Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stroke”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Observations of Total Lightning Associated with Severe Convection During the Wet Season in Central Florida

This paper will discuss findings of a collaborative lightning research project between National Aeronautics and Space Administration, the Massachusetts Institute of Technology and the National Weather Service office In Melbourne Florida. In August 1996, NWS/MLB received a workstation which incorporates data from the KMLB WSR-88D, Cloud to Ground (CG) stroke data from the National Lightning Detection Network (NLDN), and 3D volumetric lightning data collected from the Kennedy Space Centers' Lightning Detection And Ranging (LDAR) lightning system. The two primary objectives of this lightning workstation, called Lightning Imaging Sensor Data Applications Display (USDAD), are to: observe how total lightning relates to severe convective storm morphology over central Florida, and compare ground based total lightning data (LDAR) to a satellite based lightning detection system. This presentation will focus on objective #1. The LISDAD system continuously displays CG and total lighting activity overlaid on top of the KMLB composite reflectivity product. This allows forecasters to monitor total lightning activity associated with convective cells occurring over the central Florida peninsula and adjacent coastal waters. The LISDAD system also keeps track of the amount of total lightning data, and associated KMLB radar products with individual convective cells occurring over the region. By clicking on an individual cell, a history table displays flash rate information (CG and total lightning) in one minute increments, along with radar parameter trends (echo tops, maximum dBz and height of maximum dBz) every 5 minutes. This history table Is updated continuously, without user intervention, as long as the cell is identified. Reviewing data collected during the 1997 wet season (21 cases) revealed that storms which produced severe weather (hall greater or = 0.75 in. or wind damage) typically showed a rapid rise In total lightning prior to the onset of severe weather. On average, flash rate increases of 25 FPM per minute over a time scale of approximately 5 minutes were common. These pulse severe storms typically reached values of 150 to 200 FPM with some cells exceeding 400 FPM. One finding which could have a direct application to the warning process is that the rapid increase in lightning typically occurred in advance of the warning issuance time. Comparisons between the ending time of the rapid rate increase and the time of when the warning was issued by NWS/MLB meteorologist exhibited a lead time of 8 minutes. It is conceivable that if close monitoring of the LISDAD system by operational meteorologist is routinely performed, warnings for pulse severe storms could be issued up to 4 to 6 minutes earlier than what is issued currently.

Sharp, D.↗

Determination of Thunderstorm Anvil Ice Contents and Other Cloud Properties from Satellite Observations of Lightning

The lightning frequency model developed by Baker, Christian and Latham (1995) has been refined and extended, in an effort to provide a more realistic framework from which to examine computationally the relationships that might exist between lightning frequency f (which is now being routinely measured from satellites, using NASA/MSFC devices) and a variety of cloud physical parameters, including precipitation rate, updraught speed and non-precipitating ice content. The charging mechanism incorporated into the model is the non-inductive ice-ice mechanism - involving rebounding collisions between ice crystals and growing graupel pellets - which has achieved significant field, laboratory and modelling support in recent years. Model results indicate the existence of a simple relationship between lightning frequency f and the upward flux of ice crystals into the thunderstorm anvil. It follows that, for a particular situation, one can assign a specific mass of non-precipitating ice to an individual lightning stroke. Therefore it is possible - using satellite measurements of global lightning - to estimate the atmospheric loading of ice crystals in thunderstorm anvils: a parameter of climatological importance. One can also estimate the ice crystal loading associated with more localized storm systems. Early results from this work will be presented, together with further work on the relationships between f and other thundercloud parameters.

