At least 1,171 records · Page 65

Supplemental multilayer insulation research facility

The Supplemental Multilayer Insulation Research Facility (SMIRF) provides a small scale test bed for conducting cryogenic experiments in a vacuum environment. The facility vacuum system is capable of simulating a Space Shuttle launch pressure profile as well as providing a steady space vacuum environment of 1.3 x 10(exp -4) Newton/sq meter (1 x 10(exp -6) torr). Warm side boundary temperatures can be maintained constant between 111 K (200 R) and 361 K (650 R) using a temperature controlled shroud. The shroud can also simulate a typical lunar day-night temperature profile. The test hardware consists of a cryogenic calorimeter supported by the lid of the vacuum chamber. A 0.45 cu meter (120 gallon) vacuum jacketed storage/supply tank is available for conditioning the cryogen prior to use in the calorimeter. The facility was initially designed to evaluate the thermal performance of insulation systems for long-term storage in space. The facility has recently been used to evaluate the performance of various new insulation systems for LH2 and LN2 ground storage dewars.

Dempsey, P. J.↗

Experimental Characterization of Hysteresis in a Revolute Joint for Precision Deployable Structures

Recent studies of the micro-dynamic behavior of a deployable telescope metering truss have identified instabilities in the equilibrium shape of the truss in response to low-energy dynamic loading. Analyses indicate that these micro-dynamic instabilities arise from stick-slip friction within the truss joints (e.g., hinges and latches). The present study characterizes the low-magnitude quasi-static load cycle response of the precision revolute joints incorporated in the deployable telescope metering truss, and specifically, the hysteretic response of these joints caused by stick-slip friction within the joint. Detailed descriptions are presented of the test setup and data reduction algorithms, including discussions of data-error sources and data-filtering techniques. Test results are presented from thirteen specimens, and the effects of joint preload and manufacturing tolerances are investigated. Using a simplified model of stick-slip friction, a relationship is made between joint load-cycle behavior and micro-dynamic dimensional instabilities in the deployable telescope metering truss.

Lake, Mark S.↗

Electromagnetic propulsion test facility

A test facility for the exploration of electromagnetic propulsion concept is described. The facility is designed to accommodate electromagnetic rail accelerators of various lengths (1 to 10 meters) and to provide accelerating energies of up to 240 kiloJoules. This accelerating energy is supplied as a current pulse of hundreds of kiloAmps lasting as long as 1 millisecond. The design, installation, and operating characteristics of the pulsed energy system are discussed. The test chamber and its operation at pressures down to 1300 Pascals (10 mm of mercury) are described. Some aspects of safety (interlocking, personnel protection, and operating procedures) are included.

Gooder, S. T.↗

Bio-Inspired Cyber Security for Smart Grid Deployments

mart grid technologies are transforming the electric power grid into a grid with bi-directional flows of both power and information. Operating millions of new smart meters and smart appliances will significantly impact electric distribution systems resulting in greater efficiency. However, the scale of the grid and the new types of information transmitted will potentially introduce several security risks that cannot be addressed by traditional, centralized security techniques. We propose a new bio-inspired cyber security approach. Social insects, such as ants and bees, have developed complex-adaptive systems that emerge from the collective application of simple, light-weight behaviors. The Digital Ants framework is a bio-inspired framework that uses mobile light-weight agents. Sensors within the framework use digital pheromones to communicate with each other and to alert each other of possible cyber security issues. All communication and coordination is both localized and decentralized thereby allowing the framework to scale across the large numbers of devices that will exist in the smart grid. Furthermore, the sensors are light-weight and therefore suitable for implementation on devices with limited computational resources. This paper will provide a brief overview of the Digital Ants framework and then present results from test bed-based demonstrations that show that Digital Ants can identify a cyber attack scenario against smart meter deployments.

