Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometry data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

The ITER Radial Neutron Camera Detection System

A multichannel neutron detection system (Radial Neutron Camera, RNC) will be installed on the ITER equatorial port plug 1 for total neutron source strength, neutron emissivity/ion temperature profiles and n{sub t}/n{sub d} ratio measurements [1]. The system is composed by two fan shaped collimating structures: an ex-vessel structure, looking at the plasma core, containing tree sets of 12 collimators (each set lying on a different toroidal plane), and an in-vessel structure, containing 9 collimators, for plasma edge coverage. The RNC detecting system will work in a harsh environment (neutron fiux up to 10{sup 8}-10{sup 9} n/cm{sup 2} s, magnetic field >0.5 T or in-vessel detectors), should provide both counting and spectrometric information and should be flexible enough to cover the high neutron flux dynamic range expected during the different ITER operation phases. ENEA has been involved in several activities related to RNC design and optimization [2,3]. In the present paper the up-to-date design and the neutron emissivity reconstruction capabilities of the RNC will be described. Different options for detectors suitable for spectrometry and counting (e.g. scintillators and diamonds) focusing on the implications in terms of overall RNC performance will be discussed. The increase of the RNC capabilities offered by the use of new digital data acquisition systems will be also addressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oxygen isotope characteristics of chondrules from the Yamato-82094 ungrouped carbonaceous chondrite: Further evidence for common O-isotope environments sampled among carbonaceous chondrites

In this study, high-precision secondary ion mass spectrometry (SIMS) was employed to investigate oxygen three isotopes of phenocrysts in 35 chondrules from the Yamato (Y) 82094 ungrouped 3.2 carbonaceous chondrite. Twenty-one of 21 chondrules have multiple homogeneous pyroxene data (Δ 17 O 3SD analytical uncertainty: 0.7‰); 17 of 17 chondrules have multiple homogeneous pyroxene and plagioclase data. Twenty-one of 25 chondrules have one or more olivine data matching coexisting pyroxene data. Such homogeneous phenocrysts (1) are interpreted to have crystallized from the final chondrule melt, defining host O-isotope ratios; and (2) suggest efficient O-isotope exchange between ambient gas and chondrule melt during formation. Host values plot within 0.7‰ of the primitive chondrule mineral (PCM) line. Seventeen chondrules have relict olivine and/or spinel, with some δ 17 O and δ 18 O values approaching -40‰, similar to CAI or AOA-like precursors. Regarding host chondrule data, 22 of 34 have Mg#s of 98.8–99.5 and Δ 17 O of -3.9‰ to -6.1‰, consistent with most Acfer 094, CO, CR, and CV chondrite chondrules, and suggesting a common reduced O-isotope reservoir devoid of 16 O-poor H 2 O. Six Y-82094 chondrules have Δ 17 O near -2.5‰, with Mg#s of 64–97, consistent with lower Mg# chondrules from Acfer 094, CO, CR, and CV chondrites; their signatures suggest precursors consisting of those forming Mg# ~99, Δ 17 O: -5‰ ± 1‰ chondrules plus 16 O-poor H 2 O, at high dust enrichments. Three type II chondrules plot slightly above the PCM line, near the terrestrial fractionation line (Δ 17 O: ~+0.1‰). Their O-isotopes and olivine chemistry are like LL3 type II chondrules, suggesting they sampled ordinary chondrite-like chondrule precursors. Finally, three Mg# >99 chondrules have Δ 17 O of -6.7‰ to -8.1‰, potentially due to 16 O-rich refractory precursor components. Finally, the predominance of Mg# ~99, Δ 17 O: -5‰ ± 1‰ chondrules and a high chondrule-to-matrix ratio suggests bulk Y-82094 characteristics are closely related to anhydrous dust sampled by most carbonaceous chondrite chondrules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Kinetics of the reaction O + ClO yields Cl + O2

The kinetics of the reaction O + ClO yields Cl + O2 (k1) were studied by using resonance fluorescence to monitor the decay of O atoms which had been generated from the laser photolysis of ClO. A discharge flow system was used to generate the ClO and its concentration was measured directly by multipass absorption spectrometry. The results are k1(298) = (4.2 + or -0.8) x 10 to the -11th cu cm/s (including systematic errors) with E/R determined to lie in the range + or - 200 K. The literature data are reviewed and a composite value of k1(T) = 6.0 x 10 to the -11th exp-(100/T) is recommended for stratospheric modeling calculations. The atmospheric implications of the revised rate constant are discussed briefly.

