Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

A Study of Mars Dust Environment Simulation at NASA Johnson Space Center Energy Systems Test Area Resource Conversion Test Facility

The dust environment on Mars is planned to be simulated in a 20 foot thermal-vacuum chamber at the Johnson Space Center, Energy Systems Test Area Resource Conversion Test Facility in Houston, Texas. This vacuum chamber will be used to perform tests and study the interactions between the dust in Martian air and ISPP hardware. This project is to research, theorize, quantify, and document the Mars dust/wind environment needed for the 20 foot simulation chamber. This simulation work is to support the safety, endurance, and cost reduction of the hardware for the future missions. The Martian dust environment conditions is discussed. Two issues of Martian dust, (1) Dust Contamination related hazards, and (2) Dust Charging caused electrical hazards, are of our interest. The different methods of dust particles measurement are given. The design trade off and feasibility were studied. A glass bell jar system is used to evaluate various concepts for the Mars dust/wind environment simulation. It was observed that the external dust source injection is the best method to introduce the dust into the simulation system. The dust concentration of 30 Mg/M3 should be employed for preparing for the worst possible Martian atmosphere condition in the future. Two approaches thermal-panel shroud for the hardware conditioning are discussed. It is suggested the wind tunnel approach be used to study the dust charging characteristics then to be apply to the close-system cyclone approach. For the operation cost reduction purpose, a dehumidified ambient air could be used to replace the expensive CO2 mixture for some tests.

Chen, Yuan-Liang Albert↗

Pulmonary Toxicity Study of Lunar and Martian Dust Simulants Intratracheally Instilled in Mice

NASA is contemplating sending humans to Mars and the Moon for further exploration. The properties of Hawaiian and Californian volcanic ashes allow them to be used to simulate Martian and lunar dusts, respectively. NASA laboratories use these dust simulants to test performance of hardware destined for Martian or lunar environments. Workers in these test facilities are exposed to low levels of these dusts. The present study was conducted to investigate the toxicity of these dust simulants. Particles of respirable-size ranges of lunar simulant (LS), Martian simulant (MS), TiO2 (negative control) and quartz (positive control) were each intratracheally instilled (saline as vehicle) to groups of 4 mice (C57BL, male, 2-3 month old) at a single treatment of 1 (Hi dose) or 0.1 (Lo dose) mg/mouse. The lungs were harvested at the end of 7 days or 90 days for histopathological examination. Lungs of the LS-Lo groups had no evidence of inflammation, edema or fibrosis. The LS-Hi-7d group had mild to moderate acute inflammation, and neutrophilic and lymphocytic infiltration; the LS-Hi-90d group showed signs of chronic inflammation and some fibrosis. Lungs of the MS-Lo-7d group revealed mild inflammation and neutrophilic and lymphocytic infiltration; the MS-Lo-90d group showed mild fibrosis and particle-laden macrophages (PLM). Lungs of the MS-Hi-7d group demonstrated mild to moderate inflammation and large foci of PLM; the MS-Hi-90d group showed chronic mild to moderate inflammation and fibrosis. To mimic the effects of the oxidative and reactive properties of Martian soil surface, groups of mice were exposed to ozone (3 hour at 0.5 ppm) prior to MS dust instillation. Lung lesions in the MS group were more severe with the pretreatment. The results for the negative and positive controls were consistent with the known pulmonary toxicity of these compounds. The overall severity of toxic insults to the lungs were TiO2<LS<MS<Quartz. For the mice in the 90-d study, blood samples were taken for immunotoxicity study. Antinuclear antibodies (such as those against Golgi, kinetichore, and centromere) were detected in serum in a greater extent in mice treated with LS than those with quartz, suggesting that LS, like quartz, has the potential of inducing antoimmune disease.

Lam, Chiu-Wing↗

Investigation of Gear and Bearing Fatigue Damage Using Debris Particle Distributions

A diagnostic tool was developed for detecting fatigue damage to spur gears, spiral bevel gears, and rolling element bearings. This diagnostic tool was developed and evaluated experimentally by collecting oil debris data from fatigue tests performed in the NASA Glenn Spur Gear Fatigue Rig, Spiral Bevel Gear Test Facility, and the 500hp Helicopter Transmission Test Stand. During each test, data from an online, in-line, inductance type oil debris sensor was monitored and recorded for the occurrence of pitting damage. Results indicate oil debris alone cannot discriminate between bearing and gear fatigue damage.

