Tangential soft-x ray imaging for three-dimensional structural studies in a reversed field pinch

Tangential soft-x ray (SXR) imaging diagnostic has been developed and three-dimensional (3D) structure of the internal magnetic surface has been deduced by comparing the experimental and calculated two-dimensional SXR images in a reversed field pinch. The SXR imaging system, consisting of a MCP, a fluorescent plate, and an intensified charge coupled device camera, has been installed in REversed field pinch of Low-Aspect-ratio eXperiment (RELAX) machine. Major characteristics of an experimental SXR image could be reproduced by numerical calculations of the image using a single island model, suggesting a helical hot core in RELAX. The SXR imaging system could be useful for 3D structural studies when tangential and vertical simultaneous imaging systems would be installed, with appropriate numerical modeling of 3D structure of the magnetic surfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype high resolution multienergy soft x-ray array for NSTX

A novel diagnostic design seeks to enhance the capability of multienergy soft x-ray (SXR) detection by using an image intensifier to amplify the signals from a larger set of filtered x-ray profiles. The increased number of profiles and simplified detection system provides a compact diagnostic device for measuring T{sub e} in addition to contributions from density and impurities. A single-energy prototype system has been implemented on NSTX, comprised of a filtered x-ray pinhole camera, which converts the x-rays to visible light using a CsI:Tl phosphor. SXR profiles have been measured in high performance plasmas at frame rates of up to 10 kHz, and comparisons to the toroidally displaced tangential multi-energy SXR have been made.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Developments in Femtosecond Soft X-ray Spectroscopy

Recent instrumentation developments in X-ray spectroscopy for ultra-fast time-resolved measurements with soft X-rays done in HZB Berlin during the last years are described. The significant performance improvements achieved this way are based on Fresnel diffraction from structures being fabricated on a surface of a total externally reflecting mirror. The first type of this spectrometer, an off-axis reflection zone plate, has been implemented at the BESSY Femtoslicing setup and shows on the order of 20 times higher flux in the focal plane compared to the classical grating monochromator beamline. It has proven to serve very precise experiments with a time resolution down to 100 fs on magnetic materials after optical laser pulse excitation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A new soft x-ray autocorrelator--direct evaluation of the temporal properties of FEL pulses at 24 nm

To provide two jitter-free soft x-ray pulses for femtosecond x-ray pump and probe experiments a split and delay unit (autocorrelator) has been constructed for the VUV-FEL in Hamburg (FLASH). Here we report experiments applying this autocorrelator to examine the average temporal properties of FEL pulses delivered from FLASH at 24 nm (51.8 eV). In a linear autocorrelation experiment the spatio-temporal coherence properties are measured for both the first and the third harmonic of the FEL pulses. Furthermore, we report on the first evaluation of the pulse length from the time-resolved observation of doubly charged helium ions produced by direct two-photon double ionization at 24 nm. In summary the determination of the longitudinal pulse parameter of FLASH at 24 nm to 6 fs and 29{+-}5 fs for the coherence time and the pulse length (FWHM) respectively proofs the autocorrelator as a valuable tool for time resolved two pulse X-ray experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Current Performance of the Wide Range (90-2500 eV) Soft X-ray Beamline at the Australian Synchrotron

The Soft X-ray beamline at the Australian synchrotron has been constructed around a collimated light Plane Grating Monochromator taking light from an Elliptically Polarized Undulator (EPU). The beamline covers a wide photon energy range between 90 to 2500 eV, using two gratings of 250 l/mm and 1200 l/mm. At present the output from the monochromator is directed into one branchline with a dedicated UHV endstation. The measured performance of the beamline in flux and resolution is shown to be very close to that of theoretical calculations.

43 PARTICLE ACCELERATORS↗

Preliminary Commissioning and Performance of the Soft X-ray Micro-characterization Beamline at the Canadian Light Source

The Soft X-ray Micro-characterization Beamline (SXRMB) is a medium energy, bending magnet based beamline, designed to cover an energy range of 1.7-10 keV using two sets of crystals--InSb(111) and Si(111). The design goal is to deliver a flux of 2x10{sup 11} photons sec{sup -1}/100 mA with a resolution up to 10,000 for X-ray Absorption Spectroscopy. A KB mirror stage is designed to provide microprobe capability, with a spot size of 10x10 {mu}m{sup 2} and a flux of >10{sup 9} at the microprobe station. The beamline has been in the commissioning phase since 2008, and access to the X-ray absorption endstation is now open to general users. The optical commissioning and performance of the beamline is presented with some early experimental results.