Margitan, J. J.↗

Process Analyzer

The ChemScan UV-6100 is a spectrometry system originally developed by Biotronics Technologies, Inc. under a Small Business Innovation Research (SBIR) contract. It is marketed to the water and wastewater treatment industries, replacing "grab sampling" with on-line data collection. It analyzes the light absorbance characteristics of a water sample, simultaneously detects hundreds of individual wavelengths absorbed by chemical substances in a process solution, and quantifies the information. Spectral data is then processed by ChemScan analyzer and compared with calibration files in the system's memory in order to calculate concentrations of chemical substances that cause UV light absorbance in specific patterns. Monitored substances can be analyzed for quality and quantity. Applications include detection of a variety of substances, and the information provided enables an operator to control a process more efficiently.

Source record↗

A Multi-Sims Investigation of Water Content and D/H Ratios in Roberts Massif 04262 with Insight to Sources of Hydrogen in Maskelynite

We want to define the H2O content ([H2O]) and hydrogen (H) isotope composition of meteoritic material from Mars [1-3] with motivation to understand Mars’ volatile history, constrain geochemical signatures of interior water reservoirs (i.e. the Martian mantle) and explore effects of planetary (e.g. planet formation, magma ocean degassing) and local (e.g. volcanic degassing, impact melting and degassing) processes on H incorporated in minerals. Secondary ion mass spectrometry (SIMS) allows multiple avenues to address these questions. However, application to (1) precious astromaterials and (2) low level H measurements, pose specific challenges that are further complicated when combined. We present preliminary data of a multi-approach (SIMS vs. NanoSIMS) study of H in Roberts Massif 04262 (RBT 04262), an enriched lherzolitic shergottite with nonpoikilitic (NP) and poikilitic (P) lithologies [4]. We analyze olivine, pyrox-ene, and melt inclusions to compare indigenous mantle water, with impact-generated maskelynite to investigate H signatures due to shock.

Dudley, J. M.↗

An Advanced ISOCS In Situ Gamma Spectrometry Services Tool to Reduce Uncertainties in Waste Characterization Projects - 16311

Canberra's In Situ Object Counting System (ISOCS) is an established tool used for gamma spectrometry allowing a physical representation of complex geometries and mathematical calculation of the calibration function. It avoids the need for radioisotope standards which can be costly and prohibitively difficult to produce. Uncertainties in the sample - detector geometry lead to uncertainties in the calibrations. Canberra's ISOCS Uncertainty Estimator (IUE) tool offers an automated means of accommodating known model geometry uncertainties, with calculation of robust defensible calibration uncertainties. However these uncertainties may be large leading to potential over-estimation of under-estimation of activity. This can be equated directly to waste disposal costs if one is using ISOCS for waste sentencing to classify wastes as (for example) Transuranic Waste (TRU) or Low Level Waste (LLW). An Advanced ISOCS in-situ Gamma Spectrometry (AIGS) services tool has been developed to reduce the uncertainties. This system is based on generating and comparing geometry models that yield Figures of Merit (FoM) indicative of improved consistency between modelled data and available diverse measurement data. This paper describes the development and features of AIGS, focusing on recent testing with radioisotope sources in a 200 litre drum filled with a simulated waste matrix. The results demonstrate a significant advantage for Am-241 where uncertainties can otherwise amount to a factor of 2 or more. We show how our specialist teams can develop procedures for deployment of standard ISOCS hardware, adapting measurement geometries and procedures through careful planning, to provide data that can be used to greatly reduce the uncertainties in the measured activities. Lastly, we comment on the range of potential applications for this new technique and the wider benefits for the decommissioning industry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

