Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material point method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Electronic structure and magnetic properties of FeWO{sub 4} nanocrystals synthesized by the microwave-hydrothermal method

This communication reports that FeWO{sub 4} nanocrystals were successfully synthesized by the microwave-hydrothermal method at 443 K for 1 h. The structure and shape of these nanocrystals were characterized by X-ray diffraction, Rietveld refinement, and transmission electron microscopy. The experimental results and first principles calculations were combined to explain the electronic structure and magnetic properties. Experimental data were obtained by magnetization measurements for different applied magnetic fields. Theoretical calculations revealed that magnetic properties of FeWO{sub 4} nanocrystals can be assigned to two magnetic orderings with parallel or antiparallel spins in adjacent chains. These factors are crucial to understanding of competition between ferro- and antiferromagnetic behavior. Highlights: Black-Right-Pointing-Pointer Monophasic FeWO{sub 4} nanocrystals were synthesized by the microwave-hydrothermal method. Black-Right-Pointing-Pointer Rietveld refinement and clusters model for monoclinic structure Black-Right-Pointing-Pointer Magnetic properties of FeWO{sub 4} nanocrystals at different temperatures.

36 MATERIALS SCIENCE↗

Verification of 2-D Detonation Shock Dynamics in conjunction with Los Alamos Lagrangian hydrocode

As the latest version of the fast-tube Detonation Shock Dynamics (DSD) solver is linked with the Los Alamos Lagrangian hydrocode, verification problems from a 2006 DSD report (LA-14277) have been duplicated with some of the verification criteria changed to more quantitative ones. The observed error convergence is as good as or better than reported in, quite possibly due to the careful treatment of floating point numbers to ensure that their precision level is maintained throughout the code. This report duplicates the three sample verification problems in LA-14277 using the Los Alamos ASC Lagrangian hydrocode (FLAG), official release of 3.2 Alpha6 with a few modifications. This version of FLAG is linked with the latest fast-tube Detonation Shock Dynamics (DSD) version beta 2 solver released in 2011 as part of the LanlDSD software product. New verification criteria are used for the arcwave problem where two specific locations are chosen for burn arrival time comparison. For this report FLAG's internal driver code prepares the distance function ({Psi}) and material ID fields from its hydro setup, instead of the stand-alone driver that is being utilized by the other LANL hydrocodes currently interfaced to LanlDSD. As it is implemented in version 3.2 Alpha6, the {Psi} and material ID fields and other parameters are passed from FLAG to the DSD solver directly, and the burn table is directly passed back to FLAG as part of the calling arguments. The burn-front arrival time 'exact' solutions, mentioned in the sequel for the rate-stick and 'arc-wave' problems, are computed using a pair of special-purpose Fortran codes provided by Aslam. In each case an ansatz for the form of the solution is made in which the radius from the detonator center point is used as the independent space coordinate. This leads to a simplified, problem-specific, 1D form of the governing equation. This equation is solved using 2nd-order spatial differencing and the forward Euler method on a very fine temporal and geometric mesh. The boundary conditions are handled exactly at the correct location, with second order accuracy. Care has been taken to ensure that this solution is fully converged.

36 MATERIALS SCIENCE↗

Effect of nitrogen plasma power on defect levels in Ni/n-GaN Schottky diodes grown by molecular beam epitaxy

The incorporation of deep level defects in n-type GaN grown by plasma assisted molecular beam epitaxy was studied via systematic adjustment of the nitrogen plasma source power from 150 to 400 W while maintaining a constant V/III beam flux ratio. Deep level optical spectroscopy and conventional thermal deep level transient spectroscopy measurements, which together enable deep level detection throughout the GaN band gap, revealed several deep level concentrations that depend strongly on rf-plasma power. The concentrations of the gallium vacancy deep level at E{sub C}-2.60 eV and carbon-related point defects with energy levels at E{sub C}-3.28 and E{sub C}-1.35 eV are found to be very sensitive to the nitrogen source power, increasing by up to 50 times for a corresponding increase in plasma power from 150 to 400 W. The relation between the concentrations of these traps and plasma power follows an Arrhenius-type behavior and is suggestive of plasma damage associated with the energetics of the constituent active nitrogen species. In contrast, two traps at E{sub C}-0.86 and E{sub C}-0.59 eV did not exhibit a systematic dependence on plasma power, with this difference a result of the dislocation-related nature of these defects.

