Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

The Effect of Cathode Composition on the Thermal Characteristics of Lithium-Ion Cells

The specific thermal capacity and heat dissipation rate for lithium ion cells containing LiNiO2 and mixed oxide (75%LiCoO2+ 25%LiNiO2) as cathode materials are compared. The experimental measurements were made using a radiative calorimeter consisting of a copper chamber maintained at -168 C by circulating liquid nitrogen and enclosed in a vacuum bell jar. The specific thermal capacity was determined based on warm-up and cool-down transients. The heat dissipation rate was calculated from the values measured for heat radiated and stored, and the resulting values were corrected for conductive heat dissipation through the leads. The specific heat was 1.117 J/ C-g for the LiNiO2 cell and 0.946 J/ C-g for the 75%LiCoO2,25%LiNiO2 cell. Endothermic cooling at the beginning of charge was very apparent for the cell containing 75%LiCoO2,25%LiNiO2 as the cathode. Exothermic heating began at a higher state of charge for the cell with the 75%LiCoO2,25%LiNiO2 cathode compared to the LiNiO2 cathode cell. During discharge, the rate of heat dissipation increased with increase in the discharge current for both types of cells. The maximum heat dissipated at C/5 discharge was 0.065 W and 0.04 W for the LiNiO2 and 75%LiCoO2,25%LiNiO2 cells, respectively, The thermoneutral potential showed variability toward the end of discharge. The plateau region of the curves was used to calculate average thermoneutral potentials of 3.698 V and 3.837 V for the LiNiO2 cell and the 75%LiCoO2,25%LiNiO2 cell, respectively.

Vaidyanathan, Hari↗

Extended Development of Variable Conductance Heat Pipes

A high-capacity vapor-modulated heat pipe was designed and tested. In 1977, a program was undertaken to use the aforementioned heat pipe to study protection from freezing-point failure, increase control sensitivity, and transient behavior under a wide range of operating conditions in order to determine the full performance potential of the heat pipe. A new concept, based on the vapor-induced-dry-out principle, was developed for passive feedback temperature control as a heat pipe diode. This report documents this work and describes: (1) the experimental and theoretical investigation of the performance of the vapor-modulated heat pipe; and (2) the design, fabrication and test of the heat pipe diode.

Antoniuk, D.↗

Resistance and Cooling Power of Various Radiators

This reports combines the wind tunnel results of radiator tests made at the Navy Aerodynamical Laboratory in Washington during the summers of 1921, 1925, and 1926. In all, 13 radiators of various types and capacities were given complete tests for figure of merit. Twelve of these were tested for resistance to water flow and a fourteenth radiator was tested for air resistance alone, its heat dissipating capacity being known. All the tests were conducted in the 8 by 8 foot tunnel, or in its 4 by 8 foot restriction, by the writer and under conditions as nearly the same as possible. That is to say, as far as possible, the general arrangement and condition of the apparatus, the observation intervals, the ratio of water flow per unit of cooling surface, the differential temperatures, and the air speeds were the same for all.

Smith, R H↗

Cryogenic Heat Pipe Experiment (CRYOHP)

The objective of the CRYOHP experiment is to conduct a shuttle experiment that demonstrates the reliable operation of two oxygen heat pipes in microgravity. The experiment will perform the following tasks: (1) demonstrate startup of the pipes from the supercritical state; (2) measure the heat transport capacity of the pipes; (3) measure evaporator and condenser film coefficients; and (4) work shuttle safety issues. The approach for the experiment is as follows: (1) fly two axially grooved oxygen heat pipes attached to mechanical stirling cycle tactical coolers; (2) integrate experiment in hitch-hiker canister; and (3) fly on shuttle and control from ground.

Mcintosh, Roy↗

High capacity demonstration of honeycomb panel heat pipes

The feasibility of performance enhancing the sandwich panel heat pipe was investigated for moderate temperature range heat rejection radiators on future-high-power spacecraft. The hardware development program consisted of performance prediction modeling, fabrication, ground test, and data correlation. Using available sandwich panel materials, a series of subscale test panels were augumented with high-capacity sideflow and temperature control variable conductance features, and test evaluated for correlation with performance prediction codes. Using the correlated prediction model, a 50-kW full size radiator was defined using methanol working fluid and closely spaced sideflows. A new concept called the hybrid radiator individually optimizes heat pipe components. A 2.44-m long hybrid test vehicle demonstrated proof-of-principle performance.

