Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Approximating accelerator impedances with resonator networks

It is common in the accelerator community to use the impedance of accelerator components to describe wake interactions in the frequency domain. However, it is often desirable to understand such wake interactions in the time domain in a general manner for excitations that are not necessarily Gaussian in nature. Here, the conventional method for doing this involves taking the inverse Fourier Transform of the component impedance, obtaining the Green's Function, and then convolving it with the desired excitation distribution. This method can prove numerically cumbersome, for a convolution integral must be evaluated for each individual point in time when the wake function is desired. An alternative to this method would be to compute the wake function analytically, which would sidestep the need for repetitive integration. Only a handful of cases, however, are simple enough for this method to be tenable. One of these cases is the case where the component in question is an RLC resonator, which has a closed-form analytical wake function solution. This means that a component which can be represented in terms of resonators can leverage this solution. As it happens, common network synthesis techniques may be used to map arbitrary impedance profiles to RLC resonator networks in a manner the accelerator community has yet to take advantage of. In this work, we will use Foster Canonical Resonator Networks and partial derivative descent optimization to develop a technique for synthesizing resonator networks that well approximate the impedances of real-world accelerator components. We will link this synthesis to the closed-form resonator wake function solution, giving rise to a powerful workflow that may be used to streamline beam dynamics simulations.

43 PARTICLE ACCELERATORS↗

THREE-DIMENSIONAL NON-VACUUM PULSAR OUTER-GAP MODEL: LOCALIZED ACCELERATION ELECTRIC FIELD IN THE HIGHER ALTITUDES

We investigate the particle accelerator that arises in a rotating neutron-star magnetosphere. Simultaneously solving the Poisson equation for the electro-static potential, the Boltzmann equations for relativistic electrons and positrons, and the radiative transfer equation, we demonstrate that the electric field is substantially screened along the magnetic field lines by pairs that are created and separated within the accelerator. As a result, the magnetic-field-aligned electric field is localized in higher altitudes near the light cylinder and efficiently accelerates the positrons created in the lower altitudes outward but does not accelerate the electrons inward. The resulting photon flux becomes predominantly outward, leading to typical double-peak light curves, which are commonly observed from many high-energy pulsars.

79 ASTRONOMY AND ASTROPHYSICS↗

Harnessing the power of gradient-based simulations for multi-objective optimization in particle accelerators

Abstract Particle accelerator operation requires simultaneous optimization of multiple objectives. Multi-objective optimization (MOO) is particularly challenging due to trade-offs between the objectives. Evolutionary algorithms, such as genetic algorithms (GAs), have been leveraged for many optimization problems, however, they do not apply to complex control problems by design. This paper demonstrates the power of differentiability for solving MOO problems in particle accelerators using a deep differentiable reinforcement learning (DDRL) algorithm. We compare the DDRL algorithm with model-free reinforcement learning (MFRL), GA, and Bayesian optimization (BO) for simultaneous optimization of heat load and trip rates in the continuous electron beam accelerator facility. The underlying problem enforces strict constraints on both individual states and actions as well as cumulative (global) constraints on energy requirements of the beam. Using historical accelerator data, we develop a physics-based surrogate model which is differentiable and allows for back-propagation of gradients. The results are evaluated in the form of a Pareto-front with two objectives. We show that the DDRL outperforms MFRL, BO, and GA on high dimensional problems.

43 PARTICLE ACCELERATORS↗

Optimized matching conditions for self-guided laser wakefield accelerators

We revisit the matching conditions for self-guided laser pulse propagation in plasma and refine their formulation to maximize the energy of electrons produced via laser wakefield acceleration. Bayesian optimization, combined with particle-in-cell simulations carried out in a quasi-three-dimensional geometry and a Lorentz-boosted frame, is employed. The optimization identifies the maximum electron energy that a self-guided laser wakefield accelerator, driven by a laser of a given energy, can produce, together with the corresponding acceleration distance. Our results further demonstrate that electrons with energies close to the maximum value can be obtained across a relatively wide range of input parameters and without the need for their precise tuning. This provides substantial flexibility for experimental implementation and significantly relaxes the operational constraints associated with self-guided laser wakefield accelerators.

