Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMFORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Winnett Public School District Energy Improvements

The Winnett Public School District Energy Improvement Project was funded through the U.S. Department of Energy's Renew America's Schools Program, which supports rural and underserved school districts in upgrading aging facilities and improving energy performance. The completed improvements directly advance the program's objectives by replacing the District's outdated coal-fired heating system with a modern, high-efficiency propane boiler system, while also enhancing ventilation systems and building envelope performance throughout the school. These upgrades provide a more reliable heating system and improved indoor air quality, creating a healthier and more comfortable environment for students and staff. In addition, replacing the aging boiler system has reduced long-term maintenance demands for one of Montana's most rural school districts, allowing the District to redirect limited financial resources toward other critical needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Pumps and Energy Recovering Ventilators in Northern Alaska

The intended purpose of this project was to bring alternative heat and ventilation options to rural communities off the road system in Northwestern Alaska. Most of the residents of these communities are reliant upon kerosene or other fossil fuels to provide heat to their homes. Our intention was to offer an alternative to using those sources by providing heat pumps to 45 homes in the communities of Elim and Koyuk. When projecting energy use for these units based on the fuel prices at the time, it was discovered that energy costs for heat pumps would equal or slightly exceed the costs of existing kerosene units. Secondly, as part of our E&l grant we installed 45 energy recovery ventilators (ERV’s) in those same homes. This was important given our experience over the years with moisture and comfort issues in most homes within this region. Exhaust-only systems are rarely used due to the high heating costs. Additionally, exhaust-only systems have a potential risk of back drafting due to tight building construction. Balanced systems like this eliminate that risk while improving indoor air quality. Another benefit to these types of systems is the fact that they help transfer heat from a single heat source equally throughout the building. Our overall goal was to offer new technology options to improve these structures and the families that reside in them where, given their location and extreme seasonal temperature swings, they have historically never been offered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real-Time Inference For MI/RR Deblending

The Fermilab Main Injector (MI) and Recycler Ring (RR) share a common beam loss monitor (BLM) system, making loss events difficult to attribute to their source machine when beam is present in both simultaneously. The Real-time Edge AI for Distributed Systems (READS) project addresses this by deblending BLM readings in real time using machine learning (ML). The current FPGA based implementation meets the sub-3 ms latency requirement but carries a resource intensive hls4ml development cycle, motivating exploration of GPU based deployment. This paper characterizes inference latency on an NVIDIA Jetson Orin Nano and introduces a packet organization scheme for assembling synchronized event frames from seven distributed BLM DAQ streams. Using a Python based DAQ simulation with injected timing jitter in place of unavailable live beam data, the pipeline achieved an average end to end latency of 0.456 ms (σ = 0.122 ms) across 167,000 test frames, comfortably meeting the timing constraint. Early outliers were attributed to TensorRT warm-up rather than steady state limitations, suggesting GPU based inference is a viable alternative to the existing FPGA implementation.

Yu, Kellen [Cornell U.]↗

Science and Technology Review December 2009

This month's issue has the following articles: (1) Advanced Materials for Our Past, Present, and Future - Commentary by Tomas Diaz de la Rubia; (2) A Defensive 'Coat' for Materials under Attack - Amorphous metal coatings provide the strength and corrosion resistance needed to protect military vessels and spent nuclear fuel containers; (3) Too Close for Comfort - Laboratory scientists are analyzing the feasibility of using nuclear explosives to disrupt or divert asteroids on a collision course with Earth; (4) Hyperion: A Titan of High-Performance Computing Systems - Livermore is collaborating with 10 computing industry leaders to create a test bed for Linux cluster hardware and software technologies; (5) Isolating Pathogens for Speedy Identification - An automated miniature device separates viruses, bacteria, genetic material, and proteins from nasal swabs and blood and urine samples for speedy identification.

