Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Method and Apparatus for In-Situ Health Monitoring of Solar Cells in Space

Embodiments of the present invention describe an apparatus including an oscillator, a ramp generator, and an inverter. The oscillator is configured to generate a waveform comprising a low time and a high time. The inverter is configured to receive the waveform generated by the oscillator, and invert the waveform. The ramp generator is configured to increase a gate control voltage of a transistor connected to a solar cell, and rapidly decrease the gate control voltage of the transistor. During the low time, a measurement of a current and a voltage of the solar cell is performed. During the high time, a measurement of a current of a shorted cell and a voltage reference is performed.

Krasowski, Michael J.↗

Tension experiments on diaphragm metals

Strips of german silver, steel, copper, duralumin, nickel and brass were tested in tension in an apparatus in which the change in deflection with time was measured by means of an interferometer. This change in deflection with time caused by the application and removal of a load is defined as "drift" and "recovery," respectively. It was measured in the time interval from approximately 5 seconds to 5 hours after loading. The data are given in a series of graphs in which the drift and recovery are plotted against time. The proportional drift and recovery in five hours are given for a number of the tests, and in addition are shown graphically for nickel and steel.

Henrickson, H B↗

Edge magnetoplasmon dispersion and time-resolved plasmon transport in a quantum anomalous Hall insulator

A quantum anomalous Hall (QAH) insulator breaks reciprocity by combining magnetic polarization and spin-orbit coupling to generate a unidirectional transmission of signals in the absence of an external magnetic field. Such behavior makes QAH materials a good platform for the innovation of circulator technologies. However, it remains elusive as to how the wavelength of the chiral edge plasmon relates to its frequency and how the plasmon wave packet is excited in the time domain in a QAH insulator. Here, we investigate the edge magnetoplasmon (EMP) resonances in Cr-(Bi,Sb) 2 Te 3 by frequency and time domain measurements. From disk shaped samples with various dimensions, we obtain the dispersion relation of EMPs and extract the drift velocity of the chiral edge state. From the time-resolved transport measurements, we identify the velocity of the plasmon wave packet and observe a transition from the edge to bulk transport at an elevated temperature. We show that the frequency and time domain measurements are well modeled by loss from the microwave induced dissipative channels in the bulk area. Our results demonstrate that the EMP decay rate can be significantly reduced by applying a low microwave power and fabricating devices of larger diameter ≥ 100 µ m . In a R = 125 µ m sample, a nonreciprocity of 20 dB has been realized at 1.3 GHz, shining light on using QAH insulators to develop on-chip nonreciprocal devices. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Methods and apparatus for determining cardiac output

The present invention provides methods and apparatus for determining a dynamical property of the systemic or pulmonary arterial tree using long time scale information, i.e., information obtained from measurements over time scales greater than a single cardiac cycle. In one aspect, the invention provides a method and apparatus for monitoring cardiac output (CO) from a single blood pressure signal measurement obtained at any site in the systemic or pulmonary arterial tree or from any related measurement including, for example, fingertip photoplethysmography.According to the method the time constant of the arterial tree, defined to be the product of the total peripheral resistance (TPR) and the nearly constant arterial compliance, is determined by analyzing the long time scale variations (greater than a single cardiac cycle) in any of these blood pressure signals. Then, according to Ohm's law, a value proportional to CO may be determined from the ratio of the blood pressure signal to the estimated time constant. The proportional CO values derived from this method may be calibrated to absolute CO, if desired, with a single, absolute measure of CO (e.g., thermodilution). The present invention may be applied to invasive radial arterial blood pressure or pulmonary arterial blood pressure signals which are routinely measured in intensive care units and surgical suites or to noninvasively measured peripheral arterial blood pressure signals or related noninvasively measured signals in order to facilitate the clinical monitoring of CO as well as TPR.

Cohen, Richard J.↗

Capability of Impedance Measurement Using Spread Spectrum Time-Domain Reflectometry

Spread spectrum time-domain reflectometry (SSTDR) has been proposed for measuring electrical impedance on live, energized systems, in electrically noisy environments, or for measuring multiple channels simultaneously. Here we evaluate the capability of SSTDR for impedance measurement from near dc to 96 MHz and find that they agree very well with measurements from a vector network analyzer (VNA). Time gating is used to remove (calibrate out) transmission line effects. We evaluate the frequency ranges over which SSTDR at different modulation frequencies is accurate for the measurement of series resistive–capacitive ( RC ) loads and observe that fusing measurements from multiple modulation frequencies can broaden the effective measurement bandwidth.

