Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Alignment apparatus using a laser having a gravitationally sensitive cavity reflector

A description is given of a device for determining a true gravitational vertical. The apparatus is composed of a vertically disposed laser with a gravitationally sensitive lower regeneration reflector. The reflector enables an output beam to be developed only when the optical axis of the laser is disposed normal to the gravitationally sensitive reflective surface. In an alternative embodiment, the devices is combined with a servo system to provide a gravitationally stabilized horizontal platform.

Billman, K. W.↗

Birefringence-balanced polarimetric optical fiber sensor for high-temperature measurements

A birefringence-balanced polarimetric multimode fiber temperature sensor is proposed and demonstrated. Two single-crystal sapphire rods are incorporated into the sensor head. They are connected end to end in such a way that the slow axis of the first rod is aligned with the fast axis of the second rod, referred to as the referencing rod. Since the lengths of the two rods are chosen to be almost the same, the original birefringence of the first rod is balanced by that of the second rod. A light-emitting diode serves as the light source. This sensor has been experimentally demonstrated for high-temperature measurements as high as 1500 C. A sensitivity of 5 C has been obtained.

Wang, Anbo↗

Microelectronics Instrument Products Shock and Vibration Electro-Optics: Acceptance Data Package - Section B

The motor/encoder (henceforth referred to as the UUT) test sequence began with a baseline functional evaluation, which demonstrated that the motor satisfied the operating torque, cogging torque, winding resistance, and mechanical requirements of SOW. In addition, the encoder electrical requirements were verified, as well as the alignment of the encoder outputs relative to the motor shaft position. There were no discrepancies observed in this portion of the test. The UUT was then exposed to a number of environments, including thermal vacuum, thermal cycling, random and sine vibration, and mechanical shock. During the thermal environments, the performance of the UUT under load was verified at specified points in the cycles, as described in ATP 20049. In addition, the UUT was bench tested between the two thermal environments. No anomalies were observed during the thermal tests. The vibration and shock tests were performed by East-West Technology Corporation, West Babylon, New York. The UUT was delivered to the lab in a sealed vibration fixture in order to maintain the cleanliness levels required by the SOW. In addition, a three ounce load was attached to the motor shaft. The attachment method of this load caused damage to the shaft and bearing during random vibration of S/N 0003 on April 28, 1995, and is described further in NCR 00168.

Source record↗

Back-illuminated imager and method for making electrical and optical connections to same

Methods for bringing or exposing metal pads or traces to the backside of a backside-illuminated imager allow the pads or traces to reside on the illumination side for electrical connection. These methods provide a solution to a key packaging problem for backside thinned imagers. The methods also provide alignment marks for integrating color filters and microlenses to the imager pixels residing on the frontside of the wafer, enabling high performance multispectral and high sensitivity imagers, including those with extremely small pixel pitch. In addition, the methods incorporate a passivation layer for protection of devices against external contamination, and allow interface trap density reduction via thermal annealing. Backside-illuminated imagers with illumination side electrical connections are also disclosed.

Pain, Bedabrata↗

Ion cyclotron absorption at the second harmonic of the oxygen gyrofrequency

A hot ray tracing code (HOTRAY) is used to establish the ultimate demise of the wave energy generated inside the plasmasphere during storm conditions. The code uses the WKB approximation of geometric optics to calculate the paths of electromagnetic and electrostatic waves in a hot, multiion plasma. Ray tracing calculations with HOTRAY are detailed and path integrated absorption is discussed. Unducted waves which are preferentially generated in the field aligned direction are rapidly refracted to large wave normal angles. The waves are observed to reflect at frequencies between oxygen and helium gyrofrequencies once their frequency falls below the bi-ion frequency and the waves bounce back accross the equator. Either Landau resonance with plasmaspheric electrons or second harmonic cyclotron resonance with thermal oxygen ultimately absorb the wave energy. It is suggested that both processes may provide a significant heating mechanism for either population during a storm.

Horne, R. B.↗

Mathematical Investigation of Gamma Ray and Neutron Absorption Grid Patterns for Homeland Defense Related Fourier Imaging Systems

Terrorist suitcase nuclear devices typically using converted Soviet tactical nuclear warheads contain several kilograms of plutonium. This quantity of plutonium emits a significant number of gamma rays and neutrons as it undergoes radioactive decay. These gamma rays and neutrons normally penetrate ordinary matter to a significant distance. Unfortunately this penetrating quality of the radiation makes imaging with classical optics impractical. However, this radiation signature emitted by the nuclear source may be sufficient to be imaged from low-flying aerial platforms carrying Fourier imaging systems. The Fourier imaging system uses a pair of co-aligned absorption grids to measure a selected range of spatial frequencies from an object. These grids typically measure the spatial frequency in only one direction at a time. A grid pair that looks in all directions simultaneously would be an improvement over existing technology. A number of grid pairs governed by various parameters were investigated to solve this problem. By examining numerous configurations, it became apparent that an appropriate spiral pattern could be made to work. A set of equations was found to describe a grid pattern that produces straight fringes. Straight fringes represent a Fourier transform of a point source at infinity. An inverse Fourier transform of this fringe pattern would provide an accurate image (location and intensity) of a point source.

