Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Gyro and accelerometer failure detection and identification in redundant sensor systems

Algorithms for failure detection and identification for redundant noncolinear arrays of single degree of freedom gyros and accelerometers are described. These algorithms are optimum in the sense that detection occurs as soon as it is no longer possible to account for the instrument outputs as the outputs of good instruments operating within their noise tolerances, and identification occurs as soon as it is true that only a particular instrument failure could account for the actual instrument outputs within the noise tolerance of good instruments. An estimation algorithm is described which minimizes the maximum possible estimation error magnitude for the given set of instrument outputs. Monte Carlo simulation results are presented for the application of the algorithms to an inertial reference unit consisting of six gyros and six accelerometers in two alternate configurations.

Potter, J. E.↗

Acoustic Measurements from Wind Tunnel Test of AMELIA - Advanced Model for Extreme Lift and Improved Aeroacoustics

A wind tunnel test has been conducted to measure the aerodynamic and acoustic performance of an active circulation-control aircraft with leading- and trailing- edge slot blowing. The 11 Advanced Model for Extreme Lift and Improved Aeroacoustics (AMELIA) model was tested in the Arnold Engineering Development Center (AEDC) National Full Scale Aerodynamics Complex (NFAC) 40- by 80-Ft wind tunnel. Forward velocities ranged from 0 to Mach 0.15 and total slot mass-flow was varied from 0 to 2.8 lbmsec. Angle-of-attack and sideslip ranges were -5 to 25 and -10 to 10, respectively.This reports summarizes acoustic measurements from the wind tunnel test and the corrections applied to the released acoustic data. The analysis focuses on measurements for the clean wing configuration (turbine propulsion simulators removed) with trailing-and leading-edge slot blowing and with trailing-edge blowing, for systematic variations in slot mass flow from nearly zero to the system maximum. The acoustic measurements from a fixed phased microphone array and seven fixed microphones were corrected for sensor directional response and atmospheric attenuation. Graphs of 13-octave spectra, narrowband spectra, and directional variations in OASPL are presented for each active lift configuration. This report is intended to document the corresponding set of corrected data that is now available for development and verification of new predictive models of the active lift source.For large slot mass flow conditions 13-octave spectral shapes were level and flat, typical of a pink noise source. Little source directivity was present in the OASPL levels for the 0 flap conditions and show only a slight downstream increase with the 60 flap configuration. For moderate to high slot mass flow conditions trailing-edge only blowing spectra were similar to leading- and trailing edge blowing cases. However for the lower mass flows variations of as much as 5 dB were observed.

CCW↗

Extreme Carrier Depletion and Superlinear Photoconductivity in Ultrathin Parallel-Aligned ZnO Nanowire Array Photodetectors Fabricated by Infiltration Synthesis

Ultrathin semiconductor nanowires enable high-performance chemical sensors and photodetectors, but their synthesis and device integration by standard complementary metal-oxide-semiconductor (CMOS)-compatible processes remain persistent challenges. This work demonstrates fully CMOS-compatible synthesis and integration of parallel-aligned polycrystalline ZnO nanowire arrays into ultraviolet photodetectors via infiltration synthesis, material hybridization technique derived from atomic layer deposition. The nanowire photodetector features unique, high device performances originating from extreme charge carrier depletion, achieving photoconductive on–off ratios of >6 decades, blindness to visible light, and ultralow dark currents as low as 1 fA, the lowest reported for nanostructure-based photoconductive photodetectors. Surprisingly, the low dark current is invariant with increasing number of nanowires and the photodetector shows unusual superlinear photoconductivity, observed for the first time in nanowires, leading to increasing detector responsivity and other parameters for higher incident light powers. Temperature-dependent carrier concentration and mobility reveal the photoelectrochemical-thermionic emission process at grain boundaries, responsible for the observed unique photodetector performances and superlinear photoconductivity. Here, the results elucidate fundamental processes responsible for photogain in polycrystalline nanostructures, providing useful guidelines for developing nanostructure-based detectors and sensors. Lastly, the developed fully CMOS-compatible nanowire synthesis and device fabrication methods also have potentials for scalable integration of nanowire sensor devices and circuitries.