Tanzer, H. J.↗

An Online Tool for Preliminary Design and Techno-Economic Analysis of District Geothermal Heating and Cooling Systems

District geothermal heating and cooling systems (DGHCS) have significant benefits for reducing energy consumption as well as building- and grid-level peak electric demand. Currently, no publicly available tools are available to effectively design and conduct techno-economic analysis of DGHCS. GeoWISE was originally developed for preliminary design and techno-economic analysis of geothermal heating and cooling systems in an individual commercial or residential building. This paper introduces recent upgrades of GeoWISE that allow users to design and conduct techno-economic analysis of DGHCS. Several new features are implemented in GeoWISE to allow selection and specification of multiple new or existing buildings. A database of information for over 125 million existing U.S. buildings was used in GeoWISE that allows users easily locate existing buildings of interest based on street addresses, and optionally edit information of the buildings (e.g., footprint, vintage, principal functions, number of floors, window-to-wall ratio). Unique energy simulation models of the selected buildings are then automatically created using the Automatic Building Energy Modeling (AutoBEM) and EnergyPlus simulations are performed to predict thermal loads of the buildings. A simplified DGHCS is then designed and simulated to predict its energy use. A central borehole heat exchanger (BHE) of the DGHCS is sized using the RowWise algorithm of GHEDesigner to meet the thermal loads within user-specified land areas for installing BHE. The upgraded GeoWISE reports the needed capacity of heating and cooling equipment in each building, design of the central BHE, energy consumption reduction, and energy cost saving resulting from using DGHCS compared with conventional HVAC systems. A case study is showcased using the upgraded GeoWISE to design and conduct techno-economic analysis of a simplified DGHCS.

Prem Anand Jayaprabha, Jyothis Anand [ORNL] (ORCID↗

Fairfax County Urban Development: Identifying Urban Heat Mitigation Strategies for Climate Adaptation Planning in Fairfax County, Virginia

Extreme high temperatures lead to increased instances of cardiovascular disease, pulmonary disease, and even death, as well as increased energy consumption and infrastructure costs. People in urbanized areas experience higher temperatures than rural areas due to diminished vegetation and increased impervious surfaces which absorb and radiate heat. Fairfax County, Virginia has embarked on Resilient Fairfax, a program aimed at addressing climate adaptation and resilience. The DEVELOP team partnered with the Fairfax County Office of Environmental and Energy Coordination (OEEC) to assess the extent of the urban heat island effect on the county and its most vulnerable populations. The team used data from Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS), as well as the ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) for the years 2013 to 2021 and found that the hottest spots were in densely urbanized areas, with temperatures as much as 47°F above that of undeveloped reference areas. The team used the Integrated Valuation of Ecosystem Services and Tradeoffs (InVEST) urban cooling model and determined that areas with higher tree canopy cover had greater heat mitigation capacity. Estimates from the InVEST model showed that a 4.5% increase in canopy cover across the county could result in a temperature reduction of up to 2.4°F in some areas. The results will allow partners to assess heat distribution across Fairfax County and implement effective mitigation strategies, including locating prime locations for cooling centers and increasing canopy cover.

W. Pierce Holloway↗

An improved high power hybrid capillary pumped loop

In order to improve performance testing, NASA's High-Power Spacecraft Thermal Management system has been modified through (1) an augmentation of heat-dissipation capacity of the condenser sink for steady-state high power operation, (2) the addition of more pressure transducers for pressure-drop monitoring in various system components, (3) the installation of pressure-contact thermocouples on the evaporators to measure heating surface temperature, (4) the provision of a coolant loop to one of the evaporator plates, (5) the placing of a transient fluid flow-monitoring load cell in the reservoir, and (6) the reorientation of the reservoir to reduce compressed vapor effects. The system is now capable of 10 hours of continuous capillary mode operation at an input power level of 20 kW.

Ku, Jentung↗

Phase Change Material for Temperature Control of Loop Heat Pipe Compensation Chamber

The compensation chamber (CC) of a loop heat pipe (LHP) requires a stable temperature. In the current technology, the CC is commonly cold biased by exposing it to deep space, and active heater control is used to maintain its temperature stable. Heater power required for a typical LHP with a 300 W heat transport capacity is as much as 25 W. If multiple LHPs are used, heater power requirement could be a bigger issue. Also heater controller or temperature sensor failure could lead to a LHP or mission failure. This paper presents an innovative concept of using phase change material (PCM) for temperature control of LHP CC. Some of the electronics and/or detector assembly waste heat is stored in the PCM and transferred to the LHP CC by constant conductance heat pipes (CCHPs). Phase change of the PCM occurs at a constant temperature and maintains the LHP CC temperature stable. It eliminates heater power and active heater control for the CC. It also increases the reliability of LHP.