43 PARTICLE ACCELERATORS↗

Particle re-acceleration and Faraday-complex structures in the RXC J1314.4-2515 galaxy cluster

Radio relics are sites of electron (re)acceleration in merging galaxy clusters but the mechanism of acceleration and the topology of the magnetic field in and near relics are yet to be understood. We are carrying out an observational campaign on double relic galaxy clusters starting with RXC J1314.4–2515. With Jansky Very Large Array multiconfiguration observations in the frequency range 1–4 GHz, we perform both spectral and polarization analyses, using the rotation measure (RM) synthesis technique. We use archival XMM–Newton observations to constrain the properties of the shocked region. We discover a possible connection between the activity of a radio galaxy and the emission of the eastern radio relic. In the northern elongated arc of the western radio relic, we detect polarized emission with an average polarization fraction of 31 % at 3 GHz and we derive the Mach number of the underlying X-ray shock. Our observations reveal low levels of fractional polarization and Faraday-complex structures in the southern region of the relic, which point to the presence of thermal gas and filamentary magnetic field morphology inside the radio emitting volume. We measured largely different RM dispersion from the two relics. Finally, we use cosmological magnetohydrodynamical simulations to constrain the magnetic field, viewing angle, and to derive the acceleration efficiency of the shock. We find that the polarization properties of RXC J1314.4–2515 are consistent with a radio relic observed at 70° with respect to the line of sight and that the efficient re-acceleration of fossil electrons has taken place.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved laser-plasma accelerator stability via high-bandwidth longitudinal focal position stabilization of a 100 TW-class laser system

Laser-plasma accelerators (LPAs) offer an attractive alternative to conventional accelerators for the development of compact electron sources and next-generation light sources. Due to orders-of-magnitude larger accelerating gradients, LPAs enable the acceleration of high-brightness electron beams to ultrarelativistic energies in millimeter- to centimeter-scale distances. However, LPA stability is limited by shot-to-shot fluctuations of the driving laser system. Specifically, fluctuations in the final-focus longitudinal position result in correlated instability in LPA electron beam qualities, including total beam charge, average beam energy, and energy spread. We demonstrate active stabilization of the longitudinal focal position for a 100 TW-class laser system. This repetition-rate scalable stabilization system leverages noninvasive wave front monitoring of a copropagating, unamplified kHz pulse train to guide corrective adjustments to the focal position of a 1 Hz amplified drive laser via an upstream telescope on millisecond timescales. In this demonstration, the approach limits standard deviation fluctuations of the amplified drive beam’s longitudinal focal position to ±0.22⁢ mm (representing at least a 53% reduction), achieved with a correction bandwidth that reaches the Nyquist frequency limit. Consequently, we observe marked improvements in both long-term and shot-to-shot LPA stability in terms of charge and spectrum.

Beam control↗

Theoretical formulation of phase space microbunching instability in the presence of intrabeam scattering for single-pass or recirculation accelerators

Microbunching instability (MBI) has been one of the most challenging issues in designs of high-brightness beam transport lines for single-pass or recirculating accelerators. Although the intrabeam scattering (IBS) has long been studied in lepton or hadron storage rings as a slow diffusion process or in high-intensity proton linear accelerators as one mechanism for the beam halo, the effects of IBS on single-pass or recirculating electron accelerators have drawn attention only in the recent two decades due to emergence of linac-based or energy-recovery-linac-based fourth-generation light sources, which require high-quality electron beams during the beam transport. In this paper we develop a theoretical formulation of microbunching instability in the presence of IBS for single-pass or recirculation accelerators. To quantify MBI with inclusion of IBS, we start from the Vlasov-Fokker-Planck (VFP) equation, combining both collective interactions and incoherent IBS effects. The linearized VFP equation and the corresponding friction and diffusion coefficients are derived. The evolutions of the resultant density and energy modulations are formulated as a set of coupled integral equations. The theoretical formulation is then applied to a recirculating beamline design. The results from the semianalytical calculation are compared and show good agreement with massive particle tracking simulations.