First Penning trap mass measurement of 36 Ca

Background: Isobaric quintets provide the best test of the isobaric multiplet mass equation (IMME) and can uniquely identify higher order corrections suggestive of isospin symmetry breaking effects in the nuclear Hamilto nian. The Generalized IMME (GIMME) is a novel microscopic interaction theory that predicts an extension to the quadratic form of the IMME. Only the A = 20, 32 T = 2 quintets have the exotic T z = –2 member ground state mass determined to high-precision by Penning trap mass spectrometry. Purpose: To establish A = 36 as the third high-precision T = 2 isobaric quintet with the T z = –2 member ground state mass measured by Penning trap mass spectrometry and provide the first test of the predictive power of the GIMME. Method: Here, a radioactive beam of neutron-deficient 36 Ca was produced by projectile fragmentation at the National Superconducting Cyclotron Laboratory. The beam was thermalized and the mass of 36 Ca + and 36 Ca 2+ measured by the Time of Flight - Ion Cyclotron Resonance method in the LEBIT 9.4 T Penning trap. Results: We measure the mass excess of 36 Ca to be ME= –6483.6(56) keV, an improvement in precision by a factor of 6 over the literature value. The new datum is considered together with evaluated nuclear data on the A = 36, T = 2 quintet. We find agreement with the quadratic form of the IMME given by isospin symmetry, but only coarse qualitative agreement with predictions of the GIMME. Conclusion: A total of three isobaric quintets have their most exotic members measured by Penning trap mass spectrometry. The GIMME predictions in the T = 2 quintet appear to break down for A = 32 and greater.

20 ≤ A ≤ 38↗

High-Temperature Dissociation of Neopentanol: Shock Tube/Photoionization Mass Spectrometry Studies

Herein, the pyrolysis mechanism of 2,2-dimethylpropan-1-ol (neopentanol) has been investigated at high temperatures (1128–1401K) and high pressures (5 and 15 bar). The experiments were performed in a miniature shock tube coupled to a time-of-flight mass spectrometer. Cations were generated by tunable vacuum ultraviolet photoionization resulting in multidimensional data sets containing mass and photoionization spectra and the time histories of species. At the elevated temperatures and pressures of this work, neopentanol was determined to dissociate primarily by the scission of a C–C bond yielding tert-butyl and hydroxymethyl radicals. These promptly form isobutene and formaldehyde by H-atom elimination. In the structurally similar molecule neopentane, roaming radical reactions have previously been found to be important under conditions close to the present work (1260–1459 K, 1.1 bar). There are two possible roaming radical reactions for neopentanol. However, no experimental evidence for these reactions was found at the elevated pressures in this study, and the dissociation of neopentanol is dominated by bond scission yielding radical products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast dynamics of a near-solid-density layer in an intense femtosecond laser-excited plasma

We report on the picosecond dynamics of a near-solid-density plasma generated by an intense, infrared (λ = 800 nm) femtosecond laser using time-resolved pump-probe Doppler spectrometry. An initial red-shift is observed in the reflected third harmonic (λ = 266 nm) probe pulse, which gets blue-shifted at longer probe-delays. A combination of particle-in-cell and radiation-hydrodynamics modelling is performed to model the pump laser interaction with the solid target. The results are post-processed to predict the Doppler shift. An excellent agreement is found between the results of such modelling and the experiment. The modelling suggests that the initial inward motion of the critical surface observed in the experiment is due to the passage of a shock-wave-like disturbance, launched by the pump interaction, propagating into the target. Furthermore, in order to achieve the best possible fit to the experimental data, it was necessary to incorporate the effects of bulk ion-acceleration resulting from the electrostatic field set up by the expulsion of electrons from the laser envelope. We also present results of time-resolved pump-probe reflectometry, which are corroborated with the spectrometry results using a 1-D reflectivity model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TES Level 1 Algorithms: Interferogram Processing, Geolocation, Radiometric, and Spectral Calibration

