Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Correlation tracking for a Planetary Pointing and Tracking System

The Planetary Pointing and Tracking System (PPTS) is being developed to provide precision pointing for science platforms on future autonomous planetary spacecraft. The PPTS design approach using a CCD optical sensor for closed-loop control with respect to the target body, a gyro for inertial stabilization, and brushless dc torque motors for smooth and continuous platform articulation is essential for high resolution planetary imaging and automated science execution. An integral part of PPTS is the correlation tracker which has the potential to revolutionize autonomous guidance.

Assefi, T.↗

Using the radiative temperature difference at 3.7 and 11 microns to track dust outbreaks

The radiative temperature difference between 3.7 and 11 microns (Delta T) is investigated as a possible method for tracking dust outbreaks. Theoretical calculations indicate that the technique would be most sensitive to dust loading during the day when the Delta Ts are enhanced by reflection of 3.7-micron solar radiation. The feasibility of tracking dust outbreaks is demonstrated by comparing satellite observations with surface estimates of visibility. Theoretical calculations also demonstrate the potential of inferring the dust layer optical depth from these spectral measurements.

Ackerman, Steven A.↗

Simulating A Massive, Mobile Structure

Simulator replicates, kinematically and dynamically, mating of large, massive mobile structure with similarly large and massive fixed structure. Developed for testing berthing-and-latching mechanism. Fixed section holds active berthing-and-latching mechanism and its motor control system with optical encoder to maintain synchronization among four latches in mechanism. Tripodal load-cell network gathers data on load history of berthing operation, and infrared tracking system including light-emitting diodes produces data for position history.

Fantasia, Peter M.↗

Aerosol optical depth retrievals over the Konza Prairie

The aerosol optical depth over the Konza Prairie, near Manhattan, Kansas, was recorded at various locations by five separate teams. These measurements were made in support of the First ISLSCP Field Experiment (FIFE) and used to correct imagery from a variety of satellite and aircraft sensors for the effects of atmospheric scattering and absorption. The results from one instrument are reported here for 26 days in 1987 and for 7 in 1989. Daily averages span a range of 0.05 to 0.28 in the midvisible wavelengths. In addition, diurnal variations are noted in which the afternoon optical depths are greater than those of the morning by as much as 0.07. A comparison between instruments and processing techniques used to determine these aerosol optical depths is provided. The first comparisons are made using summer 1987 data. Differences of as much as 0.05 (midvisible) are observed. Although these data allow reasonable surface reflectance retrievals, they do not agree to within the performance limits typically associated with these types of instruments. With an accuracy goal of 0.02 a preseason calibration/comparison experiment was conducted at a mountain site prior to the final field campaign in 1989. Good calibration data were obtained, and good agreement (0.01, midvisible) was observed in the retrieved optical depth acquired over the Konza. By comparing data from the surface instruments at different locations, spatial inhomogeneities are determined. Then, data from the airborne tracking sunphotometer allow one to determine variations as a function of altitude. Finally, a technique is proposed for using the in situ data to establish an instrument calibration.

Bruegge, Carol J.↗

Moderate Resolution Imaging Spectrometer-Tilt (MODIS-T) baseline concept

There will be several state of the art spectrometers in operation on the NASA Polar Orbiting Platform (NPOP-1) as part of the Earth Observing System (EOS). The Moderate Resolution Imaging Spectrometer (MODIS) will consist of two imaging spectroradiometric instruments, one nadir viewing (MODIS-N) and the other tiltable (MODIS-T) for ocean observation and land bidirectional reflectance studies. The Moderate Resolution Imaging Spectrometer-Tilt (MODIS-T) instrument is presently being constructed for flight on the EOS. It is an imaging spectrometer utilizing a grating type, reflecting Schmidt optical design that must provide a 1.1 kilometer spatial resolution at nadir from a spacecraft altitude of 705 kilometers with a 1500 kilometer cross-track swath and a +/- 50 degree forward and aft tilt capability. The instrument is required to cover the wavelength range from 400 to 880 nanometers in approximately 15 nanometer steps with less than 2.3 percent instrument induced polarization. The absolute radiometric accuracy must be at least 5 percent over the full dynamic range of the instrument.

