Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “helicity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Optimization of a Seeded Free-Electron Laser with Helical Undulators

Seeded single pass free-electron lasers are promising coherent, short-duration, and intense light sources, from the visible to x rays. Operated with adjustable undulators, they are also a unique device for providing fully variable polarized radiation. We report here the first seeding of helical undulators with a variable polarized source. We demonstrate that the adjustment of the seed polarization and focusing allows the free-electron laser radiation to be optimized in terms of intensity and quality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Insight into the Narrow Structure in η Photoproduction on the Neutron from Helicity-Dependent Cross Sections

Here, the double polarization observable E and the helicity dependent cross sections σ 1/2 and σ 3/2 were measured for η photoproduction from quasifree protons and neutrons. The circularly polarized tagged photon beam of the A2 experiment at the Mainz MAMI accelerator was used in combination with a longitudinally polarized deuterated butanol target. The almost 4π detector setup of the Crystal Ball and TAPS is ideally suited to detect the recoil nucleons and the decay photons from η→2γ and η→3π 0 . The results show that the narrow structure previously observed in η photoproduction from the neutron is only apparent in σ 1/2 and hence, most likely related to a spin-1/2 amplitude. Nucleon resonances that contribute to this partial wave in η production are only N1/2 – (S11) and N1/2 + (P 11 ). Furthermore, the extracted Legendre coefficients of the angular distributions for σ1/2 are in good agreement with recent reaction model predictions assuming a narrow resonance in the P 11 wave as the origin of this structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proton Isovector Helicity Distribution on the Lattice at Physical Pion Mass

We present a state-of-the-art calculation of the isovector quark helicity Bjorken-x distribution in the proton using lattice-QCD ensembles at the physical pion mass. We compute quasi-distributions at proton momenta P z ϵ {2.2; 2.6; 3.0} GeV on the lattice, and match them systematically to the physical parton distribution using large-momentum effective theory (LaMET).We reach an unprecedented precision through high statistics in simulations, large-momentum proton matrix elements, and control of excited-state contamination. The resulting distribution with combined statistical and systematic errors is in agreement with the latest phenomenological analysis of the spin-dependent experimental data; in particular, Δ$\bar{u}$(x) > Δ$\bar{d}$(x).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phononic Helical Nodal Lines with PT Protection in MoB 2

While condensed matter systems host both fermionic and bosonic quasiparticles, reliably predicting and empirically verifying topological states is only mature for Fermionic electronic structures, leaving topological Bosonic excitations sporadically explored. This is unfortunate, as Bosonic systems such as phonons offer the opportunity to assess spinless band structures where nodal lines can be realized without invoking special additional symetries to protect against spin-orbit coupling. Here we combine first-principles calculations and meV-resolution inelastic x-ray scattering to demonstrate the first realization of parity-time reversal symmetry protected helical nodal lines in the phonon spectrum of MoB 2 . This structure is unique to phononic systems as the spin-orbit coupling present in electronic systems tends to lift the degeneracy away from high-symmetry locations. Our study establishes a protocol to accurately identify topological Bosonic excitations, opening a new route to explore exotic topological states in crystalline materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hopf Solitons in Helical and Conical Backgrounds of Chiral Magnetic Solids

Three-dimensional topological solitons attract a great deal of interest in fields ranging from particle physics to cosmology, but remain experimentally elusive in solid-state magnets. Here we numerically predict magnetic heliknotons, an embodiment of such nonzero-Hopf-index solitons localized in all spatial dimensions while embedded in a helical or conical background of chiral magnets. In this work we describe conditions under which heliknotons emerge as metastable or ground-state localized nonsingular structures with fascinating knots of magnetization field in widely studied materials. We demonstrate magnetic control of three-dimensional spatial positions of such solitons, as well as show how they interact to form moleculelike clusters and possibly even crystalline phases comprising three-dimensional lattices of such solitons with both orientational and positional order. Finally, we discuss both fundamental importance and potential technological utility of magnetic heliknotons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Celestial Dual for Maximal Helicity Violating Amplitudes