Dempsey, Paula J.↗

FY24 Development of Improved Grout Waste Forms for Alternative Low Activity Waste Treatment

Since the WTP Low Activity Waste (LAW) Vitrification Facility was not designed to process the entire inventory of Hanford LAW, up to half of the retrieved Hanford LAW will require supplemental immobilization. Immobilizing LAW in a cementitious waste form known as Cast Stone has been investigated as a possible candidate supplemental immobilization technology. In FY21, Washington River Protection Solutions, LLC (WRPS) tasked Atkins and the Vitreous State Laboratory (VSL) of The Catholic University of America (CUA) to perform testing to evaluate methods for reducing the release of COCs, particularly nitrate, 99Tc, and 129I, from cementitious waste forms made from aqueous LAW derived from Hanford Tank Waste. FY22 work built on the FY21 results and further developed formulations while targeting higher waste loadings. The objective of this work was to perform laboratory-scale testing to further refine the most promising formulation(s) that were identified in the FY23 work. The goal of the refinement was to further reduce the release rates for 99Tc, Cr, 129I, and nitrate while maintaining workability of the fresh grout, and to increase waste loading.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The measured performance of a grazing incidence relay optics telescope for solar X-ray astronomy

The design, fabrication, and test performance of a grazing-incidence diverging magnifier (GIDM) for use in high-resolution X-ray imaging of the solar corona are described. The GIDM, designed to be mounted in front of the focus of a 30.48-cm Wolter-Schwarzschild primary, is an Ni-coated Be hyperboloid-hyperboloid structure of principal diameter 3.15 cm; the two components are mounted on a central steel plate which acts as a support and spacer. The combined instrument has overall length 1.9 m, effective focal length 5.4 m, and plate scale 26.0 micron/arcsec. In point- and line-source measurements in an 89.5-m vacuum test facility, the on-axis resolution is shown to be equal to that of the primary alone. The field of view for 1-arcsec resolution is limited to 1.25 arcmin in radius, but the effective-area limitation is less significant when CCD detectors of high quantum efficiency are used instead of film.

Moses, Dan↗

Universal Solvent Viscosity Reduction via Hydrogen Bonding Disruptors

Liquid Ion Solutions LLC (DBA RoCo Global) in partnership with Carnegie Mellon University and Carbon Capture Scientific LLC, has performed lab-scale development and evaluation of novel additives that lower the viscosity of water-lean amine solvents for post-combustion carbon dioxide capture. This project focuses on developing additives that minimize the formation of long-range electrostatic and hydrogen bonding (HB) networks, decreasing the solvent viscosity, improving diffusion, and improving the process economics. The project objectives included: 1) performing computer simulation to understand the molecular interactions of the additive molecules in water-lean CO 2 capture solvents, 2) design and synthesis of HB disruptors additives, 3) performance testing with additive molecules on model amine solvents, and 4) demonstration of the effectiveness of the optimized additives in the presence of synthetic flue gas. To meet the abovementioned objectives, the project team utilized a holistic approach that combines molecular simulation, experimental testing, and economic analysis studies. The project team developed ab initio molecular model and then perform computer simulation to develop relationship between hydrogen bonding, viscosity, and performed quantitative analysis of additive on the viscosity of the solvent. The team completed computational comparative study on a range of organic functional groups such as ethers, esters, cyclic carbonates, alkanes, and ammonium salts for their effect on viscosity gaining key insights into molecular interactions and the impact of various functional groups and molecular shapes on viscosity. Assisted with molecular simulation insights, the project team conducted additive synthesis and testing, including a proof-of-concept study, additive screening, optimization, and synthetic flue gas testing. The experimental proof-of-concept study proved that the hydrogen bonding acceptors result in significant decrease of viscosities. Detailed additive screening (exploring various functionalities and molecular structures) has been performed. Several promising additives showed excellent reduction in viscosity (30-41%) at 5% additive loading, and over 50% viscosity reduction at 10% additive loading for the model solvents. The team also performed complex screening studies on additive loadings and mixing effect among additives using the design of experiments. Based on multiple screening experiments, one additive-solvent candidate was down-selected for synthetic flue gas testing. A 100-hour continuous absorption/desorption study was conducted under simulated flue gas using a lab-scale continuous capture and separation system. No degradation (for both solvent and additive) was observed based on the GC results of the solvent samples collected from the continuous study. The team conducted preliminary engineering analyses and cost-benefit analyses to quantify the potential economic benefits of the additive approach for solvent viscosity reduction. Based on the experimental data, CO 2 capture cost savings from the capital and operating cost savings are estimated at $\$$4.7/tonne and $\$$0.3/tonne CO 2 captured, respectively. Considering the additive cost, the net benefit is estimated to be between $\$$4.32~$\$$4.86/tonne CO 2 captured.

