A Case Study of Danville Utilities:
This case study provides information on how Danville Utilities utilized ITP Industrial Assessment Centers to provide energy efficiency resources to key accounts.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This case study provides information on how Danville Utilities utilized ITP Industrial Assessment Centers to provide energy efficiency resources to key accounts.
The MSV Java Utility Library contains software developed over many years for many sponsors. (This work is not a derivative of CB-EMIS), but rather support to the CB-EMIS software). Projects that have used and contributed to code in this library: CB-EMIS (PROTECT), BWIC, Fort Future, Teva, Integrated Oceans, ENKIMDU, RCW, JEMS, JWACS, EPA watershed, and many others. This library will continue to be used in other non-CB-EMIS related projects. The components include: Spatial components: Multi-coordinate system spatial objects. 2D spatial indexing system, and polygon griding system. Data translation: Allows import and export of file based data to and from object oriented systems. Multi-platform data streams: Allows platform specific data streams to operate on any support platform. Other items include printing, custom GUI components, support for NIMA Raster Product Format, program logging utilities and others.
This program optimizes the alignment of each reflector panel (mirror), on a parabolic trough solar collector array (SCA) to maximize the amount of solar energy intercepted by the solar receiver. This program analyzes data acquired by the TOPDAQ Acquisition Utility program. For each module on an SCA, the program compares the location of the image of the receiver in the reflector panels with its theoretical location. Based on the difference between the theoretical and actual image locations, reflector panel misalignment and corrective mirror mount adjustments are determined. Using the information in the digital images and other data acquired from the TOPDAQ Acquisition Utility, the program is able to determine the relative positions of the camera fixture between modules and align all of the mirrors on an SCA to the receiver. This program currently optimizes the alignment of a Reflector Panel (RP) 2 or RP 3 trough module only.
TriUtils is a package of utilities for other Trilinos packages. TriUtils contains utilities to perform common operations such as command line parsing, and input file reading.
The potential to store energy within refrigerated food products presents convenience store and supermarket operators with an opportunity to participate in utility sponsored demand response programs, whereby electricity usage can be shifted or reduced during peak periods. To determine the feasibility of reducing peak demand by shifting the refrigeration load to off-peak times, experimental and analytical analyses were performed. Simulated product, consisting of one-pint containers filled with a 50% ethylene glycol and 50% water solution, were stored in a medium-temperature vertical open refrigerated display case. Product temperature rise as a function of time was determined by turning off the refrigeration to the display case, while product temperature pull-down time was subsequently determined by turning on the refrigeration to the display case. It was found that the thermal mass of the product in a medium-temperature display case was such that during a 2.5 hour period with no refrigeration, the average product temperature increased by 5.5 C. In addition, it took approximately 3.5 hours for the product to recover to its initial temperature after the refrigeration was turned on. Transient heat conduction analyses for one-dimensional objects is in good agreement with the experimental results obtained in this study. From the analysis, it appears that the thermal mass of the stored product in refrigerated display cases is sufficient to allow product temperatures to safely drift for a significant time under reduced refrigeration system operation. Thus, strategies for shifting refrigeration system electrical demand can be developed. The use of an advanced refrigeration system controller that can respond to utility signals can enable demand shifting with minimal impact.
This is a utility library to support umbra core. These utilities are widely disparate in capability, but largely serve to extend the core Umbra. This is a catch-all library for useful modules such as positioning modules, logic and statistical distribution modules and other general purpose classes and modules.
An apparatus for materials processing utilizing a rotating magnetic field comprises a platform for supporting a specimen, and a plurality of magnets underlying the platform. The plurality of magnets are configured for rotation about an axis of rotation intersecting the platform. A heat source is disposed above the platform for heating the specimen during the rotation of the plurality of magnets. A method for materials processing utilizing a rotating magnetic field comprises providing a specimen on a platform overlying a plurality of magnets; rotating the plurality of magnets about an axis of rotation intersecting the platform, thereby applying a rotating magnetic field to the specimen; and, while rotating the plurality of magnets, heating the specimen to a desired temperature.
This paper explores a real security vulnerability and patch management dataset from an electric utility in order to shed light on characteristics of the vulnerabilities that electric utility assets have and how they are remediated in practice. Specifically, it first analyzes the distribution of vulnerabilities over software, assets, and other metric. Then it analyzes how vulnerability features affect remediate actions.
Buildings in China, India, the United States (US), and United Kingdom (UK) consume 39-45% of each nation's primary energy with fast-growing countries like India projected to use 76% of their primary energy by 2040. In the United States, 73% of all electricity is consumed by buildings. In an effort to better operate electrical grids, needs exist to generate improved load models by better understanding and quantifying weather impacts and microclimate effects on building-specific energy use throughout a city.Scalable methods have been created to allow urban-scale energy modeling – to identify and synthesize a fully-articulated building energy model for every building in an area of interest. This was applied to the 1,385 km2 utility district serviced by the Electric Power Board of Chattanooga, TN. Each building is simulated on the world’s 4th-fastest supercomputer, Titan, using the U.S. Dept. of Energy’s flagship whole-building simulation tool, EnergyPlus, to analyze relationships among climatic conditions, urban morphology, land cover, and energy use. The Weather Research Forecast (WRF) model was scaled on several High Performance Computing (HPC) resources to simulate microclimate variation under different urban morphologies. We analyze the differences between WRF-based microclimate simulations and measured weather station data. This information is then used to quantify impact of microclimate variation and variable-specific meteorological variables on the electrical consumption for individual buildings and show impacts at the scale of a utility district.
