Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spatial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Catalysts in Coronas: A Surface Spatial Confinement Strategy for High-Performance Catalysts in Methane Dry Reforming

One of the grand challenges in industrial catalytic processes is the inevitable sintering and aggregation of conventional supported catalysts to large particles, leading to the decrease of activity and even deactivation with time. Herein, a surface spatial confinement strategy was employed to design high-performing catalysts for the dry reforming of methane (DRM). Specifically, active nickel (Ni) nanoparticles (NPs) were confined on the surface of a dendritic mesoporous silica (DMS) in the form of the “catalysts in coronas”. The Ni/DMS catalyst exhibited a high catalytic performance close to its equilibrium conversion (76% conversion for CH4 at 700 °C). More importantly, the prepared catalyst remained stable after 145 h time-on-stream at 700 °C without noticeable carbon deposition. This sintering and coking resistance was found to arise from the surface spatial confinement effect in which the three-dimensional dendritic layers in the corona posted a steric barrier against migration and aggregation of Ni NPs and size of Ni NPs was controlled below 5 nm, hence against sintering and coking. Meanwhile, the mesoporous feature of the layered wall facilitated mass transport of reactants to Ni species and further boosted catalysis. This strategy should be broadly applicable to a range of metal- and metal oxide-supported catalysts in high-temperature heterogeneous reactions, such as DRM, water gas shift reaction, and vehicle emission control related reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impacts of Aerosol Dry Deposition on Black Carbon Spatial Distributions and Radiative Effects in the Community Atmosphere Model CAM5

Dry deposition is a vital process affecting the lifetime and spatial distributions of atmospheric aerosols. Black carbon (BC) plays an important role in the Earth’s climate. To explore the sensitivity of modeled BC spatial distributions to particle dry deposition treatments, the scheme of Petroff & Zhang (2010) (PZ10) is implemented into the Community Atmospheric Model version 5 (CAM5), and model simulations using PZ10 are compared with the one using the default scheme of Zhang et al. (2001) (Z01). The PZ10 scheme suggests much lower dry deposition velocities than Z01 for fine particles in Aitken, primary carbon, and accumulation modes, resulting in 73.0% lower of global mean BC dry deposition fluxes and 23.2% higher of global mean BC column burdens. CAM5 with PZ10 increases modeled BC concentrations at all altitudes and latitudes compared to Z01, which improves the agreement with observations of BC profiles in the lower troposphere in the Arctic. It also helps the simulation of surface BC concentrations in high-latitudes remote regions and its seasonality in the Arctic. Yet, PZ10 slightly exacerbates the overestimation of modeled BC concentrations in the middle and upper troposphere, which might be due to model uncertainties in other aerosol physical and chemical processes. The global annual mean radiative effects due to aerosol-radiation interactions (REari) and aerosol-cloud interactions (REaci) of BC from the CAM5 experiment using Z01 are 0.61±0.007 and -0.11±0.02 W m -2 , respectively, compared to slightly larger REari (0.75±0.01 W m -2 ) and REaci (-0.14±0.02 W m -2 ) from CAM5 using PZ10.

54 ENVIRONMENTAL SCIENCES↗

Influence of heat and particle fluxes nonlocality on spatial distribution of plasma density in two-chamber inductively coupled plasma sources

This study presents 2D simulations of the two-chamber inductively coupled plasma source where power is supplied in the small discharge chamber and extends by electron thermal conductivity mechanism to the big diffusion chamber. Depending on pressure, two main scenarios of plasma density and its spatial distribution behavior were identified. One case is characterized by the localization of plasma in the small driver chamber where power is deposed. Another case describes when the diffusion chamber becomes the main source of plasma with maximum of the electron density. The differences in spatial distribution are caused by local or non-local behavior of electron energy transport in the discharge volume due to different characteristic scale of heat transfer with electronic conductivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional-spatial distribution measurement of electron temperature and plasma density in low temperature plasmas

A real-time measurement method for two-dimensional (2D) spatial distribution of the electron temperature and plasma density was developed. The method is based on the floating harmonic method and the real time measurement is achieved with little plasma perturbation. 2D arrays of the sensors on a 300 mm diameter wafer-shaped printed circuit board with a high speed multiplexer circuit were used. Experiments were performed in an inductive discharge under various external conditions, such as powers, gas pressures, and different gas mixing ratios. The results are consistent with theoretical prediction. Our method can measure the 2D spatial distribution of plasma parameters on a wafer-level in real-time. This method can be applied to plasma diagnostics to improve the plasma uniformity of plasma reactors for plasma processing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Taheri-Saramad x-ray detector (TSXD): A novel high spatial resolution x-ray imager based on ZnO nano scintillator wires in polycarbonate membrane

