Development and experimental qualification of novel disruption prevention techniques on DIII-D

Novel disruption prevention solutions spanning a range of control regimes are being developed and tested on DIII-D to enable ITER success. First, a new real-time control algorithm has been developed and tested for regulating nearness to stability limits and maintaining safety-margins. Its first application has been for reliable prevention of vertical displacement events (VDEs) by adjusting plasma elongation (κ) and the inner-gap between the plasma and inner-wall in response to real- time open-loop VDE growth rate (γ) estimators. VDEs were robustly prevented up to average open-loop growth rates of 800 rad/s with initial tunings, with only applying shape modification when near safety limits. Second, the disruption risk during fast, emergency shutdown after large tearing and locked modes can be significantly improved by transitioning to a limited topology during shutdown. More than 50% of emergency limited shutdowns after locked modes reach a final normalized current I N < 0.3 before terminating, scaling to the 3 MA ITER requirement. This is in contrast to diverted shutdowns, the majority of which disrupt at I N > 0.8. Despite improvements, these results highlight the critical importance of early prevention. Third, a novel emergency shut down method has been developed which excites instabilities to form a warm, helical core post-thermal quench. The current quench extends to ~100ms and avoids VDEs and runaway electron generation. Novel real-time machine learning disruption prediction has been integrated with the DIII-D proximity controller, and a real- time compatible multi-mode MHD spectroscopy technique has been developed. Results presented here were enabled by a focused effort, the Disruption Free Protocol, in DIII-D’s 2019-20 campaign to complement disruption prevention experiments with a large piggy-back program. In addition to testing novel techniques, it is estimated to have helped avoid 32 potential disruptions in piggyback operations with rapid, early shutdowns after large rotating n=1 or locked modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and experimental qualification of novel disruption prevention techniques on DIII-D

Novel disruption prevention solutions spanning a range of control regimes are being developed and tested on DIII-D to enable ITER success. First, a new real-time control algorithm has been developed and tested for regulating nearness to stability limits and maintaining safety-margins. Its first application has been for reliable prevention of vertical displacement events (VDEs) by adjusting plasma elongation (κ) and the inner-gap between the plasma and inner-wall in response to real- time open-loop VDE growth rate (γ) estimators. VDEs were robustly prevented up to average open-loop growth rates of 800 rad/s with initial tunings, with only applying shape modification when near safety limits. Second, the disruption risk during fast, emergency shutdown after large tearing and locked modes can be significantly improved by transitioning to a limited topology during shutdown. More than 50% of emergency limited shutdowns after locked modes reach a final normalized current I_N < 0.3 before terminating, scaling to the 3 MA ITER requirement. Furthermore, this is in contrast to diverted shutdowns, the majority of which disrupt at I_N > 0.8. Despite improvements, these results highlight the critical importance of early prevention. Third, a novel emergency shut down method has been developed which excites instabilities to form a warm, helical core post-thermal quench. The current quench extends to ~100ms and avoids VDEs and runaway electron generation. Novel real-time machine learning disruption prediction has been integrated with the DIII-D proximity controller, and a real- time compatible multi-mode MHD spectroscopy technique has been developed. Results presented here were enabled by a focused effort, the Disruption Free Protocol, in DIII-D’s 2019-20 campaign to complement disruption prevention experiments with a large piggy-back program. In addition to testing novel techniques, it is estimated to have helped avoid 32 potential disruptions in piggyback operations with rapid, early shutdowns after large rotating n=1 or locked modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mutual Inductance Level Sensor for Use in Liquid Metals

Electromagnetic instrumentation capable of measuring the level of liquid metal has been developed at Argonne National Laboratory’s (ANL) Mechanisms Engineering Test Loop (METL). The mutual inductance level sensor (MILS) utilizes the electromagnetic coupling between two coil conductors and a surrounding liquid metal to determine the level of the liquid metal. Mineral insulated cables wrapped on a stainless steel core provide a durable sensor construction. The use of a sealed stainless steel thimble isolates the sensor from the high-temperature liquid metal, allowing for easy sensor maintenance. Modern digital electronics allow for reliable and accurate operation of the sensor. Two sensor variations have been designed and fabricated, and the first variation has seen extensive testing in a non-sodium testing stand as well as in the high-temperature sodium environment of METL. Electromagnetic finite-element analysis studies have been performed using the COMSOL Magnetic Fields Solver. Regular operation of the MILS will commence following in-situ calibration of the sensors in the METL environment.