43 PARTICLE ACCELERATORS↗

Nonresonant particle acceleration in strong turbulence: Comparison to kinetic and MHD simulations

Collisionless, magnetized turbulence offers a promising framework for the generation of nonthermal high-energy particles in various astrophysical sites. Yet, the detailed mechanism that governs particle acceleration has remained subject to debate. By means of 2D and 3D particle-in-cell, as well as 3D (incompressible) magnetohydrodynamic (MHD) simulations, we test here a recent model of nonresonant particle acceleration in strongly magnetized turbulence, which ascribes the energization of particles to their continuous interaction with the random velocity flow of the turbulence, in the spirit of the original Fermi model. To do so, we compare, for a large number of particles that were tracked in the simulations, the predicted and the observed histories of particles momenta. The predicted history is that derived from the model, after extracting from the simulations, at each point along the particle trajectory, the three force terms that control acceleration: the acceleration of the field line velocity projected along the field line direction, its shear projected along the same direction, and its transverse compressive part. Overall, we find a clear correlation between the model predictions and the numerical experiments, indicating that this nonresonant model can successfully account for the bulk of particle energization through Fermi-type processes in strongly magnetized turbulence. Additionally we also observe that the parallel shear contribution tends to dominate the physics of energization in the particle-in-cell simulations, while in the magnetohydrodynamic incompressible simulation, both the parallel shear and the transverse compressive term provide about equal contributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhancement of maximum attainable ion energy in the radiation pressure acceleration regime using a guiding structure

Radiation Pressure Acceleration is a highly efficient mechanism of laser driven ion acceleration, with the laser energy almost totally transferrable to the ions in the relativistic regime. There is a fundamental limit on the maximum attainable ion energy, which is determined by the group velocity of the laser. In the case of a tightly focused laser pulses, which are utilized to get the highest intensity, another factor limiting the maximum ion energy comes into play, the transverse expansion of the target. Transverse expansion makes the target transparent for radiation, thus reducing the effectiveness of acceleration. Utilization of an external guiding structure for the accelerating laser pulse may provide a way of compensating for the group velocity and transverse expansion effects.

43 PARTICLE ACCELERATORS↗

The Natural and Accelerated Evolution of EVA Adhesion Through Intermediate Exposures

Ethylene vinyl acetate (EVA) encapsulants comprise the majority of the encapsulants currently in use; much work has been done to understand and model the adhesive characteristics of EVA-encapsulated modules, but limited work has provided reliable insight into adhesion during the intermediate stages of exposure, limiting the ability to validate model predictions in this range. We provide the adhesion energy measurements for EVA adhesion after nearly six years of field aging and 10 000 h of accelerated aging. Both field and accelerated aging reveal a distinct plateau that emerges during the intermediate exposure periods (after one year in the field and after 1000 h in a chamber). At 10 000 h, adhesion within accelerated aged minimodules falls to a level generally seen after long-term field exposures (>15 years). Previous modeling predicted that adhesion would steadily decrease over the lifetime of a module, but these current results uncover an intermediate plateauing trend that is important to accurately modeling the evolution of adhesion and predicting adhesive failure. Based on these findings, three key model refinements concerning the rate of UV-radical formation and subsequent β-scission, the rate and acceleration of hydrolytic depolymerization, and the profile of the plasticity contribution over time are implemented and discussed.