43 PARTICLE ACCELERATORS↗

Optical Design of VLS-PGM Soft X-Ray Beamline on Indus-2

The optical design of a soft x-ray beamline on the bending magnet of Indus-2 synchrotron source is presented. A Varied Line Spacing Plane Grating Monochromator (VLS-PGM) was adopted with Hettrick type optics. The VLS-PGM consists of a spherical mirror and three interchangeable gratings of line densities 1200 l/mm, 400 l/mm and 150 l/mm to efficiently cover the energy region 50-1500 eV. The VLS groove parameters were obtained by minimizing defocus aberration, coma and spherical aberration. The overall performance of the beamline was estimated by detailed raytracing calculations. The beamline design, results of the raytracing calculations and the expected performances are presented.

43 PARTICLE ACCELERATORS↗

New Soft X-ray Beamline (BL10) at the SAGA Light Source

A new soft X-ray beamline (BL10) at the SAGA Light Source (SAGA-LS) was constructed at the end of 2008. Commissioning of this new beamline started at the beginning of 2009. Synchrotron radiation from a variably polarizing undulator (APPLE-II) can be used in this beamline. The obtained light is monochromatized by a varied-line-spacing plane grating monochromator with the variable included angle mechanism. Its designed resolving power and photon flux are 3,000-10,000 and 10{sup 12}-10{sup 9} photons/s at 300 mA, respectively. The performance test results were generally satisfactory. An overview of the optical design of the beamline and the current status of commissioning are reported.

43 PARTICLE ACCELERATORS↗

The Soft X-ray Polarimeter and Applications at BSRF

A novel compact polarimeter for the use in soft x-ray region having high-precision eight-axis automatically driven and two-axis manually driven equipped with multilayer polarizers was developed at the Beijing Synchrotron Radiation Facility (BSRF). The polarimeter was designed to utilize reflection and transmission geometry. Four operational modes have been designed and carried out with the polarimeter. Some experiments have been performed by using this polarimeter with various modes.

43 PARTICLE ACCELERATORS↗

A Soft X-ray Spectrometer using a Highly Dispersive Multilayer Grating

There is a need for higher resolution spectrometers as a tool for inelastic x-ray scattering. Currently, resolving power around R = 10,000 is advertised. Measured RIXS spectra are often limited by this instrumental resolution and higher resolution spectrometers using conventional gratings would be prohibitively large. We are engaged in a development program to build blazed multilayer grating structures for diffracting soft x-rays in high order. This leads to spectrometers with dispersion much higher than is possible using metal coated-gratings. The higher dispersion then provides higher resolution and the multilayer gratings are capable of operating away from grazing incidence as required. A spectrometer design is presented with a total length 3.8 m and capable of 10{sup 5} resolving power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface Slope Metrology on Deformable Soft X-ray Mirrors

We report on the current state of surface slope metrology on deformable mirrors for soft x-rays at the Advanced Light Source (ALS). While we are developing techniques for in situ at-wavelength tuning, we are refining methods of ex situ visible-light optical metrology to achieve sub-100-nrad accuracy. This paper reports on laboratory studies, measurements and tuning of a deformable test-KB mirror prior to its use. The test mirror was bent to a much different optical configuration than its original design, achieving a 0.38 micro-radian residual slope error. Modeling shows that in some cases, by including the image conjugate distance as an additional free parameter in the alignment, along with the two force couples, fourth-order tangential shape errors (the so-called bird shape) can be reduced or eliminated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Two-dimensional Detector for High Resolution Soft X-ray Imaging

A new two-dimensional (2D) detector for detecting soft X-ray (SX) images was developed. The detector has a scintillator plate to convert a SX image into a visible (VI) one, and a relay optics to magnify and detect the converted VI image. In advance of the fabrication of the detector, quantum efficiencies of scintillators were investigated. As a result, a Ce:LYSO single crystal on which Zr thin film was deposited was used as an image conversion plate. The spatial resolution of fabricated detector is 3.0 {mu}m, and the wavelength range which the detector has sensitivity is 30-6 nm region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft x-ray continuum radiation transmitted through metallic filters: An analytical approach to fast electron temperature measurements

A new set of analytic formulas describes the transmission of soft x-ray continuum radiation through a metallic foil for its application to fast electron temperature measurements in fusion plasmas. This novel approach shows good agreement with numerical calculations over a wide range of plasma temperatures in contrast with the solutions obtained when using a transmission approximated by a single-Heaviside function [S. von Goeler et al., Rev. Sci. Instrum. 70, 599 (1999)]. The new analytic formulas can improve the interpretation of the experimental results and thus contribute in obtaining fast temperature measurements in between intermittent Thomson scattering data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new double-foil soft x-ray array to measure T{sub e} on the MST reversed field pinch

