Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Numerical Investigation of Two-Stage Vapor Compression System with Simultaneous Vapor and Liquid Injection

Two-stage vapor compression systems can be advantageous over single-stage systems by providing improved system performance, lower discharge temperature and reduced throttling losses. These systems employ various intermediate configurations, such as liquid injection and vapor injection. This paper presents a configuration for a R1234ze(E) two-stage air-conditioning system using a turbo compressor with two injection ports, one for vapor injection and the second for liquid injection. The liquid injection is used to cool the motor and electronics. A component-based representation and solution approach was used to simulate the two-stage compression system with simultaneous vapor and liquid injection at steady state. The turbo compressor was represented using a customized performance map. The condenser and the evaporator were modeled using finite-volume approach. A parametric study was conducted to assess the impact of the following three variables on the system performance: vapor injection ratio, condenser air flow rate, and discharge pipe pressure drop. The simulation results show that as the vapor injection ratio increased, the system performance undergoes a tradeoff between an enhanced subcooling effect (and thus enhanced unit refrigeration capacity) and a decreased suction mass flow rate. Maximum COP occurs when the vapor injection ratio was 0.1. The results also show that as the condenser air flow rate increased, both the capacity and power consumption (including fan power) increased monotonically, and COP increased first and then decreased. At 75% load, the COP improvement at the optimum flow rate was marginally less than 0.5%. Lastly, higher discharge pipe pressure drop increased the discharge pressure. It showed very small effect on the overall system performance at the condition selected for the current study.

component-based steady-state simulation↗

Demonstration of Pronghorn’s Subchannel Code Modeling of Liquid-Metal Reactors and Validation in Normal Operation Conditions and Blockage Scenarios

Pronghorn-SC is a subchannel code within the Multiphysics Object-Oriented Simulation Environment (MOOSE). Initially designed to simulate flows in water-cooled, square lattice, subchannel assemblies, Pronghorn-SC has been expanded to simulate liquid-metal-cooled flows in triangular lattices, hexagonal subchannel assemblies. For this purpose, the algorithm of Pronghorn-SC was adapted to solve the subchannel equations as they are applicable to a hexagonal wire-wrapped sodium-cooled fast reactor. Cheng–Todreas models for pressure drop and cross-flow models were adopted and a coolant heat conduction term was added. To solve these equations, an improved implicit algorithm was developed robust enough to deal with the numerical issues, associated with low flow and recirculation phenomena. To confirm the prediction capability of Pronghorn-SC, calculations and comparisons with available experimental data of 19- and 37-pin assemblies were performed, as well as other subchannel codes. Finally, a flow blockage modeling feature was added. This capability was validated for both water-cooled square sub-assemblies and sodium-cooled hexagonal sub-assemblies, using experimental data of partially and fully blocked cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Crystal Growth Using MEPHISTO

The shuttle flight experiment "In Situ Monitoring of Crystal Growth Using MEPHISTO" was accomplished during STS-87 as part of the fourth flight of the United States Microgravity Payload (USMP-4), which was flown from November 19 to December 5, 1997. The data returned from that flight are just now beginning to yield quantitative results. This project is an international collaboration: the furnace system known as MEPHISTO was built in France by CNES (French National Space Agency) and CEA (French Atomic Energy Commission); the principal investigator, Prof. Reza Abbaschian, is from the University of Florida at Gainesville; and numerical and analytical modeling support includes collaborators from the University of New South Wales, Australia, the University of Wisconsin at Milwaukee, the National Institute of Standards and Technology, and the NASA Lewis Research Center. MEPHISTO is a French acronym that translates into English as Materials for the Study of Interesting Phenomena of Solidification on Earth and in Orbit. Since this was the fourth flight of the MEPHISTO furnace, the experiment is referred to as MEPHISTO-4. MEPHISTO-4 was a directional solidification experiment that studied the liquid-to-solid transformation of bismuth alloyed with tin. Directional solidification is a freezing technique common to the processing of the electronic materials used in integrated circuits and detectors, such as silicon and germanium. When liquids are frozen on Earth, they must be cooled. The cooling causes stirring because of density variations in the liquid. This stirring, known as natural convection, influences the quality of the resulting solid. During freezing, regions of high and low concentrations of tin are created. This introduces another important phenomenon: diffusion, or the movement by molecular action of matter from regions of high concentration to regions of lower concentration. In MEPHISTO-4, it is tin that diffuses from the high-concentration region in front of the solid-liquid interface to more distant low-concentration regions.

deGroh, Henry C., III↗

Green Propellant Test Capabilities of the Altitude Combustion Stand at the NASA Glenn Research Center