20 FOSSIL-FUELED POWER PLANTS↗

Performing a Launch Depressurization Test on an Inflatable Space Habitat

In July, 2014 JPL's Environmental Test Laboratory successfully performed a launch depressurization test on an inflatable space habitat proposed to be installed on the International Space Station. The inflatable habitat is to be launched in the SpaceX Dragon Trunk. During the launch, the unpressurized Dragon Trunk will rapidly change from ground level atmospheric pressure to the vacuum of space. Since the inflatable habitat is tightly folded during launch with multiple layers of bladder, Kevlar fabric sections, and micro-meteoroid shielding, it was not possible to analyze or simulate how the residual air pockets would behave during the launch. If the inflatable habitat does not vent adequately and expands, it could rupture the payload bay of the launch vehicle. A launch depressurization test was chosen as the best way to qualify the inflatable habitat. When stowed, the inflatable habitat measured approximately 241 cm (95 inches) in diameter by 152 cm (60 inches) high and weighed close to 1361 kg (3,000 pounds). Two vacuum chambers connected by a large vacuum line were used to perform this test. The inflatable habitat was mounted in the smaller chamber, which was 396 cm (13 feet) in diameter and 1128 cm (37 feet) high. The larger chamber, which was 823 cm (27 feet) in diameter and 2,591 cm (85 feet) high, was rough pumped and used as a vacuum reservoir. A two stage axial type compressor and ten Stokes vacuum pumps were also used during the depressurization. Opening a butterfly valve on the vacuum line, at the smaller chamber, was manually controlled so that the smaller chamber's depressurization rate matched the launch pressure profile.

ETL↗

SOFIA: Stratospheric Observatory For Infrared Astronomy

This viewgraph presentation reviews the great astronomical observatories both space and land based that are now operational. It shows the history of the development of SOFIA, from its conception in 1986 through the contract awards in 1996 and through the planned first flight in 2007. The major components of the observatory are shown and there is a comparison of the SOFIA with the Kuiper Airborne Observatory (KAO), which is the direct predecessor to SOFIA. The development of the aft ramp of the KAO was developed as a result of the wind tunnel tests performed for SOFIA development. Further slides show the airborne observatory layout and the telescope's optical layout. Included are also vies of the 2.5 Meter effective aperture, and the major telescope's components. The presentations reviews the technical challenges encountered during the development of SOFIA. There are also slides that review the wind tunnel tests, and CFD modeling performed during the development of SOFIA. Closing views show many views of the airplane, and views of SOFIA.

Kunz, Nans↗

Spray Bar Zero-Gravity Vent System for On-Orbit Liquid Hydrogen Storage

During zero-gravity orbital cryogenic propulsion operations, a thermodynamic vent system (TVS) concept is expected to maintain tank pressure control without propellant resettling. In this case, a longitudinal spray bar mixer system, coupled with a Joule-Thompson (J-T) valve and heat exchanger, was evaluated in a series of TVS tests using the 18 cu m multipurpose hydrogen test bed. Tests performed at fill levels of 90, 50, and 25 percent, coupled with heat tank leaks of about 20 and 50 W, successfully demonstrated tank pressure control within a 7-kPa band. Based on limited testing, the presence of helium constrained the energy exchange between the gaseous and liquid hydrogen (LH2) during the mixing cycles. A transient analytical model, formulated to characterize TVS performance, was used to correlate the test data. During self-pressurization cycles following tank lockup, the model predicted faster pressure rise rates than were measured; however, once the system entered the cyclic self-pressurization/mixing/venting operational mode, the modeled and measured data were quite similar. During a special test at the 25-percent fill level, the J-T valve was allowed to remain open and successfully reduced the bulk LH2 saturation pressure from 133 to 70 kPa in 188 min.