36 MATERIALS SCIENCE↗

Lightning mapper and the future

A trade-off analysis was completed that reveals how the lightning mapper detection efficiency will change as a function of interference filter bandwidth, pixel field of view, and telescope aperture. It is shown that the critical parameter on which we have minimum flexibility is filter band-width. The problem is that too narrow a filter bandwidth is incompatible with wide areal coverage. The trade-off analysis demonstrates that an 80 percent lightning detection efficiency will technically be relatively straight-forward, while a 90 percent detection efficiency will apparently be difficult to achieve. Three focal plane designs are currently under consideration. One would use a single large, solid state silicon integrating array with multiple output channels and off-the-focal-plane analog, time domain, background removing fibers. A second design would use the same technology, but the sensor would consist of up to four virtually independent focal plane arrays. This design reduces the areal coverage of each detector. Thus narrower interference filters could be utilized. Superior performance would be realized at a probable increase in cost. The final design would use a three-dimensional focal plane in order to perform background removal at the focal plane. Superior performance would be achieved along with reduced weight and power requirements. Unfortunately, this focal plane technology is still under development.

Christian, H. J.↗

Synthesis of Carbon Nanotubes Array by CVD

Since the properties of multi-wall carbon nanotubes (MWCNT) are superior in many devices such as electronics and sensors, many efforts have been involved in synthesizing particular structural or dimensional MWCNT. Uniform aligned MWCNT array is one of the prototype structures for devices such as filed emission device and microelectromechanical systems in which a large length to diameter ratio may also be required. Most aligned MWCNT recently synthesized by plasma enhanced chemical vapor deposition (CVD) have cone shaped structures. This presentation will illustrate aligned MWCNT array synthesized on silicon substrates using thermal CVD that could produce MWCNT with uniform diameter. An array of nickel particles was used as catalyst for MWCNT growth. A thin Ti or Au buffer layer was coated on the substrate prior to depositing nickel particles. Because the MWCNT size depends on the catalyst particle size, the nickel particle size annealed at various temperatures was investigated. MWCNT were grown on the substrate in the temperature range of 700 C - 1000 C and the pressure range of 1 to 300 torr. Methane and hydrogen gases with methane content of 1 - 10 % were used for the MWCNT synthesis. Morphology, length and diameter of MWCNT were determined by scanning electron microscopy and Raman spectroscopy. The detailed results of synthesis and characterizations will be discussed in the presentation.

Zhu, S.↗

Solid state, CCD-buried channel, television camera study and design

An investigation of an all solid state television camera design, which uses a buried channel charge-coupled device (CCD) as the image sensor, was undertaken. A 380 x 488 element CCD array was utilized to ensure compatibility with 525 line transmission and display monitor equipment. Specific camera design approaches selected for study and analysis included (a) optional clocking modes for either fast (1/60 second) or normal (1/30 second) frame readout, (b) techniques for the elimination or suppression of CCD blemish effects, and (c) automatic light control and video gain control techniques to eliminate or minimize sensor overload due to bright objects in the scene. Preferred approaches were determined and integrated into a design which addresses the program requirements for a deliverable solid state TV camera.

Hoagland, K. A.↗

Flexible Micropost Arrays for Shear Stress Measurement

Increased fuel costs, heightened environmental protection requirements, and noise abatement continue to place drag reduction at the forefront of aerospace research priorities. Unfortunately, shortfalls still exist in the fundamental understanding of boundary-layer airflow over aerodynamic surfaces, especially regarding drag arising from skin friction. For example, there is insufficient availability of instrumentation to adequately characterize complex flows with strong pressure gradients, heat transfer, wall mass flux, three-dimensionality, separation, shock waves, and transient phenomena. One example is the acoustic liner efficacy on aircraft engine nacelle walls. Active measurement of shear stress in boundary layer airflow would enable a better understanding of how aircraft structure and flight dynamics affect skin friction. Current shear stress measurement techniques suffer from reliability, complexity, and airflow disruption, thereby compromising resultant shear stress data. The state-of-the-art for shear stress sensing uses indirect or direct measurement techniques. Indirect measurements (e.g., hot-wire, heat flux gages, oil interferometry, laser Doppler anemometry, small scale pressure drag surfaces, i.e., fences) require intricate knowledge of the studied flow, restrictive instrument arrangements, large surface areas, flow disruption, or seeding material; with smaller, higher bandwidth probes under development. Direct measurements involve strain displacement of a sensor element and require no prior knowledge of the flow. Unfortunately, conventional "floating" recessed components for direct measurements are mm to cm in size. Whispering gallery mode devices and Fiber Bragg Gratings are examples of recent additions to this type of sensor with much smaller (m) sensor components. Direct detection techniques are often single point measurements and difficult to calibrate and implement in wind tunnel experiments. In addition, the wiring, packaging, and installation of delicate micro-electromechanical devices impede the use of most direct shear sensors. Similarly, the cavity required for sensing element displacement is sensitive to particulate obstruction. This work was focused on developing a shear stress sensor for use in subsonic wind tunnel test facilities applicable to an array of test configurations. The non-displacement shear sensors described here have minimal packaging requirements resulting in minimal or no disturbance of boundary layer flow. Compared to previous concepts, device installation could be simple with reduced cost and down-time. The novelty lies in the creation of low profile (nanoscale to 100 μm) micropost arrays that stay within the viscous sub-layer of the airflow. Aerodynamic forces, which are related to the surface shear stress, cause post deflection and optical property changes. Ultimately, a reliable, accurate shear stress sensor that does not disrupt the airflow has the potential to provide high value data for flow physics researchers, aerodynamicists, and aircraft manufacturers leading to greater flight efficiency arising from more in-depth knowledge on how aircraft design impacts near surface properties.