36 MATERIALS SCIENCE↗

Design, Construction, and Testing of 0.5-m, 18-mm Period Nb 3 Sn Superconducting Undulator Magnets

We report design and fabrication of a new Nb 3 Sn-based superconducting undulator (SCU) are underway at the Advanced Photon Source (APS) of Argonne National Laboratory in collaboration with Fermilab and Lawrence Berkeley National Laboratory. To develop a robust and reliable fabrication process, the magnet development consists of several steps. First, magnetic and mechanical simulations were performed to optimize the magnet design; then, the design matured further by fabricating and testing a series of very short prototypes, ~8 cm long with a period length of 18 mm. These short prototype studies were previously reported. Second, the design was scaled to an intermediate length of ~0.5 m. These two steps led to the final design of ~1.1–m-long magnets, which are currently being fabricated. The quench behavior of each 0.5-m-long undulator magnet, as well as undulator assemblies from these magnets, was studied. The first SCU magnet assembly did not meet the design specifications due to the breakdown of the insulation. With an improved design and fabrication process based on lessons learned, the second SCU assembly achieved the design undulator field of 1.2 T. The design was further optimized, and the third set of magnets was fabricated and successfully tested.

43 PARTICLE ACCELERATORS↗

Combined quantum‐mechanical molecular mechanics calculations with NWChem and AMBER: Excited state properties of green fluorescent protein chromophore analogue in aqueous solution

Combined quantum mechanical molecular mechanics (QM/MM) calculations have become a popular methodology for efficient and accurate description of large molecular systems. In this work we introduce our development of a QM/MM framework based on two well‐known codes—NWChem and AMBER. As an initial application area we are focused on excited state properties of small molecules in an aqueous phase using an analogue of the green fluorescent protein (GFP) chromophore as a particular test case. Our approach incorporates high level coupled cluster theory for the analysis of excited states providing a reliable theoretical analysis of effects of an aqueous solvation environment on the photochemical properties of the GFP chromophore. Using a systematic approach, which involves comparison of gas phase and aqueous phase results for different protonation states and conformations, we resolve existing uncertainties regarding the theoretical interpretation of experimental data. We observe that the impact of aqueous environment on charged states generally results in blue shifts of the absorption spectra, but the magnitude of the effect is sensitive to both protonation state and conformation and can be rationalized based on charge movement into the area of higher/lower external electrostatic potentials. At neutral pH levels the experimentally observed absorption signal is most likely coming from the phenol protonated form. Our results also show that the high level electron correlated method is essential for a proper description of excited states of GFP. © 2017 Wiley Periodicals, Inc.

Pirojsirikul, Teerapong↗

Anion exchange membrane test protocol validation

This study presents the validation of protocols for measuring ion exchange capacity (IEC) and alkaline stability of anion exchange membranes (AEMs) for low-temperature water electrolysis. While protocols are often tested within individual laboratories, their results across multiple laboratories with varying equipment, environmental conditions, and personnel qualification remain unverified. The validation involved Los Alamos National Laboratory (LANL), National Renewable Energy Laboratory (NREL), and University of Oregon (UO) using the same commercially available AEM to assess reproducibility and reliability of the protocols under diverse conditions. For the IEC protocol, results across laboratories were consistent within ±10% of the NMR-determined reference value. The alkaline stability protocol could pose greater challenges due to factors such as variations in sample collection timing, preservation methods, and analytical techniques, but consistent test results for percentage IEC loss were demonstrated across institutions. These results highlight the reliability and applicability of the protocols, emphasizing the importance of validation to ensure consistency in diverse research environments.

