Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pixel detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Parallel plate capacitor TiN KID array development for the Balloon Experiment for Galactic Infrared Science

The Balloon Experiment for Galactic Infrared Science (BEGINS) will map dust spectral energy distributions (SEDs) between 25 and 250 microns near high-mass star regions, characterizing the radiation fields and dust properties of a variety of stellar environments. To accomplish these goals, BEGINS will be outfitted with roughly 1,800 titanium nitride (TiN), superconducting kinetic inductance detectors (KIDs). A parallel plate capacitor KID design is used to achieve high pixel density arrays. A cryogenic, silicon-based, metal-mesh linear variable filter will define detector band passes across the KID array. Optical coupling to the filters and telescope will be accomplished using silicon microlenses. Here we present laboratory characterization of prototype BEGINS detector arrays, describe future array development plans, and describe the testbed used to characterize the arrays.

Nicholas F. Cothard↗

SU-F-T-84: Measurement and Monte-Carlo Simulation of Electron Phase Spaces Using a Wide Angle Magnetic Electron Spectrometer

Purpose: To measure and simulate well-defined electron spectra using a linear accelerator and a permanent-magnetic wide-angle spectrometer to test the performance of a novel reconstruction algorithm for retrieval of unknown electron-sources, in view of application to diagnostics of laser-driven particle acceleration. Methods: Six electron energies (6, 9, 12, 15, 18 and 21 MeV, 40cm × 40cm field-size) delivered by a Siemens Oncor linear accelerator were recorded using a permanent-magnetic wide-angle electron spectrometer (150mT) with a one dimensional slit (0.2mm × 5cm). Two dimensional maps representing beam-energy and entrance-position along the slit were measured using different scintillating screens, read by an online CMOS detector of high resolution (0.048mm × 0.048mm pixels) and large field of view (5cm × 10cm). Measured energy-slit position maps were compared to forward FLUKA simulations of electron transport through the spectrometer, starting from IAEA phase-spaces of the accelerator. The latter ones were validated against measured depth-dose and lateral profiles in water. Agreement of forward simulation and measurement was quantified in terms of position and shape of the signal distribution on the detector. Results: Measured depth-dose distributions and lateral profiles in the water phantom showed good agreement with forward simulations of IAEA phase-spaces, thus supporting usage of this simulation source in the study. Measured energy-slit position maps and those obtained by forward Monte-Carlo simulations showed satisfactory agreement in shape and position. Conclusion: Well-defined electron beams of known energy and shape will provide an ideal scenario to study the performance of a novel reconstruction algorithm using measured and simulated signal. Future work will increase the stability and convergence of the reconstruction-algorithm for unknown electron sources, towards final application to the electrons which drive the interaction of TW-class laser pulses with nanometer thin target foils to accelerate protons and ions to multi-MeV kinetic energy. Cluster of Excellence of the German Research Foundation (DFG) “Munich-Centre for Advanced Photonics”.

07 ISOTOPE AND RADIATION SOURCES↗

A laboratory verification sensor

The use of a variant of the Hartmann test is described to sense the coalignment of the 36 primary mirror segments of the Keck 10-meter Telescope. The Shack-Hartmann alignment camera is a surface-tilt-error-sensing device, operable with high sensitivity over a wide range of tilt errors. An interferometer, on the other hand, is a surface-height-error-sensing device. In general, if the surface height error exceeds a few wavelengths of the incident illumination, an interferogram is difficult to interpret and loses utility. The Shack-Hartmann aligment camera is, therefore, likely to be attractive as a development tool for segmented mirror telescopes, particularly at early stages of development in which the surface quality of developmental segments may be too poor to justify interferometric testing. The constraints are examined which would define the first-order properties of a Shack-Hartmann alignment camera and the precision and range of measurement one could expect to achieve with it are investigated. Fundamental constraints do arise, however, from consideration of geometrical imaging, diffraction, and the density of sampling of images at the detector array. Geometrical imagining determines the linear size of the image, and depends on the primary mirror diameter and the f-number of a lenslet. Diffraction is another constraint; it depends on the lenslet aperture. Finally, the sampling density at the detector array is important since the number of pixels in the image determines how accurately the centroid of the image can be measured. When these factors are considered under realistic assumptions it is apparent that the first order design of a Shack-Hartmann alignment camera is completely determined by the first-order constraints considered, and that in the case of a 20-meter telescope with seeing-limited imaging, such a camera, used with a suitable detector array, will achieve useful precision.

