Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Astronomy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Balloon-borne 3-meter telescope for far-infrared and submillimeter astronomy

The gimbal design was studied and revised to eliminate the alignment and limited rotation problems inherent in the flex-pivot design. A new design using ball-bearings to replace the flex-pivot was defined and its performance analyzed. An error analysis for the entire gondola pointing system was also prepared. Mirror development and the test program using mirror test blanks from Dornier were continued.

Fazio, G. G.↗

Astronomy on a manned Mars mission

Three extra-solar-system astronomical experiments onboard a manned Mars mission are proposed. First, a modest, 50 cm aperture optical-ultraviolet-infrared telescope (or pair used as an interferometer) coupled with the Mars-Sun baseline would increase the number (by a factor of 3.4) and a volume of stars with accurately measured distances via stellar parallax and, therefore, greatly improve upon the cosmic distance scale; the darker sky at Mars would also provide nearly a full astronomical magnitude deeper images of distant and low brightness objects (limited by zodiacal light). Second, a gamma-ray burst detector coupled with similar detectors in other parts of the solar system will be used to reduce the position error boxes and to study the nature of these energetic sources. Third, the long baselines on a Mars mission radio interferometer will provide a view of the radio universe at unprescedented resolution, 4 x 10 to the minus 9th arcsec at 1 mm wavelength, which can potentially resolve the engine in nearby active galaxies. Each of these experiments is relatively inexpensive, taking advantage of the human presence for operation and maintenance, and the long Earth to Mars baseline.

Burns, Jack O.↗

Manned Mars mission astronomy options

Astronomical observations during the transit phase, in orbit about Mars, and from the surface present important scientific objectives. Primary astronomical objectives are being summarized by J. Burns (University of New Mexico). Additional or alternative options will be introduced here, together with their strengths, weaknesses, viability, and value. It is important to note at the outset that not all possible options are necessarily important or viable.

Suess, S. T.↗

Research in extreme ultraviolet and far ultraviolet astronomy

Analysis and interpretation continued on data generated by the flight of 27.086 in April of 1986 and by the successful UVX mission. Optical and mechanical design of the 1 meter EUV telescope, planned for launch with the large SPARTAN type carrier, ASTRO-SPAS, was also continued. The major effort centered on the preparation of flight 27.106, scheduled to launch in September, 1986. Work which was performed included: design of the skins and bulkheads; completion of the optical, mechanical, and electrical design; purchase of the major components of the instruments; assemblage of the electrical components; and performance of theoretical work, to support the data interpretation.

Bowyer, C. S.↗

Thermal stability tests of CFRP sandwich panels for far infrared astronomy

An account is given of fabrication methods and low temperature figure tests for CFRP sandwich panels, in order to ascertain their applicability to ultralightweight 3-m aperture primary mirrors for balloon-borne sub-mm and far-IF telescopes that must maintain a 1-2 micron rms surface figure accuracy at -40 to -50 C. Optical figure measurements on the first two of a series of four 0.5-m test panels, replicated to a spherical surface, show a radius-of-curvature change and astigmatism down to -60 C; this approximately follows the composite's theoretical predictions and implies that material and process control is excellent, so that the large scale changes observed can be compensated for.

Hoffmann, W. F.↗

Thermal stability of lightweight graphite glass sandwich reflectors for far infrared astronomy

Graphite fiber-reinforced glass matrix composites are being developed for a variety of structural applications requiring excellent thermomechanical stability. These materials are ideally suited for lightweight, high strength, thermally stable infrared mirrors because of their low density, low thermal expansion, high strength and stiffness, and their ability to be machined, replicated and figured using standard polishing techniques. These properties are particularly promising for applications such as a 3-meter balloon-borne far-infrared and submillimeter telescope mirror which must be both very lightweight and able to retain its figure accuracy when cycled between room temperature and its operating temperature of -50 C. This paper presents the results of a set of low temperature optical tests conducted to determine the figure stability of a 30-cm diameter, frit-bonded graphite/glass mirror in the +20 to -60 C temperature range using a 10.6 micron laser interferometer. The results indicate that the residual change in figure was less than 0.3 microns, rms.