The NASA Glenn Research Center (GRC) is committed to providing simulated altitude rocket test capabilities to NASA programs, other government agencies, private industry partners, and academic partners. A primary facility to support those needs is the Altitude Combustion Stand (ACS). ACS provides the capability to test combustion components at a simulated altitude up to 100,000 ft. (approx.0.2 psia/10 Torr) through a nitrogen-driven ejector system. The facility is equipped with an axial thrust stand, gaseous and cryogenic liquid propellant feed systems, data acquisition system with up to 1000 Hz recording, and automated facility control system. Propellant capabilities include gaseous and liquid hydrogen, gaseous and liquid oxygen, and liquid methane. A water-cooled diffuser, exhaust spray cooling chamber, and multi-stage ejector systems can enable run times up to 180 seconds to 16 minutes. The system can accommodate engines up to 2000-lbf thrust, liquid propellant supply pressures up to 1800 psia, and test at the component level. Engines can also be fired at sea level if needed. The NASA GRC is in the process of modifying ACS capabilities to enable the testing of green propellant (GP) thrusters and components. Green propellants are actively being explored throughout government and industry as a non-toxic replacement to hydrazine monopropellants for applications such as reaction control systems or small spacecraft main propulsion systems. These propellants offer increased performance and cost savings over hydrazine. The modification of ACS is intended to enable testing of a wide range of green propellant engines for research and qualification-like testing applications. Once complete, ACS will have the capability to test green propellant engines up to 880 N in thrust, thermally condition the green propellants, provide test durations up to 60 minutes depending on thrust class, provide high speed control and data acquisition, as well as provide advanced imaging and diagnostics such as infrared (IR) imaging.

Testing↗

Single and Double-Sided Jet Impingement Cooling for SiC-Based Power Modules

Efficient thermal management of power electronics systems is crucial for higher reliability. With the miniaturization of systems, high-loss-density electronics require cooling systems that can extract a large amount of heat. This study explored a liquid-jet-impingement-based direct substrate cooling system for single-sided and double-sided cooling to improve heat extraction efficiency and improve the power density by reducing the volume and mass. The cooling system was implemented for a SiC-based direct bonded copper substrate. Numerical simulations were performed to determine the effects of nozzle diameter, the number of nozzles, and nozzle array orientation on single-sided cooling and thermal performance gain over double-sided cooling. A novel manifold design was proposed that reduced the volume and mass of the manifold and still achieved the target power density. The performance of the proposed design was compared with the pin-fin-based cooling system used in the BMW I3 module, and a comparative analysis was done.

Barua, Himel↗

Helium refrigerator

An improved helium refrigerator of the type which includes a plurality of counter-flow heat exchangers and has a maximum reserve cooling capacity when the final or low-temperature heat exchanger is substantially filled with liquid helium, and a minimum reserve cooling capacity when the low-temperature heat exchanger is substantially filled with gas. An electrical bridge circuit including a pair of temperature responsive resistors is mounted on the low-temperature heat exchanger for providing a continuous indication of the reserve cooling capacity of the refrigerator.

Ervin R Wiebe↗

Phase-Change Heat-Storage Module

Heat-storage module accommodates momentary heating or cooling overload in pumped-liquid heat-transfer system. Large heat-storage capacity of module provided by heat of fusion of material that freezes at or near temperature desired to maintain object to be heated or cooled. Module involves relatively small penalties in weight, cost, and size and more than compensates by enabling design of rest of system to handle only average load. Latent heat of fusion of phase-change material provides large heat-storage capacity in small volume.

Mulligan, James C.↗

Quick Cooling and Filling Through a Single Port for Cryogenic Transfer Operations

Improved technology for the efficient transfer of cryogens is needed for future on-orbit fueling and remote Lunar/Mars operations. The cooling and filling of a liquid nitrogen (LN2) test vessel through a single port were investigated in a series of experiments. A new 'in-space' transfer tube design concept was used to demonstrate the ability to quickly cool and load cryogens through a single feed-through connection. Three different fill tube configurations with three different diameters were tested. The tubes providing the quickest cooldown time and the quickest fill time for the test article tank were determined. The results demonstrated a clear trade-off between cooling time and filling time for the optimum tube design. This experimental study is intended to improve technology for future flight tank designs by reducing fill system size, complexity, heat leak rate, and operations time. These results may be applied to Space Shuttle Power Reactant Storage and Distribution (PRSD) System upgrades and other future applications. Further study and experimental analysis for optimization of the fill tube design are in progress.

