Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Electrolytic Renewable Fuel Production Optimal Operation Investigation - H2@Scale: Cooperative Research and Development Final Report, CRADA Number CRD-19-00818

This work explored the optimal design and operation of electrolytic hydrogen production from renewable power. While there are many financial incentives for renewable hydrogen, this work investigated the effects of Low Carbon Fuel Standards (LCFS) on the hydrogen breakeven cost. To this end, this project developed optimized operational strategies for electrolytic hydrogen facilities in the California. Four specific model projects were used as the basis for the analysis. Three model projects will be located in California and one in Texas or the Midwest to be determined during the project. All projects include interconnection to the natural gas grid as a method of transport for the product fuel and the hydrogen cases will also consider alternative modes of transport. The operational optimization will maximize project return through fuel production and grid services based on future scenarios for the value of each. The effort will rely on modeling tools developed by NREL and the UCI for grid modeling as well as the integrated resource planning tool (IRP), RESOLVE, which is the official IRP tool used by the California Public Utility Commission (CPUC). The development of this project can help to inform future hydrogen deployment, policy and regulation makers, research and development decisions, and private and public investment.

08 HYDROGEN↗

A Hierarchical Charging Control of Plug-in Electric Vehicles with Simple Flexibility Model

The demand for plug-in electric vehicles (PEVs) is increasing exponentially, which could have significant effects on the power grid, because charging one PEV is nearly equivalent to adding three houses to the power system. Even though PEVs increase demand on the electric grid, their capability to actively interact with the grid presents excellent opportunities for load management, demand response, and various other grid services. This paper proposes an innovative scheduling and control framework to enable smart PEV charging for grid services while meeting PEV owners’ travel needs. In the proposed framework, each set of electric vehicle supply equipment (EVSE) is equipped with a controller that estimates charging power and energy flexibility based on vehicle characteristics, EVSE power rating, battery energy state, and upcoming trip information. With the charging flexibility model received from each EVSE controller, the central coordinator determines the optimal power allocation for a look-ahead time window for the given grid services. The proposed charging coordination strategy can help reduce the computational complexity and communication requirement compared with existing methods. It is also scalable to the expanding PEV fleet and robust to uncertainties in upcoming vehicle trips and future system condition. The proposed method is studied using a prototypical feeder developed at Pacific Northwest National Laboratory and detailed trip information extracted from the National Household Travel Survey.

Wu, Di↗

Electrical Systems of Pumped Storage Hydropower Plants: Electrical Generation, Machines, Power Electronics, and Power Systems

Adjustable-speed (AS) pumped storage hydropower (PSH) technology has the potential to become a large, consistent contributor to grid stability enabling higher penetrations of wind and solar energy on the future U.S. power system. AS-PSH has high-value characteristics, such as fast response to provide ancillary services to the grid, because it is a power converter interface with the grid (like battery storage), but at the same time it has the energy content large enough to supply both short-term (seconds-to-minutes) and long-term (minutes-to-hours) of energy needs, like more conventional power plants. However, designs must be optimized to lower the capital expenditure (CapEx) and to provide a high-quality grid interface capability (e.g. power quality, ancillary service provider, fault-tolerant or fault ride-through capability), which is a primary factor in the acceptance of AS-PSH into a utility’s generation mix. This CapEx will be greatly affected by the cost savings associated with the civil structure, turbine design, power electronics, control systems, or unique generator designs. A holistic design must be considered to get a full picture of the benefits of the technology proposed. The AS-PSH can be controlled to reduce the impact of transient disturbance on a power system and at the same time can be controlled to minimized subsequent component fatigue and potential oscillation modes within the plant, with the overall impact in reducing the operational expenditures (OpEx).Generating clean power to meet standards such as Institute of Electrical and Electronics Engineers (IEEE) 519 and International Electrotechnical Commission (IEC) 1000-3-2 will be a continuing challenge. For many technology developers, however, improved AS-PSH technologies will become a key component of generator-storage systems of the future given the prospects of increased performance and decreasing costs, and the ever-increasing penetration of renewables (e.g wind power and solar power).