36 MATERIALS SCIENCE↗

Anatomy-Based Inverse Planning Simulated Annealing Optimization in High-Dose-Rate Prostate Brachytherapy: Significant Dosimetric Advantage Over Other Optimization Techniques

Purpose: To perform an independent validation of an anatomy-based inverse planning simulated annealing (IPSA) algorithm in obtaining superior target coverage and reducing the dose to the organs at risk. Method and Materials: In a recent prostate high-dose-rate brachytherapy protocol study by the Radiation Therapy Oncology Group (0321), our institution treated 20 patients between June 1, 2005 and November 30, 2006. These patients had received a high-dose-rate boost dose of 19 Gy to the prostate, in addition to an external beam radiotherapy dose of 45 Gy with intensity-modulated radiotherapy. Three-dimensional dosimetry was obtained for the following optimization schemes in the Plato Brachytherapy Planning System, version 14.3.2, using the same dose constraints for all the patients treated during this period: anatomy-based IPSA optimization, geometric optimization, and dose point optimization. Dose-volume histograms were generated for the planning target volume and organs at risk for each optimization method, from which the volume receiving at least 75% of the dose (V{sub 75%}) for the rectum and bladder, volume receiving at least 125% of the dose (V{sub 125%}) for the urethra, and total volume receiving the reference dose (V{sub 100%}) and volume receiving 150% of the dose (V{sub 150%}) for the planning target volume were determined. The dose homogeneity index and conformal index for the planning target volume for each optimization technique were compared. Results: Despite suboptimal needle position in some implants, the IPSA algorithm was able to comply with the tight Radiation Therapy Oncology Group dose constraints for 90% of the patients in this study. In contrast, the compliance was only 30% for dose point optimization and only 5% for geometric optimization. Conclusions: Anatomy-based IPSA optimization proved to be the superior technique and also the fastest for reducing the dose to the organs at risk without compromising the target coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diffusion Behavior of Oversized Fission Products in bcc Fe Cladding: A First-Principles Study

Fuel-Cladding Chemical Interaction (FCCI) poses significant challenges in nuclear reactors, where fission products from nuclear fuel interact with Fe-based cladding materials, potentially compromising their structural integrity. This study investigates the diffusion behavior of oversized fission products, Pr, Nd, Ce, and La, within bcc Fe cladding using density functional theory (DFT), nudged elastic band (NEB) method, and self-consistent mean field (SCMF) theory. Our results reveal significant long-range vacancy binding energies, particularly up to the 6th nearest neighbor, with La exhibiting the strongest binding affinity, followed by Nd, Ce, and Pr. The NEB calculations indicate significant high barriers for the dissociation of 1nn vacancy-solute pairs for all fission products. The tracer diffusion coefficients of these fission products was derived in Arrhenius form. The significant trapping effect of vacancies by a very dilute amount of fission products reduces vacancy mobility, leading to an oversaturation of point defects, void nucleation, and swelling. These are critical issues for irradiated cladding materials. The tracer diffusion coefficients indicate that Nd diffuses the fastest, followed by La, Ce, and Pr. This study provides essential insights for developing advanced cladding materials and design strategies to mitigate FCCI, ultimately enhancing nuclear reactor safety and performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calculating Hugoniots for molecular crystals from first principles.

