Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error correction.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Correction for dynamic bias error in transmission measurements of void fraction

Dynamic bias errors occur in transmission measurements, such as X-ray, gamma, or neutron radiography or tomography. This is observed when the properties of the object are not stationary in time and its average properties are assessed. The nonlinear measurement response to changes in transmission within the time scale of the measurement implies a bias, which can be difficult to correct for. A typical example is the tomographic or radiographic mapping of void content in dynamic two-phase flow systems. In this work, the dynamic bias error is described and a method to make a first-order correction is derived. A prerequisite for this method is variance estimates of the system dynamics, which can be obtained using high-speed, time-resolved data acquisition. However, in the absence of such acquisition, a priori knowledge might be used to substitute the time resolved data. Using synthetic data, a void fraction measurement case study has been simulated to demonstrate the performance of the suggested method. The transmission length of the radiation in the object under study and the type of fluctuation of the void fraction have been varied. Significant decreases in the dynamic bias error were achieved to the expense of marginal decreases in precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Is ExacTrac x-ray system an alternative to CBCT for positioning patients with head and neck cancers?

Purpose: To evaluate the usefulness of a six-degrees-of freedom (6D) correction using ExacTrac robotics system in patients with head-and-neck (HN) cancer receiving radiation therapy.Methods: Local setup accuracy was analyzed for 12 patients undergoing intensity-modulated radiation therapy (IMRT). Patient position was imaged daily upon two different protocols, cone-beam computed tomography (CBCT), and ExacTrac (ET) images correction. Setup data from either approach were compared in terms of both residual errors after correction and punctual displacement of selected regions of interest (Mandible, C2, and C6 vertebral bodies).Results: On average, both protocols achieved reasonably low residual errors after initial correction. The observed differences in shift vectors between the two protocols showed that CBCT tends to weight more C2 and C6 at the expense of the mandible, while ET tends to average more differences among the different ROIs.Conclusions: CBCT, even without 6D correction capabilities, seems preferable to ET for better consistent alignment and the capability to see soft tissues. Therefore, in our experience, CBCT represents a benchmark for positioning head and neck cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recalculation of Soil Bulk Density Used in the Scorpius MCNP6 Model

The soil composition used in the Scorpius MCNP6.2 (Ref. 1) model was recently recalculated. Originally, it was “determined using the United States Geological Survey (USGS) Mercury Core Library and the Nevada National Security Site U.S. Geological Survey Databases (NNSS USGS) and Nevada National Security Site Petrographic, Geochemical, and Geophysical Database (NNSS PGG),” but the details had been lost. Reference 2 documents the updated soil composition determination. Reference 2 estimated the grain density of the soil instead of the bulk density. This report corrects that error. I am indebted to Garrett Euler (EES-17) for reading Ref. 2, pointing out its errors, and guiding me through the correct calculations. This report is organized as follows. For completeness, the composition calculations from Ref. 2 are repeated: Sec. II discusses the data that are reported in the PGG Access database, and Sec. III uses the data in the PGG Access database to compute the composition of the soil. Section IV estimates the bulk density of the soil. Section V evaluates the soil wall thickness in the Scorpius model. Section VI estimates the effect of the soil density change on previously calculated results. Section VII presents a summary and conclusions. Input files and output files are listed in appendices.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Digital correction of geometric and radiometric errors in ERTS data.

The sensor systems of the ERTS-A satellite are discussed and sources of geometric and radiometric errors in the received images are identified. Digital algorithms are presented for detection of reseau and ground control points, for rapid implementation of geometric corrections, and for radiometric correction of errors caused by shading, image motion, modulation transfer function, and quantum and systematic noise.

Bakis, R.↗

Radiometric correction of atmospheric path length fluctuations in interferometric experiments

To support very long baseline interferometric experiments, a system has been developed for estimating atmospheric water vapor path delay. The system consists of dual microwave radiometers, one operating at 20.7 GHz and the other at 31.4 GHz. The measured atmospheric brightness temperatures at these two frequencies yield the estimate of the precipitable water present in both vapor and droplets. To determine the accuracy of the system, a series of observations were undertaken, comparing the outputs of two water vapor radiometers with the phase variation observed with two connected elements of the very large array (VLA). The results show that: (1) water vapor fluctuations dominate the residual VLA phase and (2) the microwave radiometers can measure and correct these effects. The rms phase error after correction is typically 15 deg at a wavelength of 6 cm, corresponding to an uncertainty in the path delay of 0.25 cm. The residual uncertainty is consistent with the stability of the microwave radiometer but is still considerably larger than the stability of the VLA. The technique is less successful under conditions of heavy cloud.

