Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

General Line Ampacity State Solver

INL’s General Line Ampacity State Solver (GLASS) is a high performance software platform that enables advanced grid system operations and planning efforts to be computed in real time. It enables the combination of advanced sensors and sensor networks, communication and data transfer channels, secure and reliable data management, and real-time processing through a flexible system architecture, with the ability to support and integrate with any utility enterprise system. GLASS is designed to help resolve the problems associated with thermally limited transmission and distribution networks, namely bare overhead power transmission lines. GLASS enables the methodology of Concurrent Cooling (Dynamic Line Rating) by reducing the need of using a cost-prohibited number of weather stations (reduce the number of weather stations per mile of overhead power line) to achieve the resolution necessary for individual electric transmission line span capacity calculations. GLASS achieves this by coupling real-time grid operations data and infrastructure architecture information with real-time field deployed weather station measurements and pre-computed Computational Fluid Dynamics (CFD)-based wind modeling interpolation parameters (look-up tables). GLASS uses mathematical models based on the IEEE 738 standard and builds off of the provided iterative solution using modern software paradigms and programming styles to provide a more robust and modular software system. GLASS also interfaces in real-time with utility companies using known transmission line spans and structures. GLASS provides real-time ampacity calculations based on recent weather station data as well as transmission line specifications. GLASS also allows the user to interact graphically with internal databases, which include information such as transmission line conductor types and thermal rating limits, weather station names and locations, specific transmission line span and structure locations, as well as recent ampacity calculations.

Gentle, Jake↗

Midwest Nuclear-based Net-Zero Carbon Steelmaking Demonstration

Globally, the iron and steel industry accounts for around a quarter of GHG emissions from the manufacturing sector , which is about 7% of the 33 gigatonnes (Gt) of global CO 2 emissions . Thus, globally, the steel industry is a 2-3 Gt CO 2 per year emissions challenge. The steel industry is important to the U.S. economy with output equal to $0.5 trillion and domestic production capacity is critical to national defense, infrastructure, energy production, and transportation. President Biden’s executive order on climate identifies actions and policies to put the Nation on a path to achieve net-zero carbon emissions, economy-wide, by no later than 2050. To achieve this, deep carbon reductions in the power, transportation, buildings and capital-intensive industrial manufacturing segments such as steel, cement and chemicals need to be addressed. In its recent “Accelerating Decarbonization of the U.S. Energy System” report , the National Academy of Sciences (NAS) stated that, “while technology exists to decarbonize all parts of the energy system, some sectors remain at precommercial or first-of-a-kind demonstration stages and require significant improvement in cost and performance to become commercially viable.” The NAS goes on to state that these hard to decarbonize sectors include “aviation, shipping, and industrial subsectors such as steel, cement, and chemicals manufacturing .” The Administration has proposed a timeline to decarbonize energy, transportation and then industry and manufacturing. From a life-cycle approach, decarbonizing steel and other large industrial inputs are necessary to decarbonize transformations in energy and transportation. DOE’s TRI-Lab Consortium’s Integrated Energy Systems (IES) program is a collaboration amongst DOE’s three applied energy laboratories: the National Energy Technology Laboratory; National Renewable Energy Laboratory and Idaho National Laboratory. The IES approach looks at more tightly integrating low-carbon nuclear energy, renewable electricity, energy storage, load/demand balancing, and biomass (including plastics and other wastes) with one or more industrial processes that utilize heat and/or power from these clean and waste energy sources to produce a low-carbon commodity-scale product.

08 HYDROGEN↗

Solar heating and hot water system installed at Cherry Hill, New Jersey

The solar heating and hot water system installed in existing buildings at the Cherry Hill Inn in Cherry Hill, New Jersey is described in detail. The system is expected to furnish 31.5% of the overall heating load and 29.8% of the hot water load. The collectors are liquid evacuated tube type. The storage system is an above ground insulated steel water tank with a capacity of 7,500 gallons.