Boccio, Dona↗

Grazing Incidence Wavefront Sensing and Verification of X-Ray Optics Performance

Evaluation of interferometrically measured mirror metrology data and characterization of a telescope wavefront can be powerful tools in understanding of image characteristics of an x-ray optical system. In the development of soft x-ray telescope for the International X-Ray Observatory (IXO), we have developed new approaches to support the telescope development process. Interferometrically measuring the optical components over all relevant spatial frequencies can be used to evaluate and predict the performance of an x-ray telescope. Typically, the mirrors are measured using a mount that minimizes the mount and gravity induced errors. In the assembly and mounting process the shape of the mirror segments can dramatically change. We have developed wavefront sensing techniques suitable for the x-ray optical components to aid us in the characterization and evaluation of these changes. Hartmann sensing of a telescope and its components is a simple method that can be used to evaluate low order mirror surface errors and alignment errors. Phase retrieval techniques can also be used to assess and estimate the low order axial errors of the primary and secondary mirror segments. In this paper we describe the mathematical foundation of our Hartmann and phase retrieval sensing techniques. We show how these techniques can be used in the evaluation and performance prediction process of x-ray telescopes.

Saha, Timo T.↗

Fabrication of an Absorber-Coupled MKID Detector

Absorber-coupled microwave kinetic inductance detector (MKID) arrays were developed for submillimeter and far-infrared astronomy. These sensors comprise arrays of lambda/2 stepped microwave impedance resonators patterned on a 1.5-mm-thick silicon membrane, which is optimized for optical coupling. The detector elements are supported on a 380-mm-thick micro-machined silicon wafer. The resonators consist of parallel plate aluminum transmission lines coupled to low-impedance Nb microstrip traces of variable length, which set the resonant frequency of each resonator. This allows for multiplexed microwave readout and, consequently, good spatial discrimination between pixels in the array. The transmission lines simultaneously act to absorb optical power and employ an appropriate surface impedance and effective filling fraction. The fabrication techniques demonstrate high-fabrication yield of MKID arrays on large, single-crystal membranes and sub-micron front-to-back alignment of the micro strip circuit. An MKID is a detector that operates upon the principle that a superconducting material s kinetic inductance and surface resistance will change in response to being exposed to radiation with a power density sufficient to break its Cooper pairs. When integrated as part of a resonant circuit, the change in surface impedance will result in a shift in its resonance frequency and a decrease of its quality factor. In this approach, incident power creates quasiparticles inside a superconducting resonator, which is configured to match the impedance of free space in order to absorb the radiation being detected. For this reason MKIDs are attractive for use in large-format focal plane arrays, because they are easily multiplexed in the frequency domain and their fabrication is straightforward. The fabrication process can be summarized in seven steps: (1) Alignment marks are lithographically patterned and etched all the way through a silicon on insulator (SOI) wafer, which consists of a thin silicon membrane bonded to a thick silicon handle wafer. (2) The metal microwave circuitry on the front of the membrane is patterned and etched. (3) The wafer is then temporarily bonded with wafer wax to a Pyrex wafer, with the SOI side abutting the Pyrex. (4) The silicon handle component of the SOI wafer is subsequently etched away so as to expose the membrane backside. (5) The wafer is flipped over, and metal microwave circuitry is patterned and etched on the membrane backside. Furthermore, cuts in the membrane are made so as to define the individual detector array chips. (6) Silicon frames are micromachined and glued to the silicon membrane. (7) The membranes, which are now attached to the frames, are released from the Pyrex wafer via dissolution of the wafer wax in acetone.