The Tropospheric Emission Spectrometer (TES) on the Earth Observing System (EOS) Aura satellite measures the infrared radiance emitted by the Earth's surface and atmosphere using Fourier transform spectrometry. The measured interferograms are converted into geolocated, calibrated radiance spectra by the L1 (Level 1) processing, and are the inputs to L2 (Level 2) retrievals of atmospheric parameters, such as vertical profiles of trace gas abundance. We describe the algorithmic components of TES Level 1 processing, giving examples of the intermediate results and diagnostics that are necessary for creating TES L1 products. An assessment of noise-equivalent spectral radiance levels and current systematic errors is provided. As an initial validation of our spectral radiances, TES data are compared to the Atmospheric Infrared Sounder (AIRS) (on EOS Aqua), after accounting for spectral resolution differences by applying the AIRS spectral response function to the TES spectra. For the TES L1 nadir data products currently available, the agreement with AIRS is 1 K or better.

infrared remote sensing↗

Lipopolysaccharide associated with β-2,6 fructan mediates TLR4-dependent immunomodulatory activity in vitro

Levan, a β-2,6 fructofuranose polymer produced by microbial species, has been reported for its immunomodulatory properties via interaction with toll-like receptor 4 (TLR4) which recognises lipopolysaccharide (LPS). However, the molecular mechanisms underlying these interactions remain elusive. Here, we investigated the immunomodulatory properties of levan using thoroughly-purified and characterised samples from Erwinia herbicola and other sources. E. herbicola levan was purified by gel-permeation chromatography and LPS was removed from the levan following a novel alkali treatment developed in this study. E. herbicola levan was then characterised by gas chromatography–mass spectrometry and NMR. We found that levan containing LPS, but not LPS-depleted levan, induced TLR4-mediated cytokine production by bone marrow-derived dendritic cells and/or activated TLR4 reporter cells. These data indicated that the immunomodulatory properties of the levan toward TLR4-expressing immune cells were mediated by the LPS. This work also demonstrates the importance of LPS removal when assessing the immunomodulatory activity of polysaccharides.

59 BASIC BIOLOGICAL SCIENCES↗

Using Bacteria to Determine Protein Kinase Specificity and Predict Target Substrates

The identification of protein kinase targets remains a significant bottleneck for our understanding of signal transduction in normal and diseased cellular states. Kinases recognize their substrates in part through sequence motifs on substrate proteins, which, to date, have most effectively been elucidated using combinatorial peptide library approaches. Here, we present and demonstrate the ProPeL method for easy and accurate discovery of kinase specificity motifs through the use of native bacterial proteomes that serve as in vivo libraries for thousands of simultaneous phosphorylation reactions. Using recombinant kinases expressed in E. coli followed by mass spectrometry, the approach accurately recapitulated the well established motif preferences of human basophilic (Protein Kinase A) and acidophilic (Casein Kinase II) kinases. These motifs, derived for PKA and CK II using only bacterial sequence data, were then further validated by utilizing them in conjunction with the scan-x software program to computationally predict known human phosphorylation sites with high confidence.

59 BASIC BIOLOGICAL SCIENCES↗

Calcium kinetics with microgram stable isotope doses and saliva sampling

Studies of calcium kinetics require administration of tracer doses of calcium and subsequent repeated sampling of biological fluids. This study was designed to develop techniques that would allow estimation of calcium kinetics by using small (micrograms) doses of isotopes instead of the more common large (mg) doses to minimize tracer perturbation of the system and reduce cost, and to explore the use of saliva sampling as an alternative to blood sampling. Subjects received an oral dose (133 micrograms) of 43Ca and an i.v. dose (7.7 micrograms) of 46Ca. Isotopic enrichment in blood, urine, saliva and feces was well above thermal ionization mass spectrometry measurement precision up to 170 h after dosing. Fractional calcium absorptions determined from isotopic ratios in blood, urine and saliva were similar. Compartmental modeling revealed that kinetic parameters determined from serum or saliva data were similar, decreasing the necessity for blood samples. It is concluded from these results that calcium kinetics can be assessed with micrograms doses of stable isotopes, thereby reducing tracer costs and with saliva samples, thereby reducing the amount of blood needed.