Hastings, L. J.↗

Low-Emission Hydrogen Combustors for Gas Turbines Using Lean Direct Injection

One of the key technology challenges for the use of hydrogen in gas turbine engines is the performance of the combustion system, in particular the fuel injectors. To investigate the combustion performance of gaseous hydrogen fuel injectors flame tube combustor experiments were performed. Tests were conducted to measure the nitrogen oxide (NO(x)) emissions and combustion performance at inlet conditions of 588 to 811 K, 0.4 to 1.4 MPa, and equivalence ratios up to 0.48. All the injectors were based on Lean Direct Injection (LDI) technology with multiple injection points and quick mixing. One challenge to hydrogen-based premixing combustion systems is flashback since hydrogen has a reaction rate over 7 times that of Jet-A. To reduce the risk, design mixing times were kept short and velocities high to minimize flashback. Five fuel injector designs were tested in 6.35- and 8.9-cm-diameter flame tubes with non-vitiated heated air and gaseous hydrogen. Data is presented on measurements of NO(x) emissions and combustion efficiency for the hydrogen injectors at 2.540, 7.937, and 13.652 cm from the injector face. Results show that for some configurations, NO(x) emissions are comparable to that of state of the art Jet-A LDI combustor concepts.

Marek, C. John↗

HSCT Ref-H Transonic Flap Data Base: Wind-Tunnel Test and Comparison with Theory

In cooperation with personnel from the Boeing ANP Laboratory and NASA Langley, a performance test was conducted using the Reference-H 1.675% model ("NASA Modular Model") without nacelles at the NASA Langley 16-Ft Transonic Tunnel. The main objective of the test was to determine the drag reduction achievable with leading-edge and trailing-edge flaps deflected along the outboard wing span at transonic Mach numbers (M = 0.9 to 1.2) for purpose of preliminary design and for comparison with computational predictions. The obtained drag data with flap deflections for Mach numbers of 1.07 to 1.20 are unique for the Reference H wing. Four leading-edge and two trailing-edge flap deflection angles were tested at a mean-wing chord-Reynolds number of about 5.7 million. An outboard-wing leading-edge flap deflection of 81 provides a 4.5 percent drag reduction at M = 1.2 A = 0.2), and much larger values at lower Mach numbers with larger flap deflections. The present results for the baseline (no flaps deflected) compare reasonably well with previous Boeing and NASA Ref-H tunnel tests, including high-Reynolds number NTF results. Viscous CFD simulations using the OVERFLOW thin-layer N.S. method properly predict the observed trend in drag reduction at M = 1.2 as function of leading-edge flap deflection. Modified linear theory properly predicts the flap effects on drag at subsonic conditions (Aero2S code), and properly predicts the absolute drag for the 40 and 80 leading-edge deflection at M = 1.2 (A389 code).

Vijgen, Paul M.↗

Real-Time Drilling Optimization System for Improved Overall Rate of Penetration and Reduced Cost Per Foot in Geothermal Drilling

The key to success in geothermal drilling is economic feasibility, and a major cost in the development of geothermal resources is the actual drilling of the wells. In this project, a real-time drilling optimization system for geothermal drilling was developed. The system couples three individual components while drilling. The first component is a drill stem vibration analysis model, the second is Mechanical Specific Energy (MSE) analyses, and the third is a detailed PDC Rate of Penetration (ROP) drill bit model for optimum RPM and WOB combinations. The benefit of the coupled system is that the range of WOB and RPM could be selected to avoid drill stem vibrations. Secondly, MSE is used as an efficiency measure and the detailed PDC drill bit model ensures the drill bit does not endure temperatures that exceed the temperature at which the PDC cutters experience accelerated wear. The new detailed PDC bit model is based on rock/bit interaction that physically tracks the PDC cutter wear flats as the bit drills ahead giving the capability to calculate the temperature being generated underneath the worn cutters to better advise on operational parameters to avoid accelerated cutter wear and failure and to ensure that operational parameters are applied so that overall ROP is maximized. By combining the drill stem vibrations and the detailed PDC bit cutter wear and “safe” non-accelerated cutter wear temperature and optimum ranges of operating parameters, it results in higher ROP and lower cost drilling. Single cutter PDC testing performed in different lithologies at Sandia was utilized to verify the PDC cutter forces and depth of cut for new and worn cutters. Based on single cutter PDC temperature modeling, verification using single cutter data from the testing done by National Oilwell Varco (NOV) was performed. Sandia’s Hard-Rock Drilling Facility (HRDF) was utilized to test different drill bit configurations with different cutter designs and wear status with different induced modes of vibration to obtain the critical bit RPM/WOB ranges resulting in ineffective drilling and low ROP. The collected test data were further used to verify and calibrate the full hole PDC ROP model that was developed based on single cutter interaction data. A full coupled drill stem vibration model was formulated and verified with geothermal field data from the Chocolate Mountain Aerial Gunnery Range (CMAGR). A graphical user interface (GUI) was developed using Tkinter library in the computer programming language Python, which integrates all the developed models in one system. The developed system consists mainly of the PDC ROP model, PDC bit wear model, PDC cutter temperature model, Mechanical Specific Energy (MSE) model, and drillstring vibration model integrated into one system. The developed system can be used for both, post well analysis and real-time optimization using different criteria such as ROP maximization or MSE minimization. The software uses Differential Evolution Algorithm (DEA) to find optimum values for operational parameters based on last foot drilled while avoiding the drillstring vibration and cutter temperature critical operating parameters.

