Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerator Control C#”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Statistical process control for IMRT dosimetric verification

Patient-specific measurements are typically used to validate the dosimetry of intensity-modulated radiotherapy (IMRT). To evaluate the dosimetric performance over time of our IMRT process, we have used statistical process control (SPC) concepts to analyze the measurements from 330 head and neck (H and N) treatment plans. The objectives of the present work are to: (i) Review the dosimetric measurements of a large series of consecutive head and neck treatment plans to better understand appropriate dosimetric tolerances; (ii) analyze the results with SPC to develop action levels for measured discrepancies; (iii) develop estimates for the number of measurements that are required to describe IMRT dosimetry in the clinical setting; and (iv) evaluate with SPC a new beam model in our planning system. H and N IMRT cases were planned with the PINNACLE{sup 3} treatment planning system versions 6.2b or 7.6c (Philips Medical Systems, Madison, WI) and treated on Varian (Palo Alto, CA) or Elekta (Crawley, UK) linacs. As part of regular quality assurance, plans were recalculated on a 20-cm-diam cylindrical phantom, and ion chamber measurements were made in high-dose volumes (the PTV with highest dose) and in low-dose volumes (spinal cord organ-at-risk, OR). Differences between the planned and measured doses were recorded as a percentage of the planned dose. Differences were stable over time. Measurements with PINNACLE{sup 3} 6.2b and Varian linacs showed a mean difference of 0.6% for PTVs (n=149, range, -4.3% to 6.6%), while OR measurements showed a larger systematic discrepancy (mean 4.5%, range -4.5% to 16.3%) that was due to well-known limitations of the MLC model in the earlier version of the planning system. Measurements with PINNACLE{sup 3} 7.6c and Varian linacs demonstrated a mean difference of 0.2% for PTVs (n=160, range, -3.0%, to 5.0%) and -1.0% for ORs (range -5.8% to 4.4%). The capability index (ratio of specification range to range of the data) was 1.3 for the PTV data, indicating that almost all measurements were within {+-}5%. We have used SPC tools to evaluate a new beam model in our planning system to produce a systematic difference of -0.6% for PTVs and 0.4% for ORs, although the number of measurements is smaller (n=25). Analysis of this large series of H and N IMRT measurements demonstrated that our IMRT dosimetry was stable over time and within accepted tolerances. These data provide useful information for assessing alterations to beam models in the planning system. IMRT is enhanced by the addition of statistical process control to traditional quality control procedures.

61 RADIATION PROTECTION AND DOSIMETRY↗

Structural design feasibility study of Space Station long spacer truss

The structural design and configuration feasibility of the long spacer truss assembly that will be used as part of the Space Station Freedom is the focus of this study. The structural analysis discussed herein is derived from the transient loading events presented in the Space Transportation System Interface Control Document (STS ICD). The transient loading events are liftoff, landing, and emergency landing loads. Quasi-static loading events were neglected in this study since the magnitude of the quasi-static acceleration factors is lower than that of the transient acceleration factors. Structural analysis of the proposed configuration of the long spacer truss with four longerons indicated that negative safety margins are possible. As a result, configuration changes were proposed. The primary configuration change suggested was to increase the number of truss longerons to six. The six-longeron truss appears to be a more promising structure than the four-longeron truss because it offers a positive margin of safety and more volume in its second bay (BAY2). This additional volume can be used for resupply of some of the orbital replacement units (such as a battery box). Note that the design effort on the long spacer truss has not fully begun and that calculations and reports of the negative safety margins are, to date, based on concept only.