Magner, Thomas J.↗

TLRS-3 system upgrades

This presentation describes the upgrades to the Transportable Laser Ranging Systems serial number three (TLRS-3), and the impact that these upgrades will have on the TLRS-3 performance in the field. The four major areas of system upgrades are the HP-380 computer, the Optical Attenuation Mechanism (OAM), the upgraded spatial, spectral and temporal filtering for improved daylight ranging capability, and the software upgrade to enable the system to track the Etalon satellites. The TLRS-3 was returned to the Goddard Geophysical and Astronomical Observatory (GGAO) in December 1991 for system upgrades in preparation of the TOPEX/POSEIDON campaign scheduled to begin in the summer of 1992. Many system upgrades were incorporated into the system while interleaving planned facility maintenance making TLRS-3 a more versatile and more dependable laser ranging system. The TLRS-3 was initially baselined with the MOBLAS-7 via simultaneous satellite ranging on the LAGEOS, Ajisai, Starlette, and ERS-I satellites. During the upgrades and following completion of the system upgrades intercomparisons with the MOBLAS-7 were made to verify the integrity and accuracy of the system changes. Several other groups of personnel participated in the TLRS-3 upgrade and they are: the Survey Section, the Precision Measurement Equipment Laboratory, the Architectural and Engineering Services Department, the Precision Timing Section, and the station personnel at TLRS-3 and MOBLAS-7.

Eichinger, Richard↗

Validation of Ocean Color Remote Sensing Data using a Moored Databuoy

NASA's Sea-Viewing Wide Field-of-View Sensor (SeaWiFS) aims to measure global ocean color from space to within 5% to provide insights into fundamental ocean processes. SeaWiFS must be backed by comprehensive calibration and validation programs if the mission is to achieve this. In situ measurements of normalized water-leaving radiance (L(sub wn)) made simultaneously with satellite measurements can complement on-orbit methods of tracking changes in the calibration of the satellite radiometer and allow end-to-end vicarious validation of the remotely-sensed data. A moored optical databuoy was developed at Plymouth Marine Laboratory, UK to measure L(sub wn) in the western English Channel. Tests indicate that the buoy is capable of measuring spectral incident irradiance with less than 10% error and water-leaving radiance with less than 20% error; these errors are reduced by averaging and show no bias. There were 24 match-ups with good quality SeaWiFS data at the buoy site during the ten months of deployment within the period May 1997 and September 1998. The differences between the buoy and SeaWiFS measurements of L(sub wn) were found to be variable and often large. The root-mean-square (RMS) differences varied from 102% at 412 nm to 50% at 555 nm. The RMS differences in measurements of L(sub wn) could be reduced to less than 18% by a combination of increasing the calibration coefficients of SeaWiFS by between 0.2 and 4.3% in the visible bands and by tuning the extrapolation of aerosol radiances from the near infrared to the visible wavelengths. These results imply that the monitoring of the absolute calibration of the SeaWiFS bands is imperfect and errors remain in the extrapolation of aerosol radiances for atmospheric correction.

Lavender, Samantha↗

Mobile Aerial Tracking and Imaging System (MATRIS) for Aeronautical Research

A mobile, rapidly deployable ground-based system to track and image targets of aeronautical interest has been developed. Targets include reentering reusable launch vehicles (RLVs) as well as atmospheric and transatmospheric vehicles. The optics were designed to image targets in the visible and infrared wavelengths. To minimize acquisition cost and development time, the system uses commercially available hardware and software where possible. The conception and initial funding of this system originated with a study of ground-based imaging of global aerothermal characteristics of RLV configurations. During that study NASA teamed with the Missile Defense Agency/Innovative Science and Technology Experimentation Facility (MDA/ISTEF) to test techniques and analysis on two Space Shuttle flights.