Source record↗

Cost-Benefit Analysis of High-Strength Materials for Safety-Related Nuclear Reinforced Concrete Shear Walls

A numerical parametric investigation was conducted to determine the economic benefits of utilizing high-strength concrete and high-strength steel reinforcing bar (rebar) in reinforced concrete (RC) shear walls for nuclear power plant structures. Thick RC shear walls with low height-to-length aspect ratios (i.e., aspect ratios, h{sub w}/l{sub w}≤2.0, where h{sub w} is the wall height and l{sub w} is the wall length) are the most common lateral load resisting members in non-containment, safety-related nuclear structures. Typically, the walls are reinforced with multiple layers of overlapping, large-diameter vertical and horizontal rebar on each face. These heavily-reinforced walls provide large lateral stiffness and strength to prevent significant deformations and/or cracking that could compromise the integrity of the nuclear facility. However, this design adversely affects constructability as the rebar cages become highly congested. The time, labor, and materials required for this construction lead to high overall project costs. There has been a recent research thrust in the U.S. to allow high-strength rebar in non-nuclear building structures. While some of this research (e.g., steel properties, bond, anchorage) is applicable to RC structures in general, there are important differences specific to nuclear structures, such as much thicker walls (often controlled by radiation and thermal cycling), larger reinforcement ratios, and increased susceptibility to shear-controlled behavior (due to low aspect ratios). An important limiting factor for non-nuclear structures in seismic regions is the reduced deformation capacity of high-strength rebar as compared with normal-strength rebar used in current practice. Differences in seismic design philosophy lessen this limitation for nuclear structures (i.e., nuclear structures are designed more conservatively and allowed to undergo significantly smaller nonlinear displacements), making high-strength rebar a promising alternative to reinforcement currently permissible in the ACI 349-13 code requirements, which govern the design of nuclear safety-related concrete structures. To improve constructability and economy, this study investigates the benefits of using high-strength rebar [i.e., ASTM A615 Grade 550 (U.S. Grade 80); ASTM A1035 Grades 690 and 830 (U.S. Grades 100 and 120), where the grade indicates the specified yield strength of the steel in MPa (ksi)] together with high-strength concrete [compression strengths up to 138 MPa (20.0 ksi)] in RC nuclear shear walls. These strength ranges represent steel and concrete materials that are commercially available in the U.S. High-strength rebar can significantly reduce the required steel areas, thereby reducing material/fabrication costs, reducing rebar congestion (fewer/smaller bars and bar layers), and facilitating concrete consolidation and placement. Previous research on the use of high-strength rebar and/or high-strength concrete in nuclear RC structures does not exist in North America. A recent study assessed the potential of high-strength steel to reduce the rebar volume in non-nuclear building construction. In Japan, researchers investigated the use of high-strength materials in safety-related nuclear RC structures, but did not explore the economic benefits of these materials. To address this knowledge gap, the current paper describes a numerical parametric investigation on the potential cost savings of nuclear shear walls with high-strength rebar and/or concrete through comparisons against state-of-practice walls with normal-strength materials. Overall, the results demonstrate that significant economic benefits can be realized by implementing high-strength rebar and concrete in these structures. (authors)

36 MATERIALS SCIENCE↗

Experimentally-determined characteristics of radiant systems for office buildings

Radiant heating and cooling systems have significant energy-saving potential and are gaining popularity in commercial buildings. The main aim of the experimental study reported here was to characterize the behavior of radiant cooling systems in a typical office environment, including the effect of ceiling fans on stratification, the variation in comfort conditions from perimeter to core, control on operative temperature vs. air temperature and the effect of carpet on cooling capacity. The goal was to limit both the first cost and the perceived risk associated with such systems. Two types of radiant systems, the radiant ceiling panel (RCP) system and the radiant slab (RS) system, were investigated. The experiments were carried out in one of the test cells that constitute the FLEXLAB test facility at the Lawrence Berkeley National Laboratory in March and April 2016. In total, ten test cases (five for RCP and five for RS) were performed, covering a range of operational conditions. In cooling mode, the air temperature stratification is relatively small in the RCP, with a maximum value of 1.6 K. The observed stratification effect was significantly greater in the RS, twice as much as that in the RCP. The maximum increase in dry bulb temperature in the perimeter zone due to solar radiation was 1.2 K for RCP and 0.9 K for RS – too small to have a significant impact on thermal comfort. The use of ceiling fans was able to reduce any excess stratification and provide better indoor comfort, if required. The use of thin carpet requires a 1 K lower supply chilled water temperature to compensate for the added thermal resistance, somewhat reducing the opportunities for water-side free cooling and increasing the risk of condensation. In both systems, the difference between the room operative temperature and the room air temperature is small when the cooling loads are met by the radiant systems. In conclusion, this makes it possible to use the air temperature to control the radiant systems in lieu of the operative temperature, reducing both first cost and maintenance costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficiency to reduce residential electricity and natural gas use under climate change