Bluege, J. H.↗

Topics in gamma ray astronomy

Observations of gamma rays from solar flares, gamma ray bursts, the Galactic center, galactic nucleosynthesis, SS433, and Cygnus X-3, and their effects on astrophysical problems are discussed. It is observed that gamma ray spectra from solar flares are applicable to the study of particle acceleration and confinement and the determination of chemical abundances in the solar atmosphere. The gamma ray lines from the compact galactic object SS433 are utilized to examine the acceleration of jets, and analysis of the gamma ray lines of Cygnus X-3 reveal that particles can be accelerated in compact sources to ultrahigh energies.

Ramaty, R.↗

X-ray instrumentation in astronomy; Proceedings of the Meeting, Cannes, France, December 2-4, 1985

Recent developments in X-ray and EUV astronomical instrumentation are discussed in reviews and reports. Topics examined include optical systems for the NASA Advanced X-ray Astrophysics Facility (AXAF), specialized X-ray systems, advanced X-ray optics, gas-filled X-ray detectors, instrumentation for spectrometry on AXAF, X-ray and EUV spectrometers, microchannel plate detectors, and solid-state detectors.

Culhane, J. L.↗

Development of a multistep detector for X-ray astronomy

The addition of a preamplification region is shown to dramatically improve the performance of a standard multiwire proportional counter (MWPC). This improvement is a direct consequence of effecting a large degree of preamplification in a perfectly uniform electric field and then transferring a well defined portion of this charge to a MWPC running at a modest gain. In this way, very large overall gas gains can be achieved without compromising energy resolution. The resulting device is known as a multistep detector.

Ramsey, B. D.↗

A fluorescent gated proportional counter for X-ray astronomy

The development of a position-sensitive proportional counter having a large drift volume is reported. It incorporates a fluorescent gating technique which results in a large improvement in background rejection over conventional proportional counters, and in addition offers the benefit of enhanced energy resolution (predicted to be about 3 percent at 40 keV) above the K shell of Xe.

Ramsey, B. D.↗

High efficiency photon counting detectors for the FAUST Spacelab far ultraviolet astronomy payload

The performances of sealed tube microchannel-plate position sensitive detectors having transmission CsI photocathodes or opaque CsI photocathodes are compared. These devices were developed for the FAUST Spacelab payload to accomplish imaging surveys in the band between 1300 A and 1800 A. It is demonstrated that photocathode quantum efficiencies in excess of 40 percent at 1216 A have been achieved with the transmission and the opaque CsI photocathodes. The effect of the photoelectron trajectory on the spatial resolution is assessed. Spatial resolution of less than 70 microns FWHM has been obtained and is maintained up to event rates of 50,000/sec. Background rates of 0.55 events sq cm per sec have been achieved and low distortion (less than 1 percent) imaging has been demonstrated.

Siegmund, O. H. W.↗

Gas scintillation drift chambers with wave shifter read-out for hard X-ray astronomy

A major improvement in hard X-ray and gamma ray astrophysics could be provided by high pressure xenon time projection chambers where gas scintillation is used both for the measurement of the time of interaction and for the detection of the extracted electrons. This allows three dimensional imaging of naturally complex events (photoelectric interaction with escape photon, Compton scatter, and pair production). A novel read-out system based on wave shifter fibers, which is well suited to the high pressures and large areas required of a hard X-ray telescope is proposed. Expected performances are computed, potential problems are outlined, and the experimental effort to solve these problems are described.

Sadoulet, Bernard↗

Wedge and strip image readout systems for photon-counting detectors in space astronomy

EUV and far UV applications of wedge and strip anodes in photon-counting microchannel plate detector systems are discussed in light of performance data obtained as a result of EUV Explorer spacecraft open face detector and FAUST-Spacelab far UV sealed tube sensor calibrations. CsI quantum detection efficiencies of about 80 percent at 114 A and about 40 percent at 600 and 1300 A have been achieved; a position sensitivity of less than 10 microns is demonstrated, and the position resolution, image linearity, background rate, and flat-field characteristics are discussed.