Brown, Ari↗

Technical Oversight of the Nancy Grace Roman Space Telescope Optical Telescope Assembly (OTA) Element Procurement: Opportunities, Challenges, & Lessons Learned (2024 Update)

Nancy Grace Roman Space Telescope Optical Telescope Assembly (OTA) is an out-of-house procurement from L3Harris currently being integrated and tested in Rochester, NY. Building upon L3Harris’s decades of success producing world-class optical systems for government and commercial customers offers NASA a proven partner and a tremendous opportunity for high performance and value. Inheriting significant portions of the telescope (including the primary and secondary mirror, composite metering structures and alignment drives) from a previous program presents the opportunity to save cost and schedule but constrains the design space for the unique challenges of the Roman mission. This seminar will cover a brief description of the OTA and its history, some of the challenges posed by incorporating an established product line and inherited hardware into a Class A mission, and some approaches and lessons learned that may be helpful for those structuring new missions or providing technical oversight of out-of-house procurements.

Joshua Abel↗

Tunable plasmon-enhanced second-order optical nonlinearity in transition metal dichalcogenide nanotriangles

The development of nanomaterials with a large nonlinear susceptibility is essential for nonlinear nanophotonics. Here we show that transition metal dichalcogenide (TMD) nanotriangles have a large effective second-order susceptibility [χ (2) ] at midinfrared to near-infrared frequencies owing to their broken centrosymmetry. χ (2) is calculated within the density-matrix formalism that accounts for dissipation and screening. χ (2) peaks in the vicinity of both two-photon resonances (specified by the geometry) and plasmon resonances (tunable via the carrier density). Aligning the resonances yields the values of χ (2) as high as 10 –6 m/V. These findings underscore the potential of TMD nanotriangles for nonlinear nanophotonics, particularly second-harmonic generation.

0-dimensional systems↗

Next Generation X-Ray Optics: High-Resolution, Light-Weight, and Low-Cost

X-ray telescopes are essential to the future of x-ray astronomy. This paper describes a comprehensive program to advance the technology for x-ray telescopes well beyond the state of the art represented by the three currently operating missions: Chandra, XMM-Newton , and Suzaku . This program will address the three key issues in making an x-ray telescope: (I) angular resolution, (2) effective area per unit mass, and (3) cost per unit effective area. The objectives of this technology program are (1) in the near term, to enable Explorer-class x-ray missions and an IXO type mission, and (2) in the long term, to enable a flagship x-ray mission with sub-arcsecond angular resolution and multi-square-meter effective area, at an affordable cost. We pursue two approaches concurrently, emphasizing the first approach in the near term (2-5 years) and the second in the long term (4-10 years). The first approach is precision slumping of borosilicate glass sheets. By design and choice at the outset, this technique makes lightweight and low-cost mirrors. The development program will continue to improve angular resolution, to enable the production of 5-arcsecond x-ray telescopes, to support Explorer-class missions and one or more missions to supersede the original IXO mission. The second approach is precision polishing and light-weighting of single-crystal silicon mirrors. This approach benefits from two recent commercial developments: (1) the inexpensive and abundant availability of large blocks of mono crystalline silicon, and (2) revolutionary advances in deterministic, precision polishing of mirrors. By design and choice at the outset, this technique is capable of producing lightweight mirrors with sub-arcsecond angular resolution. The development program will increase the efficiency and reduce the cost of the polishing and the lightweighting processes, to enable the production of lightweight sub-arcsecond x-ray telescopes. Concurrent with the fabrication of lightweight mirror segments is the continued development and perfection of alignment and integration techniques, for incorporating individual mirror segments into a precision mirror assembly. Recently, we have been developing a technique called edge-bonding, which has achieved an accuracy to enable 10- arcsecond x-ray telescopes. Currently, we are investigating and improving the long-term alignment stability of so-bonded mirrors. Next, we shall refine this process to enable 5-arsecond x-ray telescopes. This technology development program includes all elements to demonstrate progress toward TRL-6: metrology; x-ray performance tests; coupled structural, thermal, and optical performance analysis, and environmental testing.