also lead to the increased adoption and use of cooling technologies in buildings. We assess residential electricity and natural gas demand in Los Angeles, California under multiple climate change projections and investigate the potential for energy effficiency to offset increased demand. We calibrate residential energy use against metered data, accounting for differences in building materials and appliances. Under temperature increases, we find that without policy intervention, residential electricity demand could increase by as much as 41–87% between 2020 and 2060. However, aggressive policies aimed at upgrading heating/cooling systems and appliances could result in electricity use increases as low as 28%, potentially avoiding the installation of new generation capacity. We therefore recommend aggressive energy effficiency, in combination with low-carbon generation sources, to offset projected increases in residential energy demand.

54 ENVIRONMENTAL SCIENCES↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources

Integrating a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problems requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (control-lable DERs), including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperforms other benchmark controllers regarding computation time without compromising operational performance.

DER↗

Wastewater Treatment at the Fernald Preserve-Past, Present, and Future - 19555

Industrial wastewater treatment at the Fernald Preserve, Ohio, Site has been ongoing since a uranium metals refinery was constructed there at the beginning of the Cold War in 1951. Initially, the primary purpose of treatment was to recover uranium for reuse. Later, when cleanup of the site was progressing in the 1990's, wastewater treatment efforts greatly expanded. Large treatment facilities were constructed to handle contaminated surface water, groundwater, remediation wastewater, and leachate from the on-site disposal facility. These new facilities were designed to reduce uranium concentration to meet the US Environmental Protection Agency (EPA) drinking water standard and not generate large quantities of contaminated waste. Anion-exchange resin was chosen as the treatment media. The centerpiece of these facilities was the Advanced Wastewater Treatment facility, which had a treatment capacity of 10,978 liters per minute (lpm) (2900 gallons per minute [gpm]). Forecasts estimated that with the exception of groundwater the site's remediation would be completed in 2006. In 2003, the US Department of Energy (DOE) Office of Environmental Management began negotiations with the EPA and Ohio Environmental Protection Agency to reduce wastewater treatment capacity at the Fernald Environmental Management Project. These negotiations resulted in the site's treatment capacity being reduced to 6814 lpm (1800 gpm) via the Converted Advanced Wastewater Treatment facility (CAWWT). By 2010, the uranium concentration in the groundwater being pumped had been reduced to the degree that only intermittent treatment for uranium removal was needed. As a result, the CAWWT was considerably oversized. Increased maintenance on the aging CAWWT equipment led the DOE Office of Legacy Management (LM) to commission an assessment of the facility, which was completed in early 2015. The condition assessment identified numerous components at or near the end of their design life. Based on the assessment's findings and the fact that the current facility's treatment capacity was substantially greater than needed, LM began looking at options for an appropriately sized treatment system to handle the site's needs until the groundwater remediation was completed (currently projected for 2039). Options were evaluated in the spring of 2015, and LM presented the recommended changes to regulators and stakeholders. Approvals for a new, smaller system with a 189 lpm (50 gpm) capacity were obtained through a series of meetings in the summer of 2015. After more detailed planning in the fall of 2015, LM initiated the project in 2016. The project comprises the following four phases: (1) Removal and disposal of used media, piping, and tanks to make room for the new system in the existing building (completed in January 2017); (2) design of the new system (completed in April 2017); (3) construction, installation, and startup of the new system (completed in May 2018); and (4) backwash basin refurbishment (yet to be completed). In the late 2030's, when groundwater remediation is projected to be completed at the site, it is anticipated that the only remaining wastewater treatment need will be for small quantities of leachate from the on-site disposal facility. Results of leachate treatment testing in 2003 indicate it may be feasible to utilize a small passive treatment system for this leachate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measured Performance of a Varied Airflow Small-Diameter Duct System