36 MATERIALS SCIENCE↗

Building America Best Practices Series, Volume 9: Builders Challenge Guide to 40% Whole-House Energy Savings in the Hot-Dry and Mixed-Dry Climates

This best practices guide is the ninth in a series of guides for builders produced by the U.S. Department of Energy’s Building America Program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the hot-dry and mixed-dry climates can achieve homes that have whole house energy savings of 40% over the Building America benchmark (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code) with no added overall costs for consumers. These best practices are based on the results of research and demonstration projects conducted by Building America’s research teams. The guide includes information for managers, designers, marketers, site supervisors, and subcontractors, as well as case studies of builders who are successfully building homes that cut energy use by 40% in the hot-dry and mixed-dry climates.

54 ENVIRONMENTAL SCIENCES↗

Results of the 2008/2009 Knowledge and Opinions Surveys Conducted for the U.S. Department of Energy Hydrogen Program

The U.S. Department of Energy (DOE) Fuel Cell Technologies Program (FCT) conducts comprehensive efforts to enable the widespread commercialization of fuel cells in diverse sectors of the economy - with emphasis on applications that will most effectively strengthen our nation's energy security and improve our stewardship of the environment. Expanding the use of fuel cells requires a sustained education effort to lay the foundation for future commercial market introduction. The FCT education subprogram seeks to facilitate fuel cell demonstrations and support future commercialization by providing technically accurate and objective information to key target audiences both directly and indirectly involved in the use of fuel cells today. These key target audiences include a public that is familiar and comfortable with using a new fuel, state and local government officials who understand the near-term realities and long-term potential of the technology, an educated business and industry component, and trained safety and codes officials. With this in mind, the DOE FCT program established an education key activity to address the training and informational needs of target audiences that have a role in the near-term transition and the long-term development of a hydrogen economy. Whether or not changes can be attributed to the program, designing and maintaining an effective education program entails measuring baseline awareness and periodically measuring what has been learned. The purpose of this report is to document the data and results of statistical surveys undertaken in 2008 and 2009 to measure and establish changes in understanding and awareness about hydrogen and fuel cell technologies since a baseline survey was conducted in 2004. This report is essentially a data book, a digest of the survey data and an exposition of changes in knowledge of and opinions about hydrogen and fuel cell technology since 2004. Many conclusions can be made from the survey data. However, the purpose here is not to draw the conclusions, but rather to summarize the data in a way that facilitates drawing them. It is envisioned that the same statistical surveys will be fielded again in approximately three years.

08 HYDROGEN↗

Feasibility of Achieving a Zero-Net-Energy, Zero-Net-Cost Homes

A green building competition, to be known as the Energy Free Home Challenge (EFHC), is scheduled to be opened to teams around the world in 2010. This competition will encourage both design innovation and cost reduction, by requiring design entries to meet 'zero net energy' and 'zero net cost' criteria. For the purposes of this competition, a 'zero net energy' home produces at least as much energy as it purchases over the course of a year, regardless of the time and form of the energy (e.g., electricity, heat, or fuel) consumed or produced. A 'zero net cost' home is no more expensive than a traditional home of comparable size and comfort, when evaluated over the course of a 30-year mortgage. In other words, the 'green premium' must have a payback period less than 30 years, based on the value of energy saved. The overarching goal of the competition is to develop affordable, high-performance homes that can be mass-produced at a large scale, and are able to meet occupant needs in harsh climates (as can be found where the competition will be held in Illinois). This report outlines the goals of the competition, and gauges their feasibility using both modeling results and published data. To ensure that the established rules are challenging, yet reasonable, this report seeks to refine the competition goals after exploring their feasibility through case studies, cost projections, and energy modeling. The authors of this report conducted a survey of the most progressive home energy-efficiency practices expected to appear in competition design submittals. In Appendix A, a summary can be found of recent projects throughout the United States, Canada, Germany, Switzerland, Sweden and Japan, where some of the most progressive technologies have been implemented. As with past energy efficient home projects, EFHC competitors will incorporate a multitude of energy efficiency measures into their home designs. The authors believe that the cost of electricity generated by home generation technologies will continue to exceed the price of US grid electricity in almost all locations. Strategies to minimize whole-house energy demand generally involve some combination of the following measures: optimization of surface (area) to volume ratio; optimization of solar orientation; reduction of envelope loads; systems-based engineering of high efficiency HVAC components, and on-site power generation. A 'Base Case' home energy model was constructed, to enable the team to quantitatively evaluate the merits of various home energy efficiency measures. This Base Case home was designed to have an energy use profile typical of most newly constructed homes in the Champaign-Urbana, Illinois area, where the competition is scheduled to be held. The model was created with the EnergyGauge USA software package, a front-end for the DOE-2 building energy simulation tool; the home is a 2,000 square foot, two-story building with an unconditioned basement, gas heating, a gas hot-water heater, and a family of four. The model specifies the most significant details of a home that can impact its energy use, including location, insulation values, air leakage, heating/cooling systems, lighting, major appliances, hot water use, and other plug loads. EFHC contestants and judges should pay special attention to the Base Case model's defined 'service characteristics' of home amenities such as lighting and appliances. For example, a typical home refrigerator is assumed to have a built-in freezer, automatic (not manual) defrost, and an interior volume of 26 cubic feet. The Base Case home model is described in more detail in Section IV and Appendix B.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Pilot Study of the Effectiveness of Indoor Plants for Removal of Volatile Organic Compounds in Indoor Air in a Seven-Story Office Building

