Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “static testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

A curved beam test specimen for determining the interlaminar tensile strength of a laminated composite

A curved beam type of test specimen is evaluated for use in determining the through-the-thickness strength of laminated composites. Two variations of a curved beam specimen configuration (semi-circular and elliptical) were tested to failure using static and fatigue loads. The static failure load for the semi-circular specimens was found to be highly sensitive to flaw content, with the specimens falling into two distinct groups. This result supports the use of proof testing for structural validation. Static design allowables are derived based on the Weibull distribution. Fatigue data indicates no measured increase in specimen compliance prior to final fracture. All static and fatigue failures at room temperature dry conditions occurred catastrophically. The elliptical specimens demonstrated unusually high failure strengths indicating the presence of phenomena requiring further study. Results are also included for specimens exposed to a wet environment showing a matrix strength degradation due to moisture content. Further testing is under way to evaluate a fatigue methodology for matrix dominated failures based on residual static strength (wearout).

Hiel, Clement C.↗

Three-Axis Distributed Fiber Optic Strain Measurement in 3D Woven Composite Structures

Recent advancements in composite materials technologies have broken further from traditional designs and require advanced instrumentation and analysis capabilities. Success or failure is highly dependent on design analysis and manufacturing processes. By monitoring smart structures throughout manufacturing and service life, residual and operational stresses can be assessed and structural integrity maintained. Composite smart structures can be manufactured by integrating fiber optic sensors into existing composite materials processes such as ply layup, filament winding and three-dimensional weaving. In this work optical fiber was integrated into 3D woven composite parts at a commercial woven products manufacturing facility. The fiber was then used to monitor the structures during a VARTM manufacturing process, and subsequent static and dynamic testing. Low cost telecommunications-grade optical fiber acts as the sensor using a high resolution commercial Optical Frequency Domain Reflectometer (OFDR) system providing distributed strain measurement at spatial resolutions as low as 2mm. Strain measurements using the optical fiber sensors are correlated to resistive strain gage measurements during static structural loading. Keywords: fiber optic, distributed strain sensing, Rayleigh scatter, optical frequency domain reflectometry

Castellucci, Matt↗

Identification of Noise Sources in a Rocket Engine Test Stand using Microphone Phased Array

A new, phased array of microphones, suitable for the harsh environment of a rocket launch, was built and tested during a static firing of a RS-25 engine. It uses 70 piezo-resistive, dynamic pressure sensors, optimally distributed on a 10.5ft diameter open frame dome structure, and has a 200-ft long cable bundle to carry the signals to a weather-protected cabinet containing the data systems. The test stand was imaged using an infra-red camera and a visible wavelength camera, and the beamformed noise maps were superimposed on the photographs. The first-time data from a full-scale engine test stand showed that the plume deflector at the bottom of the engine to be the primary noise source. The openings of the test stand around the nozzle exit were also found to be noise sources particularly at higher frequencies. The final goal is to use the array during NASA’s Artemis-II launch at Kennedy Space Center.

Identification of Noise Source↗

The characteristics of a lift cruise fan V/STOL configuration in near proximity to a small deck with finite edge positions

Two V/STOL model configurations utilizing lift-cruise-fans for the propulsion system have been tested in the presence of a small landing platform with finite deck edge positions. Results and analysis of these tests are presented. The model was tested at both static (zero velocity) and forward speed conditions with several heights and deck edge positions. Configurations utilizing three fans and four fans were investigated. Incremental forces and moments induced by the various deck edge positions are analyzed as relating to the model height above the ground and the thrust velocity relationships. The test and analysis show the induced forces to be relatively unaffected by deck edge.

Stewart, V. R.↗

Modeling of Fillets in Thin-Walled Structures for Dynamic Analysis

Relatively new developments in manufacturing methods have made it possible to produce machined parts with a wall thickness of less than 0.010". While the parts are being machined. Fillets of relatively large radius to thickness ratios are created by the milling tool. This paper discusses an accurate new technique for finite-element modeling of fillets for dynamic and stiffness analysis using efficient plate elements rather than more computationally intensive, high density solid meshes, A simple filleted cantilever beam of 0.040" thickness, 1.6" length, 1" depth, and 0.250" radius in the corner was modeled using both solid elements and several different plate element geometries. The finite element results were then compared with static and modal testing of a machined sample. The highest-scoring plate element technique uses a bridge of elements that is constructed through the tangent point of the Fillet radius such that the thickness of the element matches tile volume of the fillet. This model produces errors of less than 4.6 percent for static loading and less than 7.4 percent for modal analysis. This simple plate element technique will prove critical for efficient, timely, and accurate dynamic analysis of complex thin-walled structures.