15 GEOTHERMAL ENERGY↗

Characterization of the Heat Extraction Capability of a Compliant, Sliding, Thermal Interface for Use in a High Temperature, Vacuum Microgravity Furnace

Much of the material science gained in microgravity research requires processing a sample in a high performance furnace. One such furnace currently being designed is the Quench Module Insert (QMI). The Principle Investigators, for whom the furnace is proposed, require high temperature gradients in their cylindrical samples to achieve the science objectives. One of the components critical to achieving high sample axial temperature gradients in the Quench Module Insert is a high performance cold zone to extract the heat from the sample. This cold zone employs a compliant, sliding thermal interface based on a Vel-Therm felt. This felt provides a conductive path between the Sample Cartridge Assembly (SCA) exterior surface and the interior surface of the water cooled chill block while allowing movement of the sample relative to the chill block. The Vel-Therm felt is composed of long polymer-based fibers affixed to a thin flexible substrate layer. The fibers are oriented perpendicular to this substrate giving the felt the appearance of a velvet fabric. The Vel-Therm felt heat extraction capability was quantified in earlier tests performed in an inert gas environment. The current activity, described in this paper, is intended to characterize the extraction capability of Vel-Therm felt in a vacuum environment similar to the QMI environment. This testing is necessary to quantify the thermal performance of the Vel-Therm felt and the sensitivity of that performance to key variables. The data derived from these tests will be incorporated into the current thermal models to improve the quality of the models and reduce uncertainty of the analytical results. In addition, the data will be used to help select the appropriate Vel-Therm felt and set proper operating limits as well as assess the performance range of the furnace. The objective of this test is to measure the heat extraction rate of the Vel-Therm felt as specified by the effective heat transfer coefficient. Therefore, the test setup was designed to force the bulk of the heat transfer through the area where the Vel-Therm felt was applied. A heat source, consisting of a ceramic heating element encased in a Copper (Cu) housing is mounted on four isolated support rods. A 6-layer molybdenum radiation shield is used to insulate against heat loss from the heater and prevent heat exchange between the hot and cold sides of the test apparatus. The Vel-Therm felt is affixed to the surface of the cold sink, a water-cooled Cu chill block. An adjustable plate supports and isolates the cold sink from above and is used to control the amount of the deflection of the Vel- Therm when in contact with the Cu heating element housing. The primary means of establishing the power being conducted through the felt is to measure the energy being transferred to the water passing through the chill block. Analysis was performed to support the assumption that the source and sink surfaces were approximately isothermal under the specific test conditions. As a check on the amount of power passing through the felt, the power supplied to the heater was also measured. Thermocouples were strategically located throughout the test apparatus for measurement purposes. A bell jar was lowered over the assembly to impose vacuum conditions. Currently, variables tested have been fiber compression and fiber type and surface temperatures (both the hot and cold side temperatures are hypothesized to be important to the performance of the Vel-Therm.) Selected runs were repeated to ensure consistency and repeatability. Results obtained thus far reveal that Vel-Therm performance is significantly degraded by fibers being exposed to high compression. It also shows that performance is somewhat negatively impacted by previous compression, thereby, raising the question of repeatability. In addition, early results show a significant dependence on temperature. A computer aided mathematical analysis of the test setup is ongoing. The results will be correlated to actual results. The correlation will examine such details as parasitic loses, conduction down the power leads and many other concerns.