Wohl, Christopher J.↗

Shack-Hartmann Phasing of Segmented Telescopes: Systematic Effects from Lenslet Arrays

The segments in the Keck telescopes are routinely phased using a Shack-Hartmann wavefront sensor with sub-apertures that span adjacent segments. However, one potential limitation to the absolute accuracy of this technique is that it relies on a lenslet array (or a single lens plus a prism array) to form the subimages. These optics have the potential to introduce wavefront errors and stray reflections at the subaperture level that will bias the phasing measurement. We present laboratory data to quantify this effect, using measured errors from Keck and two other lenslet arrays. In addition, as part of the design of the Thirty Meter Telescope Alignment and Phasing System we present a preliminary investigation of a lenslet-free approach that relies on Fresnel diffraction to form the subimages at the CCD. Such a technique has several advantages, including the elimination of lenslet aberrations.

segmented mirrors↗

Advanced ACTPol Cryogenic Detector Arrays and Readout

Advanced ACTPol is a polarization-sensitive upgrade for the 6 m aperture Atacama Cosmology Telescope, adding new frequencies and increasing sensitivity over the previous ACTPol receiver. In 2016, Advanced ACTPol will begin to map approximately half the sky in five frequency bands (28-230 GHz). Its maps of primary and secondary cosmic microwave background anisotropies-imaged in intensity and polarization at few arcminute-scale resolution-will enable precision cosmological constraints and also awide array of cross-correlation science that probes the expansion history of the universe and the growth of structure via gravitational collapse. To accomplish these scientific goals, the AdvancedACTPol receiver will be a significant upgrade to the ACTPol receiver, including four new multichroic arrays of cryogenic, feedhorn-coupled AlMn transition edge sensor polarimeters (fabricated on 150 mm diameter wafers); a system of continuously rotating meta-material silicon half-wave plates; and a new multiplexing readout architecture which uses superconducting quantum interference devices and time division to achieve a 64-row multiplexing factor. Here we present the status and scientific goals of the Advanced ACTPol instrument, emphasizing the design and implementation of the AdvancedACTPol cryogenic detector arrays.

secondary cosmic microwave background anisotropies↗

Solid state television camera (CCD-buried channel)

The development of an all solid state television camera, which uses a buried channel charge coupled device (CCD) as the image sensor, was undertaken. A 380 x 488 element CCD array is utilized to ensure compatibility with 525 line transmission and display monitor equipment. Specific camera design approaches selected for study and analysis included (a) optional clocking modes for either fast (1/60 second) or normal (1/30 second) frame readout, (b) techniques for the elimination or suppression of CCD blemish effects, and (c) automatic light control and video gain control (i.e., ALC and AGC) techniques to eliminate or minimize sensor overload due to bright objects in the scene. Preferred approaches were determined and integrated into a deliverable solid state TV camera which addressed the program requirements for a prototype qualifiable to space environment conditions.

