Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

A new MAP for Mars

A Mars Aerial Platform (MAP) mission capable of generating thousands of very-high-resolution (20 cm/pixel) pictures of the Martian surface is considered. The MAP entry vehicle will map the global circulation of the planet's atmosphere and examine the surface and subsurface. Data acquisition will use instruments carried aboard balloons flying at nominal altitude of about 7 km over the Martian surface. The MAP balloons will take high- and medium-resolution photographs of Mars, sound its surface with radar, and provide tracking data to chart its winds. Mars vehicle design is based on the fourth-generation NTP, NEP, SEP vehicle set that provides a solid database for determining transportation system costs. Interference analysis and 3D image generation are performed using manual system sizing and sketching in conjunction with precise CAD modeling.

Zubrin, Robert↗

Reduction and Analysis of Phosphor Thermography Data With the IHEAT Software Package

Detailed aeroheating information is critical to the successful design of a thermal protection system (TPS) for an aerospace vehicle. This report describes NASA Langley Research Center's (LaRC) two-color relative-intensity phosphor thermography method and the IHEAT software package which is used for the efficient data reduction and analysis of the phosphor image data. Development of theory is provided for a new weighted two-color relative-intensity fluorescence theory for quantitatively determining surface temperatures on hypersonic wind tunnel models; an improved application of the one-dimensional conduction theory for use in determining global heating mappings; and extrapolation of wind tunnel data to flight surface temperatures. The phosphor methodology at LaRC is presented including descriptions of phosphor model fabrication, test facilities and phosphor video acquisition systems. A discussion of the calibration procedures, data reduction and data analysis is given. Estimates of the total uncertainties (with a 95% confidence level) associated with the phosphor technique are shown to be approximately 8 to 10 percent in the Langley's 31-Inch Mach 10 Tunnel and 7 to 10 percent in the 20-Inch Mach 6 Tunnel. A comparison with thin-film measurements using two-inch radius hemispheres shows the phosphor data to be within 7 percent of thin-film measurements and to agree even better with predictions via a LATCH computational fluid dynamics solution (CFD). Good agreement between phosphor data and LAURA CFD computations on the forebody of a vertical takeoff/vertical lander configuration at four angles of attack is also shown. In addition, a comparison is given between Mach 6 phosphor data and laminar and turbulent solutions generated using the LAURA, GASP and LATCH CFD codes. Finally, the extrapolation method developed in this report is applied to the X-34 configuration with good agreement between the phosphor extrapolation and LAURA flight surface temperature predictions. The phosphor process outlined in the paper is believed to provide the aerothermodynamic community with a valuable capability for rapidly obtaining (4 to 5 weeks) detailed heating information needed in TPS design.

Merski, N. Ronald↗

The OVIRS Visible/IR Spectrometer on the OSIRIS-Rex Mission

The OSIRIS-REx (Origins Spectral Interpretation Resource Identification Security Regolith Explorer) Mission is a planetary science mission to study, and return a sample from, the carbonaceous asteroid 1999 RQ-36. The third mission selected under NASA's New Frontiers Program, it is scheduled to be launched in 2016. It is led by PI Dante Lauretta at the University of Arizona and managed by NASA's Goddard Space Flight Center. The spacecraft and the asteroid sampling mechanism, TAGSAM (Touch-And-Go Sample Acquisition Mechanism) will be provided by Lockheed Martin Space Systems. Instrumentation for studying the asteroid include: OCAMS (the OSIRIS-REx Camera Suite), OLA (the OSIRIS-REx Laser Altimeter, a scanning LIDAR), OTES (The OSIRIS-REx Thermal Emission Spectrometer, a 4-50 micron point spectrometer) and OVIRS (the OSIRIS-REx Visible and IR Spectrometer, a 0.4 to 4.3 micron point spectrometer). The payload also includes REXIS (the Regolith X-ray Imaging Spectrometer) a student provided experiment. This paper presents a description of the OVIRS instrument.