Resch, G. M.↗

Software For Numerically Controlled Machining

APT (Automatically Programmable Tools) system represents an adaptation, with enhancements, of public-domain version of APT IV/SSX8 to DEC VAX-11/780 computer for use by Engineering Services Division of NASA Goddard Space Flight Center. Enhancements include super pocket feature, which allows concave polygon pockets. Recent modifications include expansion of sizes of arrays and buffers to accommodate larger part programs, insertion of user-friendly error messages, and correction of programming errors that affect POCKET command and some of sculptured-surface commands (notably SSURF and SCURV). Consists of four components: translator, execution complex, subroutine library, and CL editor. Written in FORTRAN 77.

Premo, D. A.↗

An Investigation of Differential Deposition for Figure Corrections in Full-Shell Grazing-Incidents X-Ray Optics

We are investigating differential deposition as a way of correcting small figure errors inside full-shell grazing-incidence x-ray optics. The optics in our study are fabricated using the electroformed-nickel-replication technique, and the figure errors arise from fabrication errors in the mandrel, from which the shells are replicated, as well as errors induced during the electroforming process. Combined, these give sub-micron-scale figure deviations which limit the angular resolution of the optics to approx. 10 arcsec. Sub-micron figure errors can be corrected by selectively depositing (physical vapor deposition) material inside the shell. The requirements for this filler material are that it must not degrade the ultra-smooth surface finish necessary for efficient x-ray reflection (approx. 5 A rms), and must not be highly stressed. In addition, a technique must be found to produce well controlled and defined beams within highly constrained geometries, as some of our mirror shells are less than 3 cm in diameter.

Gubarev, Mikhail V.↗

Chemical and Thermodynamic Properties at High Temperatures: A Symposium

This book contains the program and all available abstracts of the 90' invited and contributed papers to be presented at the TUPAC Symposium on Chemical and Thermodynamic Properties at High Temperatures. The Symposium will be held in conjunction with the XVIIIth IUPAC Congress, Montreal, August 6 - 12, 1961. It has been organized, by the Subcommissions on Condensed States and on Gaseous States of the Commission on High Temperatures and Refractories and by the Subcommission on Experimental Thermodynamics of the Commission on Chemical Thermodynamics, acting in conjunction with the Organizing Committee of the IUPAC Congress. All inquiries concerning participation In the Symposium should be directed to: Secretary, XVIIIth International Congress of Pure and Applied Chemistry, National Research Council, Ottawa, 'Canada. Owing to the limited time and facilities available for the preparation and printing of the book, it has not been possible to refer the proofs of the abstracts to the authors for checking. Furthermore, it has not been possible to subject the manuscripts to a very thorough editorial examination. Some obvious errors in the manuscripts have been corrected; other errors undoubtedly have been introduced. Figures have been redrawn only when such a step was essential for reproduction purposes. Sincere apologies are offered to authors and readers for any errors which remain; however, in the circumstances neither the IUPAC Commissions who organized the Symposium, nor the U. S. Government Agencies who assisted in the preparation of this book can accept responsibility for the errors.