Clinical Trial↗

Structural Analysis of a Highly Glycosylated and Unliganded gp120-Based Antigen Using Mass Spectrometry

Structural characterization of the HIV-1 envelope protein gp120 is very important for providing an understanding of the protein's immunogenicity and its binding to cell receptors. So far, the crystallographic structure of gp120 with an intact V3 loop (in the absence of a CD4 coreceptor or antibody) has not been determined. The third variable region (V3) of the gp120 is immunodominant and contains glycosylation signatures that are essential for coreceptor binding and entry of the virus into T-cells. In this study, we characterized the structure of the outer domain of gp120 with an intact V3 loop (gp120-OD8) purified from Drosophila S2 cells utilizing mass spectrometry-based approaches. We mapped the glycosylation sites and calculated the glycosylation occupancy of gp120-OD8; 11 sites from 15 glycosylation motifs were determined as having high-mannose or hybrid glycosylation structures. The specific glycan moieties of nine glycosylation sites from eight unique glycopeptides were determined by a combination of ECD and CID MS approaches. Hydroxyl radical-mediated protein footprinting coupled with mass spectrometry analysis was employed to provide detailed information about protein structure of gp120-OD8 by directly identifying accessible and hydroxyl radical-reactive side chain residues. Comparison of gp120-OD8 experimental footprinting data with a homology model derived from the ligated CD4-gp120-OD8 crystal structure revealed a flexible V3 loop structure in which the V3 tip may provide contacts with the rest of the protein while residues in the V3 base remain solvent accessible. In addition, the data illustrate interactions between specific sugar moieties and amino acid side chains potentially important to the gp120-OD8 structure.

59 BASIC BIOLOGICAL SCIENCES↗

Extending the frontiers of mass spectrometric instrumentation and methods

The focus of this dissertation is two-fold: developing novel analysis methods using mass spectrometry and the implementation and characterization of a novel ion mobility mass spectrometry instrumentation. The novel mass spectrometry combines ion trap for ion/ion reactions coupled to an ion mobility cell. The long term goal of this instrumentation is to use ion/ion reactions to probe the structure of gas phase biomolecule ions. The three ion source - ion trap - ion mobility - qTOF mass spectrometer (IT - IM - TOF MS) instrument is described. The analysis of the degradation products in coal (Chapter 2) and the imaging plant metabolites (Appendix III) fall under the methods development category. These projects use existing commercial instrumentation (JEOL AccuTOF MS and Thermo Finnigan LCQ IT, respectively) for the mass analysis of the degraded coal products and the plant metabolites, respectively. The coal degradation paper discusses the use of the DART ion source for fast and easy sample analysis. The sample preparation consisted of a simple 50 fold dilution of the soluble coal products in water and placing the liquid in front of the heated gas stream. This is the first time the DART ion source has been used for analysis of coal. Steven Raders under the guidance of John Verkade came up with the coal degradation projects. Raders performed the coal degradation reactions, worked up the products, and sent them to me. Gregg Schieffer developed the method and wrote the paper demonstrating the use of the DART ion source for the fast and easy sample analysis. The plant metabolite imaging project extends the use of colloidal graphite as a sample coating for atmospheric pressure LDI. DC Perdian and I closely worked together to make this project work. Perdian focused on building the LDI setup whereas Schieffer focused on the MSn analysis of the metabolites. Both Perdian and I took the data featured in the paper. Perdian was the primary writer of the paper and used it as a chapter in his dissertation. Perdian and Schieffer worked together to address the revisions and publish it in Rapid Communications in Mass Spectrometry Journal.

