Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Occupancy-Driven Stochastic Decision Framework for Ranking Commercial Building Loads

For effective integration of building operations into the evolving demand response programs of the power grid, real-time decisions concerning the use of building appliances for grid services must excel on multiple criteria, ranging from the added value to occupants' comfort to the quality of the grid services. In this paper, we present a data-driven stochastic decision-support framework to dynamically rank load control alternatives in a commercial building, addressing the needs of multiple decision criteria (e.g. occupant comfort, grid service quality) under uncertainties in occupancy patterns. We adopt a stochastic multi-criteria decision algorithm recently applied to prioritize residential on/off loads, and extend it to i) consider complex load control decisions (e.g. dimming of lights, changing zone temperature set-points) in a commercial building; and ii) systematically integrate zonal occupancy patterns to better identify short-term (and time-varying) opportunities for grid service participation. We evaluate the performance of the proposed framework for curtailment of air-conditioning, lighting, and plug-loads in a multi-zone commercial office building for a range of design choices. With the help of a prototype system that integrates an interactive \textit{Data Analytics and Visualization} frontend we demonstrate a way for the building operators to monitor and change in real-time the available flexibility in energy consumption and to develop trust in the decision recommendations by interpreting the rationale behind the ranking.

Jain, Milan↗

Multispectral impedance determination under dynamic load conditions

Impedance testing devices, circuits, systems, and related methods are disclosed. A Device Under Test (DUT) is excited with a multispectral excitation signal for an excitation time period while the DUT is under a load condition from a load operably coupled to the DUT. A response of the DUT is sampled over a sample time period. The sample time period is configured such that it includes an in-band interval during the excitation time period and one or more out-of-band intervals outside of the in-band interval. A response of the DUT to the load condition during the in-band interval is estimated by analyzing samples of the response from the one or more out-of-band intervals. Adjusted samples are computed by subtracting the estimated load response during the in-band interval from the samples from the in-band interval. An impedance of the DUT is estimated by analyzing the adjusted samples.

Christophersen, Jon P.↗

Solving Unit Commitment Problems with Demand Responsive Loads: Preprint

This paper focuses on using variations of the Frank-Wolfe algorithm for solving unit commitment problems with high volumes of demand responsive loads on the power grid. We present a formulation of the unit commitment problem with demand responsive loads. We then show through reformulation and relaxations of the problem that variations of the Frank-Wolfe algorithm can be used to determine the time series decisions for the demand responsive loads. We show through computational experiments on the RTS-GMLC test system that the time series of demand responsive load decisions obtained through our approach are near optimal and provide details regarding how large scale parallel implementations of our approach can be highly computationally efficient.

demand response↗

Coordinated net-load management

A management device includes at least one processor communicatively coupled to at least one energy resource controller controlling at least one energy resource and to at least one deferrable load controller controlling power to at least one deferrable load. The is configured to receive an indication, determined based on a frequency value of an electrical network and a nominal frequency value, that a frequency anomaly event has occurred. Responsive to receiving the indication that the frequency anomaly event has occurred, the processor is also configured to determine, for at least one of the energy resource and the deferrable load, based on the frequency value, the nominal frequency value, and a power value of the electrical network, a respective power command, and cause at least one of the at least one energy resource and the at least one deferrable load to modify operation based on the respective power command.

Lundstrom, Blake Richard↗

Distributed Energy Resource-Cognizant Upgrade Paths to the Traditional Restoration Strategy of Utilities for Improved Load Restoration: Preprint

Climate change has resulted in increasingly impactful and more frequent occurrences of extreme weather events. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks under fault scenarios; however, currently, utilities deploying the automated fault location, isolation and restoration (FLISR) function in their advanced distribution management system (ADMS) do not take into account the available generation and load-modification capabilities of distributed energy resources present in the disconnected network due to an upstream isolated fault. This results in the network reconfiguration and restoration to result in sub-optimal load restoration. Therefore, this paper presents two approaches that can upgrade the existing FLISR capabilities of distribution utilities to significantly increase the restoration of critical loads. The performance of the proposed approaches is evaluated on a numerical model of a real distribution feeder in Georgia, USA.

DER↗

Probabilistic evaluation of initiation time in RC bridge beams with load-induced cracks exposed to de-icing salts

In this study, a reliability-based method for predicting the initiation time of reinforced concrete bridge beams with load-induced cracks exposed to de-icing salts is presented. A practical model for predicting the diffusion coefficient of chloride ingress into load-induced cracked concrete is proposed. Probabilistic information about uncertainties related to the surface chloride content and the threshold chloride concentration has been estimated from a wide review of previous experimental or statistical studies. Probabilistic analysis to estimate the time to corrosion initiation with/without considering the effect of the load-induced cracks on the chloride ingress into concrete has been carried out. Results of the analysis demonstrate the importance of considering the effect of the load-induced cracks for correct prediction of corrosion initiation in RC bridge beams exposed to chlorides.