Density Functional Theory (DFT) has over the last few years emerged as an indispensable tool for understanding the behavior of matter under extreme conditions. DFT based molecular dynamics simulations (MD) have for example confirmed experimental findings for shocked deuterium, enabled the first experimental evidence for a triple point in carbon above 850 GPa, and amended experimental data for constructing a global equation of state (EOS) for water, carrying implications for planetary physics. The ability to perform high-fidelity calculations is even more important for cases where experiments are impossible to perform, dangerous, and/or prohibitively expensive. For solid explosives, and other molecular crystals, similar success has been severely hampered by an inability of describing the materials at equilibrium. The binding mechanism of molecular crystals (van der Waals forces) is not well described within traditional DFT. Among widely used exchange-correlation functionals, neither LDA nor PBE balances the strong intra-molecular chemical bonding and the weak inter-molecular attraction, resulting in incorrect equilibrium density, negatively affecting the construction of EOS for undetonated high explosives. We are exploring a way of bypassing this problem by using the new Armiento-Mattsson 2005 (AM05) exchange-correlation functional. The AM05 functional is highly accurate for a wide range of solids, in particular in compression. In addition, AM05 does not include any van der Waals attraction, which can be advantageous compared to other functionals: Correcting for a fictitious van der Waals like attraction with unknown origin can be harder than correcting for a complete absence of all types of van der Waals attraction. We will show examples from other materials systems where van der Waals attraction plays a key role, where this scheme has worked well, and discuss preliminary results for molecular crystals and explosives.

36 MATERIALS SCIENCE↗

Defective Carbon-Based Materials for the Electrochemical Synthesis of Hydrogen Peroxide

Hydrogen peroxide (H 2 O 2 ), an important industrial chemical, is currently produced through an energy-intensive anthraquinone process that is limited to large-scale facilities. Small-scale decentralized electrochemical production of H 2 O 2 via a two-electron oxygen reduction reaction (ORR) offers unique opportunities for sanitization applications and the purification of drinking water. The development of inexpensive, efficient, and selective catalysts for this reaction remains a challenge. Here in this paper, we examine two different porous carbon-based electrocatalysts and show that they exhibit high selectivity for H 2 O 2 under alkaline conditions. By rationally varying synthetic methods, we explore the effect of pore size on electrocatalytic performance. Furthermore, by means of density functional calculations, we point out the critical role of carbon defects. Our theory results show that the majority of defects in graphene are naturally selective for the two-electron reduction of O 2 to H 2 O 2 , and we identify the types of defects with high activity.

36 MATERIALS SCIENCE↗

Aqueous Chemistry in the Diamond Anvil Cell up to and Beyond the Critical Point of Water

The hydrothermal diamond anvil cell (HDAC) has been developed for the study of fluids and their interactions with other phases. It is capable of pressures up to 10 GPa and temperatures from -190 C to 1200 C. It has found application in studies of equations of state of fluids, reactions between fluids and solids as well as fluids and melts, hydration and dehydration of hydrous solids under P{sub H2O}, fractionation of species between fluids and solids as well as fluids and melts, the effect of P{sub H2O} on melting of silicates, structures of ions and clathrates in solution, preservation of hosts of fluid inclusions at high temperatures, and reactions in clathrates and other organic materials. Visual, spectroscopic, and X-ray methods are used to analyze samples by taking advantage of the exceptional transparency of the diamond anvils. Examples of successful apphcations of the HDAC include the equation of state (EOS) of water, stability of the various stages of hydration of montmorillonite and calcium carbonate, leaching of elements from zircon, the effect of P{sub H2O} on the melting of albite, speciation and structures of Sc, Fe, Cu, Zn, Y, La, Yb, and Br in solution, stability of methane hydrates and Ca(OH){sub 2}, identifying a new H{sub 2}O ice form and sll of methane hydrate. The description of diamond cell configuration, analytical methods, and examples of applications provide evidence of the utility of the technique for many studies of fluids at temperatures and pressures up to and beyond the critical point of water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Secondary Neutron Doses for Several Beam Configurations for Proton Therapy