Choi, Michael K.↗

EVALUATION OF OPERATION TEMPERATURES UNDER NATURAL CONVECTION HELIUM FLOW IN A CONFINED CAVITY

The Spallation Neutron Source (SNS) is a high-power accelerator-based pulsed neutron source led by Oak Ridge National Laboratory (ORNL) to achieve high fluxes of neutrons for scientific experiments. Active and passive cooling of the systems and parts forming the SNS have been considered to warrant the safe operation of the facility. The diverse cooling systems make use of conjugated heat transfer mechanisms to provide a stable operation temperature for all components in the machine. Thermal power deposited into stainless-steel piping lines due to particle radiation may reach values of up to 1.2 W/cc in the regions located closer to the center of the lower IRP. These energy deposition levels, in not actively cooled components, such as the transfer-line-outer-vacuum-layer may increase the temperature of the component beyond design requirement limitations. The evaluation of the operation temperatures for the former components relies in the assumption that a low-pressure helium atmosphere provides enough heat removal capacity based on natural convection phenomena. In this work, the evaluation of steady state temperatures in components such as the CMS transfer lines has been evaluated using computational fluid dynamics (CFD), analytical correlations and experimental measurements. The companion experiments were conducted in a closed helium system at pressures varying from 1.1 to 1.5 bar. A copper rod was affixed horizontally between viewing windows and heated at constant power, and measurements were made of both the rod temperature and ambient temperature via a system fiberoptic distributed temperature sensors and RTDs. It was found that the measured heat transfer coefficients agree well with the predictions of Churchill and Chu correlations across the range of cases considered. Additionally, the ambient helium volume above the rod was imaged via background oriented schlieren (BOS), and these data was used to determine the line-averaged density gradients in this region. These gradients were compared to simulation data to validate the predictions of natural convection simulations.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Modeled Results of Four Residential Energy Efficiency Measure Packages for Deriving Advanced Building Construction Research Targets

The Advanced Building Construction (ABC) Initiative from the U.S. Department of Energy Building Technologies Office is working to accelerate industrialized construction innovations for decarbonizing buildings. To inform performance and cost targets for research under the ABC Initiative, this analysis used the ResStock™ tool to evaluate the energy savings, utility bill impacts, and carbon emissions impacts of four simulated upgrade packages with specific target performance levels on a large sample of residential dwelling units (approximately 550,000) representative of the U.S. housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of a prototypical natural circulation water-based reactor cavity cooling system (RCCS) for a pebble-bed generic FHR

A prototypical natural circulation water-based reactor cavity cooling system (RCCS) for the UC Berkeley Mark-1 pebble-bed gFHR is designed based on one-dimensional thermal hydraulics modeling and optimization implemented in an in-house MATLAB code. The model employs a lumped core consisting of fuel pebble and graphite pebble regions, while the graphite reflector, vessel, and RCCS are represented as separate but energy-coupled regions. The model is derived based on steady state energy balance equations accounting for conductive heat transfer from the lumped core to the vessel and subsequent radiative heat transfer to the RCCS and convective heat transfer in the water. Further, mass flow rate is calculated based on momentum and thermal energy balance in the RCCS. Starting with ANL’s water NSTF as baseline, effects of RCCS design parameters such as size of the plate between pipes, pipe diameter, source-to-sink distance, surface emissivity, and pitch from the core are examined in an integral effects framework which accounts for subsequent variation of the mass flow rate, number of pipes, convection coefficient, mean region and surface temperatures, radiative view factors, and water outlet temperature. The importance of including a prototypical reactor design in RCCS design calculations is emphasized as the calculations show that temperature drops from the core to the RCCS fluid to transfer the heat tend to be the limitation not the heat removal capacity of the fluid. A closed-loop design is obtained with capability to safely remove up to 0.72% of the nominal reactor power at maximum estimated peak conditions and 0.40% at shutdown. The design is based on physics calculations and does not account for economic optimization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Two-Phase Cooling for High Packaging Density Planar Inverter: Cooperative Research and Development Final Report, CRADA Number CRD-15-00592