It is shown that a 2D conformal field theory consisting of a central charge c Liouville theory, a chiral level one, rank N Kac-Moody algebra, and a weight − 3 / 2 free fermion holographically generate 4D maximal helicity violating tree-level scattering amplitudes. The correlators of this 2D conformal field theory give directly the 4D leaf amplitudes associated to a single hyperbolic slice of flat space. The 4D celestial amplitudes arise in a large- N and semiclassical large- c limit, according to the holographic dictionary, as a translationally invariant combination of leaf amplitudes. A step in the demonstration is showing that the semiclassical limit of Liouville correlators are given by contact 3D anti–de Sitter Witten diagrams. Published by the American Physical Society 2024

Physics↗

Topological Defect Mediated Helical Phase Reorientation by Uniaxial Stress

Strain engineering enables precise, energy-efficient control of nanoscale magnetism. However, unlike well-studied strain-dislocation interactions in mechanical deformation, the spatial evolution of strain-induced spin rearrangement remains poorly understood. Using Lorentz transmission electron microscopy, we manipulate and observe helical domain reorientation under quantitatively applied uniaxial tensile stress. Our findings reveal striking similarity to plastic deformation in metals, where the critical stress for propagation vector ( Q ) reorientation depends on its angle with the stress direction. Magnetic defects mediate reorientation via “break-and-reconnect” or “dislocation gliding–annihilation” processes. Simulations confirm that strain-induced anisotropic Dzyaloshinskii-Moriya interaction may play a key role. These insights advance strain-driven magnetism and offer a promising route for energy-efficient magnetic nanophase control in next-generation information technology. Published by the American Physical Society 2025

36 MATERIALS SCIENCE↗

Helicity is a topological invariant of massless particles: C = - 2 h

There is an elementary but indispensable relationship between the topology and geometry of massive particles. The geometric spin s is related to the topological dimension of the internal space V by dim⁡ V = 2⁢s + 1. This breaks down for massless particles, which are geometrically characterized by their helicity ℎ, but all have 1D internal spaces. We show that a subtler relation exists between the topology and geometry of massless particles. Wave functions of massless particles are sections of nontrivial line bundles over the light cone whose topology is completely characterized by their first Chern number C. We prove that in general C = -2⁢ℎ. In doing so, we also exhibit a method of generating all massless bundle representations via an Abelian group structure of massless particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The structure of the SBP-Tag–streptavidin complex reveals a novel helical scaffold bridging binding pockets on separate subunits

The structure of the SBP-Tag–streptavidin complex reveals a novel mode of peptide recognition in which a single peptide binds simultaneously to biotin-binding pockets from adjacent subunits of streptavidin. The molecular details of peptide recognition suggest how the SBP-Tag can be further modified to become an even more useful tag for a wider range of biotechnological applications. The 38-residue SBP-Tag binds to streptavidin more tightly (K{sub d} ≃ 2.5–4.9 nM) than most if not all other known peptide sequences. Crystallographic analysis at 1.75 Å resolution shows that the SBP-Tag binds to streptavidin in an unprecedented manner by simultaneously interacting with biotin-binding pockets from two separate subunits. An N-terminal HVV peptide sequence (residues 12–14) and a C-terminal HPQ sequence (residues 31–33) form the bulk of the direct interactions between the SBP-Tag and the two biotin-binding pockets. Surprisingly, most of the peptide spanning these two sites (residues 17–28) adopts a regular α-helical structure that projects three leucine side chains into a groove formed at the interface between two streptavidin protomers. The crystal structure shows that residues 1–10 and 35–38 of the original SBP-Tag identified through in vitro selection and deletion analysis do not appear to contact streptavidin and thus may not be important for binding. A 25-residue peptide comprising residues 11–34 (SBP-Tag2) was synthesized and shown using surface plasmon resonance to bind streptavidin with very similar affinity and kinetics when compared with the SBP-Tag. The SBP-Tag2 was also added to the C-terminus of β-lactamase and was shown to be just as effective as the full-length SBP-Tag in affinity purification. These results validate the molecular structure of the SBP-Tag–streptavidin complex and establish a minimal bivalent streptavidin-binding tag from which further rational design and optimization can proceed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Controlling beam trajectory and transport in a tapered helical undulator

In this paper we present a detailed discussion of the helical undulator system developed for high extraction efficiency experiments in the tapered-enhanced stimulated superradiant amplification regime. The design is based on permanent magnet technology and comprises two Halbach arrays orthogonally oriented and shifted by 90° with respect to each other. When used in low energy beamlines for THz generation, the electron beam trajectory and transport are particularly sensitive to the undulator off-axis fields so that it becomes important to complement on-axis field measurements with analysis and tuning of the higher-order field components. Here we describe how the pulsed wire measurement technique can be effectively used to retrieve on- and off-axis magnetic field characteristics of the undulator. A simple two-dipole model is developed to guide the final adjustments to the permanent magnet positions along the array to tune the quadrupole and sextupole components of the field.

free-electron lasers↗

Development of a model superconducting helical undulator for the ILC positron source.