Vaughan, Arthur H.↗

Update of S-NPP VIIRS Thermal Emissive Bands Radiometric Calibration Stability Monitoring Using the Moon

The Suomi-NPP VIIRS thermal emissive bands (TEB) are radiometrically calibrated on-orbit with reference to an onboard blackbody (BB) regularly operated at approximately 292.5 K. The calibration stability at other temperature ranges can be evaluated based on the observations of remote targets with stable thermal properties, such as the Moon. VIIRS has scheduled viewings of the Moon on a nearly monthly basis at a phase angle of nearly -51 degrees. In this study, the brightness temperatures (BT) of the lunar surface retrieved using the detector gain coefficients calibrated with the BB are trended to monitor the calibration stability of VIIRS TEB. Since the Lunar surface temperatures are spatially non-uniform and vary greatly with the photometric geometry, the BT trending must be based on the same regions of the Moon under the same solar illumination condition. Also, the TEB lunar images are always partially saturated because the highest lunar surface temperatures are beyond the dynamic range of all VIIRS TEB detectors. Therefore, a temporally invariant dynamic mask is designed to clip a fraction of the lunar images corresponding to the regions of the Moon that may saturate the detector at any lunar event. The BT of the remaining hottest pixels are then trended. Results show that, since the launch of VIIRS to mid-2016, the radiometric calibration of all TEB detectors has been stable within 0.4 K at the BT range of as high as 350 K.

Wang, Zhipeng↗

Silicon strip defects and their impact on electrical performance of readout electronics

Abstract In preparation for the High Luminosity LHC (HL-LHC) runs, the ATLAS inner detector will be completely replaced with an all silicon Inner Tracker (ITk). Hybrid silicon pixel modules will be used for the innermost tracking layers, and silicon micro-strip detectors will be used the outer layers of the tracker. During the production of the detector, the sensors, readout electronics, and other components will undergo a series of quality control (QC) and quality assurance tests. Defects in the fabrication of the sensors will be flagged early in the manufacturer's and ATLAS QC tests. A study of the influence of sensor defects was performed to assess the characteristics of these defects in completed modules, and whether any defect posed a risk to the operation of the front-end readout electronics. All defects were found to have no impact on the performance of the front-end readout electronics for healthy amplifier channels, and defects that short the coupling between the strip implant and the metal readout electrode were only noticeable for strip leakage currents in excess of 250 nA, beyond the end-of-life currents expected for most sensors at the HL-LHC.

Instruments & Instrumentation↗

Position-Sensitive Magnetic Calorimeters for Lynx

We describe the performance of position-sensitive metallic magnetic calorimeter X-ray detectors for potential future astrophysics missions, such as Lynx. The motivation behind this is to achieve a large focal plane area by increasing the number of pixels compared to the number of readout channels (called hydra). The detector consists of a 5×5 array of gold absorbers thermally coupled to a paramagnetic sensor. Since each absorber has a different thermal link to the sensor, it generates a different pulse shape and enables discrimination of pixel position. Recently, we have been successfully able to discriminate 25 averaged pulse shapes by means of rise-time and pulse height. The measured pulse shapes and distribution agree well with the modeling results. The estimated energy resolutions based on the pulse height and noise data we measured are 2.8–3.7 eV for MnKα X-ray photons at 50 mK.