A soft x-ray (SXR) diagnostic to measure electron temperature on the Madison Symmetric Torus using two complementary methods is presented. Both methods are based on the double-foil technique, which calculates electron temperature via the ratio of SXR bremsstrahlung emission from the plasma in two different energy ranges. The tomographic emissivity method applies the double-foil technique to a tomographic reconstruction of SXR emissivity, creating a two-dimensional map of temperature throughout the plasma. In contrast, the direct brightness method applies the double-foil technique directly to the measured brightness and generates vertical and horizontal radial profiles. Extensive modeling demonstrates advantages and limitations in both techniques. For example, although the emissivity technique provides a two-dimensional mapping of temperature, its reliance on multiple tomographic inversions introduces some artifacts into the results. On the other hand, the more direct brightness technique avoids these artifacts but is only able to provide a radial profile of electron temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-performance soft x-ray spectromicroscopy beamline at SSRF

The Shanghai Synchrotron Radiation Facility (SSRF) is the first third-generation synchrotron facility in China and operated at an electron energy of 3.5 GeV. One of the seven beamlines in the first construction phase is devoted to soft x-ray spectromicroscopy and is equipped with an elliptically polarized undulator light source, a plane grating monochromator, and a scanning transmission x-ray microscope end station. Initial results reveal the high performance of this beamline, with an energy resolving power estimated to be over 10 000 at the argon L-edge and a spatial resolution better than 30 nm.

43 PARTICLE ACCELERATORS↗

Characterization of a 2D soft x-ray tomography camera with discrimination in energy bands

A gas detector with a 2D pixel readout is proposed for a future soft x-ray (SXR) tomography with discrimination in energy bands separately per pixel. The detector has three gas electron multiplier foils for the electron amplification and it offers the advantage, compared with the single stage, to be less sensitive to neutrons and gammas. The energy resolution and the detection efficiency of the detector have been accurately studied in the laboratory with continuous SXR spectra produced by an electronic tube and line emissions produced by fluorescence (K, Fe, and Mo) in the range of 3-17 keV. The front-end electronics, working in photon counting mode with a selectable threshold for pulse discrimination, is optimized for high rates. The distribution of the pulse amplitude has been indirectly derived by means of scans of the threshold. Scans in detector gain have also been performed to assess the capability of selecting different energy ranges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoscale surface modifications and formation of conical structures at aluminum surface induced by single shot exposure of soft x-ray laser pulse

We irradiated the soft x-ray laser (SXRL) pulses having a wavelength of 13.9 nm, a duration time of 7 ps, and fluences of up to 27 mJ/cm{sup 2} to aluminum (Al) surface. After the irradiation process, the modified surface was observed with the visible microscope, the scanning electron microscope, and the atomic force microscope. The surface modifications caused by the SXRL pulses were clearly seen, and it was found that the conical structures having about 70-150 nm in diameters were formed under a single pulse shot. The conical structures were formed in the features with the average depth of about 40 nm, and this value was in accordance with the attenuation length of the SXRL beam for Al. However, those conical structures were deconstructed under the multiple pulse shots exposure. Thermomechanical modeling of SXRL laser interaction with Al surface, which explains nanostructure surface modification, was provided.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synchrotron x-ray photoemission study of soft x-ray processed ultrathin glycine-water ice films

Ultrathin glycine-water ice films have been prepared in ultrahigh vacuum by condensation of H{sub 2}O and glycine at 90 K on single crystalline alumina surfaces and processed by soft x-ray (610 eV) exposure for up to 60 min. The physicochemical changes in the films were monitored using synchrotron x-ray photoemission spectroscopy. Two films with different amounts of H{sub 2}O have been considered in order to evaluate the influence of the water ice content on the radiation-induced effects. The analysis of C1s, N1s, and O1s spectral regions together with the changes in the valence band spectra indicates that amino acid degradation occurs fast mainly via decarboxylation and deamination of pristine molecules. Enrichment of the x-ray exposed surfaces with fragments with carbon atoms without strong electronegative substituents (C-C and C-H) is documented as well. In the thinner glycine-water ice film (six layers of glycine + six layers of water) the 3D ice suffers strongly from the x-rays and is largely removed from the sample. The rate of photodecomposition of glycine in this film is about 30% higher than for glycine in the thicker film (6 layers of glycine + 60 layers of water). The photoemission results suggest that the destruction of amino acid molecules is caused by the direct interaction with the radiation and that no chemical attack of glycine by the species released by water radiolysis is detected.