The helical undulator for the proposed International Linear Collider (ILC) positron source requires high-permeability steel poles and superconducting coils to meet the ILC parameters. A short-model undulator with a period of 14 mm was designed, fabricated including high-permeability steel poles, and tested in LHe. The ends of the model were designed to wind the Nb{sub 3}Sn double helix without any conductor joints. After a few quenches in the first excitation test, the current density in the coil reached 1.28 kA/mm{sup 2}, which was approximately 90% of the estimated short-sample critical current density. The periodic on-axis fields were mapped at two azimuth angles. Excluding the end fields, the standard deviation of the field amplitudes and higher harmonic coefficients for the periodic field were less than 7 x 10{sup -3} and 5 x 10{sup -3}, respectively.

36 MATERIALS SCIENCE↗

Measuring Helical FCG Voltage with an Electric Field Antenna

A method of measuring the voltage produced by a helical explosive flux compression generator using a remote electric field antenna is described in detail. The diagnostic has been successfully implemented on several experiments. Measured data from the diagnostic compare favorably with voltages predicted using the code CAGEN, validating our predictive modeling tools. The measured data is important to understanding generator performance, and is measured with a low-risk, minimally intrusive approach.

42 ENGINEERING↗

Rotation magnet sputtering: Damage-free novel magnetron sputtering using rotating helical magnet with very high target utilization

Novel magnetron-sputtering equipment, called rotation magnet sputtering (ROT-MS), was developed to overcome various disadvantages of current magnetron-sputtering equipment. Disadvantages include (1) very low target utilization of less than 20%, (2) difficulty in obtaining uniform deposition on the substrate, and (3) charge-up damages and ion-bombardment-induced damages resulting from very high electron temperature (>3 eV) and that the substrate is set at the plasma excitation region. In ROT-MS, a number of moving high-density plasma loops are excited on the target surface by rotating helical magnets, resulting in very high target utilization with uniform target erosion and uniform deposition on the substrate. This excellent performance can be principally maintained even if equipment size increases for very large-substrate deposition. Because strong horizontal magnetic fields (>0.05 T) are produced within a very limited region just at the target surface, very low electron-temperature plasmas (<2.5 eV for Ar plasma and <1 eV for direct-current-excited Xe plasma) are excited at the very limited region adjacent to the target surface with a combination of grounded plate closely mounted on the strong magnetic field region. Consequently, the authors can establish charge-up damage-free and ion-bombardment-induced damage-free processes. ROT-MS has been applied for thin-film formation of LaB{sub 6}, which is well known as a stable, low-work-function bulk-crystal material for electron emissions. The work function of the LaB{sub 6} film decreased to 2.8 eV due to enhanced (100)-orientation crystallinity and reduced resistivity realized by adjusting the flux of low-energy bombarding ions impinging on the depositing surface, which work very efficiently, improving the performance of the electron emission devices.