14 SOLAR ENERGY↗

Effects of High Fuel Loading and CO2 Dilution on Oxy-Methane Ignition Inside a Shock Tube at High Pressure

Abstract Ignition delay times were measured for methane/O2 mixtures in a high dilution environment of either CO2 or N2 using a shock tube facility. Experiments were performed between 1044 K and 1356 K at pressures near 16 ± 2 atm. Test mixtures had an equivalence ratio of 1.0 with 16.67% CH4, 33.33% O2, and 50% diluent. Ignition delay times were measured using OH* emission and pressure time-histories. Data were compared to the predictions of two literature kinetic mechanisms (ARAMCO MECH 2.0 and GRI Mech 3.0). Most experiments showed inhomogeneous (mild) ignition which was deduced from five time-of-arrival pressure transducers placed along the driven section of the shock tube. Further analysis included determination of blast wave velocities and locations away from the end wall of initial detonations. Blast velocities were 60–80% of CJ-Detonation calculations. A narrow high temperature region within the range was identified as showing homogenous (strong) ignition which showed generally good agreement with model predictions. Model comparisons with mild ignition cases should not be used to further refine kinetic mechanisms, though at these conditions, insight was gained into various ignition behavior. To the best of our knowledge, we present first shock tube data during ignition of high fuel loading CH4/O2 mixtures diluted with CO2 and N2.

Energy & Fuels↗

Pulsed Airborne Lidar Measurements of C02 Column Absorption

We report on airborne lidar measurements of atmospheric CO2 column density for an approach being developed as a candidate for NASA's ASCENDS mission. It uses a pulsed dual-wavelength lidar measurement based on the integrated path differential absorption (IPDA) technique. We demonstrated the approach using the CO2 measurement from aircraft in July and August 2009 over four locations. The results show clear CO2 line shape and absorption signals, which follow the expected changes with aircraft altitude from 3 to 13 km. The 2009 measurements have been analyzed in detail and the results show approx.1 ppm random errors for 8-10 km altitudes and approx.30 sec averaging times. Airborne measurements were also made in 2010 with stronger signals and initial analysis shows approx. 0.3 ppm random errors for 80 sec averaging times for measurements at altitudes> 6 km.

Abshire, James B.↗

Satellite (Timed, Aura, Aqua) and In Situ (Meteorological Rockets, Balloons) Measurement Comparability

Measurements using the inflatable falling sphere often are requested to provide density data in support of special sounding rocket launchings into the mesosphere and thermosphere. To insure density measurements within narrow time frames and close in space, the inflatable falling sphere is launched within minutes of the major test. Sphere measurements are reliable for the most part, however, availability of these rocket systems has become more difficult and, in fact, these instruments no longer are manufactured resulting in a reduction of the meager stockpile of instruments. Sphere measurements also are used to validate remotely measured temperatures and have the advantage of measuring small-scale atmospheric features. Even so, with the dearth of remaining falling spheres perhaps it is time to consider whether the remote measurements are mature enough to stand alone. Presented are two field studies, one in 2003 from Northern Sweden and one in 2010 from the vicinity of Kwajalein Atoll that compare temperature retrievals between satellite and in situ failing spheres. The major satellite instruments employed are SABER, MLS, and AIRS. The comparisons indicate that remotely measured temperatures mimic the sphere temperature measurements quite well. The data also confirm that satellite retrievals, while not always at the exact location required for individual studies, are adaptable enough and highly useful. Although the falling sphere will provide a measurement at a specific location and time, satellites only pass a given location daily or less often. This report reveals that averaged satellite measurements can provide temperatures and densities comparable to the falling sphere.