08 HYDROGEN↗

A Prototype Dual Robot System to Perform Ultrasonic and Visual Inspection for the Bottom of Double-Shell Tanks - 18624

Up to this point, ultrasonic inspection-based condition data has only been available for double-shell tank (DST) sidewalls because direct inspection access to the primary tank bottom is limited to vent duct channels in an insulating refractory pad that the primary tank rests on. Probe access through the air slot would provide the opportunity to get information about the condition of the bottom of the primary tank, but it is a challenge to deploy a crawling robot that is capable of performing nondestructive ultrasonic and visual inspection through confined air slots. As such, a conceptual prototype of a deployable inspection robot system to enable ultrasonic and visual inspection for DST base through ventilation ducts was designed and fabricated. This prototype dual robot system consisting of the AnnulusBot and the MouseBot can be integrated with nondestructive evaluation (NDE) sensors to inspect and examine the physical properties of the underside of DSTs to enable status assessment. The AnnulusBot was designed to carry the MouseBot and to be deployed to the annulus space through a riser. To deploy the MouseBot to every ventilation channel in the annulus, the arm consisting of a boom and a forearm was used to place the MouseBot on the underside of the tank. The AnnulusBot used segmented wheels enable to traverse pipes and other potential obstacles. The cable management system utilized motorized wheels to feed the cable into the ventilation channel. This would reduce the amount of work that the MouseBot would have to do during inspection. This feeding mechanism would also be used to retrieve the MouseBot at the end of its inspection. Additionally, if the MouseBot fails, this mechanism would be used for retrieval. Once deployed, the MouseBot navigates to the center of the tank via the air ventilation channel beneath the inner shell (the primary tank) while inspecting the space. The MouseBot is then retrieved from the channel by a combination of its own drive power and the AnnulusBot retracting the attached umbilical cord. Compare with the AnnulusBot, the physical dimensional limitations of the MouseBot were a greater challenge. As the surface state of the concrete of the air channels could have variable texture, and may contain debris, it was decided not to travel along this surface. The ceiling of these channels is carbon steel and can be utilized throughout the channel. To use this travel surface, magnetic wheels were employed. A foreseeable problem with the use of magnets on this surface, is that they would preclude the use of eddy currents sensors. However, other technologies like ultrasonic technology sensors should be unaffected. Laboratory scale test was performed on a mock-up single wedge of the refractory pad to evaluate maneuverability of the MouseBot. The electronic components for the prototype would work in the ranges of 150-185 deg. F (65.6-85 deg. C). Both the AnnulusBot and MouseBot will be subject to constant radiation. All major printed circuit board (PCB) microcontroller components were designed to be situated outside of the annulus space and inside the main control panel to avoid radiation-induced failure. As future work, electronic components including the Arduinos that used Atmel commercial microcontrollers will be replaced with the high temperature rated Atmel microcontrollers so that the robots can be operated reliably at ambient temperatures up to 200 deg. F (93.3 deg. C). In addition, the robots will be service life tested to evaluate performance at elevated temperature and under gamma irradiation. (authors)

42 ENGINEERING↗

Ku-band electron linac for battery-powered hand-portable 2-MeV X-ray generator

X-ray generators, producing radiation in MeV range, are a critical tool for radiography, non-destructive testing and security applications. Field operation of such source requires them to be hand-portable, autonomous and allow parameter adjustability. RF linear accelerators can serve as a flexible, reliable, and robust radiation generator alternative to dangerous radioisotopes and bulky betatrons that are currently used for field radiography if their size, weight, cost, and imaging performance are matched to these sources. Here, in this paper, we present the design and test results of a 2 MeV Ku-band electron linac for a hand-portable X-ray generator system for field radiography being developed by RadiaBeam. The dramatic scale of miniaturization and cost-reduction is achieved thanks to the implementation of innovative technologies such as air-cooled Ku-band air-traffic control magnetrons, a split accelerating structure fabrication technique, and solid-state Marx modulators. This paper presents the design of the first prototype of the accelerator, its operation from Li-Ion batteries, as well as high-power and beam measurements.

43 PARTICLE ACCELERATORS↗

Tensile properties of ADI material in water and gaseous environments

Austempered ductile iron (ADI) is an advanced type of heat treated ductile iron, having comparable mechanical properties as forged steels. However, it was found that in contact with water the mechanical properties of austempered ductile irons decrease, especially their ductility. Despite considerable scientific attention, the cause of this phenomenon remains unclear. Some authors suggested that hydrogen or small atom chemisorption causes the weakening of the surface atomic bonds. To get additional reliable data of that phenomenon, in this paper, two different types of austempered ductile irons were tensile tested in various environments, such as: argon, helium, hydrogen gas and water. It was found that only the hydrogen gas and water gave a statistically significant decrease in mechanical properties, i.e. cause embrittlement. Furthermore, the fracture surface analysis revealed that the morphology of the embrittled zone near the specimen surface shares similarities to the fatigue micro-containing striation-like lines, which indicates that the morphology of the brittle zone may be caused by cyclic local-chemisorption, micro-embrittlement and local-fracture. - Highlights: • In contact with water and other liquids the ADI suddenly exhibits embrittlement. • The embrittlement is more pronounced in water than in the gaseous hydrogen. • The hydrogen chemisorption into ADI surface causes the formation of a brittle zone. • The ADI austempered at lower temperatures (300 °C) is more resistant to embrittlement.