36 MATERIALS SCIENCE↗

Comparison of fixed-beam IMRT, helical tomotherapy, and IMPT for selected cases

A growing number of advanced intensity modulated treatment techniques is becoming available. In this study, the specific strengths and weaknesses of four techniques, static and dynamic multileaf collimator (MLC), conventional linac-based IMRT, helical tomotherapy (HT), and spot-scanning proton therapy (IMPT) are investigated in the framework of biological, EUD-based dose optimization. All techniques were implemented in the same in-house dose optimization tool. Monte Carlo dose computation was used in all cases. All dose-limiting, normal tissue objectives were treated as hard constraints so as to facilitate comparability. Five patient cases were selected to offer each technique a chance to show its strengths: a deep-seated prostate case (for 15 MV linac-based IMRT), a pediatric case (for IMPT), an extensive head-and-neck case (for HT), a lung tumor (for HT), and an optical neurinoma (for noncoplanar linac-based IMRT with a miniMLC). The plans were compared by dose statistics and equivalent uniform dose metrics. All techniques delivered results that were comparable with respect to target coverage and the most dose-limiting normal tissues. Static MLC IMRT struggled to achieve sufficient target coverage at the same level of dose homogeneity in the lung case. IMPT gained the greatest advantage when lung sparing was important, but did not significantly reduce the risk of nearby organs. Tomotherapy and dynamic MLC IMRT showed mostly the same performance. Despite the apparent conceptual differences, all four techniques fare equally well for standard patient cases. The absence of relevant differences is in part due to biological optimization, which offers more freedom to shape the dose than do, e.g., dose volume histogram constraints. Each technique excels for certain classes of highly complex cases, and hence the various modalities should be viewed as complementary, rather than competing.

61 RADIATION PROTECTION AND DOSIMETRY↗

A motion-compensated scheme for helical cone-beam reconstruction in cardiac CT angiography

Since coronary heart disease is one of the main causes of death all over the world, cardiac computed tomography (CT) imaging is an application of very high interest in order to verify indications timely. Due to the cardiac motion, electrocardiogram (ECG) gating has to be implemented into the reconstruction of the measured projection data. However, the temporal and spatial resolution is limited due to the mechanical movement of the gantry and due to the fact that a finite angular span of projections has to be acquired for the reconstruction of each voxel. In this article, a motion-compensated reconstruction method for cardiac CT is described, which can be used to increase the signal-to-noise ratio or to suppress motion blurring. Alternatively, it can be translated into an improvement of the temporal and spatial resolution. It can be applied to the entire heart in common and to high contrast objects moving with the heart in particular, such as calcified plaques or devices like stents. The method is based on three subsequent steps: As a first step, the projection data acquired in low pitch helical acquisition mode together with the ECG are reconstructed at multiple phase points. As a second step, the motion-vector field is calculated from the reconstructed images in relation to the image in a reference phase. Finally, a motion-compensated reconstruction is carried out for the reference phase using those projections, which cover the cardiac phases for which the motion-vector field has been determined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo calculation of helical tomotherapy dose delivery

Helical tomotherapy delivers intensity modulated radiation therapy using a binary multileaf collimator (MLC) to modulate a fan beam of radiation. This delivery occurs while the linac gantry and treatment couch are both in constant motion, so the beam describes, from a patient/phantom perspective, a spiral or helix of dose. The planning system models this continuous delivery as a large number (51) of discrete gantry positions per rotation, and given the small jaw/fan width setting typically used (1 or 2.5 cm) and the number of overlapping rotations used to cover the target (pitch often <0.5), the treatment planning system (TPS) potentially employs a very large number of static beam directions and leaf opening configurations to model the modulated fields. All dose calculations performed by the system employ a convolution/superposition model. In this work the authors perform a full Monte Carlo (MC) dose calculation of tomotherapy deliveries to phantom computed tomography (CT) data sets to verify the TPS calculations. All MC calculations are performed with the EGSnrc-based MC simulation codes, BEAMnrc and DOSXYZnrc. Simulations are performed by taking the sinogram (leaf opening versus time) of the treatment plan and decomposing it into 51 different projections per rotation, as does the TPS, each of which is segmented further into multiple MLC opening configurations, each with different weights that correspond to leaf opening times. Then the projection is simulated by the summing of all of the opening configurations, and the overall rotational treatment is simulated by the summing of all of the projection simulations. Commissioning of the source model was verified by comparing measured and simulated values for the percent depth dose and beam profiles shapes for various jaw settings. The accuracy of the MLC leaf width and tongue and groove spacing were verified by comparing measured and simulated values for the MLC leakage and a picket fence pattern. The validated source and MLC configuration were then used to simulate a complex modulated delivery from fixed gantry angle. Further, a preliminary rotational treatment plan to a delivery quality assurance phantom (the 'cheese' phantom) CT data set was simulated. Simulations were compared with measured results taken with an A1SL ionization chamber or EDR2 film measurements in a water tank or in a solid water phantom, respectively. The source and MLC MC simulations agree with the film measurements, with an acceptable number of pixels passing the 2%/1 mm gamma criterion. 99.8% of voxels of the MC calculation in the planning target volume (PTV) of the preliminary plan passed the 2%/2 mm gamma value test. 87.0% and 66.2% of the voxels in two organs at risk (OARs) passed the 2%/2 mm tests. For a 3%/3 mm criterion, the PTV and OARs show 100%, 93.2%, and 86.6% agreement, respectively. All voxels passed the gamma value test with a criterion of 5%/3 mm. The TomoTherapy TPS showed comparable results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Regularized iterative weighted filtered backprojection for helical cone-beam CT