Zhang, William W.↗

Next Generation X-Ray Optics: High-Resolution, Light-Weight, and Low-Cost

X-ray telescopes are essential to the future of x-ray astronomy. In this talk I will describe a comprehensive program to advance the technology for x-ray telescopes well beyond the state of the art represented by the three currently operating missions: Chandra, XMM-Newton, and Suzaku. This program will address the three key issues in making an x-ray telescope: (1) angular resolution, (2) effective area per unit mass, and (3) cost per unit effective area. The objectives of this technology program are (1) in the near term, to enable Explorer-class x-ray missions and an IXO-type mission, and (2) in the long term, to enable a flagship x-ray mission with sub-arcsecond angular resolution and multi-square-meter effective area, at an affordable cost. We pursue two approaches concurrently, emphasizing the first approach in the near term (2-5 years) and the second in the long term (4-10 years). The first approach is precision slumping of borosilicate glass sheets. By design and choice at the outset, this technique makes lightweight and low-cost mirrors. The development program will continue to improve angular resolution, to enable the production of 5-arcsecond x-ray telescopes, to support Explorer-class missions and one or more missions to supersede the original IXO mission. The second approach is precision polishing and light-weighting of single-crystal silicon mirrors. This approach benefits from two recent commercial developments: (1) the inexpensive and abundant availability of large blocks of monocrystalline silicon, and (2) revolutionary advances in deterministic, precision polishing of mirrors. By design and choice at the outset, this technique is capable of producing lightweight mirrors with sub-arcsecond angular resolution. The development program will increase the efficiency and reduce the cost of the polishing and the light-weighting processes, to enable the production of lightweight sub-arcsecond x-ray telescopes. Concurrent with the fabrication of lightweight mirror segments is the continued development and perfection of alignment and integration techniques, for incorporating individual mirror segments into a precision mirror assembly. Recently, we have been developing a technique called edge-bonding, which has achieved an accuracy to enable 10-arcsecond x-ray telescopes. Currently, we are investigating and improving the long-term alignment stability of so-bonded mirrors. Next, we shall refine this process to enable 5-arsecond x-ray telescopes. This technology development program includes all elements to demonstrate progress toward TRL-6: metrology; x-ray performance tests; coupled structural, thermal, and optical performance analysis, and environmental testing.

Zhang, William W.↗

The dynamical state of eROSITA clusters and its impact on the brightest cluster galaxy luminosity

The first Spectrum-Roentgen-Gamma (SRG) eROSITA public release contains 12 247 clusters and groups from its first 6 months of operation. We used the offset between the brightest cluster galaxy (BCG) and the X-ray peak ( D BCG − X ) to classify the cluster dynamical state of 3946 galaxy clusters and groups. We aim to investigate the evolution of the merger and relaxed cluster distributions with redshift and mass, and the distributions’ impact on the BCG. We used the X-ray peak from the eROSITA survey and the BCG position from the LS DR10 optical data, which includes the DECam eROSITA Survey optical data, to measure the D BCG − X offset. We modelled the distribution of D BCG − X , in units of R 500 , as the sum of two Rayleigh distributions representing the cluster’s relaxed and disturbed populations, and explored their evolution with redshift and mass. To explore the impact of the cluster’s dynamical state on the BCG luminosity, we separated the main sample according to the dynamical state. We defined clusters as relaxed if D BCG − X < 0.25R500, disturbed if D BCG − X > 0.5R500, and ‘diverse’ if 0.25R500 < D BCG − X < 0.5R500. We find no evolution of the merging fraction with redshift or mass. The width of the relaxed distribution increases with redshift, while the width of the two Rayleigh distributions decreases with mass. The analysis reveals that BCGs in relaxed clusters are brighter than BCGs in both the disturbed and diverse cluster populations. The most significant differences are found for high-mass clusters at higher redshifts. The results suggest that BCGs in low-mass clusters are less centrally bound than those in high-mass systems, irrespective of the dynamical state. Over time, BCGs in relaxed clusters progressively align with the potential centre. This alignment correlates with their luminosity growth relative to BCGs in dynamically disturbed clusters, underscoring the critical role of the cluster’s dynamical state in regulating BCG evolution.

galaxy clusters↗

HFTS-2 Completions Design and State-of-the-Art Diagnostics Results

Various completion schemes were tested as part of the Hydraulic Fracture Test Site-2 (HFTS-2) project. The wells were instrumented with permanent fiber optic (FO) cable, and unique near-wellbore and far-field region surveys were acquired to evaluate spatial and temporal hydraulic fracture characteristics. The state-of-the-art diagnostics included substantial monitoring of both the well stimulation and longer-term production performance. The objective was to evaluate and improve stimulation distribution effectiveness (SDE) for different completion designs based on the diagnostics results. A hydraulic fracturing (HF) profile (i.e., proppant/fluid allocation among clusters) was obtained using near-wellbore Distributed Acoustic Sensing (DAS) data acquired during stimulation. Statistical analysis provided a quantitative assessment of SDE for the different completion designs. A novel workflow was developed to assess time-lapse fracture property changes at the cluster and stage levels based on Distributed Strain Sensing (DSS) data acquired during the production phase. These time-lapse fracture property changes were compared with the HF profile. Based on the statistical analysis, Rate Per Cluster (RPC) during proppant slurry placement appears to be a primary completion design variable, rather than the typical Rate Per Perf (RPP). If RPC was not maintained at a certain level, the likelihood of uneven distribution increased dramatically. The stage configurations that created low RPC while maintaining high RPP did not show improved SDE. The strain change results based on DSS data during the production phase indicated near-wellbore fracture property changes (e.g., aperture changes during well shut-in and flow periods) and aligned well with near-wellbore DAS signals acquired during stimulation. More importantly, fracture property changes based on DSS data acquired during two tests over a 7-month period show high consistency and good alignment with the near-wellbore HF profile. This workflow quantitatively evaluates SDE for different completion designs using diagnostic results and could help optimize completion strategy for future development projects. Here, the analysis and interpretation of results demonstrate the technical feasibility of using permanent fiber optic cable for stimulation and production monitoring and indic