Banks, Daniel W.↗

NASA Tech Briefs, October 2011

Topics covered include: Laser Truss Sensor for Segmented Telescope Phasing; Qualifications of Bonding Process of Temperature Sensors to Deep-Space Missions; Optical Sensors for Monitoring Gamma and Neutron Radiation; Compliant Tactile Sensors; Cytometer on a Chip; Measuring Input Thresholds on an Existing Board; Scanning and Defocusing Properties of Microstrip Reflectarray Antennas; Cable Tester Box; Programmable Oscillator; Fault-Tolerant, Radiation-Hard DSP; Sub-Shot Noise Power Source for Microelectronics; Asynchronous Message Service Reference Implementation; Zero-Copy Objects System; Delay and Disruption Tolerant Networking MACHETE Model; Contact Graph Routing; Parallel Eclipse Project Checkout; Technique for Configuring an Actively Cooled Thermal Shield in a Flight System; Use of Additives to Improve Performance of Methyl Butyrate-Based Lithium-Ion Electrolytes; Li-Ion Cells Employing Electrolytes with Methyl Propionate and Ethyl Butyrate Co-Solvents; Improved Devices for Collecting Sweat for Chemical Analysis; Tissue Photolithography; Method for Impeding Degradation of Porous Silicon Structures; External Cooling Coupled to Reduced Extremity Pressure Device; A Zero-Gravity Cup for Drinking Beverages in Microgravity; Co-Flow Hollow Cathode Technology; Programmable Aperture with MEMS Microshutter Arrays; Polished Panel Optical Receiver for Simultaneous RF/Optical Telemetry with Large DSN Antennas; Adaptive System Modeling for Spacecraft Simulation; Lidar-Based Navigation Algorithm for Safe Lunar Landing; Tracking Object Existence From an Autonomous Patrol Vehicle; Rad-Hard, Miniaturized, Scalable, High-Voltage Switching Module for Power Applications; and Architecture for a 1-GHz Digital RADAR.

Source record↗

The Track Imaging Cerenkov Experiment

We describe a dedicated cosmic-ray telescope that explores a new method for detecting Cerenkov radiation from high-energy primary cosmic rays and the large particle air shower they induce upon entering the atmosphere. Using a camera comprising 16 multi-anode photomultiplier tubes for a total of 256 pixels, the Track Imaging Cerenkov Experiment (TrICE) resolves substructures in particle air showers with 0.086deg resolution. Cerenkov radiation is imaged using a novel two-part optical system in which a Fresnel lens provides a wide-field optical trigger and a mirror system collects delayed light with four times the magnification. TrICE records well-resolved cosmic-ray air showers at rates ranging between 0.01-0.1 Hz.

Wissel, S. A.↗

Airborne tracking sunphotometer apparatus and system

An airborne tracking Sun photometer apparatus has a rotatable dome. An azimuth drive motor is connected to rotate the dome. The dome has an equatorial slot. A cylindrical housing is pivotally mounted inside the dome at the equatorial slot. A photometer is mounted in the housing to move in the equatorial slot as the housing pivots. The photometer has an end facing from the slot with an optical flat transparent window. An elevation drive motor is connected to pivot the cylindrical housing. The rotatable dome is mounted in the bulkhead of an aircraft to extend from the interior of the aircraft. A Sun sensor causes the photometer to track the Sun automatically. Alternatively, the photometer may be oriented manually or by computer.

Matsumoto, Yutaka↗

Ultrafast low-temperature metal–insulator interface phonon dynamics and heat transport in a Pt/Gd 3 Fe 5 O 12 heterostructure

Interfacial thermal and acoustic phenomena have an important role in quantum science and technology, including in spintronic and spincaloritronic materials and devices. Simultaneous measurements of the low-temperature thermal and acoustic properties of a metal/insulator heterostructure reveal distinct dynamics in the characteristic phonon frequency ranges of acoustic and thermal transport. The measurements probed a heterostructure consisting of a thin film of Pt on the ferrimagnetic insulator gadolinium iron garnet (Gd 3 Fe 5 O 12 , GdIG) grown epitaxially on a gadolinium gallium garnet substrate. Ultrafast structural dynamics within the Pt layer were tracked using time-resolved ultrafast x-ray diffraction and analyzed to probe interfacial acoustic and thermal properties. The rapid heating of the Pt layer by a 400 nm wavelength femtosecond-duration optical pulse produced transient structural changes that provided the stimulus for these measurements. Rapid heating produced a broadband acoustic pulse that was partially reflected by the Pt/GdIG interface. Temporal frequencies up to 740 GHz, corresponding to angular frequencies of several THz, were detected in a wavelet analysis of the acoustic oscillations of the strain in the Pt layer. The structural results were analyzed to determine (i) the acoustic damping coefficient and phonon mean free path in Pt at frequencies of hundreds of GHz and (ii) the Grüneisen anharmonicity parameter. The thermal conductance of the Pt/GdIG interface was tracked using the slower, tens-of-picosecond-scale, dynamics of the initial cooling of the heated Pt layer. Analysis using a model based on the Boltzmann transport equation shows that the phonon transmission is lower at the phonon frequencies relevant to thermal transport than for subterahertz regime acoustics.