Seugling, Richard M.↗

Experimental investigation of geometry and flow effects on acoustic radiation from duct inlets

An experimental study of the effects of geometry, flow, frequency and source structure on the radiation and reflection of sound from duct inlets has been conducted. This work extends a previous study by comparing two inlet shapes typical of static and flight testing and by considering higher order radial modes. Measurements of the internal and radiated acoustic fields are presented in terms of modal reflection coefficients and absolute radiated pressure directivity. Results indicate that geometry effects associated with these practical inlet shapes become less important for a fixed cutoff ratio as the mode order and frequency are increased. Also, static inflow, while reducing the reflected wave amplitude, is shown to have little effect on radiation directivity regardless of inlet geometry.

Silcox, R. J.↗

Static Longitudinal and Lateral Stability and Control Data Obtained from Tests of a 1/15-Scale Model of the Goodyear XZP5K Airship, TED No. NACA DE 211

Static longitudinal and lateral stability and control data are presented of an investigation on a l/15-scale model of the Goodyear XZP5K airship over a pitch and yaw range of +/-20 deg and 0 deg to 30 deg, respectively, for various rudder and elevator deflections. Two tail configurations of different plan forms were tested and wake and boundary-layer surveys were conducted. Testing was conducted in the Langley full-scale tunnel at a Reynolds number of approximately 16.5 x 10(exp 6) based on hull length, and corresponds to a Mach number of about 0.12.

Cannon, Michael D.↗

Space shuttle: Experimental investigations for base drag reduction on a 0.015 scale model MSFS proposed space shuttle booster at Mach numbers from 0.40 to 1.10

A 0.015-scale model of a modified version of the MDAC space shuttle booster was tested to obtain force, static stability, and control effectiveness data. The objective of this test was the reduction of cruise (M = 0.4) base drag by the use of base flaps, base vents, elevon deflection and base flow from a plenum mounted forward of the base heat shield. Transonic data were also obtained to determine the aerodynamic characteristics of the new base shape. Six component aerodynamic force and moment data were recorded over an angle of attack range from 4 deg to 20 deg at 0 deg sideslip and over a sideslip range from -6 deg to 6 deg at 0 deg, 6 deg and 15 deg angle of attack. Mach number varied from 0.4 to 1.10 at a constant R of 2 million per unit length.

Bradley, D.↗

Interface Finite Elements for the Analysis of Fracture Initiation and Progression

Progressive failure analyses (PFA) are important for the prediction of residual strength and damage tolerance of vehicle structures, and to predict the energy absorbing capability of vehicle structures under crash-type loads. Typically continuum damage mechanics (CDM) and fracture mechanics (FM) are the methods used for PFA. The method of interfacial damage mechanics (IDM) is used for PFA in this research. IDM has capabilities intermediate between CDM and FM, and is used to numerically model the initiation, growth, and arrest of cracks. IDM smooths the stress singularity at the crack tip, and is easily adaptable with other nonlinearties such as plasticity and material damage. IDM is implemented by user-defined interface elements in the ABAQUS/ Standard structural analysis software package. The structural components selected to demonstrate the effectiveness PFA using interface elements are, for the most part, those with published test data. These structural components were subjected to quasi-static loading in the tests. Thus, the ABAQUS analyses are used to predict geometrically and materially nonlinear equilibrium states. Impact loading, dynamic fracture, reflected stress waves, inertia, and time dependent material behavior are not considered.

Ambur, Damodar R.↗

Aero-Propulsive Damping Characterization for eVTOL Aircraft Using Free Motion Wind-Tunnel Testing

This paper describes an electric vertical takeoff and landing (eVTOL) aircraft system identification method applied using three degree-of-freedom (3DOF) free motion wind-tunnel testing. The approach, similar to flight-test system identification, allows for efficient mathematical model development of the aero-propulsive moments applied on an eVTOL vehicle, including aerodynamic damping effects. The approach is demonstrated using a subscale tiltrotor eVTOL aircraft mounted on a new 3DOF wind-tunnel apparatus. To execute the test, a model-based 3DOF control system is designed to track attitude commands and transition the aircraft based on the freestream dynamic pressure. While the flight controller is active, orthogonal phase-optimized multisine inputs are injected into the attitude command and control effector command signals to enable collection of informative data for model identification. Aero-propulsive models are then identified at several reference conditions in the transition flight envelope using the equation-error method in the frequency domain. The identified models are shown to have a good fit to the modeling data and good prediction capability of data not used for model identification. The method yields aerodynamic damping estimates using less wind-tunnel test time compared to traditional forced oscillation experiments and supplements static wind-tunnel testing to produce a comprehensive transition aero-propulsive model suitable for use in flight dynamics simulations.