Purpose: To compare possible neutron doses produced in scanning and scattering modes, with the latter assessed using a newly built passive-scattering proton beam line. Methods and Materials: A 40 x 30.5 x 30-cm water phantom was irradiated with 230-MeV proton beams using a gantry angle of 270{sup o}, a 10-cm-diameter snout, and a brass aperture with a diameter of 7 cm and a thickness of 6.5 cm. The secondary neutron doses during irradiation were measured at various points using CR-39 detectors, and these measurements were cross-checked using a neutron survey meter with a 22-cm range and a 5-cm spread-out Bragg peak. Results: The maximum doses due to secondary neutrons produced by a scattering beam-delivery system were on the order of 0.152 mSv/Gy and 1.17 mSv/Gy at 50 cm from the beam isocenter in the longitudinal (0{sup o}) and perpendicular (90{sup o}) directions, respectively. The neutron dose equivalent to the proton absorbed dose, measured from 10 cm to 100 cm from the isocenter, ranged from 0.071 mSv/Gy to 1.96 mSv/Gy in the direction of the beam line (i.e., {phi} = 0 deg.). The largest neutron dose, of 3.88 mSv/Gy, was observed at 135{sup o} and 25 cm from the isocenter. Conclusions: Although the secondary neutron doses in proton therapy were higher when a scattering mode rather than a scanning mode was used, they did not exceed the scattered photon dose in typical photon treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combination of the Pro-Apoptotic TRAIL-Receptor Antibody Mapatumumab With Ionizing Radiation Strongly Increases Long-Term Tumor Control Under Ambient and Hypoxic Conditions

Purpose: Mapatumumab, an agonistic tumor necrosis factor-related apoptosis inducing ligand-receptor antibody, exerts highly synergistic apoptotic effects in vitro and in short-term growth delay assays when combined with irradiation. Because it remained unclear in how far these effects influence local tumor control, long-term experiments using a colorectal xenograft model were undertaken. Material and Methods: Experiments were performed with irradiation (5 x 3 Gy, d1-5) and mapatumumab (10 mg/kg) in Colo205-xenograft-bearing NMRI (nu/nu) nude mice. Graded top up doses were delivered on the tumor-bearing hind leg under ambient and hypoxic conditions; follow-up was 270 days. Growth delay and local tumor control were end points of the study. Statistical analysis of the experiments included calculation of tumor regrowth and local tumor control. Results: After combined treatment, a pronounced tumor regrowth-delay was observed when compared with irradiation alone. Long-term experiments revealed a highly significant increase in local tumor control for ambient (p = 0.00076) and hypoxic treatment (p = 0.000069). Conclusions: The present data demonstrate for the first time that combination of a pro-apoptotic antibody with irradiation results in evidently reduced tumor regrowth times and subsequently highly increased local tumor control under normoxic and hypoxic conditions in a xenograft mouse model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Results of a Multi-Institution Deformable Registration Accuracy Study (MIDRAS)

Purpose: To assess the accuracy, reproducibility, and computational performance of deformable image registration algorithms under development at multiple institutions on common datasets. Methods and Materials: Datasets from a lung patient (four-dimensional computed tomography [4D-CT]), a liver patient (4D-CT and magnetic resonance imaging [MRI] at exhale), and a prostate patient (repeat MRI) were obtained. Radiation oncologists localized anatomic structures for accuracy assessment. Algorithm accuracy was determined by comparing the computer-predicted displacement at each bifurcation point with the displacement computed from the oncologists' annotations. Thirty-seven academic institutions and medical device manufacturers with published evidence of active deformable image registration capabilities were invited to participate. Results: Twenty-seven groups agreed to participate; 6 did not return results. Sixteen completed the liver 4D-CT, 12 the lung 4D-CT, 3 the prostate MRI, and 3 the liver MRI-CT. The range of average absolute error for the lung 4D-CT was 0.6-1.2 mm (left-right [LR]), 0.5-1.8 mm (anterior-posterior [AP]), and 0.7-2.0 mm (superior-inferior [SI]); the liver 4D-CT was 0.8-1.5 mm (LR), 1.0-5.2 mm (AP), and 1.0-5.9 mm (SI); the liver MRI-CT was 1.1-2.6 mm (LR), 2.0-5.0 mm (AP), and 2.2-2.6 mm (SI); and the repeat prostate MRI prostate datasets was 0.5-6.2 mm (LR), 3.1-3.7 mm (AP), and 0.4-2.0 mm (SI). Conclusions: An infrastructure was developed to assess multi-institution deformable registration accuracy. The results indicate large discrepancies in reported shifts, although the majority of deformable registration algorithms performed at an accuracy equivalent to the voxel size, promising to improve treatment planning, delivery, and assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final Results of a Prospective Study Comparing the Local Control of Short-Course and Long-Course Radiotherapy for Metastatic Spinal Cord Compression