Blyth, Alan M.↗

Determination of Thunderstorm Anvil Ice Contents and Other Cloud Properties from Satellite Observations of Lightning

The lightning frequency model developed by Baker, Christian and Latham (1995) has been refined and extended, in an effort to provide a more realistic framework from which to examine computationally the relationships that might exist between lightning frequency f (which is now being routinely measured from satellites, using NASA/MSFC devices) and a variety of cloud physical parameters, including precipitation rate, updraught speed and non-precipitating ice content. Model results indicate the existence of a simple relationship between lightning frequency f and the upward flux of ice crystals into the thunderstorm anvil. It follows that, for a particular situation, one can assign a specific mass of non-precipitating ice to an individual lightning stroke. Therefore it may prove possible - using satellite measurements of global lightning - to estimate the atmospheric loading of ice crystals in thunderstorm anvils: a parameter of climatological importance. Early results from this work are presented, together with further studies of the relationships between f and other thundercloud parameters.

Blyth, Alan M.↗

Optical Detection of Lightning from Space

Two primary detection techniques (optical and RF) have a proven capability for detecting lightning from low earth orbit. However, the lightning processes that generate the optical and RF signals are vastly different providing significantly different information content from each sensor type. Because of the intervening ionosphere, low frequency RF components do not reach satellite altitudes. As a consequence, many of the processes associated with the major energy release of a lightning event (i.e. return strokes, k-changes, recoil streamers, etc), in all likelihood contribute little to the RF signal arriving at the satellite. The optical output from lighting, on the other hand, has been shown to be highly correlated with the energetic, charge-transferring processes mentioned above. On the down side, the optical energy, while essentially unaffected by the atmosphere once it emerges from the cloud, is heavily scattered within the cloud. While there is little absorption by the cloud, the great optical depth makes the total light energy emerging from the cloud to be dependent on where in the cloud the lightning occurred. Analyses suggest that when lightning is confined to the lowest regions of the cloud, the light is strongly attenuated and detection becomes problematic. Fortunately, the vast majority of lightning flashes are comprised of channels that propagate through the middle of the cloud and higher. These flashes produce bright signals at the top of a cloud and are readily detectable. Presently, we have two optical instruments in orbit. The Optical Transient Detector (OTD) has been orbiting the earth since April, 1995, while the Lightning Imaging Sensor (LIS) was launched on the Tropical Rainfall Measuring Mission (TRMM) in November of 1997. Both instruments are relatively small, solid state optical imagers, designed specifically to detect and locate lightning activity from low earth orbit with high detection efficiency and location accuracy.

Christian, H. J.↗

Initial Comparison of the Lightning Imaging Sensor (LIS) with Lightning Detection and Ranging (LDAR)

The mapping of the lightning optical pulses detected by the Lightning Imaging Sensor (LIS) is compared with the radiation sources by Lightning Detection and Ranging (LDAR) and the National Lightning Detection Network (NLDN) for three thunderstorms observed during and overpasses on 15 August 1998. The comparison involves 122 flashes including 42 ground and 80 cloud flashes. For ground flash, the LIS recorded the subsequent strokes and changes inside the cloud. For cloud flashes, LIS recorded those with higher sources in altitude and larger number of sources. The discrepancies between the LIS and LDAR flash locations are about 4.3 km for cloud flashes and 12.2 km for ground flashes. The reason for these differences remain a mystery.

Ushio, Tomoo↗

Comparison of Ground-Based 3-Dimensional Lightning Mapping Observation with Satellite-Based LIS Observations in Oklahoma

3-dimensional lightning mapping observations were obtained in central Oklahoma during June 1998, using New Mexico Tech's Lightning Mapping Array (LMA). The results have been compared with observations of the discharges from space obtained by NASA's Lightning Imaging Sensor (LIS) on the Tropical Rainfall Measuring Mission (TRMM) spacecraft. Excellent spatial and temporal correlations were obtained between the two sets of observations. All discharges seen by LIS were mapped by the LMA. Most of the detected optical events were associated with lightning channels that extended into the upper part of the storm. Cloud-to-ground discharges that were confined to mid- and lower-altitudes tended to be detected by LIS at the time of late-stage return strokes. Extensive illumination tended to occur in impulsive bursts toward the end or part way through intracloud discharges and appeared to be produced by energetic K-changes that typically occur at these times.