Siegmund, O. H. W.↗

The design of an echelle spectrometer for diffuse extreme ultraviolet/far ultraviolet astronomy

The novel, relatively high-resolution nebular spectrometer design presented incorporates a mechanical precollimator with an objective echelle grating that proceeds to a cross-dispensing Wadsworth configuration; the minimum feasible number of reflections is employed in order to maximize EUV sensitivity. The configuration, which is noted to be capable of yielding a comparatively large field of view for optimal diffuse emission sensitivity, is compact and employs conventionally fabricated optical components and available microchannel plate detectors. The sensitivities obtainable approach the limit stipulated by Liouville's theorem.

Martin, Christopher↗

Hybrid analog/digital, large format, photon counting detectors for astronomy

The development of a new microchannel plate photon-counting detector with an analog readout method based on a resistive anode is reported. This detector exhibits extremely high, stable electron gains of 10 to the 8th. At this gain, the spatial resolution is no longer primarily limited by the noise of the resistive anode, so that digital methods of readout, such as discrete conductors, lose their advantage. These detectors can be readily scaled to 40 mm and 70 mm formats to match plate scales of 2-m (and larger) telescopes. New, high speed digital electronics fully exploit the high spatial and time resolution made possible by gains of this level. Analysis of the theoretical performance of this detector shows that the major limitation to the spatial resolution is the proximity focus of the photocathode and the first microchannel plate. The detector has been mated to an echelle spectrograph developed.

Crocker, J.↗

Application of wedge and strip image readout systems to detectors for astronomy

Microchannel plate (MCP) detector systems that use wedge and strip anodes for imaging radiation in the range 50 A to 8000 A are described. Test data, obtained from the calibration of the Extreme Ultraviolet Explorer Satellite detectors and the ARIA EUV aeronomy sensor is presented. The long-term performance characteristics of Z-stack microchannel plates are investigated and it is shown that stable operation is achieved after an initial settling period. Conventional and new anode designs and their potential for increasing the position resolution are discussed. Position resolution of better than 80 microns FWHM has been attained for 50 mm devices, and this is shown to be essentially independent of event location. Image nonlinearity of less than 0.3 percent has been achieved with stability to better than 0.1 percent. Differential nonlinearity of less than 1 percent and stability to better than 1 percent have been obtained. Measurements of the quantum efficiency of a CsI photocathode on an MCP are presented, demonstrating efficiencies as high as 47 percent.

Siegmund, O. H. W.↗

Balloon-borne three-meter telescope for far-infrared and submillimeter astronomy

The study and revision of the gimbal design of the Three-Meter Balloon Borne Telescope (TMBBT) is discussed. Efforts were made to eliminate the alignment and limited rotation problems inherent in the flex-pivot design. A new design using ball bearings to replace the flex-pivots was designed and its performance analyzed. An error analysis for the entire gondola pointing system was also prepared.

Fazio, Giovanni G.↗

Advanced Components for Spaceborne Infrared Astronomy

Basic improvements in the technology of low noise read-out systems for low background detectors were demonstrated. Using discrete JFET integrating amplifiers at their optimum temperature of 55 K, read noise less than 7.5 electrons in 128 seconds of integration was obtained. Two models of single channel integrators are now available, the JF-77 for use between 50 and 80 K and the JF-4 for lower temperatures. A 1 x 15 linear array of complete integrators on a single integrated circuit was developed and will be made available in the near future. The successful operation of a superconducting stepper motor was demonstrated. The motor shows a three fold increase in torque over conventional motors operating at room temperature. The success of the motor stems from the use of superconducting coils in conjunction with developments in bearings for cryogenic use, rare-earth rotors, and motor cooling techniques. The current state of development will allow the rapid development of motors optimized for specific applications. An electronic switch capable of resetting cooled JFET integrating amplifiers was developed. The JFET integrating amplifiers that use this switch have demonstrated read noise of less than 10 electrons. The JFET reset device exhibits an extremely high open impedance and low leakage current. Capacitance is sufficiently low so as not to impair amplifier sensitivity. The effects of transient switching charges are minimized by a compensation technique and variable transient current problems inherent to devices of this type are overcome by external circuity.

Davidson, Arnold W.↗