36 MATERIALS SCIENCE↗

Forming Complex Nuclear Fuel Shapes in High-Loaded Silicide Surrogates

This work provides proof of the concept that high silicide loading nuclear fuel meat surrogates with complicated geometries can be produced with uniform density through an application of cold isostatic pressing (CIP). Dispersion fuels with high volumetric loading of U_3 Si_2 have challenges in fabrication. Fabrication involves a series of processes including powder compaction, rolling pack assembly, and roll forming. PNNL has undertaken extensive experimental work using MoSi2 and WSi2 as surrogates for U3Si2 to explore the feasibility of reducing or eliminating the issues through the application of CIP in the powder pressing step prior to rolling pack assembly. The composites were prepared at >40 vol% silicide loading, which was representative of 4.8 gU/cm^3 and formed via CIP at 50 KSI (Kilopound per Square Inch) pressure. The CIP mold design was taken through a design process which aimed to reduce defects and increase precision. The application of CIP here provides a broad strategy for producing highly loaded dispersion fuels with complex geometries and uniform density.

Clelland, Dustin T.↗

Efficiency and Loading Evaluation of High Efficiency Mist Eliminators (HEME) - 12003

High efficiency mist eliminators (HEME) are filters primarily used to remove moisture and/or liquid aerosols from an air stream. HEME elements are designed to reduce aerosol and particulate load on primary High Efficiency Particulate Air (HEPA) filters and to have a liquid particle removal efficiency of approximately 99.5% for aerosols down to sub-micron size particulates. The investigation presented here evaluates the loading capacity of the element in the absence of a water spray cleaning system. The theory is that without the cleaning system, the HEME element will suffer rapid buildup of solid aerosols, greatly reducing the particle loading capacity. Evaluation consists of challenging the element with a waste surrogate dry aerosol and di-octyl phthalate (DOP) at varying intervals of differential pressure to examine the filtering efficiency of three different element designs at three different media velocities. Also, the elements are challenged with a liquid waste surrogate using Laskin nozzles and large dispersion nozzles. These tests allow the loading capacity of the unit to be determined and the effectiveness of washing down the interior of the elements to be evaluated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uranium-Loaded Water Treatment Resins: 'Equivalent Feed' at NRC and Agreement State-Licensed Uranium Recovery Facilities - 12094

Community Water Systems (CWSs) are required to remove uranium from drinking water to meet EPA standards. Similarly, mining operations are required to remove uranium from their dewatering discharges to meet permitted surface water discharge limits. Ion exchange (IX) is the primary treatment strategy used by these operations, which loads uranium onto resin beads. Presently, uranium-loaded resin from CWSs and mining operations can be disposed as a waste product or processed by NRC- or Agreement State-licensed uranium recovery facilities if that licensed facility has applied for and received permission to process 'alternate feed'. The disposal of uranium-loaded resin is costly and the cost to amend a uranium recovery license to accept alternate feed can be a strong disincentive to commercial uranium recovery facilities. In response to this issue, the NRC issued a Regulatory Issue Summary (RIS) to clarify the agency's policy that uranium-loaded resin from CWSs and mining operations can be processed by NRC- or Agreement State-licensed uranium recovery facilities without the need for an alternate feed license amendment when these resins are essentially the same, chemically and physically, to resins that licensed uranium recovery facilities currently use (i.e., equivalent feed). NRC staff is clarifying its current alternate feed policy to declare IX resins as equivalent feed. This clarification is necessary to alleviate a regulatory and financial burden on facilities that filter uranium using IX resin, such as CWSs and mine dewatering operations. Disposing of those resins in a licensed facility could be 40 to 50 percent of the total operations and maintenance (O and M) cost for a CWS. Allowing uranium recovery facilities to treat these resins without requiring a license amendment lowers O and M costs and captures a valuable natural resource. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Evaluation of Loading DOE Standard Canisters in the INL CPP-603 Irradiated Fuel Storage Facility - 20543

This paper looks at the equipment and operations necessary to load United States Department of Energy (DOE)-owned Spent Nuclear Fuel (SNF) into DOE Standard Canisters in the CPP-603 Irradiated Fuel Storage Facility (IFSF) in the Idaho Nuclear Technology and Engineering Center (INTEC) area at Idaho National Laboratory (INL). Two types of fuels are looked at in this evaluation: Advanced Test Reactor (ATR) fuel (uranium-aluminide fuel with aluminum cladding) and Peach Bottom fuel (thorium-uranium carbide fuel in a graphite matrix). The fuel ready for loading would come from fuel storage canisters in the CPP-603 facility. The paper describes the facility, the fuel types, the DOE Standard Canisters, and existing equipment; lists the needed loading operations; reviews facility features and equipment to perform the operations; and then lists the decisions, analyses, designs, demonstrations, and modifications that will be needed to perform the loading of DOE-owned SNF into DOE Standard Canisters in the CPP-603 IFSF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Base-load high-temperature reactors with variable electricity to the grid using Brayton cycles to match low-carbon electricity markets - 18622