Armand, Sasan C.↗

Control of Flow Separation Using Adaptive Airfoils

A novel way of controlling flow separation is reported. The approach involves using an adaptive airfoil geometry that changes its leading edge shape to adjust to the instantaneous flow at high angles of attack such that the flow over it remains attached. In particular, a baseline NACA 0012 airfoil, whose leading edge curvature could be changed dynamically by 400% was tested under quasi-steady compressible flow conditions. A mechanical drive system was used to produce a rounded leading edge to reduce the strong local flow acceleration around its nose and thus reduce the strong adverse pressure gradient that follows such a rapid acceleration. Tests in steady flow showed that at M = 0.3, the flow separated at about 14 deg. angle of attack for the NACA 0012 profile but could be kept attached up to an angle of about 18 deg by changing the nose curvature. No significant hysteresis effects were observed; the flow could be made to reattach from its separated state at high angles by changing the leading edge curvature.

Chandrasekhara, M. S.↗

Application of the NREL Test-to-Failure Protocol for PV Modules

Initial results of application of the NREL Test-to-Failure Protocol are presented and discussed. Six commercially available multicrystalline Si-cell flat-plate modules were subjected to the protocol with controls. The samples were divided among three test sequences, (1) 1000 hours of 85C/85% relative humidity with positive or negative 600 V bias to the active layers with respect to the grounded frame, (2) -40/85C thermal cycling with electrical load at the rated module power, and (3) an alternating sequence between tests (1) and (2). Application of the protocol manifested in the acceleration of degradation mechanisms seen in the field including backsheet delamination, corrosion, bubble formation within the laminate, discoloration of the antireflective coating, and localized heating with degradation of the backsheet as a result of moisture ingress, corrosion, and concentrated current flow. Significant differences in performance after one round of the protocol are seen in damp heat depending on the polarity of the bias applied to the active layer (the short-circuited power leads of the module). The protocol is found to successfully accelerate module degradation mechanisms that have been observed in the field and will help to differentiate the performance and reliability of various module technologies.

14 SOLAR ENERGY↗

Well-Defined Rhodium–Gallium Catalytic Sites in a Metal–Organic Framework: Promoter-Controlled Selectivity in Alkyne Semihydrogenation to E -Alkenes [Well-Defined Rh–Ga Catalytic Sites in a Metal–Organic Framework: Promoter-Controlled Selectivity in Alkyne Semihydrogenation to E -Alkenes]

Promoters are ubiquitous in industrial heterogeneous catalysts. The wider roles of promoters in accelerating catalysis and/or controlling selectivity are, however, not well understood. A model system has been developed where a heterobimetallic active site comprising an active metal (Rh) and a promoter ion (Ga) are preassembled and delivered onto a metal-organic framework (MOF) support, NU-1000. The Rh-Ga sites in NU-1000 selectively catalyze the hydrogenation of acyclic alkynes to E -alkenes. The overall stereoselectivity is complementary to the well-known Lindlar’s catalyst, which generates Zalkenes. In conclusion, the role of the Ga in promoting this unusual selectivity is evidenced by the lack of semihydrogenation selectivity when Ga is absent and only Rh is present in the active site.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Virtual reality flight control display with six-degree-of-freedom controller and spherical orientation overlay

A virtual reality flight control system displays to the pilot the image of a scene surrounding a vehicle or pod having six degrees of freedom of acceleration or velocity control by the pilot and traveling through inertial space, the image itself including a superimposed figure providing the pilot an instant reference of orientation consisting of superimposed sets of geometric figures whose relative orientations provide the pilot an instantaneous feel or sense of orientation changes with respect to some fixed coordinate system. They include a first set of geometric figures whose orientations are fixed to the pilot's vehicle and a second set of geometric figures whose orientations are fixed with respect to a fixed or interstellar coordinate system. The first set of figures is a first set of orthogonal great circles about the three orthogonal axes of the flight vehicle or pod and centered at and surrounding the pilot's head, while the second set of figures is a second set of orthogonal great circles about the three orthogonal axes of a fixed or interstellar coordinate system, also centered at and surrounding the pilot's head.