Purpose: Many patients with metastatic spinal cord compression (MSCC) live long enough to develop a recurrence in the irradiated spinal area. This is the first prospective study that has compared local control of different radiotherapy schedules for MSCC. Methods and Materials: A total of 265 patients treated with radiotherapy alone were included in this prospective nonrandomized study. The primary goal was to compare local control from short-course (1 x 8 Gy/5 x 4 Gy, n = 131) and long-course radiotherapy (10 x 3 Gy/15 x 2.5 Gy/20 x 2 Gy, n = 134). Secondary end points were motor function and survival. The analysis of local control (no MSCC recurrence in the irradiated spinal area) included the 224 patients with improvement or no change of motor deficits during radiotherapy. Eleven additional factors were evaluated for outcomes. Results: One-year local control was 61% after short-course and 81% after long-course radiotherapy (p = 0.005). On multivariate analysis (MVA), improved local control was associated with long-course radiotherapy (p = 0.018). Motor function improved in 37% after short-course and 39% after long-course radiotherapy (p = 0.95). Improved motor function was associated with better performance status (p = 0.015), favorable tumor type (p = 0.034), and slower development of motor deficits (p < 0.001). One-year survival rates were 23% after short-course and 30% after long-course radiotherapy (p = 0.28). On MVA, improved survival was associated with better performance status (p < 0.001), no visceral metastases (p < 0.001), involvement of only one to three vertebrae (p = 0.040), ambulatory status (p = 0.038), and bisphosphonate administration after radiotherapy (p < 0.001). Conclusions: Long-course radiotherapy was associated with better local control, similar functional outcome, and similar survival compared to short-course radiotherapy. Patients with a relatively favorable expected survival should receive long-course radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of HER2-Expressing Breast Cancer and Ovarian Cancer Cells With Alpha Particle-Emitting {sup 227}Th-Trastuzumab

Purpose: To evaluate the cytotoxic effects of low-dose-rate alpha particle-emitting radioimmunoconjugate {sup 227}Th-p-isothiocyanato-benzyl-DOTA-trastuzumab ({sup 227}Th-trastuzumab [where DOTA is 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid]) internalized by breast and ovarian cancer cell lines in order to assess the potential of {sup 227}Th-trastuzumab as a therapeutic agent against metastatic cancers that overexpress the HER2 oncogene. Methods and Materials: Clonogenic survival and cell growth rates of breast cancer cells treated with {sup 227}Th-trastuzumab were compared with rates of cells treated with nonbinding {sup 227}Th-rituximab, cold trastuzumab, and X-radiation. Cell growth experiments were also performed with ovarian cancer cells. Cell-associated radioactivity was measured at several time points, and the mean radiation dose to cells was calculated. Results: SKBR-3 cells got 50% of the mean absorbed radiation dose from internalized activity and 50% from cell surface-bound activity, while BT-474 and SKOV-3 cells got 75% radiation dose from internalized activity and 25% from cell surface-bound activity. Incubation of breast cancer cells with 2.5 kBq/ml {sup 227}Th-trastuzumab for 1 h at 4{sup o}C, followed by washing, resulted in mean absorbed radiation doses of 2 to 2.5 Gy. A dose-dependent inhibition of cell growth and an increase in apoptosis were induced in all cell lines. Conclusions: Clinically relevant activity concentrations of {sup 227}Th-trastuzumab induced a specific cytotoxic effect in three HER2-expressing cell lines. The cytotoxic effect of {sup 227}Th-trastuzumab was higher than that of single-dose X-radiation (relative biological effectiveness = 1.2). These results warrant further studies of treatment of breast cancer and ovarian cancer with {sup 227}Th-trastuzumab.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Liver Function After Proton Beam Therapy for Hepatocellular Carcinoma