The Paharpur Business Centre and Software Technology Incubator Park (PBC) is a 7 story, 50,400 ft{sup 2} office building located near Nehru Place in New Delhi India. The occupancy of the building at full normal operations is about 500 people. The building management philosophy embodies innovation in energy efficiency while providing full service and a comfortable, safe, healthy environment to the occupants. Provision of excellent Indoor Air Quality (IAQ) is an expressed goal of the facility, and the management has gone to great lengths to achieve it. This is particularly challenging in New Delhi, where ambient urban pollution levels rank among the worst on the planet. The approach to provide good IAQ in the building includes a range of technical elements: air washing and filtration of ventilation intake air from rooftop air handler, the use of an enclosed rooftop greenhouse with a high density of potted plants as a bio-filtration system, dedicated secondary HVAC/air handling units on each floor with re-circulating high efficiency filtration and UVC treatment of the heat exchanger coils, additional potted plants for bio-filtration on each floor, and a final exhaust via the restrooms located at each floor. The conditioned building exhaust air is passed through an energy recovery wheel and chemisorbent cartridge, transferring some heat to the incoming air to increase the HVAC energy efficiency. The management uses 'green' cleaning products exclusively in the building. Flooring is a combination of stone, tile and 'zero VOC' carpeting. Wood trim and finish appears to be primarily of solid sawn materials, with very little evidence of composite wood products. Furniture is likewise in large proportion constructed from solid wood materials. The overall impression is that of a very clean and well-kept facility. Surfaces are polished to a high sheen, probably with wax products. There was an odor of urinal cake in the restrooms. Smoking is not allowed in the building. The plants used in the rooftop greenhouse and on the floors were made up of a number of species selected for the following functions: daytime metabolic carbon dioxide (CO{sub 2}) absorption, nighttime metabolic CO{sub 2} absorption, and volatile organic compound (VOC) and inorganic gas absorption/removal for air cleaning. The building contains a reported 910 indoor plants. Daytime metabolic species reported by the PBC include Areca Palm, Oxycardium, Rubber Plant, and Ficus alii totaling 188 plants (21%). The single nighttime metabolic species is the Sansevieria with a total of 28 plants (3%). The 'air cleaning' plant species reported by the PBC include the Money Plant, Aglaonema, Dracaena Warneckii, Bamboo Palm, and Raphis Palm with a total of 694 plants (76%). The plants in the greenhouse (Areca Palm, Rubber Plant, Ficus alii, Bamboo Palm, and Raphis Palm) numbering 161 (18%) of those in the building are grown hydroponically, with the room air blown by fan across the plant root zones. The plants on the building floors are grown in pots and are located on floors 1-6. We conducted a one-day monitoring session in the PBC on January 1, 2010. The date of the study was based on availability of the measurement equipment that the researchers had shipped from Lawrence Berkeley National Lab in the U.S.A. The study date was not optimal because a large proportion of the regular building occupants were not present being New Year's Day. An estimated 40 people were present in the building all day during January 1. This being said, the building systems were in normal operations, including the air handlers and other HVAC components. The study was focused primarily on measurements in the Greenhouse and 3rd and 5th floor environments as well as rooftop outdoors. Measurements included a set of volatile organic compounds (VOCs) and aldehydes, with a more limited set of observations of indoor and outdoor particulate and carbon dioxide concentrations. Continuous measurements of Temperature (T) and relative humidity (RH) were made selected indoor and outdoor locations.