A novel x-ray imager based on ZnO nanowires is designed and fabricated. The proposed architecture is based on scintillation properties of ZnO nanostructures in a polycarbonate track-etched membrane. Because of higher refractive index of ZnO nanowire compared to the membrane, the nanowire acts as an optical fiber that prevents the generated optical photons to spread inside the detector. This effect improves the spatial resolution of the imager. The detection quantum efficiency and spatial resolution of the fabricated imager are 11% and <6.8 μm, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial organization and correlation properties quantify structural changes on mesoscale of parenchymatous plant tissue

The study of plant tissue parenchyma's intercellular air spaces contributes to the understanding of anatomy and physiology. This is challenging due to difficulty in making direct measurements of the pore space and the complex mosaic of parenchymatous tissue. The architectural complexity of pore space has shown that single geometrical measurements are not sufficient for characterization. The inhomogeneity of distribution depends not only on the percentage content of phase, but also on how the phase fills the space. The lacunarity morphometric, as multiscale measure, provides information about the distribution of gaps that correspond to degree of spatial organization in parenchyma. Additionally, modern theories have suggested strategies, where the focus has shifted from the study of averages and histograms to the study of patterns in data fluctuations. Detrended fluctuation analysis provides information on the correlation properties of the parenchyma at different spatial scales. The aim is to quantify (with the aid of the aforementioned metrics), the mesostructural changes—that occur from one cycle of freezing and thawing—in the void phase of pome fruit parenchymatous tissue, acquired with X-ray microcomputed tomography. Complex systems methods provide numerical indices and detailed insights regarding the freezing-induced modifications upon the arrangement of cells and voids. These structural changes have the potential to lead to physiological disorders. The work can further stimulate interest for the analysis of internal plant tissue structures coupled with other physico-chemical processes or phenomena.

60 APPLIED LIFE SCIENCES↗

Localized parallel parametric generation of spin waves in a Ni{sub 81}Fe{sub 19} waveguide by spatial variation of the pumping field

We present the experimental observation of localized parallel parametric generation of spin waves in a transversally in-plane magnetized Ni{sub 81}Fe{sub 19} magnonic waveguide. The localization is realized by combining the threshold character of parametric generation with a spatially confined enhancement of the amplifying microwave field. The latter is achieved by modulating the width of the microstrip transmission line which is used to provide the pumping field. By employing microfocussed Brillouin light scattering spectroscopy, we analyze the spatial distribution of the generated spin waves and compare it with numerical calculations of the field distribution along the Ni{sub 81}Fe{sub 19} waveguide. This provides a local spin-wave excitation in transversally in-plane magnetized waveguides for a wide wave-vector range which is not restricted by the size of the generation area.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of spatial and temporal behavior of H{sub α} emission from Aditya tokamak using a diagnostic based on a photomultiplier tube array

A photo multiplier tube (PMT) array based spectroscopic diagnostic with fast time response of 10 μs and spatial resolution ∼3 cm has been developed and installed on Aditya tokamak to study the spatial and temporal behavior of H{sub α} emissions from typical discharges. Collimated light has been collected from the plasma along 16 lines of sight passing through entire plasma poloidal cross section of Aditya and detected by two 8 channels PMT arrays after selecting H{sub α} emission using interference filter. The studies are carried out during plasma formation phase of Aditya by changing vertical field and its delay with respect to loop voltage. It is observed that plasma initiated in the high field side in typical discharges of Aditya. The plasma formation position is matched with null field location estimated through simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Amorphous indium-tin-zinc oxide films deposited by magnetron sputtering with various reactive gases: Spatial distribution of thin film transistor performance