Purpose: Our previous results for treatment of hepatocellular carcinoma with proton beam therapy (PBT) revealed excellent local control. In this study, we focused on the impact of PBT on normal liver function. Methods and Materials: The subjects were 259 patients treated with PBT at University of Tsukuba between January 2001 and December 2007. We evaluated the Child-Pugh score pretreatment, on the final day of PBT, and 6, 12, and 24 months after treatment with PBT. Patients who had disease progression or who died with tumor progression at each evaluation point were excluded from the analysis to rule out an effect of tumor progression. An increase in the Child-Pugh score of 1 or more was defined as an adverse event. Results: Of the 259 patients, 241 had no disease progression on the final day of PBT, and 91 had no progression within 12 months after PBT. In univariate analysis, the percentage volumes of normal liver receiving at least 0, 10, 20, and 30 GyE in PBT (V0, 10, 20, and 30) were significantly associated with an increase of Child-Pugh score at 12 months after PBT. Of the 91 patients evaluated at 12 months, 66 had no increase of Child-Pugh score, 15 had a 1-point increase, and 10 had an increase of {>=}2 points. For the Youden index, the optimal cut-offs for V0, V10, V20, and V30 were 30%, 20%, 26%, and 18%, respectively. Conclusion: Our findings indicate that liver function after PBT is significantly related to the percentage volume of normal liver that is not irradiated. This suggests that further study of the relationship between liver function and PBT is required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Esophageal Tumor Motion on Cine-Magnetic Resonance Imaging

Purpose: To quantify the movement of esophageal tumors noninvasively on cine-magnetic resonance imaging (MRI) by use of a semiautomatic method to visualize tumor movement directly throughout multiple breathing cycles. Methods and Materials: Thirty-six patients with esophageal tumors underwent MRI. Tumors were located in the upper (8), middle (7), and lower (21) esophagus. Cine-MR images were collected in the coronal and sagittal plane during 60 seconds at a rate of 2 Hz. An adaptive correlation filter was used to automatically track a previously marked reference point. Tumor movement was measured in the craniocaudal (CC), left–right (LR), and anteroposterior (AP) directions and its relationship along the longitudinal axis of the esophagus was investigated. Results: Tumor registration within the individual images was typically done at a millisecond time scale. The mean (SD) peak-to-peak displacements in the CC, AP, and LR directions were 13.3 (5.2) mm, 4.9 (2.5) mm, and 2.7 (1.2) mm, respectively. The bandwidth to cover 95% of excursions from the mean position (c95) was also calculated to exclude outliers caused by sporadic movements. The mean (SD) c95 values were 10.1 (3.8) mm, 3.7 (1.9) mm, and 2.0 (0.9) mm in the CC, AP, and LR dimensions. The end-exhale phase provided a stable position in the respiratory cycle, compared with more variety in the end-inhale phase. Furthermore, lower tumors showed more movement than did higher tumors in the CC and AP directions. Conclusions: Intrafraction tumor movement was highly variable between patients. Tumor position proved the most stable during the respiratory cycle in the end-exhale phase. A better understanding of tumor motion makes it possible to individualize radiation delivery strategies accordingly. Cine-MRI is a successful noninvasive modality to analyze motion for this purpose in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Dependent Cortical Thinning After Partial Brain Irradiation in High-Grade Glioma