Walker, Raymond F.↗

Search for Lepton Flavor Violation in Two Body Muon and Pion Decay at Rest

The ability of the Mu2e experiment to probe, or discover beyond the Standard Model physics in direct Charged Lepton Flavor Violation $\mu^+$ and $\pi^+$ decay modes is estimated. These direct modes are searched for simultaneously with proposed Mu2e detector validation runs, and are complementary to the Mu2e main search goal, an indirect search for $\mu^- \to e^-$ conversion at the sensitivity level of $\sim 10^{-17}$. The $\mu^+$ validation run will operate at 50% nominal magnetic field and reduced proton beam intensity to less than 1/100th nominal, in order to observe the e+ spectrum from $\mu^+$ decay, at and below the Michel edge Ee . 53 MeV. The $\pi^+$ validation run, based on measuring the mono-energetic e+ emission in the decay $\pi^+ \to e+\nu$, at 76% of nominal magnetic field and reduced beam intensity less than 1/5th nominal. Both of these runs can be used to fix the momentum scale for the Mu2e conversion search. In addition the muon validation dataset can be used to correct for systematic errors in the detector response by mapping the well known to O(\u03B13) corrected theoretical Michel spectrum, to the observed spectrum. One direct search is for two-body Charged Lepton Flavor Violation $\mu^+ \to e^+X$ decay, where $X$ is a light new physics particle. This allows Mu2e to explore well motivated models including axion like particles with flavor violating couplings and massive $Z^0$ bosons with more sensitivity then present astrophysical and laboratory constraints. In two weeks of data-taking, Mu2e can achieve direct mode 90% confidence level branching ratio limits of $10^{-7}$ over the mass range $20 \le m_X \le 50$ MeV, improving the current experimental limit at $10^{-5}$ by two orders of magnitude. In the mass range $m_X \le 20$ MeV, assuming systematic error corrections can be made by correcting the Monte Carlo mapping, the achievable search sensitivity is found to be $2.3\times 10^{-7}$ for $m_X =0$, an order of magnitude improvement over the current best limit at $2.6\times 10^{-6}$, when assuming $V+A$ or isotropic coupling. The $\pi^+$ validation run, allows searching for $\pi^+ \to e^+N$ decay, where $N$ is a heavy neutral lepton such as a heavy sterile neutrino, in the mass region $20 \le m_N \le 65$ MeV. A branching ratio limit at 90% confidence level of $3\times 10^{-8}$ can be achieved in two weeks, an improvement of the current search sensitivity limit by an order of magnitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluating software development by analysis of changes: The data from the software engineering laboratory

An effective data collection methodology for evaluating software development methodologies was applied to four different software development projects. Goals of the data collection included characterizing changes and errors, characterizing projects and programmers, identifying effective error detection and correction techniques, and investigating ripple effects. The data collected consisted of changes (including error corrections) made to the software after code was written and baselined, but before testing began. Data collection and validation were concurrent with software development. Changes reported were verified by interviews with programmers.

Source record↗

Residual position errors of lymph node surrogates in breast cancer adjuvant radiotherapy: Comparison of two arm fixation devices and the effect of arm position correction

Residual position errors of the lymph node (LN) surrogates and humeral head (HH) were determined for 2 different arm fixation devices in radiotherapy (RT) of breast cancer: a standard wrist-hold (WH) and a house-made rod-hold (RH). The effect of arm position correction (APC) based on setup images was also investigated. A total of 113 consecutive patients with early-stage breast cancer with LN irradiation were retrospectively analyzed (53 and 60 using the WH and RH, respectively). Residual position errors of the LN surrogates (Th1-2 and clavicle) and the HH were investigated to compare the 2 fixation devices. The position errors and setup margins were determined before and after the APC to investigate the efficacy of the APC in the treatment situation. A threshold of 5 mm was used for the residual errors of the clavicle and Th1-2 to perform the APC, and a threshold of 7 mm was used for the HH. The setup margins were calculated with the van Herk formula. Irradiated volumes of the HH were determined from RT treatment plans. With the WH and the RH, setup margins up to 8.1 and 6.7 mm should be used for the LN surrogates, and margins up to 4.6 and 3.6 mm should be used to spare the HH, respectively, without the APC. After the APC, the margins of the LN surrogates were equal to or less than 7.5/6.0 mm with the WH/RH, but margins up to 4.2/2.9 mm were required for the HH. The APC was needed at least once with both the devices for approximately 60% of the patients. With the RH, irradiated volume of the HH was approximately 2 times more than with the WH, without any dose constraints. Use of the RH together with the APC resulted in minimal residual position errors and setup margins for all the investigated bony landmarks. Based on the obtained results, we prefer the house-made RH. However, more attention should be given to minimize the irradiation of the HH with the RH than with the WH.