The electricity markets are changing because of (1) the transition to a low-carbon electricity grid and (2) addition of solar and wind. The large-scale addition of wind or solar results in low-electricity prices at times of high wind or solar output. It also results in higher electricity prices at times of low wind and solar input. This changing market in the United States favors natural gas plants with low capital costs and high operating costs where it is economic to shut down the gas turbine at times of low electricity prices. Such markets are less favorable to base-load nuclear plants. The change in the markets requires rethinking high-temperature reactor (HTR) power systems to enable base-load reactor operations with variable electricity to the grid. Base-load reactor operation is required to minimize costs but electricity output to the grid must be maximized at times of high prices to maximize total revenue. This can be accomplished by HTR open or closed Brayton power cycles coupled to high-temperature heat storage systems such as Firebrick Resistance-Heated Energy Storage (FIRES) or using auxiliary natural gas if coupled to an open Brayton power cycle. The temperature limits of HTRs are far below gas turbine temperature limits. This characteristic allows the power cycle to operate at base-load on nuclear heat with the option of added peak power by increasing compressed gas temperatures after nuclear heating but before the power turbine with other heat sources (natural gas, FIRES). For the case we have studied, the incremental heat to electricity efficiency is above 66%. The high efficiency is because it is a thermodynamic topping cycle. Because incremental heat-to-electricity efficiency is greater than a stand-alone natural gas plant (60%), such plants can directly compete against natural gas. At times of low electricity prices, electricity from the HTR and purchased from the grid is used to charge FIRES that can provide high-temperature heat as a substitute for natural gas for peak electricity production. Such nuclear Brayton cycles can replace fossil fuels in providing variable electricity on demand to the grid. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Comparison of As-loaded Dose Calculations to Measured Dose Rates

Demonstrating that the radiation dose fields surrounding spent nuclear fuel (SNF) storage and transportation systems meet the applicable limits set forth in 10 CFR 72 for storage and 10 CFR 71 for transportation is essential for the safe handling of radioactive material. The Used Nuclear Fuel-Storage, Transportation, and Disposal Analysis Resource and Data System (UNF-ST&DARDS) [2] is used to provide realistic estimates of SNF-related safety margins. The UNF-ST&DARDS dose rate analysis approach differs from that used in typical licensing approaches, which use design-basis assemblies with bounding source term characteristics to demonstrate the packaging design complies with the regulations. These bounding licensing approaches can increase the time needed to qualify fuel for loading into dry storage and the time a loaded system must wait prior to transportation. UNF-ST&DARDS dose rate assessments allow quantification of realistic, uncredited safety margins associated with actual fuel loading compared with the regulatory limits. While realistic estimation of the dose field surrounding SNF systems may allow for additional flexibility in operations, it is essential to understand how these predictions compare to measured doses. The U.S. Department of Energy Office of Integrated Waste Management and the Prairie Island Indian Community conducted a transportation dose assessment to estimate the site-specific incident-free radiation doses from shipping SNF by rail from the Prairie Island Nuclear Generating Plant (PINGP) through the Prairie Island Indian Community Reservation and Trust Land [5,6]. For that effort, the dose rates were obtained for 50 TN-40 and TN-40HT systems in storage configurations. This work compares the predicted dose rates from UNF-ST&DARDS as-loaded calculations with dose rates measured from 50 SNF storage systems at PINGP. The remainder of this paper discusses the data obtained for the evaluation, the modeling methods, and the results of the calculations.

spent nuclear fuel (SNF), UNF-ST&DARDS, Validation↗

Off-Design Load Analysis of sCO2 Bottoming Cycle for a Natural Gas Combined Cycle Power Plant with Carbon Capture

This work starts with the optimal design from Pidaparti et. al (2024) to analyze the off-design performance of the power plant from 100% down to 50% load. The main operational findings and plant-efficiency for off-load conditions while maintaining the target CO2 capture rate are presented. The goal of the work is to determine if there is a relative advantage or disadvantage for the sCO2 bottoming cycle compared to the steam bottoming cycle in terms of reduced load efficiency performance for the NGCC with carbon capture. Results show nearly identical efficiency profiles for the two cases from 100% to 50% load.