13 HYDRO ENERGY↗

Optimal Reconfiguaration and Resilient Control Framework for Real-Time Photopholtaic Dispatch to Manage Critical Infrastructure (ReDis-PV)

The consortium is conducting cutting-edge collaborative research that will allow advancing solar energy’s role in strengthening the resilience of the U.S. electricity grid. The U.S Department of Energy Solar Technologies Office (SETO) has awarded 4.6 million to Professor Sukumar Kamalasadan (The University of North Carolina at Charlotte) for the project “Optimal Reconfiguration and Resilient Control Framework for Real-Time Photovoltaic Dispatch to Manage Critical Infrastructure (ReDis-PV)”. The project developed a grid management tool that detects cyber and physical threats and forms dynamic clusters to manage photovoltaic and energy optimally. The project collaborating team includes the University of North Carolina at Charlotte, Clemson University, New Mexico State University, Florida International University, Argonne National Laboratory, Idaho National Laboratory, OPAL-RT Corporation, and Duke Energy.

14 SOLAR ENERGY↗

Depot Charging Schedule Optimization for Medium- and Heavy-Duty Battery-Electric Trucks

Charge management, which lowers charging costs for fleets and prevents straining the electrical grid, is critical to the successful deployment of medium- and heavy-duty battery-electric trucks (MHD BETs). This study introduces an energy demand and cost management framework that optimizes depot charging for MHD BETs by combining an energy consumption machine learning model and a linear program optimization model. The framework considers key factors impacting real-world MHD BET operations, including vehicle and charger configurations, duty cycles, use cases, geographic and climate conditions, operation schedules, and utilities’ time-of-use (TOU) rates and demand charges. The framework was applied to a hypothetical fleet of 100 MHD BETs in California under three different utilities for 365 days, with results compared to unmanaged charging. The optimized charging solution avoided more than 90% of on-peak charging, reduced fleet charging peak load by 64–75%, and lowered fleet energy variable costs by 54–64%. This study concluded that the proposed charge management framework significantly reduces energy costs and peak loads for MHD BET fleets while making recommendations for fleet electrification infrastructure planning and the design of utility TOU rates and demand charges.

Song, Shuhan↗

CGSim: A Simulation Framework for Large Scale Distributed Computing Environment

Large-scale distributed computing infrastructures such as the Worldwide LHC Computing Grid (WLCG) require comprehensive simulation tools for evaluating performance, testing new algorithms, and optimizing resource allocation strategies. However, existing simulators suffer from limited scalability, hardwired algorithms, lack of real-time monitoring, and inability to generate datasets suitable for modern machine learning approaches. We present CGSim, a simulation framework for large-scale distributed computing environments that addresses these limitations. Built upon the validated SimGrid simulation framework, CGSim provides high-level abstractions for modeling heterogeneous grid environments while maintaining accuracy and scalability. Key features include a modular plugin mechanism for testing custom workflow scheduling and data movement policies, interactive real-time visualization dashboards, and automatic generation of event-level datasets suitable for AI-assisted performance modeling. We demonstrate CGSim’s capabilities through a comprehensive evaluation using production ATLAS PanDA workloads, showing significant calibration accuracy improvements across WLCG computing sites. Scalability experiments show near-linear scaling for multi-site simulations, with distributed workloads achieving 6 × better performance compared to single-site execution. The framework enables researchers to simulate WLCG-scale infrastructures with hundreds of sites and thousands of concurrent jobs within practical time budget constraints on commodity hardware.

Vatsavai, Sairam Sri [Brookhaven National Laborato↗

A Nonlinear Direct Power Controller for a Three-Phase Grid-Connected Inverter with Online Parameter Update for PV Application

This work proposes a nonlinear direct power controller for a three-phase grid-connected inverter for photovoltaic application. Grid-connected converters for solar applications require advanced control architectures to ensure optimal operation and extraction of maximum power from the photovoltaic arrays. Therefore, to ensure this, a nonlinear power controller architecture has been proposed to extract the maximum power from the solar arrays and to achieve the most optimal operation. To further improve the performance, a parameter update scheme has been utilized which is based on model reference adaptive system. The latter helps to accomplish not only good dynamic response but also excellent tracking performance. The overall control come estimation architecture is verified based on computer simulations via MATLAB/Simulink and PLECS domain and various important case study results are presented.