Beckman, Brian C.↗

Compact, Controlled Resistance Exercise Device

Spaceflight leads to muscle and bone atrophy. Isoinertial (free-weight) exercises provide a sufficient stimulus to elicit increases in both muscle strength and bone mineral density in Earth-based studies. While exercise equipment is in use on the International Space Station for crewmember health maintenance, current devices are too large to place in a transport vehicle or small spacecraft. Therefore, a portable computer controlled resistance exercise device is being developed that is able to simulate the inertial loading experienced when lifting a mass on Earth. This portable device weighs less than 50 lb and can simulate the resistance of lifting and lowering up to 600 lb of free-weights. The objective is to allow crewmembers to perform resistance exercise with loads capable of maintaining muscle and bone health. The device is reconfigurable and allows for the performance of typical Earth-based free-weight exercises. Forces exerted, volume of work, range of motion, time-under-tension, and speed/ acceleration of movement are recorded and can be remotely monitored to track progress and modify individual protocols based on exercise session data. A performance evaluation will be completed and data will be presented that include ground-reaction force comparisons between the device and free-weight dead-lifts over a spectrum of resistance levels. Movement biomechanics will also be presented.

Paulus, David C.↗

NEXT Propellant Management System Integration With Multiple Ion Thrusters

As a critical part of the NEXT test validation process, a multiple-string integration test was performed on the NEXT propellant management system and ion thrusters. The objectives of this test were to verify that the PMS is capable of providing stable flow control to multiple thrusters operating over the NEXT system throttling range and to demonstrate to potential users that the NEXT PMS is ready for transition to flight. A test plan was developed for the sub-system integration test for verification of PMS and thruster system performance and functionality requirements. Propellant management system calibrations were checked during the single and multi-thruster testing. The low pressure assembly total flow rates to the thruster(s) were within 1.4 percent of the calibrated support equipment flow rates. The inlet pressures to the main, cathode, and neutralizer ports of Thruster PM1R were measured as the PMS operated in 1-thruster, 2-thruster, and 3-thruster configurations. It was found that the inlet pressures to Thruster PM1R for 2-thruster and 3-thruster operation as well as single thruster operation with the PMS compare very favorably indicating that flow rates to Thruster PM1R were similar in all cases. Characterizations of discharge losses, accelerator grid current, and neutralizer performance were performed as more operating thrusters were added to the PMS. There were no variations in these parameters as thrusters were throttled and single and multiple thruster operations were conducted. The propellant management system power consumption was at a fixed voltage to the DCIU and a fixed thermal throttle temperature of 75 C. The total power consumed by the PMS was 10.0, 17.9, and 25.2 W, respectively, for single, 2-thruster, and 3-thruster operation with the PMS. These sub-system integration tests of the PMS, the DCIU Simulator, and multiple thrusters addressed, in part, the NEXT PMS and propulsion system performance and functionality requirements.

Sovey, James S.↗

Control Modes of the ST7 Disturbance Reduction System Flight Validation Experiment

The Space Technology 7 experiment will perform an on-orbit system-level validation of two specific Disturbance Reduction System technologies: a gravitational reference sensor employing a free-floating test mass and a set of micro-Newton colloidal thrusters. The ST7 Disturbance Reduction System is designed to maintain the spacecraft s position with respect to a free-floating test mass to less than 10 nm/the square root of Hz over the frequency range of 1 to 30 mHz. This requirement will help ensure that the residual accelerations on the test masses (beyond gravitational acceleration) will be below the ST7 goal of 300 (1 + [f/3 mHz](sup 2)) pm/s(sup 2)/the square root of Hz. This paper presents the overall design and analysis of the spacecraft drag-free and attitude controllers being designed by NASA s Goddard Space Flight Center. These controllers close the loop between the GRS and the micro-Newton colloidal thrusters. The ST7 DRS comprises three control systems: the attitude control system to maintain a sun-pointing attitude, the drag free control to center the spacecraft about the test masses, and the test mass suspension control. There are five control modes in the operation of the ST7-DRS, starting from the attitude-only mode and leading to the challenging science mode. The design and analysis of each of the control modes are presented. An 18-DOF model is developed to capture the essential dynamics of the ST7-DRS package. It includes all rigid-body dynamics of the spacecraft and two test masses (three translations and three rotations for the spacecraft and each of the test masses). Actuation and measurement noise and major disturbance sources acting on the spacecraft and test masses are modeled.