The project objective was to utilize two-phase heat transfer to enable compact and power-dense inverters. The high heat transfer capacity and near isothermal characteristics of two-phase cooling can enable higher power densities, reducing the size and cost of the power electronics system. This project focused on developing efficient, passive (no pump or compressor) two-phase cooling strategies that consist of an air-cooled condenser and evaporator. This report describes the modeling work conducted to design the evaporator and air-cooled condenser for a prototype inverter development work underway in the John Deere. Prototypes of the final evaporator and condenser designs were then fabricated via 3D printing for testing. Experiments on the evaporator confirmed that this component can meet the heat load and junction temperatures requirements for Si IGBT (insulated-gate bipolar transistor) inverter. Experiments with the air-cooled condenser were not possible due to leaks through the condenser walls.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluation and selection of eutectic salts combined with metal foams for applications in high-temperature latent heat thermal energy storage

This study presents a systematic process for selecting eutectic salts for use in latent heat thermal energy storage (LHTES), and provides experimental evidence regarding their performance. One primary goal was to identify the most suitable eutectic salt for use with metallic foams over a temperature range of 450 °C–500 °C. Twenty-one eutectic salts were preselected for comparison. Here, the performance and cost-effectiveness of each were evaluated based on the Ragone relation, enabling a fair comparison of each salt's heat storage capacity and power density relative to cost. As a result, MgCl-NaCl, CaCl 2 -NaCl, and FLiNaK were selected as the most promising candidates. Subsequently, experiments were performed to demonstrate the compatibility of the selected salts with metal foams while the copper and aluminum foams were immersed in the salts at 550 °C for 120 h. Combining C10100 (copper alloy) foam with CaCl 2 -NaCl was observed to generate the least surface corrosion due to oxidation. The charge/discharge performance and thermal stability of CaCl 2 -NaCl, both with and without the copper foam, were also tested to confirm the feasibility of this combination. The capsule with the copper foam showed enhanced performance (a 13 % reduced discharge rate) in comparison to the capsule without copper foam. The melting point of the CaCl 2 -NaCl remained unchanged for 300-h duration of the cyclic melting/solidification experiments, and no thermal stability issues were observed.

25 ENERGY STORAGE↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Alkylamine Incorporation in Porous Polymer Networks through Dopant Incorporation

The industrial scale capture of CO 2 from flue gas streams is becoming an increasingly important environmental issue. However, many of the existing CO 2 capture systems either have regenerative energy demands that are too high or are cost prohibitive. A promising solution is the utilization of functionalized solid sorbents, such as porous polymer networks (PPNs). PPNs are attractive due to their inherent structural stability, flexibility, high surface areas, and ability to incorporate various functional groups within the chemical scaffold. Herein, a low cost, scalable alternative to common carbon capture systems using a series of robust mesoporous melamine-formaldehyde resins (mPMFs) loaded with active alkylamine sorbents is presented, which is dubbed as the PPN-150 family. The variants within this material class are differentiated based on the incorporation of functionalized dopants; small molecules added at low molar percent concentrations to impart additional functionality into the PPN in order to achieve low cost noncovalent tethering of alkylamines. The cyanuric acid doped PPN-151-DETA (DETA = diethylenetriamine) demonstrate unique features such as improved cycling capacity and heat of adsorption. To show its scalability, PPN-151-DETA is successfully synthesized at the 250 g scale without loss of the sorbent properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Negative thermal expansion coefficient and amorphization in defective 4H-SiC

This paper presents thermal expansion coefficient (TEC) and amorphization in 4H-SiC containing point defects at different concentrations. We considered vacancy defects, interstitial defects, and Frenkel pair defects and investigated the thermomechanical response of the lattice over a wide range of temperatures using classical molecular dynamics simulations. The results show that 4H-SiC with vacancy defects exhibits a negative TEC above a critical defect density of around 9% (irrespective of the temperature). With interstitial defects, it exhibits a positive TEC (regardless of the defect density), and with Frenkel pair defects it shows a transition from positive TEC to negative TEC for a defect density greater than 8%. The coupling between temperature-induced expansion and defect-introduced stress in the lattice forms the mechanistic basis for the observed variation in TEC. Furthermore, the specific heat decreases rapidly with an increase in defect density at room temperature, with the highest sensitivity of the lattice observed for the Frenkel pair defects followed by interstitial defects and then by vacancy defects. Finally, these findings highlight the critical implications of defects on thermal expansion behavior of 4H-SiC with applications in radiation environments.

36 MATERIALS SCIENCE↗