Schmidlin, F. J.↗

Mean-flow measurements of the flow field diffusing bend

Time-average measurements of the low-speed turbulent flow in a diffusing bend are presented. The experimental geometry consists of parallel top and bottom walls and curved diverging side walls. The turning of the center line of this channel is 40 deg, the area ratio is 1.5 and the ratios of height and center-line length to throat width are 1.5 and 3, respectively. The diffusing bend is preceded and followed by straight constant area sections. The inlet boundary layers on the parallel walls are artificially thickened and occupy about 30% of the channel height; those on the side walls develop naturally and are about half as thick. The free-stream speed at the inlet was approximately 30 m/sec for all the measurements. Inlet boundary layer mean velocity and turbulence intensity profiles are presented, as are data for wall static pressures, and at six cross sections, surveys of the velocity-vector and static-pressure fields. The dominant feature of the flow field is a pair of counter-rotating streamwise vortices formed by the cross-stream pressure gradient in the bend on which an overall deceleration is superimposed.

Mcmillan, O. J.↗

Discrete-time infinity control problem with measurement feedback

The paper is concerned with the discrete-time H(sub infinity) control problem with measurement feedback. The authors extend previous results by having weaker assumptions on the system parameters. The authors also show explicitly the structure of H(sub infinity) controllers. Finally, they show that it is in certain cases possible, without loss of performance, to reduce the dynamical order of the controllers.

Stoorvogel, A. A.↗

Two-stage gas measurement system

A quick-response, real-time gaseous measurement system allows for the continuous sampling of a low pressure gaseous environment. A sample of test gas from the low pressure gaseous environment is continuously extracted and pumped to a structural tee joint which is open to the atmosphere at one end to maintain the test gas at a constant pressure. The structural tee joint communicates at the other end with a heater for maintaining the test gas at a constant temperature. From the heater, the test gas is sent to a sensor which develops a voltage that is proportional to the partial pressure of the gaseous component to be measured in the test gas, a constant flow rate of test gas being provided through the heater and sensor. Since test gas pressure, temperature, and flow rate are being held constant, changes in sensor voltage are attributable only to changes in the concentration of the measured gas component.

Sprinkle, Danny R.↗

The two-way time synchronization system via a satellite voice channel

A newly developed two-way time synchronization system is described in this paper. The system uses one voice channel at a SCPC satellite digital communication earth station, whose bandwidth is only 45 kHz, thus saving satellite resources greatly. The system is composed of one master station and one or several, up to sixty-two, secondary stations. The master and secondary stations are equipped with the same equipment, including a set of timing equipment, a synthetic data terminal for time synchronizing, and a interface unit between the data terminal and the satellite earth station. The synthetic data terminal for time synchronization also has an IRIG-B code generator and a translator. The data terminal of master station is the key part of whole system. The system synchronization process is full automatic, which is controlled by the master station. Employing an autoscanning technique and conversational mode, the system accomplishes the following tasks: linking up liaison with each secondary station in turn, establishing a coarse time synchronization, calibrating date (years, months, days) and time of day (hours, minutes, seconds), precisely measuring the time difference between local station and the opposite station, exchanging measurement data, statistically processing the data, rejecting error terms, printing the data, calculating the clock difference and correcting the phase, thus realizing real-time synchronization from one point to multiple points. We also designed an adaptive phase circuit to eliminate the phase ambiguity of the PSK demodulator. The experiments have shown that the time synchronization accuracy is better than 2 mu S. The system has been put into regular operation.

Heng-Qiu, Zheng↗

Time-domain modelling and thermometry of the CH 4 v 1 Q-branch using hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering

Here, we present time-domain measurements and modelling of the CH 4 v 1 vibrational Q-branch, as well as simultaneous temperature acquisition from the CH 4 and N 2 vibrational Q-branches using broadband hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS). Accurate measurements with fs/ps CARS require knowledge of the time-domain response of the probed molecule at different temperatures and pressures. In this work, a fs/ps CARS model was developed for theCH 4 v 1 Q-branch and validated using time-resolved probe delay scans at pressures between 70 and 600 Torr and temperatures between 295 and 1000 K. A simplified modified exponential energy gap model was used to determine the linewidths of the Raman transitions within the Q-branch. Total Q-branch linewidths for the entire explored parameter space were also determined from the probe delay scans. This enabled quantitative measurements of CH 4 with fs/ps CARS as well as the temperature through the hot bands of the CH 4 v 1 Q-branch. With a broadband fs laser pulse in a two-beam phase matching scheme, the N 2 Q-branch and CH 4 v 1 Q-branch were simultaneously measured in a heated cell, and the temperatures from each molecule's spectra was evaluated. Here, the fitted temperatures corresponded well with differences ranging from 4 to 17%. It was also shown that exchanging 90% of CH 4 for N 2 or Ar at 295 K and 500 Torr did not significantly impact the normalized time-domain signal prior to a 100 picosecond probe delay. Spatially resolved one-dimensional (1-D) thermometry using the CH 4 Q-branch was also demonstrated with an imaged spatial resolution of 40 µm. With the developed model, 1-D quantitative measurements of CH 4 concentration and temperature can be measured with time resolution of tens of picoseconds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SONTRAC: A solar neutron track chamber detector