36 MATERIALS SCIENCE↗

A Collection of More than 900 Gas Mixture Adsorption Experiments in Porous Materials from Literature Meta-Analysis

Information on mixture adsorption equilibrium is vital in developing adsorption-based separation processes. Because measuring mixture adsorption is more difficult than measuring single-component adsorption, far more data of the latter kind are available. Previous efforts to compile experimental mixture adsorption data for gases have given data sets with at most a few dozen examples. Here, we report the results of systematic literature meta-analysis that produced a data set of more than 900 gas mixture adsorption experiments. This collection includes data from 125 different binary mixtures including 60 different molecular species and information from 333 different adsorbents. We refer to this data set as the Binary adsorption ISOtherm ExperimeNtal 2020 (BISON-20) Database. Because the BISON-20 data set enormously expands the number and variety of experimental results for binary gas adsorption that are readily available, it will be a useful resource for future efforts in developing new materials or processes for gas separations. As initial applications of the BISON-20 data set, we show how identifying replicate measurements can be used to assess the reliability of binary adsorption data, how the accuracy of Ideal Adsorbed Solution Theory (IAST) can be systematically tested using experimental data, and how trends in selectivity for gas separations across many materials can be examined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Raytheon's next generation compact inline cryocooler architecture

Since the 1970s, Raytheon has developed, built, tested and integrated high performance cryocoolers. Our versatile designs for single and multi-stage cryocoolers provide reliable operation for temperatures from 10 to 200 Kelvin with power levels ranging from 50 W to nearly 600 W. These advanced cryocoolers incorporate clearance seals, flexure suspensions, hermetic housings and dynamic balancing to provide long service life and reliable operation in all relevant environments. Today, sensors face a multitude of cryocooler integration challenges such as exported disturbance, efficiency, scalability, maturity, and cost. As a result, cryocooler selection is application dependent, oftentimes requiring extensive trade studies to determine the most suitable architecture. To optimally meet the needs of next generation passive IR sensors, the Compact Inline Raytheon Stirling 1-Stage (CI-RS1), Compact Inline Raytheon Single Stage Pulse Tube (CI-RP1) and Compact Inline Raytheon Hybrid Stirling/Pulse Tube 2-Stage (CI-RSP2) cryocoolers are being developed to satisfy this suite of requirements. This lightweight, compact, efficient, low vibration cryocooler combines proven 1-stage (RS1 or RP1) and 2-stage (RSP2) cold-head architectures with an inventive set of warm-end mechanisms into a single cooler module, allowing the moving mechanisms for the compressor and the Stirling displacer to be consolidated onto a common axis and in a common working volume. The CI cryocooler is a significant departure from the current Stirling cryocoolers in which the compressor mechanisms are remote from the Stirling displacer mechanism. Placing all of the mechanisms in a single volume and on a single axis provides benefits in terms of package size (30% reduction), mass (30% reduction), thermodynamic efficiency (>20% improvement) and exported vibration performance (≤25 mN peak in all three orthogonal axes at frequencies from 1 to 500 Hz). The main benefit of axial symmetry is that proven balancing techniques and hardware can be utilized to null all motion along the common axis. Low vibration translates to better sensor performance resulting in simpler, more direct mechanical mounting configurations, eliminating the need for convoluted, expensive, massive, long lead damping hardware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasonic detection technology based on joint robot on composite component with complex surface

Some components have complex surface, such as the airplane wing and the shell of a pressure vessel etc. The quality of these components determines the reliability and safety of related equipment. Ultrasonic nondestructive detection is one of the main methods used for testing material defects at present. In order to improve the testing precision, the acoustic axis of the ultrasonic transducer should be consistent with the normal direction of the measured points. When we use joint robots, automatic ultrasonic scan along the component surface normal direction can be realized by motion trajectory planning and coordinate transformation etc. In order to express the defects accurately and truly, the robot position and the signal of the ultrasonic transducer should be synchronized.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a Validation Approach for an Integrated Waste Glass Melter Model