We abstract the accuracy performance of any fuser into a fusion quality measure that is within the range [0; 1] and monotonically decreases with increasing errors. Although there are many possible ways to map the actual error to this quality measure, we adopt a mapping function consisting of both concave and convex regions and its parameters can be tuned based on system design requirements. The effect of communication loss over the links from the sensors, where estimates are generated, to the fuser is then considered, and based on the variations of the quality measure with loss, we define the overall fuser utility that characterizes the resilience of a fuser with increasingly adverse communication constraints. Tracking examples are shown to demonstrate the comparative quality and utility performances of several closed-form fusers.
Wide-area data transfers in high-performance computing infrastructures and big data applications are increasingly carried over dynamically provisioned dedicated network connections, which provide high capacities with no competing traffic. Throughput of TCP and UDT over wide-area connections depends, often in a complex non-linear way, on the congestion control mechanism, buffer sizes, and the number of parallel streams. In addition, our extensive TCP and UDT throughput measurements and time traces over a suite of physical and emulated 10 Gbps connections with 0-366 ms round-trip times (RTTs) show significant statistical and temporal variations. Consequently, parameter selection and optimization for transport methods require data analytics to complement analytical throughput models. We present analytics based on the concavity-convexity of throughput profiles which provide insights into peak throughput and superior/inferior trend compared to linear interpolations based on RTT. In particular, we propose the utilization-concavity coefficient, a scalar metric that incorporates both utilization and concavity profile to characterize the overall performance of a transport protocol. These measurements-based anaytics enable us to select a transport protocol and its parameters for a given host and connection configuration to achieve high throughput with statistical guarantees.
The PIDOTS radiation transport code implements a spatially decomposed Integral Transport Matrix Method (ITMM) solver, which is intended to fully utilize the capabilities of modern, massively parallel high-performance computing (HPC) systems. While the code shows promising results, there was also an unexpected loss of parallel efficiency on the test systems as the number of participating processors grew and the parallelization grain size got finer. We seek to identify and characterize the communication-latency based effects that contribute to this slowdown. Through the creation of a high-level, parameterized representation of the workload of the code, the communication methodology was identified as the likely reason. From there, low-level, InfiniBand communication performance data measured on the Falcon HPC at Idaho National Laboratory (INL) was used to produce a discrete-event model of the communication scheme. The data, as well as the model, show that infrequent, large spikes in send/receive latency drive an unexpectedly substantial increase in projected runtime of a code. Furthermore, these effects are more pronounced under the high-utilization, scattered-workload environment of Falcon. Based on results from the model, it can be shown that a high-communication volume, small message-size regime can easily lead to slowdowns of ~5-10x, when compared to ideal results, as the processor count increases.
An ionic liquid desiccant system utilizes an ionic liquid desiccant to draw moisture from a working fluid, such as air that flow into an enclosure, such as a home. The desiccant may be mixed with the working fluid or a separator that allows moisture transport therethrough may be configured between the ionic liquid desiccant and the working fluid. The ionic liquid desiccant system may be part of an air conditioning system and may remove the moisture from air that is cooled by flowing over an evaporator or heat exchanger coupled with the evaporator. The ionic liquid desiccant may be pumped from a desiccant chamber to a regenerator chamber to remove absorbed moisture. A dual-purpose chamber may act as a desiccant chamber and as a regenerator chamber. A refrigeration system may have an electrochemical compressor and may utilize metal hydride heat exchangers.
This work was presented at the American Center for Life Cycle Assessment 2019 Conference (LCAXIX) in Tucson, AZ on September 25, 2019. Capturing carbon dioxide (CO2) emissions from power and industrial sources and using that CO2 to make useful products is an emerging area of research that will benefit from a consistent and unbiassed framework like life cycle assessment/analysis (LCA) to understand the environmental impacts and net life cycle GHG reductions compared to the current state of the alternative in the marketplace. In the interest of supporting the creation of useful and consistent LCAs of CO2 utilization projects, the DOE National Energy Technology Laboratory has developed a CO2 utilization LCA toolkit. The primary audience for the toolkit is the group of principal investigators that have been awarded a grant through a DOE Carbon Use and Reuse funding opportunity announcement. However, we believe that there is potential wider application beyond those grant recipients.
Drones equipped with video cameras, LIDAR and thermal imagers have been demonstrated in industrial and utility settings. In such instances, the images are typically locally stored onboard the drone then retrieved from the image storage media and analyzed. We report on a project involving the transport and display of measurements and thermal and visual video streams into a utility control center. Relying on an integrated multimedia communications network, realtime control center viewing of sensor readings and image streams is achieved. Details of this activity are reported.
To enable better voltage regulation in power systems with high penetration of photovoltaics (PV) and other distributed energy resources (DERs), future inverters are required to provide reactive power support to the grid in addition to providing real power generated by PV panels. This paper develops a framework that coordinates the support from DER-based inverters, which are grid-connected non-utility assets, by using a transactive energy approach. Results of the implementation demonstrate participation of DER-based inverters can be achieved by using the coordination between distributed controllers and a centralized controller. With the transactive energy approach, both the customer and utility can achieve benefits that meet their individual needs.
PNNL cybersecurity experts developed two novel cyber tools to help utilities and organizations that serve them combat malicious cyber attacks. The first is the Cybersecurity Framework Tool, or CFT. This patented tool provides a way for utilities and their associated vendors to identify, protect, detect, respond to, and recover from emerging cyber threats or vulnerabilities to critical infrastructure. CFT provides an easy-to-follow set of best practices, policies, and procedures to improve the cybersecurity postures of critical infrastructure. The second tool is the Cybersecurity Training Game Simulator, a dynamic “train the trainer” tool. The game provides interactive training scenarios based on major cyberattacks that happened in the U.S. during the past decade. Both innovations are available for commercialization. Contact Commercialization Manager Peter Christensen at peter.christensen@pnnl.gov to learn more.
The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS—based on real-time optimal power flow—controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.