Jones, J. R.↗

Performance of a transpiration-regenerative cooled rocket thrust chamber

The analysis, design, fabrication, and testing of a liquid rocket engine thrust chamber which is gas transpiration cooled in the high heat flux convergent portion of the chamber and water jacket cooled (simulated regenerative) in the barrel and divergent sections of the chamber are described. The engine burns LOX-hydrogen propellants at a chamber pressure of 600 psia. Various transpiration coolant flow rates were tested with resultant local hot gas wall temperatures in the 800 F to 1400 F range. The feasibility of transpiration cooling with hydrogen and helium, and the use of photo-etched copper platelets for heat transfer and coolant metering was successfully demonstrated.

Valler, H. W.↗

Direct Numerical Simulation of Fog Formation Within the Surface Layer

We investigate the effects of shear-driven turbulence on fog formation in the stably stratified surface layer, using recent direct numerical simulations (DNS) of dry and moist open-channel flows. A constant cooling rate applied at the ground mimics longwave radiative cooling, leading to either turbulent (weakly stable) or laminar (very stable) flows. The transition of the Obukhov, Ozmidov and buoyancy length scales are investigated for different cooling rates and Reynolds numbers. Compared to the dry case, the condensation of liquid water in the moist case supports slightly higher cooling rates before leading to turbulence collapse. In the very stable moist cases, runaway cooling leads to substantial condensation of liquid water close to the ground and fog (visibility less than 1 km) results over much of the domain. In the weakly stable cases, turbulent mixing narrowly yields visibilities of 1 km close to the ground over a similar time period. Despite the idealised nature of the system, the present results suggest that turbulence impedes, although will not necessarily inhibit, fog formation.

Teixeira, Joao↗

Rapid solidification of highly undercooled alloy droplets

Experimental work is described on undercooling and structure of tin-lead droplets emulsified in oil. The droplets, predominantly in the size range of 10-20 microns, were cooled at rates ranging from about 0.04 K/sec to 1,000,000 K/sec. The higher cooling rates were obtained by a newly developed technique of quenching the emulsified droplets in a cold liquid. Measured undercoolings (at the lower cooling rates) ranged up to about 100 C. Structures obtained depended strongly on undercooling, cooling rate before nucleation, droplet size, alloy composition and the rate of heat extraction after nucleation.

Chu, M. G.↗

Solidification of highly undercooled Sn-Pb alloy droplets

Experimental work on undercooling and structure of tin-lead droplets emulsified in oil is described. The droplets, predominantly in the size range of 10 to 20 microns, were cooled at rates (just before nucleation) ranging from about 0.1 to 1 million K/s. The higher cooling rates were obtained by a newly developed technique of quenching the emulsified droplets in a cold liquid. Measured undercoolings (at the lower cooling rates) ranged up to about 100 K. Structures obtained depend strongly on undercooling, cooling rate before and after nucleation, and alloy composition. Droplets containing up to 5 wt pct Pb were apparently single phase when undercooled and rapidly quenched. Droplets in the composition range of about 25-90 wt pct Pb solidified dendritically, even at the most rapid quench rates employed, apparently because these alloys undercooled only slightly before nucleation of the primary phase.

Chu, M. G.↗

Degradation of Poly- and Perfluoroalkyl Substances (PFAS) in Water via High Power, Energy-Efficient Electron Beam Accelerator