direct power control↗

Load-Shifting Strategies for Cost-Effective Emission Reductions at Wastewater Facilities

Significant hourly variation in the carbon intensity of electricity supplied to wastewater facilities introduces an opportunity to lower emissions by shifting the timing of their energy demand. This shift could be accomplished by storing wastewater, biogas from sludge digestion, or electricity from on-site biogas generation. However, the life cycle emissions and cost implications of these options are not clear. Here, we present a multiobjective optimization framework for comparing cost- and emission-minimizing load-shifting strategies at a California case study facility with a relatively low carbon intensity grid and high spread in peak and off-peak electricity prices. We evaluate cost and emission trade-offs from the optimal flexible operation of both existing infrastructure and optimally sized energy flexibility upgrades. We estimate energy-related emission reductions of up to 9.0% with flexible operation of existing infrastructure and up to 16.8% with optimally sized storage upgrades. Only a fraction of these potential savings are realized under actual industrial energy tariffs and the EPA’s recommended social cost of carbon. Energy flexibility may hold promise as a short-term emission-saving solution for the wastewater sector, but the extent of savings is heavily dependent on the cost of carbon, electricity tariffs, and emission intensity of the regional electricity grid.

climate↗

Problem size, parallel architecture and optimal speedup

The communication and synchronization overhead inherent in parallel processing can lead to situations where adding processors to the solution method actually increases execution time. Problem type, problem size, and architecture type all affect the optimal number of processors to employ. The numerical solution of an elliptic partial differential equation is examined in order to study the relationship between problem size and architecture. The equation's domain is discretized into n sup 2 grid points which are divided into partitions and mapped onto the individual processor memories. The relationships between grid size, stencil type, partitioning strategy, processor execution time, and communication network type are analytically quantified. In so doing, the optimal number of processors was determined to assign to the solution, and identified (1) the smallest grid size which fully benefits from using all available processors, (2) the leverage on performance given by increasing processor speed or communication network speed, and (3) the suitability of various architectures for large numerical problems.

Nicol, David M.↗

Problem size, parallel architecture, and optimal speedup

The communication and synchronization overhead inherent in parallel processing can lead to situations where adding processors to the solution method actually increases execution time. Problem type, problem size, and architecture type all affect the optimal number of processors to employ. The numerical solution of an elliptic partial differential equation is examined in order to study the relationship between problem size and architecture. The equation's domain is discretized into n sup 2 grid points which are divided into partitions and mapped onto the individual processor memories. The relationships between grid size, stencil type, partitioning strategy, processor execution time, and communication network type are analytically quantified. In so doing, the optimal number of processors was determined to assign to the solution, and identified (1) the smallest grid size which fully benefits from using all available processors, (2) the leverage on performance given by increasing processor speed or communication network speed, and (3) the suitability of various architectures for large numerical problems.

Nicol, David M.↗

The Salem Smart Power Center: An Assessment of Battery Performance and Economic Potential

This paper presents an assessment of the economic potential of a 5 MW/1.25 MWh Energy Storage System (ESS) installed at the Salem Smart Power Center (SSPC), a smart grid technology demonstration facility owned and operated by Portland General Electric (PGE) in Salem, Oregon. The ESS and the grid conditions in which it operates were modeled using Pacific Northwest National Laboratory’s Battery Storage Evaluation Tool (BSET) to explore tradeoffs between services, and to develop optimal control strategies. This assessment monetized the value derived from nine services the SSPC could provide to PGE and the customers it serves. The ESS and the grid conditions in which it operates were modeled using PNNL’s in-house optimization tool BSET to explore tradeoffs between services, and to develop optimal control strategies. The analysis resulted in a number of lessons that provide crucial insights into the practical application of ESS, including; The SSPC, which was originally conceived as a research and test facility and built with the prevailing maturity technology level, was built at a cost ($20.4 million) that exceeds current day prices ($5.4 million) for a similarly designed and built 5 MW/1.25 MWh system; In terms of economic operation, the SSPC is currently underutilized, deployed only for primary frequency response. PNNL modeling indicates that optimal operation of the ESS could generate an additional value of $2.3 million over 20 years. It should also be noted that primary frequency response is the highest benefit application but requires a response from the SSPC only 17 hours each year. While optimally engaged, the ESS would provide arbitrage and ancillary services 78 percent of the time, but those services generate only 27 percent of the total value; Participation in Western EIM represents an interesting opportunity for PGE with a potential to generate $2.1 million value in PV terms over 20 years in the 5-min real-time market; With an energy to power ratio of only 0.25, the SSPC is not well suited to engage in most energy-intensive applications such as arbitrage or ancillary services. By upsizing the storage capacity to 5 MWh and 10MWh, the additional value allows the benefits ($13.3 million and 20.3 million, respectively) to exceed the system’s revenue requirements ($11.5 and $16.4 million, respectively). For the SSPC, ROI ratios exceeded 1.0 when the energy to power ratio fell between 0.5 and 3.5, and peaked at an energy to power ratio of 2.0. This report represents the output of the first of a two-phase effort. Phase II will involve the development of enhanced control strategies to assist PGE in realizing the benefits of energy storage in real-time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generic modelling and optimal day-ahead dispatch of micro-energy system considering the price-based integrated demand response