In this study, researchers with the U.S. Department of Energy's Building America team IBACOS built on research previously done in two new-construction unoccupied test houses-one in Pittsburgh, Pennsylvania (Poerschke and Stecher 2014) and one in Fresno, California (Stecher and Poerschke 2013). Specific traditional central air distribution systems were installed in each of these low-load homes. For this study, the cold-climate new-construction unoccupied test house in Pittsburgh, Pennsylvania, was modified to test the performance of a heating, ventilating, and air-conditioning (HVAC) system with varied airflow and small-diameter ducts. The main goal of the small-diameter duct system is to simplify the task of bringing ductwork inside conditioned space, particularly on the single-story slab-on-grade type of home that is prevalent in the South and Southeast. Guidance is provided here to homebuilders and HVAC contractors on cost and performance tradeoffs between the conventional duct system and the small-diameter duct system. Comparisons were made between variable-capacity heat pump operation modes with three constant airflow rates to determine the ideal tradeoff between maximizing thermal comfort and minimizing fan energy consumption. ASHRAE Standard 55 (ASHRAE 2010a) was used to set limit metrics for temporal temperature variation; Air Conditioning Contractors of America (ACCA) Manual RS (Rutkowski 1997) was used to set a limit on spatial temperature uniformity (room-to-thermostat uniformity). The small diameter duct system was able to meet the temporal temperature variation limits much better than the spatial temperature uniformity limits. TO4 2.1.2: High Velocity Space Cond. Systems

ACCA Manual RS↗

Sustainable aviation fuels from biomass and biowaste via bio- and chemo-catalytic conversion: Catalysis, process challenges, and opportunities

Sustainable aviation fuel (SAF) production from biomass and biowaste streams is an attractive option for decarbonizing the aviation sector, one of the most-difficult-to-electrify transportation sectors. Despite ongoing commercialization efforts using ASTM-certified pathways (e.g., lipid conversion, Fischer-Tropsch synthesis), production capacities are still inadequate due to limited feedstock supply and high production costs. New conversion technologies that utilize lignocellulosic feedstocks are needed to meet these challenges and satisfy the rapidly growing market. Combining bio- and chemo-catalytic approaches can leverage advantages from both methods, i.e., high product selectivity via biological conversion, and the capability to build C-C chains more efficiently via chemical catalysis. Herein, conversion routes, catalysis, and processes for such pathways are discussed, while key challenges and meaningful R&D opportunities are identified to guide future research activities in the space. Bio and chemo-catalytic conversion primarily utilize the carbohydrate fraction of lignocellulose, leaving lignin as a waste product. This makes lignin conversion to SAF critical in order to utilize whole biomass, thereby lowering overall production costs while maximizing carbon efficiencies. Thus, lignin valorization strategies are also reviewed herein with vital research areas identified, such as facile lignin depolymerization approaches, highly integrated conversion systems, novel process configurations, and catalysts for the selective cleavage of aryl C–O bonds. The potential efficiency improvements available via integrated conversion steps, such as combined biological and chemo-catalytic routes, along with the use of different parallel pathways, are identified as key to producing all components of a cost-effective, 100% SAF.

09 BIOMASS FUELS↗

Impact of installation faults in air conditioners and heat pumps in single-family homes on U.S. energy usage

To ensure that new residential air conditioners and heat pumps operate optimally, care must be taken during the initial system design and installation to avoid missteps that immediately degrade a system’s performance. Laboratory and simulation studies have quantified the impact that faults can have on capacity and efficiency. Field studies have demonstrated that installation-related faults are commonplace. However, the national impact of installation-related faults cannot be accurately estimated by only simulating a limited number of homes at several fault levels because of the variety of home characteristics and climates involved. In our analysis, we use an improved residential building stock simulation tool to predict the annual energy increase and additional utility costs resulting from two common installation faults: indoor airflow rate and refrigerant charge level. Our method considers the wide range of building characteristics and climate zones of the U.S. housing stock. We use existing field data to develop fault intensity probability distributions to inform our analysis. The study shows that these two faults result in approximately 20.7 TWh/y of additional energy use for central air conditioners and air-source heat pumps in U.S. single-family detached homes, which is a 9% increase over baseline (no-fault) usage, costing homeowners approximately $2.5 billion annually on utility bills. Air-source heat pumps are responsible for a disproportionate fraction of this energy use increase because of the larger number of operating hours compared to central air conditioners and the sensitivity of heating mode performance to the faults analyzed compared to cooling mode.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Biaxial steel plated concrete constitutive models for composite structures: Implementation and validation