58 GEOSCIENCES↗

Time-resolved nanosecond optical pyrometry of the vapor to plasma transitions in exploding bridgewires

Electrically exploded wires find uses throughout high-energy physics. For example, they are commonly used as high-temperature sources, X-ray generators, and in precision timing detonators. However, the detailed and complete physics that occurs is complex and still poorly understood. A full mechanistic description of these complex phenomena is beyond the scope of a single paper. Instead, we focus on the formation of metal vapor and its transition to plasma. This single transition is commonly assumed to comprise “bridge-burst”. We use a suite of diagnostics including a novel, fiber-based, high-speed, optical pyrometer to better characterize this transition. The primary finding from this project is that peak light output from an exploding wire does not temporally match the peak temperature. Additionally, it is found that peak light does not align with peak bridge-burst voltage and that the peak temperature is not voltage-dependent. These findings are non-intuitive and will allow for the correction of false assumptions previously made about this topic.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Shutters and slats for the integral sunshade of an optical reception antenna

Optical reception antennas used at a small Sun-Earth-probe angle (small solar elongation E) require sunshading to prevent intolerable scattering of light from the surface of the primary mirror. An integral sunshade consisting of hexagonal tubes aligned with the segmentation of a large mirror was proposed for use down to E = 12 degrees. For smaller angles, asterisk-shaped vanes inserted into the length of the hexagonal tubes would allow operation down to about 6 degrees with a fixed obscuration of 3.6 percent. Two alternative methods are investigated to extend the usefulness of the integral sunshade to smaller angles by adding either variable-area shutters to block the tube corners that admit off-axis sunlight or by inserting slats (partial vanes) down the full length of some tubes. Slats are effective for most operations down to 6 degrees, and obscure only 1.2 percent. For E between 10.75 and 12 degrees, shutters cause even less obscuration.

Kerr, E. L.↗

Broad band X-ray telescope (BBXRT) displacement monitor system (DMS) testing and calibration

NASA's shuttle-borne Broad Band X-Ray Telescope (BBXRT) consists of two glancing incidence imaging mirror assemblies mounted on an optical bench which is bolted to the primary structure of the instrument. The X-ray detectors are located in the focal plane of the mirror assemblies approximately 3.5 meters away. It is desirable to monitor the relative alignment of these components throughout ground testing, and to determine the magnitude of launch or thermally induced perturbations to the alignment during flight. The Displacement Monitor System (DMS) was designed to accomplish this task. This paper describes the design of the DMS, the development and optimization of the DMS calibration facility, and the characterization of the system. The characterization of the DMS includes environmental qualification, displacement vs output calibration over the operating temperature range, a detailed error analysis, and the generation of a calibration polynomial which utilizes DMS detector output and thermocouple data to optimize system performance. The DMS accuracy exceeded the requirements of a 15 arc second limit of error, and passed the stringent environmental tests. As such, the DMS is one of the first flight qualified displacement monitor systems with this accuracy to be flown in space.

Hagopian, John G.↗

Angular displacement measuring device

A system for measuring the angular displacement of a point of interest on a structure, such as aircraft model within a wind tunnel, includes a source of polarized light located at the point of interest. A remote detector arrangement detects the orientation of the plane of the polarized light received from the source and compares this orientation with the initial orientation to determine the amount or rate of angular displacement of the point of interest. The detector arrangement comprises a rotating polarizing filter and a dual filter and light detector unit. The latter unit comprises an inner aligned filter and photodetector assembly which is disposed relative to the periphery of the polarizer so as to receive polarized light passing the polarizing filter and an outer aligned filter and photodetector assembly which receives the polarized light directly, i.e., without passing through the polarizing filter. The purpose of the unit is to compensate for the effects of dust, fog and the like. A polarization preserving optical fiber conducts polarized light from a remote laser source to the point of interest.

Seegmiller, H. Lee B.↗