Reuter, D. C.↗

Imaging IR spectrometer, phase 2

The development is examined of a prototype multi-channel infrared imaging spectrometer. The design, construction and preliminary performance is described. This instrument is intended for use with JPL Table Mountain telescope as well as the 88 inch UH telescope on Mauna Kea. The instrument is capable of sampling simultaneously the spectral region of 0.9 to 2.6 um at an average spectral resolution of 1 percent using a cooled (77 K) optical bench, a concave holographic grating and a special order sorting filter to allow the acquisition of the full spectral range on a 128 x 128 HgCdTe infrared detector array. The field of view of the spectrometer is 0.5 arcsec/pixel in mapping mode and designed to be 5 arcsec/pixel in spot mode. The innovative optical design has resulted in a small, transportable spectrometer, capable of remote operation. Commercial applications of this spectrometer design include remote sensing from both space and aircraft platforms as well as groundbased astronomical observations.

Gradie, Jonathan↗

Comprehensive single-shot biophysical cytometry using simultaneous quantitative phase imaging and Brillouin spectroscopy

Abstract Single-cell analysis, or cytometry, is a ubiquitous tool in the biomedical sciences. Whereas most cytometers use fluorescent probes to ascertain the presence or absence of targeted molecules, biophysical parameters such as the cell density, refractive index, and viscosity are difficult to obtain. In this work, we combine two complementary techniques—quantitative phase imaging and Brillouin spectroscopy—into a label-free image cytometry platform capable of measuring more than a dozen biophysical properties of individual cells simultaneously. Using a geometric simplification linked to freshly plated cells, we can acquire the cellular diameter, volume, refractive index, mass density, non-aqueous mass, fluid volume, dry volume, the fractional water content of cells, both by mass and by volume, the Brillouin shift, Brillouin linewidth, longitudinal modulus, longitudinal viscosity, the loss modulus, and the loss tangent, all from a single acquisition, and with no assumptions of underlying parameters. Our methods are validated across three cell populations, including a control population of CHO-K1 cells, cells exposed to tubulin-disrupting nocodazole, and cells under hypoosmotic shock. Our system will unlock new avenues of research in biophysics, cell biology, and medicine.

Steelman, Zachary A.↗

Data processing methods and data acquisition for samples larger than the field of view in parallel-beam tomography

Parallel-beam tomography systems at synchrotron facilities have limited field of view (FOV) determined by the available beam size and detector system coverage. Scanning the full size of samples bigger than the FOV requires various data acquisition schemes such as grid scan, 360-degree scan with offset center-of-rotation (COR), helical scan, or combinations of these schemes. Though straightforward to implement, these scanning techniques have not often been used due to the lack of software and methods to process such types of data in an easy and automated fashion. The ease of use and automation is critical at synchrotron facilities where using visual inspection in data processing steps such as image stitching, COR determination, or helical data conversion is impractical due to the large size of datasets. Here, we provide methods and their implementations in a Python package, named Algotom, for not only processing such data types but also with the highest quality possible. The efficiency and ease of use of these tools can help to extend applications of parallel-beam tomography systems.

36 MATERIALS SCIENCE↗

Mars Solar Balloon Landed Gas Chromatograph Mass Spectrometer

A Mars surface lander Gas Chromatograph Mass Spectrometer (GCMS) is described to measure the chemical composition of abundant and trace volatile species and isotope ratios for noble gases and other elements. These measurements are relevant to the study of atmospheric evolution and past climatic conditions. A Micromission plan is under study where a surface package including a miniaturized GCMS would be delivered to the surface by a solar heated hot air balloon based system. The balloon system would be deployed about 8 km above the surface of Mars, wherein it would rapidly fill with Martian atmosphere and be heated quickly by the sun. The combined buoyancy and parachuting effects of the solar balloon result in a surface package impact of about 5 m/sec. After delivery of the package to the surface, the balloon would ascend to about 4 km altitude, with imaging and magnetometry data being taken for the remainder of the daylight hours as the balloon is blown with the Martian winds. Total atmospheric entry mass of this mission is estimated to be approximately 50 kg, and it can fit as an Ariane 5 piggyback payload. The GCMS would obtain samples directly from the atmosphere at the surface and also from gases evolved from solid phase material collected from well below the surface with a Sample Acquisition and Transport Mechanism (SATM). The experiment envisioned in the Mars Micromission described would obtain samples from a much greater depth of up to one meter below the surface, and would search for organic molecules trapped in ancient stratified layers well below the oxidized surface. Insitu instruments on upcoming NASA missions working in concert with remote sensing measurement techniques have the potential to provide a more detailed investigation of mineralogy and the extent of simple volatiles such as CO2 and H2O in surface and subsurface solid phase materials. Within the context of subsequent mission opportunities such as those provided by the Ariane 5 piggyback payload based Micromissions, it is essential to implement an even broader chemical analysis and to enable a significant extension of previous isotope measurements. Such a development would enhance the presently very active study of questions of atmospheric evolution and loss and past climatic conditions. The method selected to implement this program can be based on well-established mass spectrometry techniques. Sampled gas is chemically and physically processed to separate the gas mixture into components using gas chromatograph and related enrichment techniques. This allows trace species to be identified and reveals isotopic distributions in many cases with improved precision. Samples of interest, such as organic molecules, may lie deep below the highly oxidized surface layer and the suggested program includes enhanced sampling techniques to measure volatiles preserved in solid phase material deep below the surface as well as gas from the well mixed atmosphere.