54 ENVIRONMENTAL SCIENCES↗

INL High Performance Building Strategy

High performance buildings, also known as sustainable buildings and green buildings, are resource efficient structures that minimize the impact on the environment by using less energy and water, reduce solid waste and pollutants, and limit the depletion of natural resources while also providing a thermally and visually comfortable working environment that increases productivity for building occupants. As Idaho National Laboratory (INL) becomes the nation’s premier nuclear energy research laboratory, the physical infrastructure will be established to help accomplish this mission. This infrastructure, particularly the buildings, should incorporate high performance sustainable design features in order to be environmentally responsible and reflect an image of progressiveness and innovation to the public and prospective employees. Additionally, INL is a large consumer of energy that contributes to both carbon emissions and resource inefficiency. In the current climate of rising energy prices and political pressure for carbon reduction, this guide will help new construction project teams to design facilities that are sustainable and reduce energy costs, thereby reducing carbon emissions. With these concerns in mind, the recommendations described in the INL High Performance Building Strategy (previously called the INL Green Building Strategy) are intended to form the INL foundation for high performance building standards. This revised strategy incorporates the latest federal and DOE orders (Executive Order [EO] 13514, “Federal Leadership in Environmental, Energy, and Economic Performance” [2009], EO 13423, “Strengthening Federal Environmental, Energy, and Transportation Management” [2007], and DOE Order 430.2B, “Departmental Energy, Renewable Energy, and Transportation Management” [2008]), the latest guidelines, trends, and observations in high performance building construction, and the latest changes to the Leadership in Energy and Environmental Design (LEED®) Green Building Rating System (LEED 2009). The document employs a two-level approach for high performance building at INL. The first level identifies the requirements of the Guiding Principles for Sustainable New Construction and Major Renovations, and the second level recommends which credits should be met when LEED Gold certification is required.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aprendizaje vertical

In the teaching and learning events of our life, there are characters who play key roles. Teachers, mentors, relatives, novels, songs, newspaper columns, often help us understand the questions in our heads. However, we often reject them because they are messages or attitudes from older people and the generation gap does not allow us to understand them well. The times of covid-19 have us locked up at home. They alert us that precisely “elderly people” are a vulnerable group. Also, we have been asked to take care of grandparents. If we are lucky enough to have an internet connection, it seems that we can learn anything we want with just one click. This could lead us to explore only what we find attractive, easy and comfortable. With this testimony, I invite you to acknowledge on the role of the elderly in the learning of entire generations. I call for openness towards diverse voices and for the understanding that we all play a role in moving towards a more mature society.

99 GENERAL AND MISCELLANEOUS↗

Data-driven Thermal Model Inference with ARMAX, in Smart Environments, based on Normalized Mutual Information

Understanding the models that characterize the thermal dynamics in a smart building is important for the comfort of its occupants and for its energy optimization. Here, a significant amount of research has attempted to utilize thermodynamics (physical) models for smart building control, but these approaches remain challenging due to the stochastic nature of the intermittent environmental disturbances. This paper presents a novel data-driven approach for indoor thermal model inference, which combines an Autoregressive Moving Average with eXogenous inputs model (ARMAX) with a Normalized Mutual Information scheme (NMI). Based on this information-theoretic method, NMI, causal dependencies between the indoor temperature and exogenous inputs are explicitly obtained as a guideline for the ARMAX model to find the dominating inputs. For validation, we use three datasets based on building energy systems-against which we compare our method to an autoregressive model with exogenous inputs (ARX), a regularized ARMAX model, and state-space models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantification of Load Flexibility in Residential Buildings Using Home Energy Management Systems