The goal of the 2-year workplan was to see if electron beam (EB) could be used to break down a sub-set of the larger chemical family of per and polyfluoroalkylated substances (PFAS) in an energy efficient and economical manner when compared to conventional water treatment technologies. Year one (Y1) work focused on sample EB treatment work in the Fermi National Accelerator Laboratory’s (FNALs) Accelerator Applications Demonstration and Development (A2D2) EB accelerator. While there are reportedly thousands of types of PFAS, for the point of most of the work herein, a small subset was examined, typically perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA). PFOA and PFOS are two of the most well studied PFAS and are studied for baseline evaluations and are considered most useful. The work from Y1 provided information about the optimal operating parameters and additives to use when treating PFOS and PFOA via EB. The data were then used to see where in a water treatment system an EB accelerator would be best suited to treat PFAS. A conventional water treatment technology, GAC, was then compared to e-beam treatment technology with respect to energy and costs for treatment. In year two (Y2), several conventional e-beam accelerator designs, and FNAL’s developmental compact SRF accelerator design, were evaluated for their suitability in PFAS treatment, from an energy efficiency and cost standpoint. Several EB parameters were evaluated and optimized for the removal of PFOA and PFOS from water at normal pressure and temperature, measured as total PFAS removal. Under the optimized test conditions both PFOA showed complete destruction to inorganic fluoride, and PFOS to inorganic fluoride and sulfate, with mass balance. The effect on PFAS removal relative to solution pH, total EB dose, EB dose rate, dissolved oxygen concentration (DO), temperature, and initial PFAS concentration were evaluated. In general, PFOA was easier to destroy than PFOS. Degradation products, typically observed under less-than-optimal EB conditions, provided insight to degradation mechanisms. Products were identified to rule out possible deleterious biproduct formation. The water radiolysis radical reaction kinetics with PFOS and PFOA were not dependent on the initial concentration over 5-orders of magnitude from 2 μg/L to 20 mg/L. This is thought to be because there was an overabundance of the reactive water radiolysis radicals relative to PFAS molecules and largely attributed to aqueous electrons. The reaction rates appeared to be diffusion limited. Testing at higher concentrations (100-200 mg/L) showed a decrease in removal efficiency, suggesting alternative kinetics, possibly second order rates, at higher concentrations. In all, we successfully defined a set of optimal EB parameters to treat PFOA and PFOS at concentrations of 20 mg/L in water with destruction efficiencies near 100%. We further tested the optimized EB parameters with other types of PFAS, including shorter and longer fluorocarbon chain homologs of PFOA and PFOS, and PFAS with alternative functional groups such as sulfonamides. Based on our results EB can be optimized as an effective destructive technology for removing PFAS from water. The conditions optimized for PFOA and PFOS were less effective with ultra-short fluorocarbon compounds like TFMS, PFES, PFPS and PFBS, and likely require re-optimization of parameters to them. In all, it was determined that from a cost and energy efficiency standpoint, EB would be best applied to waste streams with relatively high concentrations of PFOS and PFOA and is not as cost effective as GAC treatment for removing low concentrations of PFAS from water. Higher concentrations of PFAS can be found in the wastewater of conventional treatment processes such as RO and IE and therefore EB may be used to supplement such treatment technologies. Some real-world IE regeneration wash water and RO reject water containing higher concentrations of PFAS and obtained from pilot scale industrial wastewater treatment system at a fluorochemical manufacturing facility, showed that EB could remove PFAS from such types of wastewaters. The IE regenerant wash water appeared to be the most efficient of the two types of wastewaters tested. However, some further optimization of the EB parameters for the specific PFAS types present in those wastewaters may be required. Also, the effects of co-present TOC and mineral salts should be considered during such optimization efforts. From the experimental Y1 results it was seen that the aqueous electron drives degradation of the PFAS. In a hypothetical water treatment skid using EB for PFAS destruction the parameters of the system should be optimized to promote aqueous electron production. Before EB treatment, the PFAS should be preconcentrated when possible, the pH should be raised to pH 10 or higher to enhance aqueous electron production, and the water should be nitrogen purged to remove dissolved oxygen to minimize aqueous electron scavenging. An excel spreadsheet was created that calculates optimal conditions based on inlet PFAS concentration and desired outlet concentration, by optimizing the accelerator power, dose rate, water treatment rate, pH and dissolved oxygen levels to reach the desired endpoint. Given this information on accelerator operating conditions five different EB accelerator systems were compared. One EB system was a continuous-wave, linear superconducting accelerator being designed at Fermilab. Three other EB systems (IMPELA at 5% and 25% duty factor and the ILU-14) were normal conducting pulsed linear accelerators. The fifth system was an IBA Rhodotron which is a normal conducting, circular, continuous-wave accelerator. The accelerator efficiency (% of the incoming power that is used in water treatment) was the dominating factor in accelerator choice. The radio frequency (RF) power supply and the accelerator design (superconducting versus warm technology) drive the accelerator efficiency. The IBA Rhodotron was seen to be the most energy efficient commercially available technology with a wall-plug (total) power efficiency of 43% at 400 kW. The Fermilab design, with a prototype for a different application currently being fabricated, was the most energy efficient at 55% when driven by a Klystron RF power supply and as high as 77% when powered by a magnetron. As the Fermilab design was the most energy efficient by approximately 10-30%, further design work was done on the accelerator and beam delivery system specific to the destruction of PFAS in water. The Fermilab design is unique from industrial accelerators in that is superconducting. Superconducting technology allows for the acceleration of electrons without losses. The accelerator must be cooled to below the point where it is superconducting and is operated around 4 degrees Kelvin. The bulk of the design work for the accelerator is on making the accelerator as energy efficient as possible so that it does not require liquid helium and can be cooled with conduction cooling via cryocoolers. Final design work resulted in an EB accelerator that would operate at minimally 200 kW and 10 MeV. Prototype construction would cost $\$ $7.8 million dollars when driven by a Klystron power supply. A second version of the same accelerator would cost $\$ $5.5 million dollars when driven by a magnetron that is still under development. The commercially available 300 kW IBA Rhodotron cost was estimated at approximately $\$ $9 million. While it is hard to directly compare, an operational GAC system used by 3M for groundwater treatment capital cost (2022 dollars) was estimated to cost $\$ $3.3 million. While the capital expense of the EB accelerator systems was higher than GAC, the accelerator EB treatment would result in destruction of the PFAS and not just sequestration of PFAS to form a new waste stream that requires further treatment or disposal. The operating cost to destroy the PFAS via 400 kw EB system was less than $\$ $1000/kg of PFAS destroyed when treating at a 20 mg/L PFAS concentration, compared to GAC with operating costs that calculated at $\$ $27,530 per kg of PFAS sequestered when treating 100 μg/L PFOA and PFOS combined concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved Traps for Removing Gases From Coolant Liquids