Maghami, P. G.↗

Investigation of injury/illness data at a nuclear facility. Part II

At Los Alamos National Laboratory (LANL), there are several nuclear facilities, accelerator facilities, radiological facilities, explosives sites, moderate- and high-hazard non-nuclear facilities, biosciences laboratory, etc. The Plutonium Science and Manufacturing Directorate (ADPSM) provides special nuclear material research, process development, technology demonstration, and manufacturing capabilities. ADPSM manages the LANL Plutonium Facility. Within the Radiological Control Area at TA-55 (PF-4), chemical and metallurgical operations with plutonium and other hazardous materials are performed. LANL Health and Safety Programs investigate injury and illness data. In this study, statistically significant trends have been identified and compared for LANL, ADPSM, and PF-4 injury/illness cases. A previously described output metric is used to measures LANL management progress towards meeting its operational safety objectives and goals. Timelines are used to determine trends in Injury/Illness types. Pareto Charts are used to prioritize causal factors. The data generated from analysis of Injury/Illness data have helped identify and reduce the number of corresponding causal factors.

97 MATHEMATICS AND COMPUTING↗

Corrosion Dynamics of Carbon Steel in Small, Stagnant Volume under Radiation

The long term disposal of used nuclear fuel involves a deep geological repository (DGR) with the key barrier being the Used Fuel Container (UFC) consisting of a copper-coated carbon steel vessel. NWMO's Mark II design UFC is assembled by welding the semi-spherical head to a cylindrical body. Crevice is formed between the two parts along with the weld region. The objective of this research is to develop and validate a reliable corrosion model for long-term corrosion of CS under DGR condition. Water radiolysis produces chemically reactive species that affect corrosion rates and pathways. This work explores the synergistic effects of γ-radiation and solution properties on the dynamics of carbon steel corrosion. In Stage 1, corrosion rate is controlled by dissolution of iron to the solution phase. In Stage 2, the controlling processes are the growth of iron hydroxide gel. In Stage 3, the main iron redox reaction is the conversion between different iron oxides, and the overall corrosion rate is negligible. The concentration of Fe{sup 2+} (aq) near the metal surface reaches its solubility limit very quickly in a small, stagnant volume. Diffusion from crevice to bulk solution is more significant with larger crevice size. Porous, granular form of magnetite loosely attached to the metal surface is formed from Fe{sup 3+} in solution via reduction by H{sub 2}O{sub 2}. As a source of continuous formation of H{sub 2}O{sub 2}, radiation accelerates oxidation (Fe0 → Fe{sup 2+} → Fe{sup 3+}). Once the oxidation is almost complete, H{sub 2}O{sub 2} can act as a reducing reagent, reducing Fe{sup 3+} species back to Fe{sup 2+} forming more stable mixed Fe{sup 2+,3+} species (magnetite and maghemite)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ultra-High Vacuum Outgassing Characterization of Thermally Processed Low-Carbon Steel for Advanced Particle Accelerator and Gravitational Wave Detector Applications