14 SOLAR ENERGY↗

Adapting In Situ Accelerators for Sparsity With Granular Matrix Reordering

Neural network (NN) inference is an essential part of modern systems and is found at the heart of numerous applications ranging from image recognition to natural language processing. In situ NN accelerators can efficiently perform NN inference using resistive crossbars, which makes them a promising solution to the data movement challenges faced by conventional architectures. Although such accelerators demonstrate significant potential for dense NNs, they often do not benefit from sparse NNs, which contain relatively few non-zero weights. Processing sparse NNs on in situ accelerators results in wasted energy to charge the entire crossbar where most elements are zeros. To address this limitation, this paper proposes Granular Matrix Reordering (GMR): a preprocessing technique that enables an energy-efficient computation of sparse NNs on in situ accelerators. GMR reorders the rows and columns of sparse weight matrices to maximize the crossbars' utilization and minimize the total number of crossbars needed to be charged. The reordering process does not rely on sparsity patterns and incurs no accuracy loss. Finally, GMR achieves an average of 28% and up to 34% reduction in energy consumption over seven pruned NNs across four different pruning methods and network architectures.

97 MATHEMATICS AND COMPUTING↗

SU-C-17A-07: The Development of An MR Accelerator-Enabled Planning-To-Delivery Technique for Stereotactic Palliative Radiotherapy Treatment of Spinal Metastases

Purpose: To develop an MR accelerator-enabled online planning-todelivery technique for stereotactic palliative radiotherapy treatment of spinal metastases. The technical challenges include; automated stereotactic treatment planning, online MR-based dose calculation and MR guidance during treatment. Methods: Using the CT data of 20 patients previously treated at our institution, a class solution for automated treatment planning for spinal bone metastases was created. For accurate dose simulation right before treatment, we fused geometrically correct online MR data with pretreatment CT data of the target volume (TV). For target tracking during treatment, a dynamic T2-weighted TSE MR sequence was developed. An in house developed GPU based IMRT optimization and dose calculation algorithm was used for fast treatment planning and simulation. An automatically generated treatment plan developed with this treatment planning system was irradiated on a clinical 6 MV linear accelerator and evaluated using a Delta4 dosimeter. Results: The automated treatment planning method yielded clinically viable plans for all patients. The MR-CT fusion based dose calculation accuracy was within 2% as compared to calculations performed with original CT data. The dynamic T2-weighted TSE MR Sequence was able to provide an update of the anatomical location of the TV every 10 seconds. Dose calculation and optimization of the automatically generated treatment plans using only one GPU took on average 8 minutes. The Delta4 measurement of the irradiated plan agreed with the dose calculation with a 3%/3mm gamma pass rate of 86.4%. Conclusions: The development of an MR accelerator-enabled planning-todelivery technique for stereotactic palliative radiotherapy treatment of spinal metastases was presented. Future work will involve developing an intrafraction motion adaptation strategy, MR-only dose calculation, radiotherapy quality-assurance in a magnetic field, and streamlining the entire treatment process on an MR accelerator.

60 APPLIED LIFE SCIENCES↗

SU-E-T-384: Experimental Verification of a Monte Carlo Linear Accelerator Model Using a Radiochromic Film Stack Dosimeter

Purpose: To experimentally verify a Monte Carlo (MC) linear accelerator model for the simulation of intensity-modulated radiation therapy (IMRT) treatments of moving targets. Methods: A Varian Clinac™ 21EX linear accelerator was modeled using the EGSnrc user code BEAMnrc. The mean energy, radial-intensity distribution, and divergence of the electron beam incident on the bremsstrahlung target were adjusted to achieve agreement between simulated and measured percentage-depth-dose and transverse field profiles for a 6 MV beam. A seven-field step-and-shoot IMRT lung procedure was prepared using Varian Eclipse™ treatment planning software. The plan was delivered using a Clinac™ 21EX linear accelerator and measured with a Gafchromic™ EBT2 film stack dosimeter (FSD) in two separate static geometries: within a cylindrical water-equivalent-plastic phantom and within an anthropomorphic chest phantom. Two measurements were completed in each setup. The dose distribution for each geometry was simulated using the EGSnrc user code DOSXYZnrc. MC geometries of the treatment couch, cylindrical phantom, and chest phantom were developed by thresholding CT data sets using MATLAB™. The FSD was modeled as water. The measured and simulated dose distributions were normalized to the median dose within the FSD. Results: Using an electron beam with a mean energy of 6.05 MeV, a Gaussian radial-intensity distribution with a full width at half maximum of 1.5 mm, and a divergence of 0°, the measured and simulated dose profiles agree within 1.75% and 1 mm. Measured and simulated dose distributions within both the cylindrical and chest phantoms agree within 3% over 94% of the FSD volume. The overall uncertainty in the FSD measurements is 3.1% (k=1). Conclusion: MC simulations agree with FSD measurements within measurement uncertainty, thereby verifying the accuracy of the linear accelerator model for the simulation of IMRT treatments of static geometries. The experimental verification will be extended to treatments of targets undergoing three-dimensional motion.