The recent detection on the solar maximum mission (SMM) satellite of high energy neutrons emitted during large solar flares has provided renewed incentive to design a neutron detector which has the sensitivity, energy resolution, and time resolution to measure the neutron time and energy spectra with sufficient precision to improve our understanding of the basic flare processes. Over the past two decades a variety of neutron detectors has been flown to measure the atmospheric neutron intensity above 10 MeV and to search for solar neutrons. The SONTRAC (Solar Neutron Track Chamber) detector, a new type of neutron detector which utilizes n-p scattering and has a sensitivity 1-3 orders of magnitude greater than previous instruments in the 20-200 MeV range is described. The energy resolution is 1% for neutron kinetic energy, T sub n 50 MeV. When used with a coded aperture mask at 50 m (as would be possible on the space station) an angular resolution of approx. 4 arc sec could be achieved, thereby locating the sites of high energy nuclear interactions with an angular precision comparable to the existing x-ray experiments on SMM. The scintillation chamber is investigated as a track chamber for high energy physics, either by using arrays of scintillating optical fibers or by optical imaging of particle trajectories in a block of scintillator.

Frye, G. M., Jr.↗

Polarization and variability of compact sources measured in Planck time-ordered data

This paper introduces a new Planck Catalog of Polarized and Variable Compact Sources (PCCS-PV) comprising 153 sources, the majority of which are extragalactic. The data include both the total flux density and linear polarization measured by Planck with frequency coverage from 30 to 353 GHz, and temporal spacing ranging from days to years. We classify most sources as beamed, extragalactic radio sources; the catalog also includes several radio galaxies, Seyfert galaxies, and Galactic and Magellanic Cloud sources, including H II regions and planetary nebulae. An advanced extraction method applied directly to the multifrequency Planck time-ordered data, rather than the mission sky maps, was developed to allow an assessment of the variability of polarized sources. Our analysis of the time-ordered data from the Planck mission, tod2flux, allowed us to catalog the time-varying emission and polarization properties for these sources at the full range of polarized frequencies employed by Planck, 30-353 GHz. PCCS-PV provides the time-and frequency-dependent, polarized flux densities for all 153 sources. To illustrate some potential applications of the PCCS-PV, we conducted preliminary comparisons of our measurements of selected sources with published data from other astronomical instruments. In summary, we find general agreement between the Planck and the Institut de Radioastronomie Millimétrique (IRAM) polarization measurements as well as with the Metsähovi 37 GHz values at closely similar epochs. Here, these combined measurements also show the value of PCCS-PV results and the PCCS2 catalog for filling in missing spectral (or temporal) coverage and helping to define the spectral energy distributions of extragalactic sources. In turn, these results provide useful clues as to the physical properties of the sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Shock Tube Characterization of Laser Absorption Sensors for Combustion Measurements of Green Propellants

Chemical kinetic models for green spacecraft propulsion systems are needed to calculate efficiency, estimate toxic products, and mitigate plume impingement risks. Laser absorption spectroscopy (LAS) is a common technique used to measure time-resolved mole fraction for model validation. LAS was used to measure species-time history nitrous oxide (N2O) and carbon monoxide (CO) behind reflected shock waves. The diagnostics were implemented at the University of Central Florida high-pressure shock tube facility. A mixture of ethylene (0.002) and N2O (0.008) was diluted with argon gas (0.99) and shock heated 12 bar and temperatures from 1400 to 1600 K.

Marley A. Albright↗