This dissertation investigated AISI 1020 low-carbon steel as an alternative vacuum chamber material to conventional stainless steel for ultra-high vacuum (UHV) and extreme-high vacuum (XHV) applications. After a 400 °C/48 h bake, AISI 1020 tube chambers achieved a hydrogen outgassing rate of 2.4 × 10¿¹6 Torr·L·s¿¹·cm¿², approximately 2,300 times lower than the prebaked 316L stainless-steel comparator, among the lowest hydrogen outgassing rates ever reported for an uncoated metallic vacuum chamber. Bare and magnetite-coated AISI 1020 chambers were then compared using throughput and rate-of-rise methods. The magnetite coating yielded 5× lower water outgassing at room temperature, but this advantage disappeared after 80 °C baking. After full thermal conditioning (400 °C/48 h prebake followed by 150 °C/96 h and 200 °C/110 h), bare steel achieved 25× lower hydrogen outgassing than the magnetite-coated chamber (9.6 × 10¿¹6 Torr·L·s¿¹·cm¿²) and >99% H2 purity with carbon species below RGA detection. Monte Carlo molecular flow simulations of a CEBAF photogun beamline (96 scenarios) showed that replacing 304L stainless steel with AISI 1020 reduces equilibrium H2 pressure by a factor of 833; a single 304L electrode contributes 98.8% of the gas load despite occupying only 9.1% of the internal surface area. A 500-m Einstein Telescope beampipe screening showed that corrugated bellows contribute 18% of the gas load from only 0.7% of the surface area. A five-model adsorption isotherm framework applied to 22 pumpdown datasets (164 fits with AR(1)-GLS correction) established that the experimental protocol, not the material, controls isotherm identifiability: Dubinin–Radushkevich wins isothermal pipe pumpdowns; Langmuir wins thermally dominated chamber bakes. Cross-dataset joint fitting of the AISI 1020 pipe pumpdowns yielded an H2 diffusion activation energy Ed = 7.24 ± 1.28 kcal·mol¿¹, consistent with trap dominated diffusion in commercial low-carbon steels. Two companion innovations were developed: a Variable Conductance Device (VCD, patent pending IDF-00723) for XHV outgassing measurement, and VacuumDesignerPro (VDP), a MATLAB-based design tool validated against LIGO benchmarks.

Al-Allaq, Aiman H [Old Dominion University]↗

On the electrical conductivity of Ti-implanted alumina

Ion implantation of metal species into insulators provides a tool for the formation of thin, electrically conducting, surface layers with experimenter-controlled resistivity. High energy implantation of Pt and Ti into alumina accelerator components has been successfully employed to control high voltage surface breakdown in a number of cases. In the work described here we have carried out some basic investigations related to the origin of this phenomenon. By comparison of the results of alumina implanted with Ti at 75 keV with the results of prior investigations of polymers implanted with Pt at 49 eV and Au at 67 eV, we describe a physical model of the effect based on percolation theory and estimate the percolation parameters for the Ti-alumina composite. We estimate that the percolation dose threshold is about 4 x 10{sup 16} cm{sup -2} and the maximum dose for which the system remains an insulator-conductor composite is about 10 x 10{sup 16} cm{sup -2}. The saturation electrical conductivity is estimated to be about 50 S/m. We conclude that the observed electrical conductivity properties of Ti-implanted alumina can be satisfactorily described by percolation theory.

36 MATERIALS SCIENCE↗

Ion beam enhancement in magnetically insulated ion diodes for high-intensity pulsed ion beam generation in non-relativistic mode

High-intensity pulsed ion beam (HIPIB) with ion current density above Child-Langmuir limit is achieved by extracting ion beam from anode plasma of ion diodes with suppressing electron flow under magnetic field insulation. It was theoretically estimated that with increasing the magnetic field, a maximal value of ion current density may reach nearly 3 times that of Child-Langmuir limit in a non-relativistic mode and close to 6 times in a highly relativistic mode. In this study, the behavior of ion beam enhancement by magnetic insulation is systematically investigated in three types of magnetically insulated ion diodes (MIDs) with passive anode, taking into account the anode plasma generation process on the anode surface. A maximal enhancement factor higher than 6 over the Child-Langmuir limit can be obtained in the non-relativistic mode with accelerating voltage of 200–300 kV. The MIDs differ in two anode plasma formation mechanisms, i.e., surface flashover of a dielectric coating on the anode and explosive emission of electrons from the anode, as well as in two insulation modes of external-magnetic field and self-magnetic field with either non-closed or closed drift of electrons in the anode-cathode (A-K) gap, respectively. Combined with ion current density measurement, energy density characterization is employed to resolve the spatial distribution of energy density before focusing for exploring the ion beam generation process. Consistent results are obtained on three types of MIDs concerning control of neutralizing electron flows for the space charge of ions where the high ion beam enhancement is determined by effective electron neutralization in the A-K gap, while the HIPIB composition of different ion species downstream from the diode may be considerably affected by the ion beam neutralization during propagation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial Orientation and Balance Control Changes Induced by Altered Gravito-Inertial Force Vectors in Vestibular Deficient Patients