Magnetic calorimeters↗

Development and Utility of a Four-Channel Scanner for Wildland Fire Research and Applications

The Airborne Infrared Disaster Assessment System (AIRDAS) is a four-channel scanner designed and built at NASA-Ames for the specific task of supporting research and applications on fire impacts on terrestrial and atmospheric processes and also of serving as a vital instrument in the assessment of natural and man-induced disasters. The system has been flown on numerous airframes including the Navajo, King-Air, C0130, and Lear Jet 310 and a 206. The system includes a configuration composed of a 386 PC computer workstation, a non-linear detector amplifier, a sixteen-bit digitizer, dichroic filters, and Exabyte 8500 5Gb Tape output, VHS tape output, a Rockwell GPS and a 2-axis gyro. The AIRDAS system collects digital data in four wavelength regions, which can be filtered: band 1 (0.61-0.68 microns), band 2 (1.57-1.7 microns), band 3 (3.6-5.5 microns), and band 4 (5.5-13.0 microns), an FOV of 108 degrees, an IFOV of 2.62 mrads, and a digitized swath width of 720 pixels. The inclusion of the non-linear detector amplifier allows for the accurate measurement of emitted temperature from fires and hot spots. Lab testing of the scanner has indicated temperature assessments of 800 C without detector saturation. This has advantages over previous systems which were designed for thermal measurement of earth background temperatures, and were ill-equipped for accurate determination of high intensity conditions. The scanner has been flown successfully on data collection missions since 1992 in the western US as well as Brazil. These and other research and applications responses will be presented along with an assessment of future directions with the system.a

Ambrosia, Vincent G.↗

Performance improvements of wavelength-shifting-fiber neutron detectors using high-resolution positioning algorithms

On the basis of FluoroBancroft linear-algebraic method [S.B. Andersson, Opt. Exp. 16, 18714 (2008)] three highly-resolved positioning methods were proposed for wavelength-shifting fiber (WLSF) neutron detectors. Using a Gaussian or exponential-decay light-response function (LRF), the non-linear relation of photon-number profiles vs. x-pixels was linearized and neutron positions were determined. The proposed algorithms give an average 0.03-0.08 pixel position error, much smaller than that (0.29 pixel) from a traditional maximum photon algorithm (MPA). The new algorithms result in better detector uniformity, less position misassignment (ghosting), better spatial resolution, and an equivalent or better instrument resolution in powder diffraction than the MPA. Moreover, these characters will facilitate broader applications of WLSF detectors at time-of-flight neutron powder diffraction beamlines, including single-crystal diffraction and texture analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A two dimensional silicon detectors array for quality assurance in stereotactic radiotherapy: MagicPlate-512

Purpose: Silicon diode arrays are commonly implemented in radiation therapy quality assurance applications as they have a number of advantages including: real time operation (compared to the film) and high spatial resolution, large dynamic range and small size (compared to ionizing chambers). Most diode arrays have detector pitch that is too coarse for routine use in small field applications. The goal of this work is to characterize the two-dimensional monolithic silicon diode array named “MagicPlate-512” (MP512) designed for QA in stereotactic body radiation therapy (SBRT) and stereotactic radio surgery (SRS). Methods: MP512 is a silicon monolithic detector manufactured on ap-type substrate. An array contains of 512 pixels with size 0.5 × 0.5 mm{sup 2} and pitch 2 mm with an overall dimension of 52 × 52 mm{sup 2}. The MP512 monolithic detector is wire bonded on a printed circuit board 0.5 mm thick and covered by a thin layer of raisin to preserve the silicon detector from moisture and chemical contamination and to protect the bonding wires. Characterization of the silicon monolithic diode array response was performed, and included pixels response uniformity, dose linearity, percent depth dose, output factor, and beam profiling for beam sizes relevant to SBRT and SRS and depth dose response in comparison with ionization chamber. Results: MP512 shows a good dose linearity (R{sup 2} = 0.998) and repeatability within 0.2%. The measured depth dose response for field size of 10 × 10 cm{sup 2} agreed to within 1.3%, when compared to a CC13 ionization chamber for depths in PMMA up to 30 cm. The output factor of a 6 MV Varian 2100EX medical linac beam measured by MP512 at the isocenter agrees to within 2% when compared to PTW diamond, Scanditronix point EDD-2 diode and MOSkin detectors for field sizes down to 1 × 1 cm{sup 2}. An over response of 4% was observed for square beam size smaller than 1 cm when compared to EBT3 films, while the beam profiles (FWHM) of MP512 match to within 2% the data measured by radiochromic film. Conclusions: The response of the 2D detector array, MP512, has been evaluated. The properties of the array demonstrated suitability for use as in phantom dosimeter for QA in SRS and SBRT. Although MP512 matches film measurements down to 1 × 1 cm{sup 2} well, it showed a discrepancy of 4% in the determination of output factors of beams smaller than 0.5 × 0.5 cm{sup 2} due to the field perturbation generated by the large amount of silicon surrounding the central diode. MP512 is highly capable of measuring beam size (FWHM) and has a discrepancy of less than 1.3% when compared to EBT3 film. A reduction in the detector pitch to less than 2 mm would improve the penumbra reconstruction accuracy at the cost readout electronics complexity.