Mahaffy, P.↗

Landsat Science: 40 Years of Innovation and Opportunity

Landsat satellites have provided unparalleled Earth-observing data for nearly 40 years, allowing scientists to describe, monitor and model the global environment during a period of time that has seen dramatic changes in population growth, land use, and climate. The success of the Landsat program can be attributed to well-designed instrument specifications, astute engineering, comprehensive global acquisition and calibration strategies, and innovative scientists who have developed analytical techniques and applications to address a wide range of needs at local to global scales (e.g., crop production, water resource management, human health and environmental quality, urbanization, deforestation and biodiversity). Early Landsat contributions included inventories of natural resources and land cover classification maps, which were initially prepared by a visual interpretation of Landsat imagery. Over time, advances in computer technology facilitated the development of sophisticated image processing algorithms and complex ecosystem modeling, enabling scientists to create accurate, reproducible, and more realistic simulations of biogeochemical processes (e.g., plant production and ecosystem dynamics). Today, the Landsat data archive is freely available for download through the USGS, creating new opportunities for scientists to generate global image datasets, develop new change detection algorithms, and provide products in support of operational programs such as Reducing Emissions from Deforestation and Forest Degradation in Developing Countries (REDD). In particular, the use of dense (approximately annual) time series to characterize both rapid and progressive landscape change has yielded new insights into how the land environment is responding to anthropogenic and natural pressures. The launch of the Landsat Data Continuity Mission (LDCM) satellite in 2012 will continue to propel innovative Landsat science.

Cook, Bruce D.↗

LiDAR-Based Map Relative Localization Performance Analysis for Landing on Europa

This paper presents preliminary simulations andanalyses done to assess the feasibility of performing Map RelativeLocalization (MRL) with the Europa Lander LiDAR beingdeveloped for the Europa Lander Pre-Phase A concept. MapRelative Localization is the process of determining the horizontalposition of a lander with respect to an onboard, a-priori map,by comparing the map to sensor observations of the terrain duringdeorbit, descent, and landing (DDL). Although kilometerscaleposition knowledge is commonly available during DDL,landing in hazard-rich environments requires position errors of100 m or less. Prior knowledge in the case of Europa Landerwill be visual and topographic maps collected by the upcomingEuropa Clipper mission. The Mars 2020 Lander Vision System(LVS) uses images from a camera to localize with respect tovisual maps. This technology, as well as a 3D imaging LiDAR indevelopment for hazard detection, is currently baselined for theEuropa Lander Pre-Phase A concept. This paper investigatesthe potential use of the hazard detection LiDAR to performMRL with respect to a 3D digital elevation model (DEM)provided by the Europa Clipper mission, as an alternative orbackup solution to passive optical MRL. Compared to passiveoptical MRL, one advantage of LiDAR-based localization isthat it is insensitive to lighting conditions, potentially relaxingrequirements on synchronizing map acquisition and landingtime of day. To analyze LiDAR based MRL performance,six representative terrains are synthetically up-sampled fromGalileo-derived maps of Europa to a resolution of 0.5 m/pxand covering an area of 4 km by 4 km. These maps are usedas ground-truth to generate simulated noisy a-priori onboardtopographic maps expected from Europa Clipper as well assimulated LiDAR DEMs generated at an altitude of 5 km duringEuropa Lander DDL. The simulated LiDAR DEM is matchedagainst the simulated map via 2D normalized cross-correlation,exploiting the accurately known spacecraft attitude to avoidthe need for more computationally intensive algorithms such asIterative Closest Point (ICP). Two sources of measurement errorare identified for analysis: 1) additive Gaussian noise in therange measurements from the Europa Lander LiDAR and theEuropa Clipper derived maps and 2) errors in the LiDAR DEMinduced by errors in the Europa Lander state estimate which isused to de-warp the LiDAR scan data into a DEM format. Weassess the effect of each of these types of errors independently onmatching performance as well as the overall performance whenall types of error are introduced. Additionally, we present theresult of a sensitivity study to terrain frequency content.