Source record↗

Design Optimization for Printed Melt Wire Arrays Encapsulation

As part of the Nuclear Energy Enabling Technology (NEET) Advanced Sensor and Instrumentation (ASI) Program, Idaho National Laboratory (INL) has recently established in-house capabilities to fabricate and test new advanced-manufactured sensors for measuring peak irradiation temperature within a nuclear test reactor. Although methods of real-time temperature monitoring, such as thermocouples, may be used, the complexity of feedthroughs and attachments to collect real-time measurements greatly increases the cost of the experiment. Instead, passive monitoring techniques may be used for peak- temperature measurement that exploit the melting point of well-characterized materials (standard melt wires) to infer peak reactor temperatures. However, limited available space for instrumentation during experiments introduces an additional challenge. To accommodate this, INL has expanded its temperature- detection instrumentation capabilities to include advanced manufactured (AM) melt wires for peak irradiation temperature measurements. These melt wires can determine peak temperatures while also accommodate space limitations in irradiation experiments. In an effort to improve performance reliability of AM meltwire capabilities, a process was developed and tested to identify the significance of entrapping a high purity inert atmosphere within the packaging of printed melt wire arrays. The materials used in this study were aluminum, zinc, and tin encapsulated in high purity helium within a stainless steel (SS) 316 container. Tin, with a low melting point of approximately 230°C, Zn with a mid-melting point of approximately 420°C, and Al with a high melting point of approximately 660°C. This report describes the design, fabrication process, furnace testing and X-ray Computed Tomography (XCT) evaluation. Results show a successful outcome in creating an inert gas encapsulation and high-resolution evaluation methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal design of microseismic monitoring network: Synthetic study for the Kimberlina CO2 storage demonstration site

Microseismic monitoring can play a crucial role to ensure safe long-term geological carbon storage. For reliable long-term monitoring for CO2-injection-induced microseismic events, a surface seismic array is desirable in addition to borehole geophone sensors. Optimal design of surface seismic network is of great interest to achieve cost-effective monitoring. We develop a methodology to determine the optimal number of surface seismic stations with a geometrically satisfactory distribution for given monitoring regions. We design an optimal microseismic monitoring network based on widely-accepted guiding principles, and the relationship between the location accuracy of microseismic events and the total number of seismic stations. We determine the optimal number of seismic stations based on the trade-off curve of the event location accuracy vs. the total number of seismic stations. We apply our optimal design method to the Kimberlina carbon storage site in California. We use a synthetic Kimberlina model to show that approximately 20 surface seismic stations with a geometrically satisfactory distribution are preferred for the best trade-off between the cost and the event location accuracy.

58 GEOSCIENCES↗

Characterization of high-flux cadmium zinc telluride detectors coupled to MM-PAD readout ASICs for high-flux X-ray applications

High-flux cadmium zinc telluride (HF-CZT) is a promising material for next-generation X-ray imaging due to its high stopping power, wide bandgap, and improved resistance to radiation-induced polarization [1]. We bonded 2 mm thick HF-CZT sensors with Cornell's Mixed-Mode Pixel Array ASICs, which combine analog charge integration and in-pixel digital counting to achieve single X-ray sensitivity, large full well capacity, and frame rates up to 10 kHz [2,3]. Detector characterization showed stable electron collection above 150 V bias, while hole collection remained limited by trapping even at 700 V. Temporal studies revealed non-negligible afterglow, with an unexpected increase in afterglow at higher biases, which was reduced by infrared illumination, suggesting that injected carriers reduce trapping near contact interfaces. Polarization measurements confirmed improved stability compared to conventional CZT, though polarization effects persisted, particularly with hole collection, with up to 5% signal loss and spatial distortion at high doses.

36 MATERIALS SCIENCE↗

Atmosphere-Biosphere Interaction Study (Field Campaign Report)

The objective of this campaign was to collect hyperspectral reflectance measurements and complementary optical and infrared data of land surface (i.e., vegetation and soil) throughout the growing season (i.e., from March to September) at high temporal frequency (e.g., < 30 minutes). To collect the measurements, the EcoSpec system, a tower-based sensor system housing seven optical and infrared sensors that was developed at Argonne National Laboratory, was deployed to the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) atmospheric observatory (within the crop, south of the eddy correlation flux measurement system [ECOR] tower). The EcoSpec system consists of a spectroradiometer having 2,151 channels (350–2,500 nm), red-greenblue (RGB) camera, diffuse radiometer, thermal infrared (TIR) sensors, albedometers, Photochemical Reflectance Index (PRI) sensors, Normalized Difference Vegetation Index (NDVI) sensors, and wetness sensor. The system is designed to collect an array of land surface measurements, including hyperspectral reflectance of plants and soils, RGB photos capturing contextual information of land surface, radiant temperature of sky and land surface, incoming and reflected shortwave radiation, and incoming radiation components (direct and diffuse) as frequent as every minute from up to 12 discrete positions around the tower. This would allow us to capture inherent heterogeneity of the terrestrial ecosystem and to obtain representative spectral signatures of the plant and soil surfaces via averaging those measurements. The SGP site provides advanced atmospheric and other physical measurements that are essential for our investigation of ecosystem functions using hyperspectral reflectance measurements of land surfaces. Located in the mid-latitudes, the SGP site exhibits dynamic seasonality and a wide range of meteorological variability and flux properties that make it ideal for studying interactions between near-surface atmosphere and biosphere across a range of environmental conditions. The atmosphere, plants, and soil control terrestrial carbon and water cycles. To make more accurate climate forecasts, researchers need to understand ecosystem dynamics at the biosphere–atmosphere interface. Even though our ability to forecast ecosystem dynamics and climate at both the regional and global scales has advanced significantly, we still do not know how local phenomena affecting water and carbon fluxes—such as diurnal variations—interrelate with large-scale atmospheric/climate phenomena, and vice versa. The lack of a more thorough understanding of ecosystem dynamics and climate interactions is a key knowledge gap for the improvement of earth system models (ESMs).