Bellomy-Ezell, Jenny↗

PKI solar thermal plant evaluation at Capitol Concrete Products, Topeka, Kansas

A system feasibility test to determine the technical and operational feasibility of using a solar collector to provide industrial process heat is discussed. The test is of a solar collector system in an industrial test bed plant at Capitol Concrete Products in Topeka, Kansas, with an experiment control at Sandia National Laboratories, Albuquerque. Plant evaluation will occur during a year-long period of industrial utilization. It will include performance testing, operability testing, and system failure analysis. Performance data will be recorded by a data acquisition system. User, community, and environmental inputs will be recorded in logs, journals, and files. Plant installation, start-up, and evaluation, are anticipated for late November, 1981.

Hauger, J. S.↗

The development of an augmentor wing jet STOL research aircraft (modified C-8A). Volume 2: Analysis of contractor's flight test

The initial flight test phase of the modified C-8A airplane was conducted. The primary objective of the testing was to establish the basic airworthiness of the research vehicle. This included verification of the structural design and evaluation of the aircraft's systems. Only a minimum amount of performance testing was scheduled; this has been used to provide a preliminary indication of the airplane's performance and flight characteristics for future flight planning. The testing included flutter and loads investigations up to the maximum design speed. The operational characteristics of all systems were assessed including hydraulics, environmental control system, air ducts, the vectoring conical nozzles, and the stability augmentation system (SAS). Approaches to stall were made at three primary flap settings: up, 30 deg and 65 deg, but full stalls were not scheduled. Minimum control speeds and maneuver margins were checked. All takeoffs and landings were conventional, and STOL performance was not scheduled during this phase of the evaluation.

Skavdahl, H.↗

Fast and Accurate Core Analysis by the Full-Immersion Pressure-Pulse Decay: Part 2—Practice and Demonstration

Summary This study continues the work of presenting a novel approach for making petrophysical assessments of tight core samples. This method, the full-immersion pressure-pulse decay (Hannon 2019), involves applying a rapid increase in pressure in a chamber surrounding the entire outer surface area of a cylindrical sample, shutting the system in, and monitoring the pressure decay in the chamber as it reaches a new equilibrium. A precursor article covered the numerical simulator designed to model flow through the sample, demonstrating its performance and accuracy in addition to providing a first-order comparison between the speed and shape of the pressure-decay responses of the full-immersion method with those of other similar transient methods. This study covers the parameter-estimation procedure and experimental verification through a proof-of-concept laboratory investigation. The investigations provided here demonstrate that under appropriate, achievable experimental conditions, the pressure data can be analyzed in such a way that returns an estimate of the porosity and apparent permeabilities both parallel and perpendicular to bedding from a single test performed on a single cylindrical sample. After determining these experimental conditions (the uniqueness window), this report outlines a data-inversion strategy to estimate the petrophysical properties (porosity, horizontal permeability, and vertical permeability) from each test. This strategy is put to the test through comparisons with measurements performed by a commercial core laboratory. A common set of samples recovered from an outcrop of a tight-gas sandstone formation were investigated using the full-immersion method, and their results are compared with those from conventional steady-state measurement procedures performed by the commercial laboratory. Comparisons between petrophysical characterizations of these samples, which had permeabilities between 25 nd and 2.3 μd, demonstrated close agreement in most cases. However, whereas steady-state measurements performed at the professional laboratory required 4 to 5 hours of testing time per measurement of a single permeability, similar assessments using the full-immersion technique, requiring approximately 5 to 10 minutes to complete, returned estimates of the horizontal and vertical permeability simultaneously. Additional analyses are provided to determine principal reasons of discrepancies in instances where agreement was not as strong. Based on lessons learned from these experiences, the report closes with suggestions on areas of improvement in the experimental approach. Once complete, these developments should propel this technology to fill a critical need to determine petrophysical properties (porosity and permeability) of tight rocks in a time-efficient manner and in a way that does not compromise their accuracy.