This work presents the spatial distribution of electrical characteristics of amorphous indium-tin-zinc oxide film (a-ITZO), and how they depend on the magnetron sputtering conditions using O{sub 2}, H{sub 2}O, and N{sub 2}O as the reactive gases. Experimental results show that the electrical properties of the N{sub 2}O incorporated a-ITZO film has a weak dependence on the deposition location, which cannot be explained by the bombardment effect of high energy particles, and may be attributed to the difference in the spatial distribution of both the amount and the activity of the reactive gas reaching the substrate surface. The measurement for the performance of a-ITZO thin film transistor (TFT) also suggests that the electrical performance and device uniformity of a-ITZO TFTs can be improved significantly by the N{sub 2}O introduction into the deposition process, where the field mobility reach to 30.8 cm{sup 2} V{sup –1} s{sup –1}, which is approximately two times higher than that of the amorphous indium-gallium-zinc oxide TFT.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrahigh-spatial-resolution chemical and magnetic imaging by laser-based photoemission electron microscopy

We report the first experiments carried out on a new chemical and magnetic imaging system, which combines the high spatial resolution of a photoemission electron microscope (PEEM) with a continuous-wave deep-ultraviolet laser. Threshold photoemission is sensitive to the chemical and magnetic structures of the surface of materials. The spatial resolution of PEEM is limited by space charging when using pulsed photon sources as well as aberrations in the electron optics. We show that the use of a continuous-wave laser enabled us to overcome such a limit by suppressing the space-charge effect, allowing us to obtain a resolution of approximately 2.6 nm. With this system, we demonstrated the imaging of surface reconstruction domains on Si(001) by linear dichroism with normal incidence of the laser beam. We also succeeded in magnetic imaging of thin films with the use of magnetic circular dichroism near the Fermi level. The unique features of the ultraviolet laser will give us fast switching of the incident angles and polarizations of the photon source, which will be useful for the characterization of antiferromagnetic materials as well as ferromagnetic materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial distribution of the plasma parameters in the RF negative ion source prototype for fusion

A numerical model, based on the fluid plasma theory, has been used for description of the spatial distribution of the plasma parameters (electron density and temperature, plasma potential as well as densities of the three types of positive hydrogen ions) in the IPP prototype RF negative hydrogen ion source. The model covers the driver and the expansion plasma region of the source with their actual size and accounts for the presence of the magnetic filter field with its actual value and location as well as for the bias potential applied to the plasma grid. The obtained results show that without a magnetic filter the two 2D geometries considered, respectively, with an axial symmetry and a planar one, represent accurately the complex 3D structure of the source. The 2D model with a planar symmetry (where the E×B and diamagnetic drifts could be involved in the description) has been used for analysis of the influence, via the charged-particle and electron-energy fluxes, of the magnetic filter and of the bias potential on the spatial structure of the plasma parameters in the source. Benchmarking of results from the code to experimental data shows that the model reproduces the general trend in the axial behavior of the plasma parameters in the source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial resolution of imaging plate with flash X-rays and its utilization for radiography

A flash X-ray source developed using pulsed electron accelerator with electron energy range of 400keV to 1030keV and a field emission cathode is characterized using X-ray imaging plates. Spatial resolution of the imaging system is measured using edge spread function fitted to data obtained from radiograph of Pb step wedge. A spatial resolution of 150±6 µm is obtained. The X-ray beam size is controlled by the anode-cathode configuration. Optimum source size of ∼13±2 mm diameter covering an area with intensity of ∼27000 PSL/mm{sup 2} is obtained on the imaging plate kept at a distance of ∼200 mm from the tip of the anode. It is used for recording radiographs of objects like satellite cable cutter, aero-engine turbine blade and variety of pyro-devices used in aerospace industry.

07 ISOTOPE AND RADIATION SOURCES↗

Quantitative x-ray magnetic circular dichroism mapping with high spatial resolution full-field magnetic transmission soft x-ray spectro-microscopy

The spectroscopic analysis of X-ray magnetic circular dichroism (XMCD), which serves as strong and element-specific magnetic contrast in full-field magnetic transmission soft x-ray microscopy, is shown to provide information on the local distribution of spin (S) and orbital (L) magnetic moments down to a spatial resolution of 25 nm limited by the x-ray optics used in the x-ray microscope. The spatially resolved L/S ratio observed in a multilayered (Co 0.3 nm/Pt 0.5 nm) × 30 thin film exhibiting a strong perpendicular magnetic anisotropy decreases significantly in the vicinity of domain walls, indicating a non-uniform spin configuration in the vertical profile of a domain wall across the thin film. Quantitative XMCD mapping with x-ray spectro-microscopy will become an important characterization tool for systems with topological or engineered magnetization inhomogeneities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of finite spatial coherence on ptychographic reconstruction

