science applications. We examine the source size of betatron, inverse Compton scattering, and bremsstrahlung radiation with a Fresnel diffraction based formalism and a modified x-ray ray tracing model. We observe the dependence of source size on the radiation generation process, laser parameters, and compare to what is possible in other regimes of LWFA, as well as current methods. This information is significant as we begin to explore the use of light sources driven by SM-LWFA for use as a diagnostic at large-scale laser facilities where blowout regime LWFA is not possible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Range vegetation type mapping and above-ground green biomass estimations using multispectral imagery

The author has identified the following significant results. Range vegetation types have been successfully mapped on a portion of the 68,000 acre study site located west of Baggs, Wyoming, using ERTS-1 imagery. These types have been ascertained from field transects over a five year period. Comparable studies will be made with EREP imagery. Above-ground biomass estimation studies are being conducted utilizing double sampling techniques on two similar study sites. Information obtained will be correlated with percent relative reflectance measurements obtained on the ground which will be related to image brightness levels. This will provide an estimate of above-ground green biomass with multispectral imagery.

Houston, R. S.↗