Trawny, Nikolas↗

Patch2Self2: Self-supervised Denoising on Coresets via Matrix Sketching

Diffusion MRI (dMRI) non-invasively maps brain white matter yet necessitates denoising due to low signal-to-noise ratios. Patch2Self (P2S) employing self-supervised techniques and regression on a Casorati matrix effectively denoises dMRI images and has become the new de-facto standard in this field. P2S however is resource intensive both in terms of running time and memory usage as it uses all voxels (n) from all-but-one held-in volumes (d-1) to learn a linear mapping Phi : \mathbb R ^ n x(d-1) \mapsto \mathbb R ^ n for denoising the held-out volume. The increasing size and dimensionality of higher resolution dMRI acquisitions can make P2S infeasible for large-scale analyses. This work exploits the redundancy imposed by P2S to alleviate its performance issues and inspect regions that influence the noise disproportionately. Specifically this study makes a three-fold contribution: (1) We present Patch2Self2 (P2S2) a method that uses matrix sketching to perform self-supervised denoising. By solving a sub-problem on a smaller sub-space so called coreset we show how P2S2 can yield a significant speedup in training time while using less memory. (2) We present a theoretical analysis of P2S2 focusing on determining the optimal sketch size through rank estimation a key step in achieving a balance between denoising accuracy and computational efficiency. (3) We show how the so-called statistical leverage scores can be used to interpret the denoising of dMRI data a process that was traditionally treated as a black-box. Experimental results on both simulated and real data affirm that P2S2 maintains denoising quality while significantly enhancing speed and memory efficiency achieved by training on a reduced data subset.

Fadnavis, Shreyas↗

Comparison of pyrometry and thermography for thermal analysis of thermite reactions

This article examines the thermal behavior of a laser ignited thermite composed of aluminum and bismuth trioxide. Temperature data were collected during the reaction using a four-color pyrometer and a high-speed color camera modified for thermography. The two diagnostics were arranged to collect data simultaneously, with similar fields of view and with similar data acquisition rates, so that the two techniques could be directly compared. Results show that at initial and final stages of the reaction, a lower signal-to-noise ratio affects the accuracy of the measured temperatures. Both diagnostics captured the same trends in transient thermal behavior, but the average temperatures measured with thermography were about 750 K higher than those from the pyrometer. This difference was attributed to the lower dynamic range of the thermography camera’s image sensor, which was unable to resolve cooler temperatures in the field of view as well as the photomultiplier tube sensors in the pyrometer. Overall, while the camera could not accurately capture the average temperature of a scene, its ability to capture peak temperatures and spatial data make it the preferred method for tracking thermal behavior in thermite reactions.