Two documents discuss improvements in traps for removing noncondensable gases (e.g., air) from heat-transfer liquids (e.g., water) in spacecraft cooling systems. Noncondensable gases must be removed because they can interfere with operation. A typical trap includes a cylindrical hydrophobic membrane inside a cylindrical hydrophilic membrane, all surrounded by an outer cylindrical impermeable shell. The input mixture of gas bubbles and liquid flows into the annular volume between the membranes. Bubbles pass into the central hollow of the hydrophobic membrane and are vented. The liquid flows outward through the hydrophilic membrane and is recirculated.

Holladay, John↗

Switchable system for high-salinity brine desalination and fractional precipitation

A saline feed stream flows into a liquid-liquid extraction system; and a volatile organic solvent flows through a main compressor. The compressed volatile organic solvent then flows through a solvent regenerator, which can be a heat exchanger or a combination of a vaporization device and a condenser, to cool the volatile organic solvent. The cooled volatile organic solvent in liquid phase then flows into the liquid-liquid extraction system, where the saline feed stream contacts the volatile organic solvent to selectively extract water from the saline feed stream into the volatile organic solvent, producing a concentrated brine and an organic-rich mixture of water and the volatile organic solvent. The organic-rich mixture flows from the liquid-liquid extraction system into the solvent regenerator, where the organic-rich mixture is heated to produce an organic-rich vapor and desalinated water; and the organic-rich vapor is recycled as volatile organic solvent back into the liquid-liquid extraction system.

Wilson, Aaron D.↗

A Thermal Physiological Comparison of Two HazMat Protective Ensembles With and Without Active Convective Cooling

Wearing impermeable garments for hazardous materials clean up can often present a health and safety problem for the wearer. Even short duration clean up activities can produce heat stress injuries in hazardous materials workers. It was hypothesized that an internal cooling system might increase worker productivity and decrease likelihood of heat stress injuries in typical HazMat operations. Two HazMat protective ensembles were compared during treadmill exercise. The different ensembles were created using two different suits: a Trelleborg VPS suit representative of current HazMat suits and a prototype suit developed by NASA engineers. The two life support systems used were a current technology Interspiro Spirolite breathing apparatus and a liquid air breathing system that also provided convective cooling. Twelve local members of a HazMat team served as test subjects. They were fully instrumented to allow a complete physiological comparison of their thermal responses to the different ensembles. Results showed that cooling from the liquid air system significantly decreased thermal stress. The results of the subjective evaluations of new design features in the prototype suit were also highly favorable. Incorporation of these new design features could lead to significant operational advantages in the future.

Williamson, Rebecca↗

Order-disorder in room-temperature ionic liquids probed via methyl quantum tunneling

Room-temperature ionic liquids are promising candidates for applications ranging from electrolytes for energy storage devices to lubricants for food and cellulose processing to compounds for pharmaceutics, biotransformation, and biopreservation. Due to the ion complexity, many room-temperature ionic liquids readily form amorphous phases upon cooling, even at modest rates. Here, we investigate two commonly studied imidazolium-based room-temperature ionic liquids, 1-ethyl-3-methylimidazolium tetrafluoroborate and 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, as well as their mixtures, to demonstrate how the complex interplay between the crystalline and amorphous phases is affected by the processing conditions, such as thermal history, liquid mixing, and applied pressure. We show that quantum tunneling in the cation methyl groups, measured by high-resolution inelastic neutron scattering, can be used to probe the order-disorder in room-temperature ionic liquids (crystalline vs amorphous state) that develops as a result of variable processing conditions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