54 ENVIRONMENTAL SCIENCES↗

Host-Directed, Bioelectronic Immunomodulation for Protection Against Emerging Pathogens

Acute care of patients with severe infections often relies on systemic administration of pharmaceuticals and monitoring of complex physiological symptoms to identify immune system dysfunction, which can lead to increased mortality. Furthermore, determining disease-specific treatment plans often leads to a delay in patient care. To address this, we proposed an immune modulation system that electrically detects and responds to a patient’s immune system status, creating an agnostic means of treating illness and infection. Two pieces of hardware were developed for this task: a minimally-invasive sensor and a vagus nerve stimulator. Stimulation of the vagus nerve is known to modulate the immune system. The sensor is a microfabricated, silicon-based microneedle array capable of interfacing with interstitial fluid to detect small molecules such as inflammatory proteins (cytokines) and pharmaceuticals (vancomycin). Process optimization to manufacture the needles refined the silicon etch process, creating needle patches long enough to penetrate skin and reach interstitial fluid. The needles were tested for mechanical strength and stability, and did not shatter when inserted into skin models. The needles are coated with a thin film metal, turning them into electrodes for electrochemical sensing of our target molecules. We hybridized aptamers to the surface of the electrode to act as the sensing layer and were able to detect changes in the conformation of the aptamer electrochemically in the presence of the target molecule. The stimulator was a cuff electrode that encircled the vagus nerve. Rodent studies were conducted in which rodents were exposed to an inflammatory event and vagus nerve stimulation (VNS) was applied. It was demonstrated that optimized electrical stimulation of the vagus nerve created measurably different levels of cytokines in blood samples, and certain cytokines released during the inflammatory event were either upregulated or downregulated. In sum, this project successfully developed new platforms and technologies that can, with further development, enable better temporal insight into biomarker changes in the body, letting healthcare providers know of possible immune system dysfunction before they are detected physiologically. We also demonstrated the value of VNS and its possible use in treating immune system response to inflammation and illness.

59 BASIC BIOLOGICAL SCIENCES↗

Test results on intensified charge coupled devices

CCD imaging arrays were evaluated for a photon counting astronomical sensor. Results show noise corresponding to less than 100 rms electrons and gains of approximately 1000 at 10kV accelerating voltage (greater than 5000 at 25kV). Measured charge transfer efficiencies are in excess of 0.9999, signal saturation levels are as high as 990000 electrons per pixel and peak quantum efficiencies are greater than 75%. Successful proximity focussed intensified charge coupled devices (ICCD) have been fabricated, although problems still exist with contamination and possible structural failures in the CCD's during tube manufacture.

Williams, J. T.↗

Ground truth management system to support multispectral scanner /MSS/ digital analysis

A computerized geographic information system for management of ground truth has been designed and implemented to relate MSS classification results to in situ observations. The ground truth system transforms, generalizes and rectifies ground observations to conform to the pixel size and shape of high resolution MSS aircraft data. These observations can then be aggregated for comparison to lower resolution sensor data. Construction of a digital ground truth array allows direct pixel by pixel comparison between classification results of MSS data and ground truth. By making comparisons, analysts can identify spatial distribution of error within the MSS data as well as usual figures of merit for the classifications. Use of the ground truth system permits investigators to compare a variety of environmental or anthropogenic data, such as soil color or tillage patterns, with classification results and allows direct inclusion of such data into classification operations. To illustrate the system, examples from classification of simulated Thematic Mapper data for agricultural test sites in North Dakota and Kansas are provided.

Coiner, J. C.↗