Thomas, Ronald J.↗

Cardiovascular Session Summary

It was apparent that the bed-rest and spaceflight data indicated that decreases in plasma volume and cardiac atrophy along with cardiac remodeling were fundamental changes which predisposed many astronauts to post flight orthostatic intolerance. Despite the recently acquired in-flight and post-flight muscle sympathetic nerve activity findings suggesting that the sympathetic nerve responses were appropriate there remains significant contrary data from bed-rest studies, post- flight stand tests and hind-limb unweighted rat studies that suggest that the vasoconstrictive responses were compromised at least insufficient in susceptible individuals. The key issues raised is whether a diminished increase in sympathetic activity from baseline without changes in 254 First Biennial Space Biomedical Investigators'Workshop Cardiovascular peak response or receptor adaptations is an abnormal response or is an individual variance of response to the accentuated decrease in stroke volume. Data relating autonomic neural control of heart rate were presented to suggest that the vagal and sympathetic control of heart rate was attenuated. Also, bed-rest and space flight induced attenuated baroreflex control of heart rate was shown to be restored to pre-bedrest function by one bout of maximal dynamic exercise. However, these data were confounded by relying on the use of R-R interval as a measure of efferent responses of the baroreflex during a condition in which the baseline heart rate was changed. Clearly the idea that the autonomic control of heart rate may be changed by microgravity needs further investigation. This direction is suggested despite the fact that in the triple product (HR x SV x TPR = MAP) assessment of the regulation of arterial blood pressure during orthostasis the role of the HR reflex may be less influential than that associated. with cardiac atrophy (SV changes) and aberrant sympathetic vasoconstriction (resistance) changes. Although sympathetic nerve activity responses in-flight and post-flight on neurolab appeared appropriate, enough bed-rest and post-flight stand test data, along with animal model data suggest that vasoconstriction was compromised. The mechanism of this compromised vasoconstriction needs to be delineated. Other major findings concerning microgravity and physiological regulatory systems are that: I . Thermoregulatory adaptation appear to suggest some decrements in the control of cutaneous vasodilation and sweating; 2. Calcium resorption and dietary calcium need to be defined for differing durations of spaceflight, especially as the effects of excess calcium on vasomotor function appears to be detrimental; 3. Neurohumoral mechanisms of microgravity induced changes in neural function and the regulation of plasma volume and total body water, bone resorption and autonomic neural control of the circulation need further delineation; 4. As performance of work tasks become prolonged, the mechanisms of blood pressure regulation in microgravity needs to be used in the recovery period from prolonged work tasks.

Raven, Peter↗

Postural Regulation of Muscle Sympathetic Nerve Activity Before and After Simulated and Actual Microgravity Deconditioning

The etiology of orthostatic intolerance after spaceflight is multifaceted. Morphological adaptations, in particular cardiac atrophy, are likely to magnify the decrease in stroke volume that occurs with reductions in cardiac filling pressure when standing. Neural adaptations may be inferred as well, as reductions in carotid-cardiac baroreflex responsiveness have been reported following bedrest deconditioning and spaceflight. Neural control of vascular resistance has not been studied directly when orthostatic intolerance is florid in the hours following spaceflight. However, the increases in systemic vascular resistance and plasma catecholamines during orthostatic stress are inappropriately low in orthostatically intolerant subjects following spaceflight, suggesting that deficits in the regulation of vascular resistance may be associated with hypoadrenergic function. The studies described in this abstract were designed to test this hypothesis.