Acoustic phenomena↗

Crossed beam roof target for motion tracking

A system for detecting motion between a first body and a second body includes first and second detector-emitter pairs, disposed on the first body, and configured to transmit and receive first and second optical beams, respectively. At least a first optical rotator is disposed on the second body and configured to receive and reflect at least one of the first and second optical beams. First and second detectors of the detector-emitter pairs are configured to detect the first and second optical beams, respectively. Each of the first and second detectors is configured to detect motion between the first and second bodies in multiple degrees of freedom (DOFs). The first optical rotator includes a V-notch oriented to form an apex of an isosceles triangle with respect to a base of the isosceles triangle formed by the first and second detector-emitter pairs. The V-notch is configured to receive the first optical beam and reflect the first optical beam to both the first and second detectors. The V-notch is also configured to receive the second optical beam and reflect the second optical beam to both the first and second detectors.

Olczak, Eugene↗

Optical attenuation mechanism upgrades, MOBLAS, and TLRS systems

This poster presentation describes the Optical Attenuation Mechanism (OAM) Upgrades to the MOBLAS and TLRS Crustal Dynamics Satellite Laser Ranging (CDSLR) systems. The upgrades were for the purposes of preparing these systems to laser range to the TOPEX/POSEIDON spacecraft when it will be launched in the summer of 1992. The OAM permits the laser receiver to operate over the expected large signal dynamic range from TOPEX/POSEIDON and it reduces the number of pre- and post-calibrations for each satellite during multi-satellite tracking operations. It further simplifies the calibration bias corrections that had been made due to the pass-to-pass variation of the photomultiplier supply voltage and the transmit filter glass thickness. The upgrade incorporated improvements to the optical alignment capability of each CDSLR system through the addition of a CCD camera into the MOBLAS receive telescope and an alignment telescope onto the TLRS optical table. The OAM is stepper motor and microprocessor based; and the system can be controlled either manually by a control switch panel or computer controlled via an EIA RS-232C serial interface. The OAM has a neutral density (ND) range of 0.0 to 4.0 and the positioning is absolute referenced in steps of 0.1 ND. Both the fixed transmit filter and the daylight filter are solenoid actuated with digital inputs and outputs to and from the OAM microprocessor. During automated operation, the operator has the option to overide the remote control and control the OAM system via a local control switch panel.

Eichinger, Richard↗

Effect of parallactic refraction correction on station height determination

The effect of omitting the parallactic refraction correction for satellite optical observations in the determination of station coordinates is analyzed for a large satellite data distribution. A significant error effect is seen in station heights. A geodetic satellite data distribution of 23 close earth satellites, containing 30,000 optical observations obtained by 13 principal Baker-Nunn camera sites, is employed. This distribution was used in a preliminary Goddard Earth Model (GEM 1) for the determination of the gravity field of the earth and geocentric tracking station locations. The parallactic refraction correction is modeled as an error on the above satellite data and a least squares adjustment for station locations is obtained for each of the 13 Baker-Nunn sites. Results show an average station height shift of +8 meters with a dispersion of plus or minus 0.7 meters for individual sites. Station latitude and longitude shifts amounted to less than a meter. Similar results are obtained from a theoretical method employing a probability distribution for the satellite optical observations.

Lerch, F. J.↗

Earth/Moon System Star Tracking Sensor for Improved Deep Space Laser Communications

The goal of this research is to improve deep space communication links by exploring a new concept in stellar navigation that uses images of the Earth/Moon system to obtain precise pointing information so that the laser signal from the satellite can be directed at the ground station with unprecedented accuracy. Currently, the concept for satellite pointing relies on a dual axis star tracker that compares images of the celestial sphere to a star catalog to obtain a 3-axis orientation solution. Most star trackers are designed with a wide field of view (required to obtain enough bright starts to achieve a navigational fix) and only provide reliable pitch and yaw estimates thus necessitating the use of a second star tracker looking at an axis perpendicular to the first one to obtain an accurate estimate of the roll of the spacecraft. In the new concept the optical design will be modified to ensure that both the Earth and the Moon will be within a narrow field of view centered on Earth relative to the field of view of most star tracking systems. Because of the proximity of the bodies, it is possible to obtain highly accurate estimates of the pitch, yaw and roll of the spacecraft relative to the Earth/Moon system. The new tracker will allow for accurate 3-axis control of the spacecraft from a single tracker thus allowing the second star tracker, which would normally be pointed in a direction perpendicular to the one pointed at earth, to obtain the spacecraft roll estimate. This wide field star tracker facilitates functions like the initial satellite pointing during the acquisition phase of establishing the laser communication link or solving the lost in space problem should the system need to be reset. This new design will be tested in simulation and compared for 3-axis pointing accuracy against a standard commercial star tracker.