McKinnon, Archibald D.↗

Wind Tunnel Testing for the Stratospheric Observatory for Infrared Astronomy

NASA Ames Research Center is pursuing the development of SOFIA, the Stratospheric Observatory For Infrared Astronomy. SOFIA will consist of a 2.5 meter telescope mounted aft of the wing of a Boeing 747 aircraft. Since a large portion of the infrared spectrum is not visible at ground level due to absorption by water vapor in the atmosphere below 40,000 feet, it is highly desirable to make observations above this altitude. SOFIA will provide the opportunity for astronomers to conduct high-altitude research for extended periods of time. Current study is focused on wind tunnel testing for the open cavity. If not controlled, air would create resonance and damage the telescope. For this reason, SOFIA will design a boundary layer control device to achieve laminar flow over the cavity. This also provides a clearer flow for seeing, thus improving resolution on infrared sources. Other effects being tested in the wind tunnel are aerodynamic torque loads on the telescope, and flutter loads on the tail.

Schenberger, Deborah↗

Homogeneity of a Global Multisatellite Soil Moisture Climate Data Record

Climate Data Records (CDR) that blend multiple satellite products are invaluable for climate studies, trend analysis and risk assessments. Knowledge of any inhomogeneities in the CDR is therefore critical for making correct inferences. This work proposes a methodology to identify the spatiotemporal extent of the inhomogeneities in a 36-year, global multisatellite soil moisture CDR as the result of changing observing systems. Inhomogeneities are detected at up to 24 percent of the tested pixels with spatial extent varying with satellite changeover times. Nevertheless, the contiguous periods without inhomogeneities at changeover times are generally longer than 10 years. Although the inhomogeneities have measurable impact on the derived trends, these trends are similar to those observed in ground data and land surface reanalysis, with an average error less than 0.003 cubic meters per cubic meter per year. These results strengthen the basis of using the product for long-term studies and demonstrate the necessity of homogeneity testing of multisatellite CDRs in general.

CDR↗

Investigation of gas hydrate-bearing sandstone reservoirs at the "Mount Elbert" stratigraphic test well, Milne Point, Alaska

In February 2007, the U.S. Department of Energy, BP Exploration (Alaska), Inc., and the U.S. Geological Survey conducted an extensive data collection effort at the "Mount Elbert #1" gas hydrates stratigraphic test well on the Alaska North Slope (ANS). The 22-day field program acquired significant gas hydrate-bearing reservoir data, including a full suite of open-hole well logs, over 500 feet of continuous core, and open-hole formation pressure response tests. Hole conditions, and therefore log data quality, were excellent due largely to the use of chilled oil-based drilling fluids. The logging program confirmed the existence of approximately 30 m of gashydrate saturated, fine-grained sand reservoir. Gas hydrate saturations were observed to range from 60% to 75% largely as a function of reservoir quality. Continuous wire-line coring operations (the first conducted on the ANS) achieved 85% recovery through 153 meters of section, providing more than 250 subsamples for analysis. The "Mount Elbert" data collection program culminated with open-hole tests of reservoir flow and pressure responses, as well as gas and water sample collection, using Schlumberger's Modular Formation Dynamics Tester (MDT) wireline tool. Four such tests, ranging from six to twelve hours duration, were conducted. This field program demonstrated the ability to safely and efficiently conduct a research-level openhole data acquisition program in shallow, sub-permafrost sediments. The program also demonstrated the soundness of the program's pre-drill gas hydrate characterization methods and increased confidence in gas hydrate resource assessment methodologies for the ANS.

03 NATURAL GAS↗

Recent Developments in the Alignment and Test Plans for the James Webb Space Telescope Integrated Science Instrument Module