07 ISOTOPE AND RADIATION SOURCES↗

Reducing the Read Noise of HAWAII-2RG Detector Systems with Improved Reference Sampling and Subtraction (IRS2)

IRS2 is a Wiener-optimal approach to using all of the reference information that Teledyne's HAWAII-2RG detector arrays provide. Using a new readout pattern, IRS2 regularly interleaves reference pixels with the normal pixels during readout. This differs from conventional clocking, in which the reference pixels are read out infrequently, and only in a few rows and columns around the outside edges of the detector array. During calibration, the data are processed in Fourier space, which is <;:lose to the noise's eigenspace. Using IRS2, we have reduced the read noise of the James Webb Space Telescope Near Infrared Spectrograph by 15% compared to conventional readout. We are attempting to achieve further gains by calibrating out recently recognized non-stationary noise that appears at the frame rate.

Rauscher, Bernard J.↗

Evaluation of a 32 x 32 InSb CCD for use in astronomy

We have been fortunate to receive several infrared CCD array detectors on loan from Santa Barbara Research Center. The devices are evaluation samples, not commercially available at this time. Dr. Alan Hoffman of SBRC has made the arrangements for this loan and provided considerable technical support to this project. One aim of this project has been to evaluate the performance potential of this array technology, using astronomical objects. A quick summary of our findings is given. In short, we have found the imaging properties to be excellent under both low and high background conditions and the sensitivity to be quite good (each pixel is competitive with current InSb single-detector systems in use for astronomy). We anticipate improved low-background performance when we run these detectors at a lower and more stable temperature. The device characteristics are described, laboratory testing is summarized, and the first astronomical imaging is presented. Various circuits developed (clocks, clock drivers, DC supplies, clamp-amplifier, and a real time display system) are given.

Forrest, W. J.↗

Evaluation of 3D pixel silicon sensors for the CMS Phase-2 Inner Tracker

The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R&D program, aiming at using 3D pixel silicon sensors in the innermost barrel layer of the detector, has been carried out by CMS in collaboration with the FBK (Trento, Italy) and CNM (Barcelona, Spain) foundries. The sensors will feature a pixel cell size of 25 × 100 µm 2 , with a centrally located electrode connected to the readout chip. The sensors are read out by the RD53A and CROCv1 chips, developed in 65 nm CMOS technology by the RD53 Collaboration, a joint effort between the ATLAS and CMS groups. This paper reports the results achieved in beam test experiments before and after irradiation, up to a fluence of approximately 2 . 6 × 1 0 16 n eq /cm 2 . Measurements of assemblies irradiated to a fluence of 1 × 10 16 n˙eq/cm 2 show a hit detection efficiency higher than 96% at normal incidence, with fewer than 2% of channels masked, across a bias voltage range greater than 50 V . Even after irradiation to a higher fluence of 1.6 × 10 16 n˙eq/cm 2 , similar performance is maintained over a bias voltage range of 30 V , remaining well within CMS requirements.