01 COAL, LIGNITE, AND PEAT↗

Molecular Communication over Gas Stream Channels using Portable Mass Spectrometry

The synthetic generation/coding and transmission of olfactory information over a gas stream or an odor network is a new and unexplored field. Application areas vary from the entertainment or advertisement industry to security and telemedicine. However, current technological limitations frustrate the accurate reproduction of decoded and transmitted olfactory data. This study describes the development, testing, and characterization of a novel odor emitter (OE) that is used to investigate the generation-encoding of gaseous standards with odorous characteristics with a regulatable way, for scent transmission purposes. The calibration and the responses of a developed OE were examined using a portable quadrupole mass spectrometer (MS). Experiments were undertaken for a range of volatile organic compounds (VOCs) at different temperatures and flow rates. Individual compounds and mixtures were tested to investigate periodic and dynamic transmission characteristics within two different size tubular containers for distances up to 3 m. Olfactory information transmission is demonstrated using MS as the main molecular sensor for odor detection and monitoring and for the first time spatial encryption of olfactory information is shown. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A deep learning-guided automated workflow in LipidOz for detailed characterization of fungal fatty acid unsaturation by ozonolysis

Understanding fungal lipid biology and metabolism is critical for antifungal target discovery as lipids play central roles in cellular processes. Nuances in lipid structural differences can significantly impact their functions, making it necessary to characterize lipids in detail to enable and understanding of their roles in these complex systems. In particular, lipid double bond (DB) locations are an important component of lipid structure that can only be determined using a few specialized analytical techniques. Ozone-induced dissociation mass spectrometry (OzID-MS) is one such technique that uses ozone to break lipid DBs, producing pairs of characteristic fragments that allow the determination of DB positions. In this work we apply OzID-MS and LipidOz software to analyze the complex lipids of Saccharomyces cerevisiae yeast strains transfected with different fatty acid desaturases from Histoplasma capsulatum to determine the specific unsaturated lipids produce. The automated data analysis in LipidOz made the determination of DB positions from this large dataset more practical, but manual verification for all targets was still time-consuming. The DL model reduces manual involvement in data analysis, but since it was trained using mammalian lipid extracts, the prediction accuracy on yeast-derived data was reduced. We addressed both shortcomings by retraining the DL model to act as a pre-filter to prioritize targets for automated analysis, providing confident manually verified results but requiring less computational time and manual effort. Our workflow resulted in the determination of novel DB positions and enzymatic specificity.

mass spectrometry, deep learning, Lipidomics, doub↗

Distributions of Ag, Bi, and Sb as Minor Elements between Iron-Silicate Slag and Copper in Equilibrium with Tridymite in the Cu-Fe-O-Si System at T = 1250 °C and 1300 °C (1523 K and 1573 K)

New experimental data on the distributions of silver (Ag), bismuth (Bi), and antimony (Sb) between liquid iron-silicate slag and liquid copper metal in equilibrium with tridymite in the Cu-Fe-O-Si system at T = 1250 °C and 1300 °C (1523 K and 1573 K) have been obtained. The experimental methodology involved high-temperature equilibration, rapid quenching of the equilibrated phases, followed by direct measurement of the equilibrium phases with electron probe X-ray microanalysis (EPMA) for measurement of major element concentrations and laser ablation inductively coupled plasma mass spectrometry (LAICPMS) for the measurement of minor element concentrations. The 4-point test approach was employed to confirm the achievement of chemical equilibrium in the current study. Open-system equilibration on quartz substrates in controlled gas atmospheres (CO/CO{sub 2}/Ar) and closed-system equilibration in sealed quartz ampoules were used. The new experimental data resolve significant discrepancies found in previous studies and can be used as input for the development of thermodynamic databases for copper-making processes.

36 MATERIALS SCIENCE↗