60 APPLIED LIFE SCIENCES↗

SU-F-E-06: Dosimetric Characterization of Small Photons Beams of a Novel Linear Accelerator

Purpose: The aim of the present contribution was to measure the main dosimetric quantities of small fields produced by UNIQUE and evaluate its matching with the corresponding dosimetric data of one 21EX conventional linear accelerator (Varian) in operation at the same center. The second step was to evaluate comparative performance of the EDGE diode detector and the PinPoint micro-ionization chamber for dosimetry of small fields. Methods: UNIQUE is configured with MLC (120 leaves with 0.5 cm leaf width) and a single low photon energy of 6 MV. Beam data were measured with scanning EDGE diode detector (volume of 0.019 mm{sup 3}), a PinPoint micro-ionization chamber (PTW) and for larger fields (≥ 4×4cm{sup 2}) a PTW Semi flex chamber (0.125 cm{sup 3}) was used. The scanning system used was the 3D cylindrical tank manufactured by Sun Nuclear, Inc. The measurement of PDD and profiles were done at 100 cm SSD and 1.5 depth; the relative output factors were measured at 10 cm depth. Results: PDD and the profile data showed less than 1% variation between the two linear accelerators for fields size between 2×2 cm{sup 2} and 5×5cm{sup 2}. Output factor differences was less than 1% for field sizes between 3×3 cm{sup 2} and 10×10 cm{sup 2} and less of 1.5 % for fields of 1.5×1.5 cm{sup 2} and 2×2 cm{sup 2} respectively. The dmax value of the EDGE diode detector, measured from the PDD, was 8.347 mm for 0.5×0,5cm{sup 2} for UNIQUE. The performance of EDGE diode detector was comparable for all measurements in small fields. Conclusion: UNIQUE linear accelerator show similar dosimetrics characteristics as conventional 21EX Varian linear accelerator for small, medium and large field sizes.EDGE detector show good performance by measuring dosimetrics quantities in small fields typically used in IMRT and radiosurgery treatments.

60 APPLIED LIFE SCIENCES↗

SU-F-T-475: An Evaluation of the Overlap Between the Acceptance Testing and Commissioning Processes for Conventional Medical Linear Accelerators

Purpose: This work’s objective is to determine the overlap of processes, in terms of sub-processes and time, between acceptance testing and commissioning of a conventional medical linear accelerator and to evaluate the time saved by consolidating the two processes. Method: A process map for acceptance testing for medical linear accelerators was created from vendor documentation (Varian and Elekta). Using AAPM TG-106 and inhouse commissioning procedures, a process map was created for commissioning of said accelerators. The time to complete each sub-process in each process map was evaluated. Redundancies in the processes were found and the time spent on each were calculated. Results: Mechanical testing significantly overlaps between the two processes - redundant work here amounts to 9.5 hours. Many beam non-scanning dosimetry tests overlap resulting in another 6 hours of overlap. Beam scanning overlaps somewhat - acceptance tests include evaluating PDDs and multiple profiles but for only one field size while commissioning beam scanning includes multiple field sizes and depths of profiles. This overlap results in another 6 hours of rework. Absolute dosimetry, field outputs, and end to end tests are not done at all in acceptance testing. Finally, all imaging tests done in acceptance are repeated in commissioning, resulting in about 8 hours of rework. The total time overlap between the two processes is about 30 hours. Conclusion: The process mapping done in this study shows that there are no tests done in acceptance testing that are not also recommended to do for commissioning. This results in about 30 hours of redundant work when preparing a conventional linear accelerator for clinical use. Considering these findings in the context of the 5000 linacs in the United states, consolidating acceptance testing and commissioning would have allowed for the treatment of an additional 25000 patients using no additional resources.