Pawelczyk, J. A.↗

Influence of Gravity on Blood Volume and Flow Distribution

In our previous experiments during NASA Shuttle flights SLS 1 and 2 (9-15 days) and EUROMIR flights (30-90 days) we observed that pulmonary blood flow (cardiac output) was elevated initially, and surprisingly remained elevated for the duration of the flights. Stroke volume increased initially and then decreased, but was still above 1 Gz values. As venous return was constant, the changes in SV were secondary to modulation of heart rate. Mean blood pressure was at or slightly below 1 Gz levels in space, indicating a decrease in total peripheral resistance. It has been suggested that plasma volume is reduced in space, however cardiac output/venous return do not return to 1 Gz levels over the duration of flight. In spite of the increased cardiac output, central venous pressure was not elevated in space. These data suggest that there is a change in the basic relationship between cardiac output and central venous pressure, a persistent "hyperperfusion" and a re-distribution of blood flow and volume during space flight. Increased pulmonary blood flow has been reported to increase diffusing capacity in space, presumably due to the improved homogeneity of ventilation and perfusion. Other studies have suggested that ventilation may be independent of gravity, and perfusion may not be gravity- dependent. No data for the distribution of pulmonary blood volume were available for flight or simulated microgravity. Recent studies have suggested that the pulmonary vascular tree is influenced by sympathetic tone in a manner similar to that of the systemic system. This implies that the pulmonary circulation is dilated during microgravity and that the distribution of blood flow and volume may be influenced more by vascular control than by gravity. The cerebral circulation is influenced by sympathetic tone similarly to that of the systemic and pulmonary circulations; however its effects are modulated by cerebral autoregulation. Thus it is difficult to predict if cerebral perfusion is increased and if there is edema in space. Anecdotal evidence suggests there may be cerebral edema early in flight. Cerebral artery velocity has been shown to be elevated in simulated microgravity. The elevated cerebral artery velocity during simulated microgravity may reflect vasoconstriction of the arteries and not increased cerebral blood flow. The purpose of our investigations was to evaluate the effects of alterations in simulated gravity (+/-), resulting in changes in cardiac output (+/-), and on the blood flow and volume distribution in the lung and brain of human subjects. The first hypothesis of these studies was that blood flow and volume would be affected by gravity, but their distribution in the lung would be independent of gravity and due to vasoactivity changing vascular resistance in lung vessels. The vasodilitation of the lung vasculature (lower resistance) along with increased "compliance" of the heart could account for the absence of increased central venous pressure in microgravity. Secondly, we postulate that cerebral blood velocity is increased in microgravity due to large artery vasoconstriction, but that cerebral blood flow would be reduced due to autoregulation.

Pendergast, D.↗

Carotid Baroreflex Function During Prolonged Exercise

Astronauts are often required to work (exercise) at moderate to high intensities for extended periods while performing extra-vehicular activities (EVA). Although the physiologic responses associated with prolonged exercise have been documented, the mechanisms involved in blood pressure regulation under these conditions have not yet been fully elucidated. An understanding of this issue is pertinent to the ability of humans to perform work in microgravity and complies with the emphasis of NASA's Space Physiology and Countermeasures Program. Prolonged exercise at a constant workload is know to result in a progressive decrease in mean arterial pressure (MAP) concomitant with a decrease in stroke volume and a compensatory increase in heart rate. The continuous decrease in MAP during the exercise, which is related to the thermoregulatory redistribution of circulating blood volume to the cutaneous circulation, raises the question as to whether there is a loss of baroreflex regulation of arterial blood pressure. We propose that with prolongation of the exercise to 60 minutes, progressive increases on central command reflect a progressive upward resetting of the carotid baroreflex (CBR) such that the operating point of the CBR is shifted to a pressure below the threshold of the reflex rendering it ineffectual in correcting the downward drift in MAP. In order to test this hypothesis, experiments have been designed to uncouple the global hemodynamic response to prolonged exercise from the central command mediated response via: (1) continuous maintenance of cardiac filling volume by intravenous infusion of a dextran solution; and (2) whole body surface cooling to counteract thermoregulatory cutaneous vasodialation. As the type of work (exercise) performed by astronauts is inherently arm and upper body dependent, we will also examine the physiologic responses to prolonged leg cycling and arm ergometry exercise in the supine positions with and without level lower body negative pressure (-10 torr) to mimic spaceflight- related decreases in cardiac filling volumes.