36 MATERIALS SCIENCE↗

Non-Intrusive, Laser-Based Imaging of Jet-A Fuel Injection and Combustion Species in High Pressure, Subsonic Flows

The emphasis of combustion research efforts at NASA Glenn Research Center (GRC) is on collaborating with industry to design and test gas-turbine combustors and subcomponents for both sub- and supersonic applications. These next-generation aircraft combustors are required to meet strict international environmental restrictions limiting emissions. To meet these goals, innovative combustor concepts require operation at temperatures and pressures far exceeding those of cur-rent designs. New and innovative diagnostic tools are necessary to characterize these flow streams since existing methods are inadequate. The combustion diagnostics team at GRC has implemented a suite of highly sensitive, nonintrusive optical imaging methods to diagnose the flowfields of these new engine concepts. By using optically accessible combustors and flametubes, imaging of fuel and intermediate combustion species via planar laser-induced fluorescence (PLIF) at realistic pressures are now possible. Direct imaging of the fuel injection process through both planar Mie scattering and PLIF methods is also performed. Additionally, a novel combination of planar fuel fluorescence imaging and computational analysis allows a 3-D examination of the flowfield, resulting in spatially and temporally resolved fuel/air volume distribution maps. These maps provide detailed insight into the fuel injection process at actual conditions, thereby greatly enhancing the evaluation of fuel injector performance and other combustion phenomena. Stable species such as CO2, O2, N2O. and hydrocarbons are also investigated by a newly demonstrated 1-D, spontaneous Raman spectroscopic method. This visible wavelength Raman technique allows the acquisition of quantitative. stable species concentration measurements from the flow.

Locke, Randy J.↗

NASA 2007 Western States Fire Missions (WSFM)

This viewgraph presentation describes the Western states Fire Missions (WSFM) that occurred in 2007. The objectives of this mission are: (1) Demonstrate capabilities of UAS to overfly and collect sensor data on widespread fires throughout Western US. (1) Demonstrate long-endurance mission capabilities (20-hours+). (2) Image multiple fires (greater than 4 fires per mission), to showcase extendable mission configuration and ability to either linger over key fires or station over disparate regional fires. (3) Demonstrate new UAV-compatible, autonomous sensor for improved thermal characterization of fires. (4) Provide automated, on-board, terrain and geo-rectified sensor imagery over OTH satcom links to national fire personnel and Incident commanders. (5) Deliver real-time imagery to (within 10-minutes of acquisition). (6) Demonstrate capabilities of OTS technologies (GoogleEarth) to serve and display mission-critical sensor data, coincident with other pertinent data elements to facilitate information processing (WX data, ground asset data, other satellite data, R/T video, flight track info, etc).

Buoni, Greg↗

NASA Tech Briefs, August 2008

Customizable Digital Receivers for Radar Two-Camera Acquisition and Tracking of a Flying Target Visual Data Analysis for Satellites A Data Type for Efficient Representation of Other Data Types Hand-Held Ultrasonic Instrument for Reading Matrix Symbols Broadband Microstrip-to-Coplanar Strip Double-Y Balun A Topographical Lidar System for Terrain-Relative Navigation Programmable Low-Voltage Circuit Breaker and Tester Electronic Switch Arrays for Managing Microbattery Arrays Topics covered include: Lower-Dark-Current, Higher-Blue-Response CMOS Imagers; Fabricating Large-Area Sheets of Single-Layer Graphene by CVD; Support for Diagnosis of Custom Computer Hardware; Providing Goal-Based Autonomy for Commanding a Spacecraft; Dynamic Method for Identifying Collected Sample Mass; Optimal Planning and Problem-Solving; Attitude-Control Algorithm for Minimizing Maneuver Execution Errors; Grants Document-Generation System; Heat-Storage Modules Containing LiNO3 3H2O and Graphite Foam; Precipitation-Strengthened, High-Temperature, High-Force Shape Memory Alloys; Improved Relief Valve Would Be Less Susceptible to Failure; Safety Modification of Cam-and-Groove Hose Coupling; Using Composite Materials in a Cryogenic Pump; Using Electronic Noses to Detect Tumors During Neurosurgery; Producing Newborn Synchronous Mammalian Cells; Smaller, Lower-Power Fast-Neutron Scintillation Detectors; Rotationally Vibrating Electric-Field Mill; Estimating Hardness from the USDC Tool-Bit Temperature Rise; Particle-Charge Spectrometer; Automated Production of Movies on a Cluster of Computers; FIDO-Class Development Rover; and Tone-Based Command of Deep Space Probes Using Ground Antennas.