Integrated models are being developed to represent the physics occurring within the high-level and low-activity waste melters that will be used to vitrify legacy tank waste at the Hanford site. These models couple the melt pool, cold cap, and plenum region within a single computational domain. Validation of the models is essential to ensure the reliability of the numerical predictions of the operational melters. Experimental data from laboratory- and pilot-scale tests are thus being used to inform and validate various aspects of the melter model. This study presents a tiered approach to model validation consisting of a series of progressively more complex test cases designed to model the physics occurring in the full-scale system. A hierarchical methodology has been developed to segregate and simplify the physical phenomena affecting the multiphase flow and heat transfer within a waste glass melter. Finally, four hierarchical levels are defined in a validation pyramid and built up in levels of increasing complexity from unit problems to subsystem cases, to pilot-scale systems, and then to the full-scale system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detector alignment for X-ray crystallography using Millepede-II

I describe a method for accurately refining the geometrical parameters of segmented X-ray area detectors on the basis of serial crystallography data, using 'Millepede' – an algorithm created for a very similar problem in high-energy physics. The Millepede method for serial crystallography builds on the approach of Brewster et al. [Acta Cryst. (2018), D74, 877–894], in which the detector parameters are refined simultaneously with the parameters for each individual crystal. This accounts for the mutual dependency between the parameters and thereby avoids the bias and slow convergence problems that have afflicted older approaches in which the deviations between observed and calculated Bragg peak positions were taken directly as the updates for the detector panel positions. The Millepede method uses the special structure of the least-squares normal equations to reduce them to a much smaller form that can be solved very quickly, even compared with the sparse matrix methods used previously. This makes it practical to refine the detector geometry frequently and thereby maintain accurate calibration without specialized alignment campaigns. Tilts of detector panels out of the plane can be reliably refined, as can the overall distance of the detector in the beam direction. With a simulated test case, the new method produced panel shifts within 7% of the correct values with only one iteration, and produced almost exactly correct shifts after a second iteration. A simulated out-of-plane panel rotation was correctly determined to within 0.001°. Applied to experimental data from an X-ray free-electron laser, the method increased the indexable fraction of frames from 30% to 91% in a single iteration, and to 96% after two further iterations. Computing the geometry updates on the basis of 2060 crystals took only 0.819 s on desktop computing hardware, including the time taken to read the required data from disk. The scaling was found to be very close to linear for up to 100 980 sets of crystal parameters, which took only 78.2 s to process under the same conditions. The method has been applied as part of a real-time feedback system at a synchrotron radiation beamline, in which an out-of-plane detector tilt of 0.04° was detected and corrected. Possible further applications are also described here.

Millepede-II↗

SU-E-T-36: An Investigation of the Margin From CTV to PTV Using Retraction Method for Cervical Carcinoma

Purpose: This work employs the retraction method to compute and evaluate the margin from CTV to PTV based on the influence of target dosimetry of setup errors during cervical carcinoma patients treatment. Methods: Sixteen patients with cervical cancer were treated by Elekta synergy and received a total of 305 KV-CBCT images. The iso-center of the initial plans were changed according to the setup errors to simulate radiotherapy and then recalculated the dose distribution using leaf sequences and MUs for individual plans. The margin from CTV to PTV will be concluded both by the method of retracting (Fixed the PTV of the original plan, and retract PTV a certain distance defined as simulative organization CTVnx. The minimum distance value from PTV to CTVnx which get specified doses, namely guarantee at least 99% CTV volume can receive the dose of 95%, is the margin CTV to PTV we found) and the former formula method. Results: (1)The setup errors of 16 patients in X, Y and Z directions were(1.13±2.94) mm,(−1.63±7.13) mm,(−0.65±2.25) mm. (2) The distance between CTVx and PTV was 5, 9 and 3mm in X, Y and Z directions According to 2.5+0.7σ. (3) Transplantation plans displayed 99% of CTVx10- CTVx7 and received 95% of prescription dose, but CTVx6- CTVx3 departed from standard of clinic.In order to protect normal tissues, we selected 7mm as the minimum value of the margin from CTV to PTV. Conclusion: We have test an retraction method for the margin from CTV to PTV evaluation. The retraction method is more reliable than the formula method for calculating the margin from the CTV to the PTV, because it represented practice of treatment, and increasing a new method in this field.