Eight chronic vestibular deficient (VD) patients (bilateral N = 4, unilateral N = 4, ages 18-67 were exposed to an interaural centripetal acceleration of 1 G (resultant 45 degree roll tilt of 1.4 G) on a 0.8 meter radius centrifuge for up to 90 minutes in the dark. The patients sat with head fixed upright, except every 4 of 10 minutes when instructed to point their nose and eyes towards a visual target (switched on every 3 to 5 seconds at random places within plus or minus 30 deg) in the Earth horizontal plane. Eye movements, including directed saccades for subjective Earth-and head-referenced planes, were recorded before, during, and after centrifugation using electro-oculography. Postural sway was measured before and within ten minutes after centrifugation using a sway-referenced or earth-fixed support surface, and with or without a head movement sequence. The protocol was selected for each patient based on the most challenging condition in which the patient was able to maintain balance with eyes closed.

Kaufman, Galen D.↗

A Radiation Laboratory Curriculum Development at Western Kentucky University

We present the latest developments for the radiation laboratory curriculum at the Department of Physics and Astronomy of Western Kentucky University. During the last decade, the Applied Physics Institute (API) at WKU accumulated various equipment for radiation experimentation. This includes various neutron sources (computer controlled d-t and d-d neutron generators, and isotopic 252 Cf and PuBe sources), the set of gamma sources with various intensities, gamma detectors with various energy resolutions (NaI, BGO, GSO, LaBr and HPGe) and the 2.5-MeV Van de Graaff particle accelerator. XRF and XRD apparatuses are also available for students and members at the API. This equipment is currently used in numerous scientific and teaching activities. Members of the API also developed a set of laboratory activities for undergraduate students taking classes from the physics curriculum (Nuclear Physics, Atomic Physics, and Radiation Biophysics). Our goal is to develop a set of radiation laboratories, which will strengthen the curriculum of physics, chemistry, geology, biology, and environmental science at WKU. The teaching and research activities are integrated into real-world projects and hands-on activities to engage students. The proposed experiments and their relevance to the modern status of physical science are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Results of Accelerated Stress Testing on Single-Channel and Multichannel Drivers: Solid-State Lighting Technology Area

This report is the first in a series of studies on accelerated stress testing (AST) of drivers used for SSL luminaires, such as downlights, troffers, and streetlights. A representative group of two-stage commercial driver products was exposed to an AST environment consisting of 75°C and 75% relative humidity (7575). These drivers were a mix of single-channel drivers (i.e., a single output current for one LED primary) and multichannel drivers (i.e., separate output currents for multiple LED primaries). This AST environment was chosen because previous testing on downlights with integrated drivers demonstrated that 38% of the sample population failed in less than 2,500 hours of testing using this method. In addition to AST test results, the performance of an SSL downlight product incorporating an integrated, multichannel driver during extended room temperature operational life (RTOL) testing is also reported. A battery of measurements was used to evaluate these products during accelerated testing, including full electrical characterization (i.e., power consumption, PF, total harmonic distortion [THD], and inrush current) and photometric characterization of external LED loads attached to the drivers (i.e., flicker performance and lumen maintenance).

24 POWER TRANSMISSION AND DISTRIBUTION↗