The Steel-plated Concrete (SC) technique is an alternative construction technique with faster onsite construction speed, reduced construction time, and increased structural performance. Aiming to predict the force transfer mechanism of SC elements, an innovative constitutive model package is proposed by implementing experimental-based biaxial steel plate concrete models into the nonlinear finite element (FE) model “Membrane Model of SC (MM-CS).” First, the formulation and implementation of the MM-SC is illustrated in detail, including the equilibrium and compatibility equations and the implementation of constitutive models. Next, various experimental data of SC members are selected and simulated using the proposed MM-SC model. In this research, two types of structures, SC panels and framed SC shear walls, and three types of loading conditions, including uniaxial compression, pure shear, and combined axial-flexural-shear tests, are analyzed respectively. Good agreements were obtained between the reported results and the FE simulation results in terms of yield capacity and ultimate capacity, proving the reliability of the implemented analytical constitutive material models and the biaxial membrane model formulations.

42 ENGINEERING↗

Next Generation Integrated PV Products Cost and Workflow Analysis (Final Report)

Residential photovoltaic (PV) costs have fallen consistently for over a decade (Ardani et al. 2018). DOE has subsequently developed a new residential PV cost target for 2030 of $0.05/kilowatt hour (SETO 2023). Ardani et al. (2018) conclude that integrated roofing and PV (RIPV) products may be key to achieving the residential target for both new construction and retrofit residential PV. In RIPV, the PV product is incorporated into or replaces the roofing material. RIPV systems can use conventional crystalline or thin-film technologies, may be aesthetically attractive alternatives to traditional racked and mounted PV systems, and may increase building property values (Cook et al. 2023). These products also have the potential to provide customer acquisition, labor, and equipment cost savings over traditional, racked and mounted residential rooftop PV and several companies have recently introduced integrated roofing and PV (RIPV) products (Cook et al. 2023). In 2022, Tesla was the market leader, representing 94% of RIPV capacity installed in 2022 through its Solar Roof offering, while GAF Energy and its Timberline Solar product was second capturing 3% (Feldman et al. 2023). In this project, NREL analyzed three research questions: (1) How do current RIPV products compare to racked and mounted PV in terms of costs, install times and processes? (2) How are RIPV products installed and are there opportunities for cost savings? (3) What are the key barriers to expanding market opportunities for integrating solar and roofing products? In this project, we explored residential RIPV cost reduction opportunities by analyzing installation processes. Our study documented residential RIPV installations at two reroofing sites (20.52 kilowatts) and the equivalent of nine new construction sites (71.75 kW) in California through a methodology known as time and motion study. We also conducted 15 interviews with subject-matter experts to identify barriers and solutions to maximize these products' market penetration.

14 SOLAR ENERGY↗

“Smarter” NICs for faster algorithms [Slides]

The basic building block of a distributed-memory cluster or supercomputer is a node. Each node includes a host, which is a processor (xPU) + memory hierarchy. The host can communicate with other hosts via its NIC (network interface controller). A network connects the nodes. The nodes may be arranged in some topology, which determines the network’s carrying capacity and cost.