The James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (approximately 40K). The JWST Observatory architecture includes the Optical Telescope Element (OTE) and the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. The SIs and Guider are mounted to a composite metering structure with outer dimensions of 2.1 x 2.2 x 1.9m. The SI and Guider units are integrated to the ISIM structure and optically tested at NASA/Goddard Space Flight Center as an instrument suite using an OTE SIMulator (OSIM). OSIM is a high-fidelity, cryogenic JWST telescope simulator that features a approximately 1.5m diameter powered mirror. The SIs are aligned to the structure's coordinate system under ambient, clean room conditions using laser tracker and theodolite metrology. Temperature-induced mechanical SI alignment and structural changes are measured using a photogrammetric measurement system at ambient and cryogenic temperatures. OSIM is aligned to the ISIM mechanical coordinate system at the cryogenic operating temperature via internal mechanisms and feedback from alignment sensors in six degrees of freedom. SI performance, including focus, pupil shear and wavefront error, is evaluated at the operating temperature using OSIM. We present an updated plan for the assembly and ambient and cryogenic optical alignment, test and verification of the ISIM element.

Ohl, Raymond↗

Testing a Model of Planck-Scale Quantum Geometry With Broadband Correlation of Colocated 40m Interferometers

The Holometer is designed to test for a Planck diffractive-scaling uncertainty in long-baseline position measurements due to an underlying noncommutative geometry normalized to relate Black hole entropy bounds of the Holographic principle to the now-finite number of position states. The experiment overlaps two independent 40 meter optical Michelson interferometers to detect the proposed uncertainty as a common broadband length fluctuation. 150 hours of instrument cross-correlation data are analyzed to test the prediction of a correlated noise magnitude of $7\times10^{−21}$ m/$\sqrt{\rm Hz}$ with an effective bandwidth of 750kHz. The interferometers each have a quantum-limited sensitivity of $2.5\times 10^{−18}$ m/$\sqrt{\rm Hz}$, but their correlation with a time-bandwidth product of $4\times 10^{11}$ digs between the noise floors in search for the covarying geometric jitter. The data presents an exclusion of 5 standard deviations for the tested model. This exclusion is defended through analysis of the calibration methods for the instrument as well as further sub shot noise characterization of the optical systems to limit spurious background-correlations from undermining the signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Full-scale wind-tunnel tests of a small unpowered jet aircraft with a T-tail

The aerodynamic characteristics of a full scale executive type jet transport aircraft with a T-tail were investigated in a 40 x 80 ft (12.2 by 24.4 meter) wind tunnel (subsonic). Static, longitudinal, and lateral stability, and control characteristics were determined at angles of attack from -2 deg to +42 deg. The aircraft wing had 13 deg of sweep and an aspect ratio of 5.02. The aircraft was tested power off with various wing leading- and trailing-edge high lift devices. The basic configuration was tested with and without such components as engine nacelles, wing tip tanks, and empannage. Hinge-moment data were obtained and downwash angles in the horizontal-tail plane location were calculated. The data were obtained at Reynolds numbers of 4.1 million and 8.7 million based on mean aerodynamic chord. The model had static longitudinal stability through initial stall. Severe tail buffet occurred near the angle of attack for maximum lift. Above initial stall the aircraft had pronounced pitch-up, characteristic of T-tail configurations. A stable trim point was possible at angles of attack between 30 deg and 40 deg (depending on c.g. location and flap setting). Hinge-moment data showed no regions with adverse effects on stick force. Comparisons of wind-tunnel data and flight-test are presented.

Soderman, P. T.↗

Reservoir response to thermal and high-pressure well stimulation efforts at Raft River, Idaho

An injection stimulation test begun at the Raft River geothermal reservoir in June, 2013 has produced a wealth of data describing well and reservoir response via high-resolution temperature logging and distributed temperature sensing, seismic monitoring, periodic borehole televiewer logging, periodic stepped flow rate tests and tracer injections before and after stimulation efforts. One of the primary measures of response to the stimulation is the relationship between fluid pressure and flow rate, short-term during forced flow rate changes and the long-term change in injectivity. In this paper we examine that hydraulic response using standard pumping test analysis methods, largely because pressure response to the stimulation was not detected, or measurable, in other wells. Analysis of stepped rate flow tests supports the inference from other data that a large fracture, with a radial extent of one to several meters, intersects the well in the target reservoir, suggests that the flow regime is radial to a distance of only several meters and demonstrates that the pressure build-up cone reaches an effective constant head at that distance. The well’s longer term hydraulic response demonstrated continually increasing injectivity but at a dramatically faster rate later from ~2 years out and continuing to the present. The net change in injectivity is significantly greater than observed in other longterm injectivity monitoring studies, with an approximately 150–fold increase occurring over ~2.5 years. While gradually increasing injectivity is a likely consequence of slow migration of a cooling front, and consequent dilation of fractures, the steady, ongoing, rate of increase is contrary to what would be expected in a radial or linear flow regime, where the cooling front would slow with time. As a result, occasional step-like changes in injectivity, immediately following high-flow rate tests suggest that hydro shearing during high-pressure testing altered the near-well permeability structure.