As an extension of micro-grid, micro-energy system (MES) is one of the important carriers for energy utilization in the future, and using energy prices as a controllable resource is conducive to improving the optimization potential of MES. Firstly, based on the energy hub model, a generic method for modelling the steady-state energy balance equation of MES is proposed. Then, considering the multi-energy substitution effect in the background of multi-energy coupling, the concept of price-based integrated demand response (P-IDR) is introduced. Meanwhile, based on the price elasticity theory and the discrete choice theory, the energy timing transfer characteristics and energy substitution characteristics in P-IDR is modelled. Furthermore, after taking into account the P-IDR, an MINLP model for day-ahead dispatch of MES is built, and a generalized benders decomposition method is used for solution. Case studies are conducted on an MES to verify the effectiveness of the proposed modelling method. Here, the result shows that it is beneficial to improve renewable energy accommodation and reduce the peak and off-peak difference of energy load when the P-IDR is deployed. In addition, consider the energy substitution characteristics can reduce the user’s cost on energy purchase and be more in line with the user’s rational consumption behaviour.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Day-ahead Scheduling for Microgrid Participation in Frequency Regulation Markets

As microgrid installations are steadily growing in the United States and around the world, widespread adoption of commercial microgrids would rely upon the economic benefit to the owners and operators. With the introduction of new market mechanisms and growing penetration of non-traditional generation assets, there is an increasing need and interest in allowing distributed assets to participate in traditional grid services such as frequency regulation. This paper considers the problem of determining the optimal balance of energy and ancillary services for individual microgrid generation assets to participate in such markets. An optimization framework that maximizes the predicted performance of the microgrid over a day-ahead time horizon while accounting for individual asset constraints is proposed. Simulation results on a realistic test system with practical considerations are presented.

microgrid frequency control ancillary services↗

A Real-Time Big Data Control-Theoretical Framework for Cyber-Physical-Human Systems [Book Chapter]

It is known that cyber-physical-human systems naturally arise from interdependent infrastructure systems and smart connected communities. Such applications require ubiquitous information sensing and processing, intelligent machine-to-machine communication for a seamless coordination, as well as intelligent interactions between humans and machines. This chapter presents a control-theoretical framework to model heterogeneous physical dynamic systems, information and communication, as well as cooperative controls and/or distributed optimization of such interconnected systems. It is shown that efficient analytical and computational algorithms can be modularly designed and hierarchically implemented to operate and optimize cyber-physical-human systems, first to quantify individually the input–output relationship of nonlinear dynamic behaviors of every physical subsystem, then to coordinate locally both cyber-physical interactions of neighboring agents as well as physical-human interactions, and finally to dynamically model and optimize the overall networked system. The hierarchical structure makes the overall optimization and control problem scalable and solvable. Moreover, the three levels integrate individual designs and optimization, distributed cooperative optimization, and decision-making through real-time, data-driven, model-based learning and control. Specifically, one of the contributions of the chapter is to demonstrate how the combination of dissipativity theory and cooperative control serves as a natural framework and promising tools to analyze, optimize, and control such large-scale system. Application to digital grid is investigated as an illustrative example.