97 MATHEMATICS AND COMPUTING↗

In Situ Air Temperature and Humidity Measurements Over Diverse Land Covers in Greenbelt, Maryland, November 2013-November 2015

As our climate changes through time there is an ever-increasing need to quantify how and where it is changing so that mitigation strategies can be implemented. Urban areas have a disproportionate amount of warming due, in part, to the conductive properties of concrete and asphalt surfaces, surface albedo, heat capacity, lack of water, etc. that make up an urban environment. The NASA Climate Adaptation Science Investigation working group at Goddard Space Flight Center in Greenbelt, MD, conducted a study to collect temperature and humidity data at 15 min intervals from 12 sites at the center. These sites represent the major surface types at the center: asphalt, building roof, grass field, forest, and rain garden. The data show a strong distinction in the thermal properties of these surfaces at the center and the difference between the average values for the center compared to a local meteorological station. The data have been submitted to Oak Ridge National Laboratory Distributed Active Archive Center (ORNL-DAAC) for archival in comma separated value (csv) file format (Carroll et al.,2016) and can be found by following this link: http:daac.ornl.govcgi-bindsviewer.pl?ds_id1319.

Carroll, Mark L.↗

Seamlessly Fuel Flexible Heat Pump with Optimal Model-based Control Strategies to Reduce Peak Demand, Utility Cost and CO2 Emission

This research develops a novel hybrid fuel heat pump system for space heating of residential and small commercial buildings with built-in optimization and control. Whereas conventional dual fuel systems either run on gas or electricity at any given moment, the proposed seamlessly fuel flexible heat pump (SFFHP) simultaneously consumes gas and electricity and continuously optimizes the proportion of each. The building air flows across the heat pump condenser first and then flows across the furnace coil, and this reduces the heat pump temperature lift. The SFFHP delivers energy savings by allowing each subsystem (gas furnace and electric heat pump) to operate where it performs best to improve energy efficiency, minimize energy cost, and minimize carbon footprint. The capacities of the electric heat pump and gas furnace are continuously adjusted based on ambient conditions, utility price signals, and marginal grid emission signals. An optimal model predictive control strategy was developed with the goal of minimizing utility cost and minimizing CO2 emission. Two case studies were conducted to simulate the performance of SFFHP during the heating season in Chicago and Los Angeles, respectively. Compared with a conventional electric heat pump, SFFHP yields 33% utility cost reduction and 49% CO2 emission reduction in Chicago. Similarly, it achieves 23% utility cost reduction and 17% CO2 emission reduction in Los Angeles. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. Due to the hybrid fuel nature of this novel equipment, user comfort will always be maintained. The fuel flexibility makes it an attractive option for demand response programs.

Li, Zhenning↗

It's Not Just About the Megawatts - ARC Industry Forum, The Future of Power Generation

As the world transitions to less carbon intensive energy portfolios, much of the attention understandably centers on generating capacity – replacing megawatts of fossil fuel with megawatts of solar, wind, nuclear, hydroelectric, hydrogen, and more. The actual operation of a reliable grid needs more than just megawatts though: adequate quantities of a portfolio of essential reliability services; flexible and capable power delivery systems; governance to operate in 5-10 minute intervals, forecast hourly, and plan and build on a generational time horizon; and dependable and secure communications. We can choose our fuel mix for climate reasons, but the grid itself and the society that relies upon it impose constraints on those choices that we ignore at our peril.

13 HYDRO ENERGY↗

Parametric optimization of PCM-enhanced underground thermal energy storage for buildings in moderate cold climates

This study presents a novel underground thermal energy storage (UTES) system designed for space heating in buildings located in moderate cold climates. The proposed UTES features a borehole with a depth of 25 ft. (7.62 m) and a diameter of 3 ft. (0.91 m), containing two helical pipe loops-one for discharge fluid and another for recharge fluid-and a thermally enhanced phase change material (PCM) layer that provides high energy storage capacity. The system requires daily thermal recharging using a low-grade heat source for a few hours and delivers continuous heating at a nearly constant discharge rate without significant performance degradation over a 24-h period. This study demonstrates that the optimized UTES, when recharged with hot fluid at an inlet temperature of 40 degrees C for 6 h daily, can provide a continuous heat discharge rate of approximately 2.9 kW for 24 h or 3.4 kW if operated under a shorter discharge period of 15 h (17:00-08:00). With a round-trip efficiency of 72-97%, the proposed UTES offers an efficient and reliable solution for short- and long-duration thermal energy storage technology, making it a promising technology for cold climates.

15 GEOTHERMAL ENERGY↗