Contemporary reconstruction methods employed for clinical helical cone-beam computed tomography (CT) are analytical (noniterative) but mathematically nonexact, i.e., the reconstructed image contains so called cone-beam artifacts, especially for higher cone angles. Besides cone artifacts, these methods also suffer from windmill artifacts: alternating dark and bright regions creating spiral-like patterns occurring in the vicinity of high z-direction derivatives. In this article, the authors examine the possibility to suppress cone and windmill artifacts by means of iterative application of nonexact three-dimensional filtered backprojection, where the analytical part of the reconstruction brings about accelerated convergence. Specifically, they base their investigations on the weighted filtered backprojection method [Stierstorfer et al., Phys. Med. Biol. 49, 2209-2218 (2004)]. Enhancement of high frequencies and amplification of noise is a common but unwanted side effect in many acceleration attempts. They have employed linear regularization to avoid these effects and to improve the convergence properties of the iterative scheme. Artifacts and noise, as well as spatial resolution in terms of modulation transfer functions and slice sensitivity profiles have been measured. The results show that for cone angles up to {+-}2.78 deg., cone artifacts are suppressed and windmill artifacts are alleviated within three iterations. Furthermore, regularization parameters controlling spatial resolution can be tuned so that image quality in terms of spatial resolution and noise is preserved. Simulations with higher number of iterations and long objects (exceeding the measured region) verify that the size of the reconstructible region is not reduced, and that the regularization greatly improves the convergence properties of the iterative scheme. Taking these results into account, and the possibilities to extend the proposed method with more accurate modeling of the acquisition process, the authors believe that iterative improvement with non-exact methods is a promising technique for medical CT applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biological effect of different IMRT delivery techniques: SMLC, DMLC, and helical tomotherapy

Purpose: Intensity-modulated radiotherapy (IMRT) is delivered using a variety of techniques with differing temporal dose characteristics. Spatial dose metrics are generally used to evaluate treatment plan quality. However, the use of this information alone neglects the effects of the significant differences in dose delivery duration and dose accumulation patterns, both of which can impact cell survival. This study uses the linear-quadratic model with dose protraction corrections to evaluate the biological effectiveness of different IMRT delivery techniques, including fixed gantry IMRT in SMLC (step-and-shoot) and DMLC (sliding window) modes and a rotational IMRT technique (helical tomotherapy) for the treatment of prostate and head/neck sites. Methods: The temporal dose pattern was measured using a small volume ion chamber (A1SL--0.057 cm{sup 3}) to calculate the protraction factor, and biological equivalent dose (BED) was calculated for a range of repair half-times and {alpha}/{beta} ratios. The treatment BED is compared to an ideal delivery of the target prescription dose, in which dose is delivered instantaneously (G(t{sub 0})=1), to evaluate loss in biological effectiveness due to protraction in delivery. In the case of a conventional prescription, the loss in biological effectiveness was further evaluated using published tumor control probability (TCP) data. Results: With SMLC and DMLC IMRT delivery, for both prostate and head/neck, the expected additional loss in BED is about 1% compared to 3D CRT, which corresponds to a predicted 2%-3% reduction in TCP. For tomotherapy, the prostate BED loss is smaller in comparison to 3D CRT; hence, the authors expect a TCP increase of the order of 2%-3%. The aforementioned differences are due to the dose accumulation time. Conclusions: While it is theoretically possible to compensate for changes in biologically effective dose, this would be hindered by large uncertainties in parameters used for such calculations; therefore, it is advantageous to irradiate target volume elements as rapidly as possible. The results of this study indicate that temporal dose delivery pattern is an important component in determining the biological effects of IMRT treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