With increasing penetration of renewable energy resources, the flexibility of operating behind-the-meter (BTM) resources plays a key role in enhancing grid reliability and resilience. Residential buildings with home energy management systems (HEMS) can provide desired flexibility for the distribution system operator (DSO) while considering customer comfort and preferences. This paper discusses a methodology to quantify the flexibility of BTM resources of residential buildings using HEMS. First, we propose a model predictive control framework to formulate the flexibility band comprising nominal, upper, and lower demand profiles. Second, the paper proposes a dispatch method for HEMS to compute the control signals for each BTM resource (e.g., air conditioner, water heater, home battery system) upon receiving a flexibility service request from the DSO. The case study provides insight into the flexibility provided at the whole-home level with different user preferences and seasons. The results demonstrate that HEMS is capable of providing flexibility service at the request of the DSO while delivering primary services to the building occupants.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Transfer Learning for HVAC System Fault Detection

Faults in HVAC systems degrade thermal comfort and energy efficiency in buildings and have received significant attention from the research community, with data driven methods gaining in popularity. Yet the lack of labeled data, such as normal versus faulty operational status, has slowed the application of machine learning to HVAC systems. In addition, for any particular building, there may be an insufficient number of observed faults over a reasonable amount of time for training. To overcome these challenges, we present a transfer methodology for a novel Bayesian classifier designed to distinguish between normal operations and faulty operations. The key is to train this classifier on a building with a large amount of sensor and fault data (for example, via simulation or standard test data) then transfer the classifier to a new building using a small amount of normal operations data from the new building. We demonstrate a proof-of-concept for transferring a classifier between architecturally similar buildings in different climates and show few samples are required to maintain classification precision and recall.

transfer learning, Building HVAC, Bayesian framewo↗

Grid-Interactive Multi-Zone Building Control Using Reinforcement Learning with Global-Local Policy Search

In this paper, we develop a grid-interactive multi-zone building controller based on a deep reinforcement learning (RL) approach. The controller is designed to facilitate building operation during normal conditions and demand response events, while ensuring occupants comfort and energy efficiency. We leverage a continuous action space RL formulation, and devise a two-stage global-local RL training framework. In the first stage, a global fast policy search is performed using a gradient-free RL algorithm. In the second stage, a local fine-tuning is conducted using a policy gradient method. In contrast to the state-of-the-art model predictive control (MPC) approach, the proposed RL controller does not require complex computation during real-time operation and can adapt to nonlinear building models. We illustrate the controller performance numerically using a five-zone commercial building.

30 DIRECT ENERGY CONVERSION↗

Dataset for: Rooftop solar and energy storage programs can remediate energy-limiting behaviors of energy insecure households

Energy insecurity affects most low-income households in the United States. Energy insecurity, which is characterized by a household’s inability to afford their energy needs, often leads to risky choices, causing other forms of insecurity including food and health. Although there are government programs designed to provide relief to low-income households that face energy insecurity, eligibility for these programs is usually determined by household income, and those with incomes close to the threshold face uncertainty or may be left out. In many cases, these households turn to energy-limiting behaviors as a strategy to lower their electric utility bills. This paper explores the relationship between energy insecurity and energy-limiting behaviors to investigate alternative solutions that target the households that may fall out of available energy assistance programs. We explore the role of battery energy storage systems and rooftop solar photovoltaics in improving energy affordability. The results show that residential rooftop solar and behind-the-meter energy storage can offset two-thirds of the bill savings that households attain through energy-limiting behavior. Household renewable energy systems could complement existing energy assistance programs to provide long-term bill relief, enabling occupants to live in their homes with comfort and dignity. This dataset is intended to allow readers to reproduce and customize the analysis performed in this work to their benefit.