60 APPLIED LIFE SCIENCES↗

Predicting antimicrobial resistance in Pseudomonas aeruginosa with machine learning-enabled molecular diagnostics

Limited therapy options due to antibiotic resistance underscore the need for optimization of current diagnostics. In some bacterial species, antimicrobial resistance can be unambiguously predicted based on their genome sequence. In this study, we sequenced the genomes and transcriptomes of 414 drug-resistant clinical Pseudomonas aeruginosa isolates. By training machine learning classifiers on information about the presence or absence of genes, their sequence variation, and expression profiles, we generated predictive models and identified biomarkers of resistance to four commonly administered antimicrobial drugs. Using these data types alone or in combination resulted in high (0.8–0.9) or very high (> 0.9) sensitivity and predictive values. For all drugs except for ciprofloxacin, gene expression information improved diagnostic performance. Our results pave the way for the development of a molecular resistance profiling tool that reliably predicts antimicrobial susceptibility based on genomic and transcriptomic markers. Finally, the implementation of a molecular susceptibility test system in routine microbiology diagnostics holds promise to provide earlier and more detailed information on antibiotic resistance profiles of bacterial pathogens and thus could change how physicians treat bacterial infections.

59 BASIC BIOLOGICAL SCIENCES↗

Battery Pack Life Estimation through Cell Degradation Data and Pack Thermal Modeling for BAS+ Li-Ion Batteries. Cooperative Research and Development Final Report, CRADA Number CRD-12-489

Battery Life estimation is one of the key inputs required for Hybrid applications for all GM Hybrid/EV/EREV/PHEV programs. For each Hybrid vehicle program, GM has instituted multi-parameter Design of Experiments generating test data at Cell level and also Pack level on a reduced basis. Based on experience, generating test data on a pack level is found to be very expensive, resource intensive and sometimes less reliable. The proposed collaborative project will focus on a methodology to estimate Battery life based on cell degradation data combined with pack thermal modeling. NREL has previously developed cell-level battery aging models and pack-level thermal/electrical network models, though these models are currently not integrated. When coupled together, the models are expected to describe pack-level thermal and aging response of individual cells. GM and NREL will use data collected for GM's Bas+ battery system for evaluation of the proposed methodology and assess to what degree these models can replace pack-level aging experiments in the future.

25 ENERGY STORAGE↗

Manufacturing and Reliability Science for CIGS Photovoltaics

The purpose of this program was to overcome the largest challenges to investor confidence and long product lifetime in CuIn x Ga 1-x Se 2 (CIGS)-based photovoltaic products: metastability, shading-induced hot spots, and potential-induced degradation. Key findings were made in each of these areas by studying CIGS reliability at the cell level, which very few groups are currently doing. Metastability was thought to be a function of the CIGS absorber. We have challenged the state-of-the-art by showing that the metastability seen in commercial products is likely to be caused by the buffer layer. SCAPS device modeling confirmed that the buffer layer has a significant influence on metastability in CIGS devices, and also led to a processing change - the introduction of CdS islands to Zn(O,S) buffer layers - that dramatically reduced metastability in CIGS solar cells. In the reverse-bias shading task, modeling showed us that 19% solar cells are possible with thin CIGS layers of 0.5 µm. We were able to fabricate 15.2% solar cells in this project, which is the highest reported efficiency of devices in the ultra-thin class. We also discovered that the best way to dissipate less power in reverse bias was to eliminate the intrinsic ZnO layer that is often used in CIGS devices. Lower power dissipation led to devices that allowed two times the maximum power point current density in reverse without damage. Potential-induced degradation (PID) is caused by the drift of Na+ ions from the back glass to the CIGS/Mo interface, followed by diffusion into the solar cells and to the CdS region. We found that PID can be slowed by using low-conductivity borosilicate glass that contains higher K and lower Na than soda-lime glass. Based on significant progress in each of the three reliability challenges, the CIGS cell-level reliability project was very successful. We have also proved that module-level degradation mechanisms can be tested and solved at the cell level.

14 SOLAR ENERGY↗