60 APPLIED LIFE SCIENCES↗

SU-F-T-577: Comparison of Small Field Dosimetry Measurements in Fields Shaped with Conical Applicators On Two Different Accelerating Systems

Purpose: To investigate small field dosimetry measurements and associated uncertainties when conical applicators are used to shape treatment fields from two different accelerating systems. Methods: Output factor measurements are made in water in beams from the CyberKnife radiosurgery system, which uses conical applicators to shape fields from a (flattening filter-free) 6 MV beam, and in a 6 MV beam from the Elekta Precise linear accelerator (with flattening filter) with BrainLab external conical applicators fitted to shape the field. The measurements use various detectors: (i) an Exradin A16 ion chamber, (ii) two Exradin W1 plastic scintillation detectors, (iii) a Sun Nuclear Edge diode, and (iv) two PTW microDiamond synthetic diamond detectors. Profiles are used for accurate detector positioning and to specify field size (FWHM). Output factor measurements are corrected with detector specific correction factors taken from the literature where available and/or from Monte Carlo simulations using the EGSnrc code system. Results: Differences in measurements of up to 1.7% are observed with a given detector type in the same beam (i.e., intra-detector variability). Corrected results from different detectors in the same beam (inter-detector differences) show deviations up to 3 %. Combining data for all detectors and comparing results from the two accelerators results in a 5.9% maximum difference for the smallest field sizes (FWHM=5.2–5.6 mm), well outside the combined uncertainties (∼1% for the smallest beams) and/or differences among detectors. This suggests that the FWHM of a measured profile is not a good specifier to compare results from different small fields with the same nominal energy. Conclusion: Large differences in results for both intra-detector variability and inter-detector differences suggest potentially high uncertainties in detector-specific correction factors. Differences between the results measured in circular fields from different accelerating systems provide insight into sources of variability in small field dosimetric measurements reported in the literature.

07 ISOTOPE AND RADIATION SOURCES↗

The crystal acceleration effect for cold neutrons

A new mechanism of neutron acceleration is discussed and studied experimentally in detail for cold neutrons passing through the accelerated perfect crystal with the energies close to the Bragg one. The effect arises due to the following reason. The crystal refraction index (neutron-crystal interaction potential) for neutron in the vicinity of the Bragg resonance sharply depends on the parameter of deviation from the exact Bragg condition, i.e. on the crystal-neutron relative velocity. Therefore the neutrons enter into accelerated crystal with one neutron-crystal interaction potential and exit with the other. Neutron kinetic energy cannot vary inside the crystal due to its homogeneity. So after passage through such a crystal neutrons will be accelerated or decelerated because of the different energy change at the entrance and exit crystal boundaries.

74 ATOMIC AND MOLECULAR PHYSICS↗

Accelerator based epithermal neutron source

We review the current status of the development of accelerator sources of epithermal neutrons for boron neutron capture therapy (BNCT), a promising method of malignant tumor treatment. Particular attention is given to the source of epithermal neutrons on the basis of a new type of charged particle accelerator: tandem accelerator with vacuum insulation and lithium neutron-producing target. It is also shown that the accelerator with specialized targets makes it possible to generate fast and monoenergetic neutrons, resonance and monoenergetic gamma-rays, alpha-particles, and positrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