Kerby, Jessica [Pacific Northwest National Laborat↗

Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate

Understanding indoor humidity conditions in low energy homes in hot-humid climates is critical to promoting long term occupant comfort, indoor air quality and building durability. The results of this study were expected to inform the residential building community on whether supplemental dehumidification is a needed and effective investment to promote these long term standards. Data logging equipment was installed at eight test homes in July, 2012 and later at two more test homes in January, 2013. Interior conditions and various end-use loads were monitored until November 7th, 2013. The mechanical systems at each of the 10 homes were commissioned by BSC to ensure consistent operation between each of the homes and to fully comply with the intended mechanical design. PHA-1 to 8 - Energy Savings: 21.8-18.9%, Company: Project Home Again (PHA); Address New Orleans, LA 70112, House Count: 8 BDC-1 - Energy Savings: 28.8%, Company: Broadmoor Development Corporation (BDC); Address New Orleans, LA 70112, House Count: 2

Array↗

Mini-Split Heat Pump Evaluation and Zero Energy Ready Home Support

This project was created from a partnership between the U.S. Department of Energy's (DOE's) Building America research team, IBACOS, Inc., and a production builder of high-performance homes called Imagine Homes, which is located in San Antonio, Texas-a hot-humid climate. The primary purpose of this project was to evaluate the performance of a multihead mini-split heat pump (MSHP) space-conditioning system in maintaining uniform comfort in an occupied test house. My Design - PV: Test house design characteristics, with installed PV system DESIGN - Occupied Test House with PV: Design used for one occupied test house including PV STRUCTURE - Platinum Court San Antonio, TX: Occupied test house in 2013

Array↗

Greenbuilt Construction Energy Efficiency Retrofit House Demonstration - Sacramento

One of the homes that was part of Sacramento Municipal Utility District's (SMUD) Energy Efficiency Retrofit Demonstration (EERD) project was a 1980's era home in Fair Oaks, California, referred to as the Greenbuilt house, as Greenbuilt Construction completed the retrofit of the home. The home underwent an extensive energy efficiency retrofit with a goal of achieving a 50% reduction in energy use to demonstrate the potential for other builders and homeowners in the area. The retrofit measures included installing: ENERGY STAR appliances high efficiency light roof radiant barrier additional ceiling and wall insulation double-pane, low-e windows external motorized shading and solar tubes a 16 SEER/9.75 HSPF heat pump improved ducts a whole-house fan a heat pump water heater (HPWH) integrated collector storage solar water heater (ICS SWH) and 3.2 kW of PV. In addition, the home was air sealed to reduce infiltration. Researchers from the National Renewable Energy Laboratory (NREL) performed short-term tests on the major systems installed as part of the retrofit to ensure that they were performing as expected. The systems evaluated included the space conditioning heat pump, the air handler and ducts, the HPWH, the ICS SWH, and the PV array. Some ducts were untwisted after testing revealed that two rooms were not getting sufficient airflow. Afterwards, all systems were performing as expected. In addition to testing to confirm adequate performance of all new systems, NREL was given the opportunity to use the Greenbuilt house as a laboratory house for a year. The space conditioning system and home water systems were subjected to a series of tests to determine optimal control strategies for lowering energy consumption and reducing peak (4:00-7:00 p.m.) energy consumption during the summer. The different cooling strategies considered included two different precooling schedules, drawing the external shades during the day and using the whole-house fan at night, and combinations of those. The most effective strategy for reducing overall energy consumption was the use of external shades, which cut the daily cooling load by 34% and reduced the energy use during peak hours by 40%. The different precooling strategies eliminated the peak load entirely but actually increased daily cooling energy use. The use of shades and the advanced precooling strategy increased the daily energy use by 5% but eliminated all peak use and maintained a comfortable home. These results were verified over the entire summer using an Energy Plus model of the home. The hot water system was tested in two configurations: the HPWH alone and the ICS solar water heater paired with the HPWH. Six hot water draw profiles, varying in terms of daily hot water volume, time of day for hot water use, and the duration of the draws, were imposed on the hot water system to test their effects on performance. When operating alone in the summer, the HPWH operated with a COP around 2.2, except for a draw that used a quarter of the averaged daily hot water usage, which had an average COP of 1.6. The combination of ICS and HPWH resulted in larger COPs, but also more variability depending on the draw profile. The standard, hourly draw profile produced the highest COP of 6.4. The quarter volume draw profile had the lowest COP of 2.8 for the combined system. Relative to a standard electric water heater, the HPWH operating alone reduced the peak load by 56% and the combined ICS and HPWH system completely eliminated the peak load.

air sealing↗