3D pixel↗

Maia Mapper: high definition XRF imaging in the lab

Here, Maia Mapper is a laboratory μXRF mapping system for efficient elemental imaging of drill core sections serving minerals research and industrial applications. It targets intermediate spatial scales, with imaging of up to ~80 M pixels over a 500×150 mm 2 sample area. It brings together (i) the Maia detector and imaging system, with its large solid-angle, event-mode operation, millisecond pixel transit times in fly-scan mode and real-time spectral deconvolution and imaging, (ii) the high brightness MetalJet D2 liquid metal micro-focus X-ray source from Excillum, and (iii) an efficient XOS polycapillary lens with a flux gain ~15,900 at 21 keV into a ~32 μm focus, and (iv) a sample scanning stage engineered for standard drill-core sections. Count-rates up to ~3 M/s are observed on drill core samples with low dead-time up to ~1.5%. Automated scans are executed in sequence with display of deconvoluted element component images accumulated in real-time in the Maia detector. Application images on drill core and polished rock slabs illustrate Maia Mapper capabilities as part of the analytical workflow of the Advanced Resource Characterisation Facility, which spans spatial dimensions from ore deposit to atomic scales.

47 OTHER INSTRUMENTATION↗

Development of X-Ray Microcalorimeter Imaging Spectrometers for the X-Ray Surveyor Mission Concept

Four astrophysics missions are currently being studied by NASA as candidate large missions to be chosen inthe 2020 astrophysics decadal survey.1 One of these missions is the X-Ray Surveyor (XRS), and possibleconfigurations of this mission are currently under study by a science and technology definition team (STDT). Oneof the key instruments under study is an X-ray microcalorimeter, and the requirements for such an instrument arecurrently under discussion. In this paper we review some different detector options that exist for this instrument,and discuss what array formats might be possible. We have developed one design option that utilizes eithertransition-edge sensor (TES) or magnetically coupled calorimeters (MCC) in pixel array-sizes approaching 100kilo-pixels. To reduce the number of sensors read out to a plausible scale, we have assumed detector geometriesin which a thermal sensor such a TES or MCC can read out a sub-array of 20-25 individual 1 pixels. In thispaper we describe the development status of these detectors, and also discuss the different options that exist forreading out the very large number of pixels.

multiplexing↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging spectrometer concepts for next-generation planetary missions

In recent years there has been an increasing interest in the imaging spectrometer concept, in which imaging is accomplished in multiple, contiguous spectral bands at typical intervals of 5 to 20 nm. There are two implementations of this concept under consideration for upcoming planetary missions. One is the scanning, or 'whisk-broom' approach, in which each picture element (pixel) of the scene is spectrally dispersed onto a linear array of detectors; the spatial information is provided by a scan mirror in combination with the vehicle motion. The second approach is the 'push-broom' imager, in which a line of pixels from the scene is spectrally dispersed onto a two-dimensional (area-array) detector. In this approach, the scan mirror is eliminated, but the optics and focal plane are more complex. This paper discusses the application of these emerging instrument concepts to the planetary program. Key issues are the trade-off between the two types of imaging spectrometer, the available data rate from a typical planetary mission, and the focal-plane cooling requirements. Specific straw-man conceptual designs for the Mars Geoscience/Climatology Orbiter (MGCO) and the Mariner Mark II Comet Rendezvous/Asteroid Flyby (CRAF) missions are discussed.

Herring, M.↗

Modulation Transfer Function of Infrared Focal Plane Arrays

Modulation transfer function (MTF) is the ability of an imaging system to faithfully image a given object. The MTF of an imaging system quantifies the ability of the system to resolve or transfer spatial frequencies. In this presentation we will discuss the detail MTF measurements of 1024x1024 pixels mid -wavelength and long- wavelength quantum well infrared photodetector, and 320x256 pixels long- wavelength InAs/GaSb superlattice infrared focal plane arrays (FPAs). Long wavelength Complementary Barrier Infrared Detector (CBIRD) based on InAs/GaSb superlattice material is hybridized to recently designed and fabricated 320x256 pixel format ROIC. The n-type CBIRD was characterized in terms of performance and thermal stability. The experimentally measured NE delta T of the 8.8 micron cutoff n-CBIRD FPA was 18.6 mK with 300 K background and f/2 cold stop at 78K FPA operating temperature. The horizontal and vertical MTFs of this pixel fully delineated CBIRD FPA at Nyquist frequency are 49% and 52%, respectively.

long-wave infrared↗