61 RADIATION PROTECTION AND DOSIMETRY↗

Correcting Turbulence-induced Errors in Fiber Positioning for the Dark Energy Spectroscopic Instrument

Highly multiplexed, robotic, fiber-fed spectroscopic surveys are observing tens of millions of stars and galaxies. For many systems, accurate positioning relies on imaging the fibers in the focal plane and feeding that information back to the robotic positioners to correct their positions. Inhomogeneities and turbulence in the air between the focal plane and the imaging camera can affect the measured positions of fibers, limiting the accuracy with which fibers can be placed on targets. For the Dark Energy Spectroscopic Instrument, we dramatically reduced the effect of turbulence on measurements of positioner locations in the focal plane by taking advantage of stationary positioners and the correlation function of the turbulence. We were able to reduce positioning errors from 7.3 to 3.5 μm, speeding the survey by 1.6% under typical conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPARC 3D Field Physics and Support of the Non-Axisymmetric Coil Assessment

Commonwealth Fusion Systems (CFS) is deploying SPARC, a net-energy tokamak, by 2025. A notable challenge facing all tokamak approaches to fusion energy production is maintaining a stable plasma and thereby steady energy production. “Disruptions” to plasma operation are often encountered in devices when they operate at high normalized pressure, high normalized density, or high normalized current. SPARC is unique in that it is expected to demonstrate Q>=2 in a plasma with low normalized pressure and density, but with a more modest current limit buffer sufficient to avoid disruptions. Due to both the high normalized current and high magnetic field of the SPARC design, it is expected to decrease its relative resilience to instabilities driven by non-axisymmetry in the externally applied magnetic field, termed ‘error fields’. To prevent error field driven instabilities, a primary line of defense is strict engineering tolerances in magnet fabrication and installation. A secondary line of defense is a purpose-built set of magnetic coils to correct these errors, termed error field correction coils (EFCCs). The overarching goals of this INFUSE project were to evaluate the effectiveness of the EFCCs in the SPARC design and provide guidance as to how to improve this effectiveness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination and correction of distortions and systematic errors in low-energy electron diffraction

We developed and implemented an algorithm to determine and correct systematic distortions in low-energy electron diffraction (LEED) images. The procedure is in principle independent of the design of the apparatus (spherical or planar phosphorescent screen vs. channeltron detector) and is therefore applicable to all device variants, known as conventional LEED, micro-channel plate LEED, and spot profile analysis LEED. The essential prerequisite is a calibration image of a sample with a well-known structure and a suitably high number of diffraction spots, e.g., a Si(111)-7×7 reconstructed surface. The algorithm provides a formalism which can be used to rectify all further measurements generated with the same device. In detail, one needs to distinguish between radial and asymmetric distortion. Additionally, it is necessary to know the primary energy of the electrons precisely to derive accurate lattice constants. Often, there will be a deviation between the true kinetic energy and the value set in the LEED control. Here, we introduce a method to determine this energy error more accurately than in previous studies. Following the correction of the systematic errors, a relative accuracy of better than 1% can be achieved for the determination of the lattice parameters of unknown samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sum-rule corrections: A route to error cancellations in correlation matrix renormalisation theory

Here, we recently proposed the correlation matrix renormalisation (CMR) theory to efficiently and accurately calculate ground state total energy of molecular systems, based on the Gutzwiller variational wavefunction (GWF) to treat the electronic correlation effects. To help reduce numerical complications and better adapt the CMR to infinite lattice systems, we need to further refine the way to minimise the error originated from the approximations in the theory. This conference proceeding reports our recent progress on this key issue, namely, we obtained a simple analytical functional form for the one-electron renormalisation factors, and introduced a novel sum-rule correction for a more accurate description of the intersite electron correlations. Benchmark calculations are performed on a set of molecules to show the reasonable accuracy of the method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correcting for particle counting bias error in turbulent flow

An ideal seeding device is proposed generating particles that exactly follow the flow out are still a major source of error, i.e., with a particle counting bias wherein the probability of measuring velocity is a function of velocity. The error in the measured mean can be as much as 25%. Many schemes have been put forward to correct for this error, but there is not universal agreement as to the acceptability of any one method. In particular it is sometimes difficult to know if the assumptions required in the analysis are fulfilled by any particular flow measurement system. To check various correction mechanisms in an ideal way and to gain some insight into how to correct with the fewest initial assumptions, a computer simulation is constructed to simulate laser anemometer measurements in a turbulent flow. That simulator and the results of its use are discussed.

Edwards, R. V.↗