15 GEOTHERMAL ENERGY↗

Theoretical and Experimental Thermal Performance Analysis of Complex Thermal Storage Membrane Containing Bio-Based Phase Change Material (PCM)

Since 2000, an ORNL research team has been testing different configurations of PCM-enhanced building envelop components to be used in residential and commercial buildings. During 2009, a novel type of thermal storage membrane was evaluated for building envelope applications. Bio-based PCM was encapsulated between two layers of heavy-duty plastic film forming a complex array of small PCM cells. Today, a large group of PCM products are packaged in such complex PCM containers or foils containing arrays of PCM pouches of different shapes and sizes. The transient characteristics of PCM-enhanced building envelope materials depend on the quality and amount of PCM, which is very often difficult to estimate because of the complex geometry of many PCM heat sinks. The only widely used small-scale analysis method used to evaluate the dynamic characteristics of PCM-enhanced building products is the differential scanning calorimeter (DSC). Unfortunately, this method requires relatively uniform, and very small, specimens of the material. However, in numerous building thermal storage applications, PCM products are not uniformly distributed across the surface area, making the results of traditional DSC measurements unrealistic for these products. In addition, most of the PCM-enhanced building products contain blends of PCM with fire retardants and chemical stabilizers. This combination of non-uniform distribution and non-homogenous composition make it nearly impossible to select a representative small specimen suitable for DSC tests. Recognizing these DSC limitations, ORNL developed a new methodology for performing dynamic heat flow analysis of complex PCM-enhanced building materials. An experimental analytical protocol to analyze the dynamic characteristics of PCM thermal storage makes use of larger specimens in a conventional heat-flow meter apparatus, and combines these experimental measurements with three-dimensional (3-D) finite-difference modeling and whole building energy simulations. Based on these dynamic tests and modeling, ORNL researchers then developed a simplified one-dimensional (1-D) model of the PCM-enhanced building component that can be easily used in whole-building simulations. This paper describes this experimental-analytical methodology as used in the analysis of an insulation assembly containing a complex array of PCM pouches. Based on the presented short example of whole building energy analysis, this paper describes step-by-step how energy simulation results can be used for optimization of PCM-enhanced building envelopes. Limited results of whole building energy simulations using the EnergyPlus program are presented as well.

25 ENERGY STORAGE↗

Convergence of Emerging Technologies - Blickfeld Test Results

The Blickfeld Cube 1 Lidar is an inexpensive flash lidar being developed for autonomous navigation with an advertised maximum range of 75 meters that uses a Class 1 eye-safe laser. Figure 1 shows an example of the installation of the Cube 1 lidar and Figure 2 shows an example of the point cloud generated, with the red circle indicating an intruder. The Cube 1 lidar has a software adjustable field of view and as many as 5 lidars can be stitched together. (Figure 2 shows two Cube 1 lidars stitched together.)

47 OTHER INSTRUMENTATION↗

The feasibility of a fluidic respiratory flow meter

A study was undertaken to determine the feasibility of adapting a fluidic airspeed sensor for use as a respiratory flowmeter. A Pulmonary Function Testing Flowmeter was developed which should prove useful for mass screening applications. The fluidic sensor threshold level was not reduced sufficiently to permit its adaptation to measuring the low respiratory flow rates encountered in many respiratory disorders.