Raven, P. B.↗

Physiologic Pressure and Flow Changes During Parabolic Flight (Pilot Study)

The objective of this study was to obtain measurement of cutaneous tissue perfusion central and peripheral venous pressure, and esophageal and abdominal pressure in human test subjects during parabolic flight. Hemodynamic data recorded during SLS-I and SLS-2 missions have resulted in the paradoxical finding of increased cardiac stroke volume in the presence of a decreased central venous pressure (CVP) following entry in weightlessness. The investigators have proposed that in the absence of gravity, acceleration-induced peripheral vascular compression is relieved, increasing peripheral vascular capacity and flow while reducing central and peripheral venous pressure, This pilot study seeks to measure blood pressure and flow in human test subjects during parabolic flight for different postures.

Pantalos, George↗

Cardiovascular Deconditioning in Humans: Alteration in Cardiovascular Regulation and Function During Simulated Microgravity

Alterations in cardiovascular regulation and function that occur during and after space flight have been reported. These alterations are manifested, for example, by reduced orthostatic tolerance upon reentry to the earth's gravity from space. However, the precise physiologic mechanisms responsible for these alterations remain to be fully elucidated. Perhaps, as a result, effective countermeasures have yet to be developed. In this project we apply a powerful, new method - cardiovascular system identification (CSI) - for the study of the effects of space flight on the cardiovascular system so that effective countermeasures can be developed. CSI involves the mathematical analysis of second-to-second fluctuations in non-invasively measured heart rate, arterial blood pressure (ABP), and instantaneous lung volume (ILV - respiratory activity) in order to characterize quantitatively the physiologic mechanisms responsible for the couplings between these signals. Through the characterization of all the physiologic mechanisms coupling these signals, CSI provides a model of the closed-loop cardiovascular regulatory state in an individual subject. The model includes quantitative descriptions of the heart rate baroreflex, autonomic function, as well as other important physiologic mechanisms. We are in the process of incorporating beat-to-beat fluctuations of stroke volume into the CSI technique in order to quantify additional physiologic mechanisms such as those involved in control of peripheral vascular resistance and alterations in cardiac contractility. We apply CSI in conjunction with the two general protocols of the Human Studies Core project. The first protocol involves ground-based, human head down tilt bed rest to simulate microgravity and acute stressors - upright tilt, standing and bicycle exercise - to provide orthostatic and exercise challenges. The second protocol is intended to be the same as the first but with the addition of sleep deprivation to determine whether this contributes to cardiovascular alterations. In these studies, we focus on the basic physiologic mechanisms responsible for the alterations in cardiovascular regulation and function during the simulated microgravity in order to formulate hypotheses regarding what countermeasures are likely to be most effective. Compared to our original proposal, the protocol we are using has been slightly modified to lengthen the bed rest period to 16 days and streamline the data collection. These modifications provide us data on a longer bed rest period and have enabled us to increase our subject throughput. Based on review of our preliminary data we have decided to test a countermeasure which is applied the very end of the bed rest period. We will use the same bed rest protocol to test this countermeasure. We anticipate completing the baseline data collection in our first protocol plus testing of the countermeasure in an additional eight subjects, at which time we plan to initiate the second protocol which includes sleep deprivation. In future studies, we plan to apply CSI to test other potential countermeasures in conjunction with the same bed rest, sleep deprivation and acute stressor models. We also anticipate applying CSI for studying astronauts before and after space flight and ultimately, during space flight. The application of CSI is providing information relevant to the development and evaluation of effective countermeasures allowing humans to adapt appropriately upon re-exposure to a gravity field, and to live and work for longer periods of time in microgravity.