Purpose: Radiation-induced cognitive deficits may be mediated by tissue damage to cortical regions. Volumetric changes in cortex can be reliably measured using high-resolution magnetic resonance imaging (MRI). We used these methods to study the association between radiation therapy (RT) dose and change in cortical thickness in high-grade glioma (HGG) patients. Methods and Materials: We performed a voxel-wise analysis of MRI from 15 HGG patients who underwent fractionated partial brain RT. Three-dimensional MRI was acquired pre- and 1 year post RT. Cortex was parceled with well-validated segmentation software. Surgical cavities were censored. Each cortical voxel was assigned a change in cortical thickness between time points, RT dose value, and neuroanatomic label by lobe. Effects of dose, neuroanatomic location, age, and chemotherapy on cortical thickness were tested using linear mixed effects (LME) modeling. Results: Cortical atrophy was seen after 1 year post RT with greater effects at higher doses. Estimates from LME modeling showed that cortical thickness decreased by −0.0033 mm (P<.001) for every 1-Gy increase in RT dose. Temporal and limbic cortex exhibited the largest changes in cortical thickness per Gy compared to that in other regions (P<.001). Age and chemotherapy were not significantly associated with change in cortical thickness. Conclusions: We found dose-dependent thinning of the cerebral cortex, with varying neuroanatomical regional sensitivity, 1 year after fractionated partial brain RT. The magnitude of thinning parallels 1-year atrophy rates seen in neurodegenerative diseases and may contribute to cognitive decline following high-dose RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microwave-assisted hydrothermal synthesis of porous SnO{sub 2} nanotubes and their lithium ion storage properties

Porous SnO{sub 2} nanotubes have been synthesized by a rapid microwave-assisted hydrothermal process followed by annealing in air. The detailed morphological and structural studies indicate that the SnO{sub 2} tubes typically have diameters from 200 to 400 nm, lengths from 0.5 to 1.5 {mu}m and wall thicknesses from 50 to 100 nm. The SnO{sub 2} nanotubes are self-assembled by interconnected nanocrystals with sizes {approx}8 nm resulting in a specific surface area of {approx}54 m{sup 2} g{sup -1}. The pristine SnO{sub 2} nanotubes are used to fabricate lithium half cells to evaluate their lithium ion storage properties. The porous SnO{sub 2} nanotubes are characteristic with high lithium ion storage capacity, that is found to be 1258, 951, 757, 603, 458, and 288 mAh g{sup -1}, at 0.1, 0.2, 0.5, 1, 2, and 4C, respectively. The enhanced electrochemical properties of the SnO{sub 2} nanotubes can be ascribed to their unique geometry and porous structures. - Graphical abstract: Porous SnO{sub 2} nanotubes are synthesized by a fast microwave-assisted hydrothermal process and exhibit high lithium ion storage properties due to their unique geometry and porous characteristics. Highlights: Black-Right-Pointing-Pointer A microwave-assisted hydrothermal method was used to prepare porous SnO{sub 2} nanotubes. Black-Right-Pointing-Pointer The porous SnO{sub 2} nanotubes have abundant mesopores on their tube walls. Black-Right-Pointing-Pointer The porous SnO{sub 2} nanotubes possess high lithium ion storage properties. Black-Right-Pointing-Pointer Our results may promote the development of high-performance anode materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design, manufacture, and evaluation of an anthropomorphic pelvic phantom purpose-built for radiotherapy dosimetric intercomparison

Purpose: An anthropomorphic pelvic phantom was designed and constructed to meet specific criteria for multicenter radiotherapy dosimetric intercomparison. Methods: Three dimensional external and organ outlines were generated from a computed tomography image set of a male pelvis, forming the basis of design for an anatomically realistic phantom. Clinically relevant points of interest were selected throughout the dataset where point-dose values could be measured with thermoluminescence dosimeters and a small-volume ionization chamber. Following testing, three materials were selected and the phantom was manufactured using modern prototyping techniques into five separate coronal slices. Time lines and resource requirements for the phantom design and manufacture were recorded. The ability of the phantom to mimic the entire treatment chain was tested. Results: The phantom CT images indicated that organ densities and geometries were comparable to those of the original patient. The phantom proved simple to load for dosimetry and rapid to assemble. Due to heat release during manufacture, small air gaps and density heterogeneities were present throughout the phantom. The overall cost for production of the prototype phantom was comparable to other commercial anthropomorphic phantoms. The phantom was shown to be suitable for use as a ''patient'' to mimic the entire treatment chain for typical external beam radiotherapy for prostate and rectal cancer. Conclusions: The phantom constructed for the present study incorporates all characteristics necessary for accurate Level III intercomparison studies. Following use in an extensive Level III dosimetric comparison over a large time scale and geographic area, the phantom retained mechanical stability and did not show signs of radiation-induced degradation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