97 MATHEMATICS AND COMPUTING↗

The impact of development priorities on power system expansion planning in sub-Saharan Africa

Sub-Saharan Africa faces unique barriers to electricity development due to the large proportion of the population that is un-electrified and the prevalence of rural populations. Typically, power system expansion planning models assume all potential consumers can be immediately electrified. This assumption is unrealistic in sub-Saharan Africa, where electrification will likely be a gradual process over a number of years. Furthermore, since a large proportion of the population in sub-Saharan Africa is located in rural regions, the prioritization of these regions may impact how the grid develops. In this research, we develop a multi-period optimization model for power generation and transmission system expansion planning in sub-Saharan Africa. In contrast to existing models, which assume full electrification, we consider a variety of electrification policies and analyze the impact of varying the electrification rate and policy on the cost and resources selected for power system expansion. We test our model on a case study of Rwanda. We find that varying the year in which full electrification is reached has a larger impact on cost and generation capacity than varying the electrification policy does, although, when urban and rural regions are considered equitably, more rooftop solar is built. Varying the electrification policies has a larger impact on transmission expansion than on generation expansion and this impact is amplified when starting from zero initial system capacity rather than the original Rwanda system. Additionally, a sensitivity analysis shows that tightening the bounds on CO 2eq emissions has a large impact on the generation portfolio and cost.

97 MATHEMATICS AND COMPUTING↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

An analysis of the spatio-temporal resolution of the immersed boundary method with direct forcing

The immersed boundary method (IBM) with direct forcing is very popular in the simulation of rigid particulate flows. In the IBM, an interaction force is introduced at the interface between fluid and particle in order to approximate the no-slip boundary condition. The interaction force is calculated through dividing the velocity difference (or error) between fluid and particle at the interface by the time step. Here, a dynamic equation for the velocity difference is derived. Additionally, analyses on the dynamic equation provide a few new findings: (i) The interaction force is the solution of a least-squares error problem, with the direct implication that the Lagrangian marker distribution has no effect on the large scale flow structure once the distribution of Lagrangian markers become saturated along the interface (i.e., each marker remains properly correlated with all its neighbors); (ii) The Lagrangian volume-weight is a relaxation factor to control how fast the velocity error decays to the ideal value of zero; (iii) The optimal choice of the Lagrangian volume-weight is the largest value permissible by a stability condition. A comprehensive convergence analysis with regard to the spatial and temporal resolution is presented for the velocity error and also for the shear-stress and surface pressure. In three simple canonical problems, it is analytically and numerically shown that the IBM results converge to the theoretical solutions obtained with precise imposition of no-slip and no-penetration boundary conditions. It is observed that it is not necessary to match the Lagrangian marker volume-weight to that of the local Eulerian cell volume and in fact this matching leads to lower than optimal computational efficiency. However, it is found that extremely high Eulerian grid resolution and small time step have to be used to obtain high precision simulation results. Especially, the time step should be inversely proportional to the particle Reynolds number for low Reynolds number flows. For high frequency oscillation problems, the grid size needs to be reduced by a factor of the square root of the frequency, and the time step to be reduced by a factor of the frequency. The theoretical findings here can be used to alleviate the technical difficulties in simulating non-spherical particles by not requiring the Lagrangian marker distribution to match the Eulerian grids and also in the implementation of IBM on non-uniform Eulerian grids. The present work also provides simple practical guidance on the choice of temporal and spatial resolution so as to control the simulation error a priori.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase behavior of continuous-space systems: A supervised machine learning approach

The phase behavior of complex fluids is a challenging problem for molecular simulations. Supervised machine learning (ML) methods have shown potential for identifying the phase boundaries of lattice models. In this work, we extend these ML methods to continuous-space systems. We propose a convolutional neural network model that utilizes grid-interpolated coordinates of molecules as input data of ML and optimizes the search for phase transitions with different filter sizes. We test the method for the phase diagram of two off-lattice models, namely, the Widom–Rowlinson model and a symmetric freely jointed polymer blend, for which results are available from standard molecular simulations techniques. The ML results show good agreement with results of previous simulation studies with the added advantage that there is no critical slowing down. We find that understanding intermediate structures near a phase transition and including them in the training set is important to obtain the phase boundary near the critical point. The method is quite general and easy to implement and could find wide application to study the phase behavior of complex fluids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