X-ray ptychography is an ultrahigh-resolution scanning coherent diffractive imaging technique, allowing quantitative measurements of extended samples and a simultaneous reconstruction of the illuminating wavefront. Recent development of the mixed-state reconstruction algorithm has triggered a certain interest in utilizing partially coherent X-ray sources for ptychography. Here, we study how finite spatial coherence influences the reconstructed image of a test structure. Our work shows that use of a highly coherent illumination provides images with better spatial resolution and fewer artefacts than the approach with partial coherence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Large-scale proton radiography with micrometer spatial resolution using femtosecond petawatt laser system

An image of dragonfly with many details is obtained by the fundamental property of the high-energy proton source on a femtosecond petawatt laser system. Equal imaging of the dragonfly and high spatial resolution on the micrometer scale are simultaneously obtained. The head, wing, leg, tail, and even the internal tissue structures are clearly mapped in detail by the proton beam. Experiments show that image blurring caused by multiple Coulomb scattering can be reduced to a certain extent and the spatial resolution can be increased by attaching the dragonfly to the RCFs, which is consistent with theoretical assumptions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Facile and high spatial resolution ratio-metric luminescence thermal mapping in microfluidics by near infrared excited upconversion nanoparticles

A local area temperature monitor is important for precise control of chemical and biological processes in microfluidics. In this work, we developed a facile method to realize micron spatial resolution of temperature mapping in a microfluidic channel quickly and cost effectively. Based on the temperature dependent fluorescence emission of NaYF{sub 4}:Yb{sup 3+}, Er{sup 3+} upconversion nanoparticles (UCNPs) under near-infrared irradiation, ratio-metric imaging of UCNPs doped polydimethylsiloxane can map detailed temperature distribution in the channel. Unlike some reported strategies that utilize temperature sensitive organic dye (such as Rhodamine) to achieve thermal sensing, our method is highly chemically inert and physically stable without any performance degradation in long term operation. Moreover, this method can be easily scaled up or down, since the spatial and temperature resolution is determined by an optical imaging system. Our method supplied a simple and efficient solution for temperature mapping on a heterogeneous surface where usage of an infrared thermal camera was limited.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial distribution of transferred charges across the heterointerface between perovskite transition metal oxides LaNiO{sub 3} and LaMnO{sub 3}

To investigate the interfacial charge-transfer phenomena between perovskite transition metal oxides LaNiO{sub 3} (LNO) and LaMnO{sub 3} (LMO), we have performed in situ x-ray absorption spectroscopy (XAS) measurements on LNO/LMO multilayers. The Ni-L{sub 2,3} and Mn-L{sub 2,3} XAS spectra clearly show the occurrence of electron transfer from Mn to Ni ions in the interface region. Detailed analysis of the thickness dependence of these XAS spectra has revealed that the spatial distribution of the transferred charges across the interface is significantly different between the two constituent layers. The observed spatial distribution is presumably described by the charge spreading model that treats the transfer integral between neighboring transition metal ions and the Coulomb interaction, rather than the Thomas–Fermi screening model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pilot tone as a key to improving the spatial resolution of eBPMs

At Elettra, the Italian synchrotron light source, an internal project has been started to develop an electron beam position monitor capable of achieving sub-micron resolution with a self-compensation feature. In order to fulfil these requirements, a novel RF front end has been designed. A high isolation coupler combines the input signals with a known pilot tone which is generated by the readout system. This allows the parameters of the four channels to be continuously calibrated, by compensating the different responses of each channel. A similar technique is already known, but for the first time experimental results have shown the improvement in resolution due to this method. The RF chain was coupled with a 4-channel digitizer based on 160 MHz, 16 bits ADCs and an Altera Stratix FPGA. At first, no additional processing was done in the FPGA, collecting only the raw data from the ADCs; the position was calculated through the FFT of each signal. A simulation was also performed to verify the analytic relation between spatial resolution and signal-to-noise ratio; this was very useful to better understand the behaviour of the system with different sources of noise (aperture jitter, thermal noise, etc.). The experimental data were compared with the simulation, showing indeed a perfect agreement with the latter and confirming the capability of the system to reach sub-micrometric accuracy. Therefore, the use of the pilot tone greatly improves the quality of the system, correcting the drifts and increasing the spatial resolution by a factor of 4 in a time window of 24 hours.

43 PARTICLE ACCELERATORS↗