Cohen, Richard↗

Analysis and Assessment of Peak Lightning Current Probabilities at the NASA Kennedy Space Center

This technical memorandum presents a summary by the Electromagnetics and Aerospace Environments Branch at the Marshall Space Flight Center of lightning characteristics and lightning criteria for the protection of aerospace vehicles. Probability estimates are included for certain lightning strikes (peak currents of 200, 100, and 50 kA) applicable to the National Aeronautics and Space Administration Space Shuttle at the Kennedy Space Center, Florida, during rollout, on-pad, and boost/launch phases. Results of an extensive literature search to compile information on this subject are presented in order to answer key questions posed by the Space Shuttle Program Office at the Johnson Space Center concerning peak lightning current probabilities if a vehicle is hit by a lightning cloud-to-ground stroke. Vehicle-triggered lightning probability estimates for the aforementioned peak currents are still being worked. Section 4.5, however, does provide some insight on estimating these same peaks.

Johnson, D. L.↗

Mechanism of Thirst Attenuation During Head-Out Water Immersion in Men

The purpose was to determine whether extracellular volume or osmolality was the major contributing factor for reduction of thirst in air and head-out water immersion in hypohydrated subjects. Eight males (19 - 25 yr) were subjected to thermoneutral immersion and thermoneutral air under two hydration conditions without further drinking: euhydration in water (Eu-H2O) and euhydration in air, and hypohydration in water (Hypo-H2O) and hypohydration in air (3.7% wt loss after exercise in heat). The increased thirst sensation with Hypo-H2O decreased (P less than 0.05) within 10 min of immersion and continued thereafter. Mean plasma osmolality (288 +/- 1 mosmol/kg H2O) and sodium (140 +/- 1 meq/1) remained elevated, and plasma volume increased by 4.2 +/- 1.0% (P less than 0.05) throughout Hypo-H2O. A sustained increase (P less than 0.05) in stroke volume accompanied the prompt and sustained decrease in plasma renin activity and sustained increase (P less than 0.05) in plasma atrial natriuretic peptide during Eu-H2O and Hypo-H2O. Plasma vasopressin decreased from 5.3 +/- 0.7 to 2.9 +/- 0.5 pg/ml (P less than 0.05) during Hypo-H2O but was unchanged in Eu-H2O. These findings suggest a sustained stimulation of the atrial baroreceptors and reduction of a dipsogenic stimulus without major alterations of extracellular osmolality in Hypo-H2O. Thus it appears that vascular volume induced stimuli of cardiopulmonary baroreceptors play a more important role than extracellular osmolality in reducing thirst sensations during immersion in hypohydrated subjects. Thus the purpose for this study was to determine the relative importance of volume and osmotic stimuli, and associated hormonal interaction, for attenuation of thirst during immersion.

Wada, F.↗

Marked Exacerbation of Orthostatic Intolerance After Long vs. Short-Duration Spaceflight in Veteran Astronauts

The incidence of postflight orthostatic intolerance following short-duration spaceflight is about 20%. However, the incidence following long-duration spaceflight is unknown. We performed tilt tests on six astronauts before and after their long-duration (129 - 190 days) spaceflights and compared these data to those obtained during stand tests before and after their previous short-duration missions and also to tilt test data from 20 different short-duration (8 - 16 days) flight astronauts. Five of these six became presyncopal during tilt testing after long-duration flights: only one had become presyncopal during stand testing after short-duration flights. Five of the twenty astronauts who flew on other short-duration flights, became presyncopal during upright tilt on landing day. Long-duration presyncopal subjects had lower stroke volumes, lower cardiac outputs and higher peripheral vascular resistance than short-duration presyncopal subjects, but their heart rate responses were not different. One subject had subnormal norepinephrine release with upright posture after a long but not short flight. Plasma volume losses were not greater after long flights. Long-duration spaceflight markedly increases orthostatic intolerance, probably related to altered autonomic function.