RAVEN↗

Calibration of HYPULSE for hypervelocity air flows corresponding to flight Mach numbers 13.5, 15, and 17

A series of air calibration tests were performed in GASL's HYPULSE facility in order to more accurately determine test section flow conditions for flows simulating total enthalpies in the Mach 13 to 17 range. Present calibration data supplements previous data and includes direct measurement of test section pitot and static pressure, acceleration tube wall pressure and heat transfer, and primary and secondary incident shock velocities. Useful test core diameters along with the corresponding free-stream conditions and usable testing times were determined. For the M13.5 condition, in-stream static pressure surveys showed the temporal and spacial uniformity of this quantity across the useful test core. In addition, finite fringe interferograms taken of the free-stream flow at the test section did not indicate the presence of any 'strong' wave system for any of the conditions investigated.

Calleja, John↗

Honeycomb Core Permeability Under Mechanical Loads

A method for characterizing the air permeability of sandwich core materials as a function of applied shear stress was developed. The core material for the test specimens was either Hexcel HRP-3/16-8.0 and or DuPont Korex-1/8-4.5 and was nominally one-half inch thick and six inches square. The facesheets where made of Hercules' AS4/8552 graphite/epoxy (Gr/Ep) composites and were nominally 0.059-in. thick. Cytec's Metalbond 1515-3M epoxy film adhesive was used for co-curing the facesheets to the core. The permeability of the specimens during both static (tension) and dynamic (reversed and non-reversed) shear loads were measured. The permeability was measured as the rate of air flow through the core from a circular 1-in2 area of the core exposed to an air pressure of 10.0 psig. In both the static and dynamic testing, the Korex core experienced sudden increases in core permeability corresponding to a core catastrophic failure, while the URP core experienced a gradual increase in the permeability prior to core failure. The Korex core failed at lower loads than the HRP core both in the transverse and ribbon directions.

Glass, David E.↗

Design, Fabrication and Test of Multi-Fiber Laminates

Unidirectional and angleply multifiber laminates were tested for improved impact strength and other mechanical properties. The effects of several variables on the mechanical properties of epoxy matrix materials were described. These include fiber type (HMS and AS graphites, glass, and Kevlar 49), ratio of primary to hybridizing fiber and hybrid configuration. It is demonstrated that AS graphite/S glass in an intraply configuration results in the best combination of static and Charpy impact properties as well as superior ballistic impact resistance. Pendulum impact tests which were conducted on thin specimens are shown to produce different ranking of materials than tests conducted on standard thickness Charpy specimens. It is shown that the thin specimen results are in better agreement with the ballistic impact data. Additional static test data are reported as a function of temperature for the seven best hybrid configurations having epoxy, polyimide (PMR-15) and polyphenylquinoxaline resins as the matrix.

Pike, R. A.↗

Effect of axial impact on the static flexure of graphite/epoxy beams

Graphite-epoxy beams were subjected to an eccentric axial impact load in a drop tower test fixture in order to study their large displacement flexural behavior. The time history of the transient axial load exhibited a large magnitude occurring just after impact, which was many times greater than the static failure load. The damage caused by this peak dynamic load was measured by the reduction in energy absorption of the impacted beam relative to a virgin beam in static tests. For the thirty-ply specimens, the amount of damage increased with increasing axial stiffness.