Neradka, V. F.↗

Pick and Eat Crop Testing: Dwarf Tomato and Pepper as Candidate Space Crops

Several dwarf tomato and pepper varieties were evaluated under International Space Station (ISS)-simulated growth conditions (22 degrees Centigrade, 50 percent relative humidity, 1500 parts per million CO2, and 300 micromoles per square meter per second of light for 16 hours per day) with the goal of selecting those with the best growth, nutrition, and organoleptic potential for use in a pick and eat salad crop system on ISS and future exploration flights. Testing included six cultivars of tomato (Red Robin, Scarlet Sweet 'N' Neat, Tiny Tim, Mohamed, Patio Princess, and Tumbler) and six cultivars of pepper (Red Skin, Fruit Basket, Cajun Belle, Chablis, Sweet Pickle, and Pompeii). Plants were grown to an age sufficient to produce fruit (up to 106 days for tomato and 109 days for pepper) using Turface (arcillite) potting media with 18-6-8 control-release fertilizer and supplemental nutrient solution beginning around 60-days-age. Tomato fruits were harvested when they showed full red color, beginning around 70-days age and then at weekly intervals thereafter, while peppers were grown until fruits showed color and were harvested twice (first test) and just once at the end of the second test, with the final harvests including colored and green fruit. Plant sizes, yields, and nutritional attributes were measured and used to down-select to three cultivars for each species. In particular, we were interested in cultivars that were short (dwarf) but still produced high yields. Nutritional data included elemental (Ca, Mg, Fe, and K) content, vitamin K, phenolics, lycopene (for tomato), anthocyanin, lutein, and zeaxanthin. The three down-selected cultivars for each species were grown again and the harvested fruit sent to NASA's Johnson Space Center for sensory evaluation, which included overall acceptability, appearance, color intensity, aroma, flavor and texture. The combined data were compared and given weighting factors to rank the cultivars as candidates for testing in space. Weightings gave maximum importance to plant size (smaller being good) and fruit yield (greater yields being good). For tomato, the ranking was 1) cultivar Mohamed and cultivar Red Robin (tied), and 3) cultivar Sweet N' Neat. For pepper, the ranking was 1) cultivar Pompeii, 2) cultivar Red Skin, and 3) cultivar Fruit Basket. These rankings are somewhat subjective but provide a starting point for conducting higher fidelity testing with these crops (e.g., testing with light emitting diode lighting similar to the Veggie plant unit on ISS), and ultimately conducting a flight experiment.

Food↗

SHERPA Electromechanical Test Bed

SHERPA (Strap-on High-altitude Entry Reconnaissance and Precision Aeromaneuver system) is a concept for low-cost-high-accuracy Martian reentry guidance for small scout-class missions with a capsule diameter of approximately 1 meter. This system uses moving masses to change the center of gravity of the capsule in order to control the lift generated by the controlled imbalance. This project involved designing a small proof-of-concept demonstration system that can be used to test the concept through bench-top testing, hardware-in-the-loop testing, and eventually through a drop test from a helicopter. This project has focused on the Mechatronic design aspects of the system including the mechanical, electrical, computer, and low-level control of the concept demonstration system.

Wason, John D.↗

Laser Tracker Test Facility at SLAC - Progress Report

Physics experiments at SLAC require high accuracy positioning, e. g. 100 {micro}m over a distance of 150 m or 25 {micro}m in a 10 x 10 x 3 meter volume. Laser Tracker measurement systems have become one of the most important tools for achieving these accuracies when mapping components. In order to improve and get a better understanding of laser tracker measurement tolerances we extended our laboratory with a rotary calibration table (Kugler GmbH) providing an accuracy of better than 0.2 arcsec. This paper gives an overview of the calibration table and its evaluation. Results of tests on two of our Laser Trackers utilizing the new rotary table as well as the SLAC interferometer bench are presented.

43 PARTICLE ACCELERATORS↗