Star tracker↗

Multiwell Fiber Optic Sensing Reveals Effects of CO2 Flow on Triggered Seismicity

Induced seismicity is one of the main risks for gigaton-scale geological storage of carbon dioxide (⁠CO 2 ⁠). Thus, passive seismic monitoring is often recommended as a necessary component of the monitoring systems for CO 2 storage projects, with a particular forcus on risk mitigation. We present the first field study, CO2CRC Otway Project Stage 3 (Victoria, Australia), where distributed acoustic sensing (DAS) enabled high-precision tracking of the induced seismicity triggered by a small CO 2 injection and also informed the reservoir models. In 610 days of passive seismic monitoring of the Stage 3 injection, we detected 17 microseismic events (maximum moment magnitude Mw 0.1) using five deep boreholes equipped with enhanced-sensitivity optical fiber. The DAS array has sensitivity sufficient for detection and location of induced events with M w ~ ₋2 in a monitoring borehole located up to 1500 m away. Thanks to the dense spatial sampling by the DAS, we were able to estimate the focal mechanisms for events with M w > ₋1.5; although the monitoring boreholes provided very limited angular coverage. The main cluster of the events has the same location and source mechanism as the one triggered by the previous CO 2 injection at the Otway Project site, Stage 2C. Surprizingly, the Stage 2C and Stage 3 events closely followed the actual movement of the CO 2 saturation plume front (not the pressure front), as observed using controlled-source reflection seismic images. The nature of the plume-fault interaction remains unclear, but some alteration of the fault gouge by CO 2 might be responsible for the faults’ reactivation by the pressure perturbation. Importantly, the seismogenic fault could not be identified in the seismic images and was only revealed by DAS observations, which also demonstrated the signature of fluid–rock interaction, that may control the CO 2 flow.

58 GEOSCIENCES↗

Optimization of the Orbiting Wide-Angle Light Collectors (OWL) Mission for Charged-Particle and Neutrino Astronomy

OWL [1] uses the Earth's atmosphere as a vast calorimeter to fully enable the emerging field of charged-particle astronomy with high-statistics measurements of ultra-high-energy cosmic rays (UHECR) and a search for sources of UHE neutrinos and photons. Confirmation of the Greisen-Zatsepin-Kuzmin (GZK) suppression above approx. 4 x 10(exp 19) eV suggests that most UHECR originate in astrophysical objects. Higher energy particles must come from sources within about 100 Mpc and are deflected by approx. 1 degree by predicted intergalactic/galactic magnetic fields. The Pierre Auger Array, Telescope Array and the future JEM-EUSO ISS mission will open charged-particle astronomy, but much greater exposure will be required to fully identify and measure the spectra of individual sources. OWL uses two large telescopes with 3 m optical apertures and 45 degree FOV in near-equatorial orbits. Simulations of a five-year OWL mission indicate approx. 10(exp 6) sq km/ sr/ yr of exposure with full aperture at approx. 6 x 10(exp 19) eV. Observations at different altitudes and spacecraft separations optimize sensitivity to UHECRs and neutrinos. OWL's stereo event reconstruction is nearly independent of track inclination and very tolerant of atmospheric conditions. An optional monocular mode gives increased reliability and can increase the instantaneous aperture. OWL can fully reconstruct horizontal and upward-moving showers and so has high sensitivity to UHE neutrinos. New capabilities in inflatable structures optics and silicon photomultipliers can greatly increase photon sensitivity, reducing the energy threshold for n detection or increasing viewed area using a higher orbit. Design trades between the original and optimized OWL missions and the enhanced science capabilities are described.

Optimization↗