Sensmeier, M. D.↗

DC-10 composite vertical stabilizer ground test program

A review of the structural configuration and ground test program is presented. Particular emphasis is placed on the testing of a full-scale stub box test subcomponent and full span ground test unit. The stub box subcomponent was tested in an environmental chamber under ambient, cold/wet, and hot/wet conditions. The test program included design limit static loads, fatigue spectrum loading to approximately two service lifetimes (with and without damage), design limit damage tolerance tests, and a final residual strength test to a structural failure. The first full-scale ground test unit was tested under ambient conditions. The test unit was to have undergone static, fatigue, and damage tolerance tests but a premature structural failure occurred at design limit load during the third limit load test. A failure theory was developed which explains the similarity in types of failure and the large load discrepancy at failure between the two test articles. The theory attributes both failures to high stress concentrations at the edge of the lower rear spar access opening. A second full-scale ground test unit has been modified to incorporate the various changes resulting from the premature failure. The article has been assembled and is active in the test program.

Palmer, J. M., Jr.↗

Oxidation of Ultra-High Temperature Ceramics in Water Vapor

Ultra high temperature ceramics (UHTCs) including HfB2 + SiC (20% by volume), ZrB2 + SiC (20% by volume) and ZrB2 + SiC (14% by volume) + C (30% by volume) have historically been evaluated as reusable thermal protection systems for hypersonic vehicles. This study investigates UHTCs for use as potential combustion and aeropropulsion engine materials. These materials were oxidized in water vapor (90%) using a cyclic vertical furnace at 1 atm. The total exposure time was 10 hours at temperatures of 1200, 1300, and 1400 C. CVD SiC was also evaluated as a baseline comparison. Weight change measurements, X-ray diffraction analyses, surface and cross-sectional SEM and EDS were performed. These results will be compared with tests ran in static air at temperatures of 1327, 1627, and 1927 C. Oxidation comparisons will also be made to the study by Tripp. A small number of high pressure burner rig (HPBR) results at 1100 and 1300 C will also be discussed. Specific weight changes at all three temperatures along with the SIC results are shown. SiC weight change is negligible at such short duration times. HB2 + SiC (HS) performed the best out of all the tested UHTCS for all exposure temperatures. ZrB2 + Sic (ZS) results indicate a slightly lower oxidation rate than that of ZrBl + SiC + C (ZCS) at 1200 and 1400 C, but a clear distinction can not be made based on the limited number of tested samples. Scanning electron micrographs of the cross-sections of all the UHTCs were evaluated. A representative area for HS is presented at 1400 C for 26 hours which was the composition with the least amount of oxidation. A continuous SiO2 scale is present in the outer most edge of the surface. An image of ZCS is presented at 1400 C for 10 hours, which shows the most degradation of all the compositions studied. Here, the oxide surface is a mixture of ZrSiO4, ZrO2 and SO2.

Nguyen, QuynhGiao N.↗

Free-To-Roll Analysis of Abrupt Wing Stall on Military Aircraft at Transonic Speeds

Transonic free-to-roll and static wind tunnel tests for four military aircraft - the AV-8B, the F/A-18C, the preproduction F/A-18E, and the F-16C - have been analyzed. These tests were conducted in the NASA Langley 16-Foot Transonic Tunnel as a part of the NASA/Navy/Air Force Abrupt Wing Stall Program. The objectives were to evaluate the utility of the free-to-roll test technique as a tool for predicting areas of significant uncommanded lateral motions and for gaining insight into the wing-drop and wing-rock behavior of military aircraft at transonic conditions. The analysis indicated that the free-to-roll results had good agreement with flight data on all four models. A wide range of motions - limit cycle wing rock, occasional and frequent damped wing drop/rock and wing rock divergence - were observed. The analysis shows the effects that the static and dynamic lateral stability can have on the wing drop/rock behavior. In addition, a free-to-roll figure of merit was developed to assist in the interpretation of results and assessment of the severity of the motions.

Owens, D. Bruce↗

Design and fabrication of gas bearings for Brayton cycle rotating unit

Analysis, design, and testing of two types of pivoted pad journal bearings and a spiral-grooved thrust bearing suitable for direct installation into the NASA 2 to 15 KW Brayton Cycle Rotating Unit (BRU) have been accomplished. Both types of tilting pad bearing assemblies are of the preloaded type, consisting of three pads with one pad flexibly mounted. One type utilizes a non-conforming pivot, while the other replaces the conventional spherical pivot with a cruciform flexible member. The thrust bearing is flexure mounted to accommodate static machine mislinement. Test results indicate that both types of journal bearings should satisfy the requirements imposed by the BRU. Hydrostatic tests of the spiral-grooved thrust bearing showed it to be free of pneumatic hammer with as many as 24 orifices over the BRU pressure and load range.

Frost, A.↗