Energy & Fuels↗

Lightning testing at the subsystem level

Testing at the subsystem or black box level for lightning hardness is required if system hardness is to be assured at the system level. The often applied philosophy of lighting testing only at the system level leads to extensive end of the line design changes which result in excessive costs and time delays. In order to perform testing at the subsystem level two important factors must be defined to make the testing simulation meaningful. The first factor is the definition of the test stimulus appropriate to the subsystem level. Application of system level stimulations to the subsystem level usually leads to significant overdesign of the subsystem which is not necessary and may impair normal subsystem performance. The second factor is the availability of test equipment needed to provide the subsystem level lightning stimulation. Equipment for testing at this level should be portable or at least movable to enable efficient testing in a design laboratory environment. Large fixed test installations for system level tests are not readily available for use by the design engineers at the subsystem level and usually require special operating skills. The two factors, stimulation level and test equipment availability, must be evaluated together in order to produce a practical, workable test standard. The neglect or subordination of either factor will guarantee failure in generating the standard. It is not unusual to hear that test standards or specifications are waived because a specified stimulation level cannot be accomplished by in-house or independent test facilities. Determination of subsystem lightning simulation level requires a knowledge and evaluation of field coupling modes, peak and median levels of voltages and currents, bandwidths, and repetition rates. Practical limitations on test systems may require tradeoffs in lightning stimulation parameters in order to build practical test equipment. Peak power levels that can be generated at specified bandwidths with standard electrical components must be considered in the design and costing of the test system. Stimulation tests equipment and test methods are closely related and must be considered a test system for lightning simulation. A non-perfect specification that can be reliably and repeatedly applied at the subsystem test level is more desirable than a perfect specification that cannot be applied at all.

Luteran, Frank↗

Extended Modeling of DOE Sealed Canisters with Updated Chemistry Models

Road-ready and final disposition packaging configurations for the advanced test reactor (ATR) fuel currently specifies storage within helium backfilled DOE sealed standard canisters. The aluminum cladding of the ATR fuel contains an oxyhydroxide layer of boehmite/bayerite that generates hydrogen when subjected to irradiation. Understanding the effect of this hydrogen buildup over time to important for long term storage considerations. Previous modeling efforts have built a coupled CFD-chemical model to simulate the temperature gas phase concentrations within the DOE sealed standard canisters. These models have coupled the temperature conditions to both the gas phase radiolysis chemistry and the surface chemistry associated with the oxyhydroxide layer. The previous iteration of the model utilized constant G-values for the hydrogen generation a 50-year period. This new iteration of the model utilizes new experimental data to update the hydrogen generation rate, as well as increase the simulated time to a 200-year period. Given the half-life assumed for the primary Cs-137 isotope responsible for gamma radiation in the ATR spent fuel, the 200-year period decreases the decay heat and dose rate of the spent fuel by a factor of 100, which combined with the updated chemistry substantially decreases new hydrogen generation. Continued experimental work has identified trends for aluminum surrogate samples with oxyhydroxide layers for tests done at higher dose rates. At low initial doses a fast generation rate of hydrogen occurs which starts to roll over to a lower generation as the total dose applied increase. A small-scale chemical model was built to replicate as mini-canister surrogate system at SRNL as well as for the smaller capsule tests performed at INL. A variety of chemical models to capture this effect were tested, and a back reaction of H radical absorbing onto the surface, or inhibition of the reaction by significant H 2 cover gas were both able to fit both the mini-canister and the small capsule test data. Both kinetic fits were used to generate data from the new 200-year simulation. As additional experiments continue, the kinetic fits may be adjusted to adapt to new data. However, updated data shows that hydrogen atmosphere has little effect on actual generation data, so the model was reverted to use a star-stepped G-value for low-dose and high-dose regions. For the undried fuel case, the three models differ significantly with an end concentration of 1% for back reaction, 4.2% for inhibition, and 13.1% for constant G-value for the nominal scenario. For the dried fuel case, the nominal cases showed end concentrations of 0.23% for back reaction, 1.9% for inhibition, and 4.2% for const G-value for the nominal scenario. For the constant G-value case that is less conservative than the other two, the pressure for undried fuel increases to 1.94 atm over 200 years for the nominal case and 2.11 atm for the high decay heat case. The total hydrogen concentration after 200 years is 4.92% for the low decay heat case and 27.4% for the high decay heat case for undried fuel and is 1.4% and 9.6% for low and high decay heat fuel for the dried fuel case. If small amount of residual air is present, the potential for nitric acid formation of 595, 1568, and 2816 ppm for the lower, nominal, and upper fuel decay heat can occur. At long-term timeframes no significant shift in major species present occurs, so no appreciable amount of oxygen is present in the system. The continued rate of hydrogen generation in the canister occurs at an increase of 0.04% by mole over the final 10 years. Increasing the model range out to 1000 years continues to drop the hydrogen generation rate through decreasing dose rate.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