Source record↗

Passive Neutron Instrumentation and Applications

This chapter presents a description of most of the instruments that are currently in use for the measurement of plutonium and uranium using passive methods (without an external source). This includes the acquisition electronics as well as Singles counting methods, coincidence counting methods and multiplicity counting methods. The Singles counting applications include the measurement of waste and curium bearing materials. The coincidence counting applications include bulk plutonium, bulk uranium, waste and holdup measurements and fresh fuel assemblies. The multiplicity application description includes advantages and disadvantages and multiplicity detector design. There is also a description of some non-3He systems. The chapter concludes with a description of additional concepts: neutron imagers, list-mode data analysis, distributed source term analysis, unattended monitoring and MCNP modeling for detector design.

Coincidence shift register↗

Low latency optical-based mode tracking with machine learning deployed on FPGAs on a tokamak

Active feedback control in magnetic confinement fusion devices is desirable to mitigate plasma instabilities and enable robust operation. Optical high-speed cameras provide a powerful, non-invasive diagnostic and can be suitable for these applications. Here, in this study, we process high-speed camera data, at rates exceeding 100 kfps, on in situ field-programmable gate array (FPGA) hardware to track magnetohydrodynamic (MHD) mode evolution and generate control signals in real time. Our system utilizes a convolutional neural network (CNN) model, which predicts the n = 1 MHD mode amplitude and phase using camera images with better accuracy than other tested non-deep-learning-based methods. By implementing this model directly within the standard FPGA readout hardware of the high-speed camera diagnostic, our mode tracking system achieves a total trigger-to-output latency of 17.6 μs and a throughput of up to 120 kfps. This study at the High Beta Tokamak-Extended Pulse (HBT-EP) experiment demonstrates an FPGA-based high-speed camera data acquisition and processing system, enabling application in real-time machine-learning-based tokamak diagnostic and control as well as potential applications in other scientific domains.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of spectral/radiometric characteristics of the thematic mapper for land use applications

The previous characterization of scan-related low-frequency noise was confirmed and extended through analysis of reflective-band data from another nighttime acquisition. Amplitude and phase relationships of the level shifts were determined for each detector in each of free full frames. Analysis of scan-direction-related signal droop effects in nighttime data from the reflective bands was begun with encouraging initial observations. Also, an effort to characterize high-frequency noise in the reflective bands through Fourier analysis of nighttime data was initiated. Recommendations are made relative to the choice of radiometric calibration constants in the thematic mapper image processing system for the routine processing of TM data. Non-linear (piece-wise linear) calibration curves are recommended.

Malila, W. A.↗

Imaging spectrometer measurement of water vapor in the 400 to 2500 nm spectral region

The Airborne Visible-Infrared Imaging Spectrometer (AVIRIS) measures the total upwelling spectral radiance from 400 to 2500 nm sampled at 10 nm intervals. The instrument acquires spectral data at an altitude of 20 km above sea level, as images of 11 by up to 100 km at 17x17 meter spatial sampling. We have developed a nonlinear spectral fitting algorithm coupled with a radiative transfer code to derive the total path water vapor from the spectrum, measured for each spatial element in an AVIRIS image. The algorithm compensates for variation in the surface spectral reflectance and atmospheric aerosols. It uses water vapor absorption bands centered at 940 nm, 1040 nm, and 1380 nm. We analyze data sets with water vapor abundances ranging from 1 to 40 perceptible millimeters. In one data set, the total path water vapor varies from 7 to 21 mm over a distance of less than 10 km. We have analyzed a time series of five images acquired at 12 minute intervals; these show spatially heterogeneous changes of advocated water vapor of 25 percent over 1 hour. The algorithm determines water vapor for images with a range of ground covers, including bare rock and soil, sparse to dense vegetation, snow and ice, open water, and clouds. The precision of the water vapor determination approaches one percent. However, the precision is sensitive to the absolute abundance and the absorption strength of the atmospheric water vapor band analyzed. We have evaluated the accuracy of the algorithm by comparing several surface-based determinations of water vapor at the time of the AVIRIS data acquisition. The agreement between the AVIRIS measured water vapor and the in situ surface radiometer and surface interferometer measured water vapor is 5 to 10 percent.

Green, Robert O.↗