Fritsch-Yelle, Janice M.↗

Experimental Development and Physical Analysis of Jet and Vortex Actuators

The Vortex generator consists of a cavity with a lightweight actuator plate. The actuator plate acts like a piston pumping air out of the cavity on the down-stroke and sucking air into the cavity on the upstroke. The actuator is placed asymmetrically over the cavity opening, forming narrow and wide slots when viewed from the top. The actuator depending on amplitude, frequency, and slot spacing produces several flow fields (free jet, wall jet, vortex flow). Computational simulation of the actuator-generated flows have been developed and applied to several actuator flow modes. The objectives of this paper are to study the physics of the actuator-induced flow and to develop computational simulations of the actuatorgenerated flows. This work should provide an impetus for designing similar active flow control systems suitable for aircraft applications. The computational simulation uses a time-accurate full Navier-Stokes (NS) solver known as FTNS3D (a full NS version of CFL3D solver). A Multi-block moving grid has been developed and used for the computational study of the flow fields produced by the vortex generator. For three-dimensional computations, ten multi-block grids are used and for two-dimensional computations, six multiblock grids are used. The grid blocks adjacent to the actuator plate move with the plate motion, and second-order interpolation is used along the block interfaces. Periodic response of the flow has been observed to develop after three cycles of the plate sinusoidal motion.

Kandil, Osama A.↗

Efficient Hybrid Actuation Using Solid-State Actuators

Piezohydraulic actuation is the use of fluid to rectify the motion of a piezoelectric actuator for the purpose of overcoming the small stroke limitations of the material. In this work we study a closed piezohydraulic circuit that utilizes active valves to rectify the motion of a hydraulic end affector. A linear, lumped parameter model of the system is developed and correlated with experiments. Results demonstrate that the model accurately predicts the filtering of the piezoelectric motion caused by hydraulic compliance. Accurate results are also obtained for predicting the unidirectional motion of the cylinder when the active valves are phased with respect to the piezoelectric actuator. A time delay associated with the mechanical response of the valves is incorporated into the model to reflect the finite time required to open or close the valves. This time delay is found to be the primary limiting factor in achieving higher speed and greater power from the piezohydraulic unit. Experiments on the piezohydraulic unit demonstrate that blocked forces on the order of 100 N and unloaded velocities of 180 micrometers/sec are achieved.

Leo, Donald J.↗

Effects of Three-Day Bed Rest on Physiological Responses to Graded Exercise in Endurance Athletes, Body Builders and Sedentary Men

To test the hypotheses that short-term bed rest (BR) deconditioning influences metabolic, cardiorespiratory and neurohormonal responses to exercise and that these effects depend on the subjects' training status 12 sedentary men, and 10 endurance- and 10 strength-trained athletes were submitted to three-day BR. Before and after BR they performed incremental exercise test until volitional exhaustion. Respiratory gas exchange and HR were recorded continuously and stroke volume (SV) was measured at submaximal loads. Blood was taken for lactate [LA], adrenaline [A], noradrenaline, [NA], renting activity (PRA), growth hormone [hGH], testosterone and cortisol determination. Reduction of peak oxygen uptake (VO2peak) after BR was greater in the endurance athletes (than in the remaining groups (17 % vs. 100%). Decrements in VO2peak correlated positively with the initial values (r = 0.73, p less than 0.001). Resting and exercise respiratory exchange ratios were increased in athletes. Cardiac output was unchanged by BR in all groups, but exercise HR was increased and SV diminished in the sedentary subjects. The submaximal [LA] and [LA] thresholds were decreased the in endurance athletes from 71 to 60 %VO2 peak (p less than 0.001); they also had an earlier increase in [NA], and an attenuated increase in [hGH), and accentuated PRA and cortisol elevations during exercise. These effects were insignificant in the remaining subjects. In conclusion: reduction of exercise performance and modifications in neurohormonal response to exercise after BR depend on the previous level and mode of physical training, being the most pronounced in the endurance athletes.

Smorawinski, J.↗