Chinen, Anderson Soares↗

Agrivoltaic Racking Design Optimization Based on Wind and Snow Loading Finite Element Analysis

The racking structure of photovoltaic (PV) systems plays a critical role in ensuring the PV panels generate power properly as it provides integral structural support and sometimes even solar tracking ability. Distinct applications of PV systems require variations of racking structure designs, which yield different mechanical performances under external loading conditions from the environment, such as heavy wind and snow. Past works, such as Reddy et al. [1], have analyzed the pressure effects of wind and snow loading on the racking structure of conventional rooftop and utility PV systems, but there is little knowledge of how various agrivoltaic racking systems perform, in terms of stress and strain, under the same loading conditions. There is also a knowledge gap in the industry on a set of optimized agrivoltaic racking design standards. This study investigates the mechanical performance of various existing racking systems and proposes novel designs that are optimized for agrivoltaics applications under wind and snow loading.

Liao, Quanhuan↗

Regression Models for Demand Reduction based on Cluster Analysis of Load Profiles

This paper provides new regression models for demand reduction of Demand Response programs for the purpose of ex ante evaluation of the programs and screening for recruiting customer enrollment into the programs. The proposed regression models employ load sensitivity to outside air temperature and representative load pattern derived from cluster analysis of customer baseline load as explanatory variables. The proposed models examined their performances from the viewpoint of validity of explanatory variables and fitness of regressions, using actual load profile data of Pacific Gas and Electric Company's commercial and industrial customers who participated in the 2008 Critical Peak Pricing program including Manual and Automated Demand Response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Increasing runoff and sediment load from the Greenland ice sheet at kangerlussuaq (Sonder Stromfjord) in a 30-year perspective, 1979-2008

This observation and modeling study provides insights into runoff and sediment load exiting the Watson River drainage basin, Kangerlussuaq, West Greenland during a 30 year period (1978/79-2007/08) when the climate experienced increasing temperatures and precipitation. The 30-year simulations quantify the terrestrial freshwater and sediment output from part of the Greenland Ice Sheet (GrIS) and the land between the GrIS and the ocean, in the context of global warming and increasing GrIS surface melt. We used a snow-evolution modeling system (SnowModel) to simulate the winter accumulation and summer ablation processes, including runoff and surface mass balance (SMB), of the Greenland ice sheet. Observed sediment concentrations were related to observed runoff, producing a sediment-load time series. To a large extent, the SMB fluctuations could be explained by changes in net precipitation (precipitation minus evaporation and sublimation), with 8 out of 30 years having negative SMB, mainly because of relatively low annual net precipitation. The overall trend in net precipitation and runoff increased significantly, while 5MB increased insignificantly throughout the simulation period, leading to enhanced precipitation of 0.59 km{sup 3} w.eq. (or 60%), runoff of 0.43 km{sup 3} w.eq (or 54%), and SMB of 0.16 km3 w.eq. (or 86%). Runoff rose on average from 0.80 km{sup 3} w.eq. in 1978/79 to 1.23 km{sup 3} w.eq. in 2007/08. The percentage of catchment oudet runoff explained by runoff from the GrIS decreased on average {approx} 10%, indicating that catchment runoff throughout the simulation period was influenced more by precipitation and snowmelt events, and less by runoff from the GrIS. Average variations in the increasing Kangerlussuaq runoff from 1978/79 through 2007/08 seem to follow the overall variations in satellite-derived GrIS surface melt, where 64% of the variations in simulated runoff were explained by regional melt conditions on the GrIS. Throughout the simulation period, the sediment load varied from a minimum of 0.96 x 10{sup 6} t y{sup -1} in 1991/92 to a maximum of 3.52 x 10{sup 6} t y{sup -1} in 2006/07, showing an average increase of sediment load of 9.42 x 10{sup 5} t (or 72%) throughout the period.

58 GEOSCIENCES↗

Acoustic emission analysis of cyclically loaded superelastic shape memory alloy fiber reinforced mortar beams

Superelastic shape memory alloys (SMAs) are metallic alloys that can recover their nonlinear deformations upon unloading. The use of SMAs in cementitious composites as fibers can enable crack recovery and re-centering capabilities. In this study, the crack recovery characteristics of SMA fiber reinforced mortar specimens subjected to flexural cyclic loading are studied through acoustic emission analysis. SMA fiber reinforced mortar specimens with fiber volume ratios of 0.3%, 0.5% and 1.0% are tested under cyclic flexural loads. Acoustic emissions (AE) signals are captured and analyzed to characterize the crack formation and crack width development at each cycle of loading. In addition, the crack width propagation of the specimens is monitored by Digital Image Correlation measurement system and is used as a basis in AE analyses. Results show that the SMA fiber reinforced mortars exhibit considerable re-centering and crack recovery characteristics at large deformation amplitudes.

36 MATERIALS SCIENCE↗

Properly Evaluating load-following products

The authors briefly survey the jurisdictions where load-following products have been successfully used, examine the characteristics of the load-following products, and explain the shortcomings and inaccurate conclusions of previous analyses. A more thorough analysis reveals that the load-following products fulfill the public policy objectives for which they have been designed and do not adversely impact wholesale electricity markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