At least 1,171 records · Page 65

Design Considerations for Compact High-Average Power Free-Electron Lasers/Masers at Terahertz Frequencies

Interest is increasing in high-power terahertz (THz) sources of radiation. The terminology is fluid, but researchers in the field typically refer to frequencies ranging from about 300 GHz to 10 THz as THz radiation. In this article, we present a description of design considerations for a compact, high-average power free-electron laser. At present, THz radiation is generated by a variety of mechanisms, including laser-based sources and electron-beam-based sources. Here, we provide a short description of current THz source technology to give background against which to compare the present concept; however, this should not be considered a comprehensive discussion of such technologies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compensating slice emittance growth in high brightness photoinjectors using sacrificial charge

Achieving maximum electron beam brightness in photoinjectors requires detailed control of the 3D bunch shape and precise tuning of the beam focusing. Even in state-of-the-art designs, slice emittance growth due to nonlinear space charge forces and partial nonlaminarity often remains non-negligible. In this work, we introduce a new means to linearize the transverse slice phase space: a sacrificial portion of the bunch’s own charge distribution, formed into a wavebroken shock front by highly nonlinear space charge forces within the gun, whose downstream purpose is to dynamically linearize the desired bunch core. We show that linearization of an appropriately prepared bunch can be achieved via strongly nonlaminar focusing of the sacrificial shock front, while the inner core focuses laminarly. This leads to a natural spatial separation of the two distributions: a dense core surrounded by a diffuse halo of sacrificial charge that can be collimated. Multiobjective genetic algorithm optimizations of the ultracompact x-ray free electron laser injector employ this concept, and we interpret it with an analytic model that agrees well with the simulations. In simulation, we demonstrate a final bunch charge of 100 pC, peak current ∼ 30 A, and a sacrificial charge of 150 pC (250 pC total emitted from cathode) with normalized emittance growth of < 20 nm rad due to space charge. This implies a maximum achievable brightness approximately an order of magnitude greater than existing free electron laser injector designs. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Active Q-Switched X-Ray Regenerative Amplifier Free-Electron Laser

Despite tremendous progress in x-ray free-electron laser (FEL) science over the last decade, future applications still demand fully coherent, stable x-rays that have not been demonstrated in existing X-ray FEL facilities. Here in this Letter, we describe an active Q-switched x-ray regenerative amplifier FEL scheme to produce fully coherent, high-brightness, hard x rays at a high-repetition rate. By using simple electron-beam phase space manipulation, we show this scheme is flexible in controlling the x-ray cavity quality factor Q and hence the output radiation. We report both theoretical and numerical studies on this scheme with a wide range of accelerator, x-ray cavity, and undulator parameters.

47 OTHER INSTRUMENTATION↗

Evaluating Brightness and Stability of Cathodoluminescence from Colloidal Semiconductor Nanocrystals

Cathodoluminescence offers promise as a technique for correlation of atomic structure with electronic structure at the level of individual nanoparticles or even defects, with the ability to analyze complex nanostructures at length-scales far below those typically available to optical spectroscopy. Unlike other forms of electron microscopy, cathodoluminescence offers direct insights into the electronic structure of the visualized sample. Despite reports more than 10 years ago of individual nanoparticle cathodoluminescence, effective cathodoluminescence collection from colloidal semiconductor materials is relatively rare and remains challenging due to the instability of materials under the conditions of electron beam irradiation. In this work, to clarify the roadblocks for cathodoluminescence analysis of colloidal nanocrystals, we attempt a comprehensive study of the cathodoluminescence properties of semiconductor quantum shells, which have a thin concentric CdSe shell surrounding CdS nanoparticles, then surrounded by a further concentric CdS shell. These same materials were recently demonstrated to show promising scintillation performance in radioluminescence measurements, including high brightness (up to 100 ph/keV) and excellent durability. Comparative quantum yield measurements are designed to assess the brightness of semiconductor nanocrystal films, which show that the quantum shells are much less bright under electron irradiation compared to X-ray photons. Instability of CL emission is assigned to charging effects on the samples—and not thermal effects—through a series of voltage, current, dwell time, and atmospheric pressure experiments.

cathodoluminescence↗

Evidence of Buried Junctions in CdSeTe Absorbers

The introduction of selenium band gap gradients has been shown to be a promising path for improving CdTe devices. Controlling maximum selenium concentration during deposition should allow for better device performance. In this work cross-section electron beam induced current (EBIC) maps were measured for CdSeTe/CdTe devices with as-grown selenium concentration between 0 and 20 percent. Measured EBIC profiles show high collection in the middle of the absorber layer, which differs from past EBIC studies of CdSe/CdTe devices. Increasing as-deposited selenium concentrations resulted in increased collection at this mid-absorber location. Combined with a 2-dimensional numerical model, these results suggest a buried homo-junction in the absorber layer of the device. This buried junction may be associated with a number of composition dependent parameters including electron affinity and p-dopability. Understanding this collection profile and its implications for device performance may be key in optimizing CdSeTe/CdTe devices.

CdSeTe↗

Expected sensitivity of the Light Dark Matter eXperiment to long-lived dark photons and axion-like particles

The Light Dark Matter eXperiment (LDMX) is an electron-beam fixed-target experiment primarily designed to achieve world-leading, model-independent sensitivity to sub-GeV dark matter particles. LDMX aims to identify dark sector particle production through the detection of events with substantial missing energy and momentum, a signature of invisible particles escaping detection. Beyond this primary objective, LDMX offers a complementary search strategy for long-lived, visibly decaying particles, such as dark photons and axion-like particles. We present the first detailed evaluation of the ability of LDMX to identify visibly decaying, long-lived particles that couple to electrons using a detailed simulation, based on the Geant 4-toolkit, that incorporates realistic detection efficiencies and background levels. We demonstrate that LDMX can achieve a sensitivity that is competitive with other experiments that are currently running. The models explored in this paper are distinct and complementary to those probed in the LDMX flagship missing-momentum analysis. Through searching for both invisible dark matter and visibly decaying long-lived signatures, LDMX will significantly advance the search for light dark matter and provide a broad exploration of the sub-GeV dark sector.[graphic not available: see fulltext]

Akesson, Torsten [Lund U.] (ORCID:0000000341415408↗

FLASH radiotherapy: ultra-high dose rates to spare healthy tissue

A recent addition to the treatment options in external beam therapy, so-called FLASH radiotherapy, shows remarkable healthy-tissue-sparing properties in a number of pre-clinical studies without impacting the overall treatment efficacy. Its potential in clinical applications is attracting a great deal of interest in the medical community. The use of ultra-high dose rates at extremely short irradiation times has been shown to significantly enhance the differential effects between normal and tumor tissue. This makes it possible to increase treatment doses without further harming the surrounding healthy tissue. While most studies to date have focused on the use of electron beams, X-ray and proton FLASH radiotherapy have also shown beneficial effects, although for these latter two the results still need to be independently confirmed. Additionally, the mechanisms underlying the biological effects remain to be elucidated. Very recently, the FLASH effect has been demonstrated in the first human patient, with promising results, supporting further clinical studies. In this work, we present an overview of the investigations into FLASH radiotherapy to date.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-efficiency transmission-mode diamond scintillator for quantitative characterization of X-ray beams

The luminance of a transmission mode X-ray scintillator diamond plate is dominated by induced defect centers having an excited state lifetime less than 10 msec, and in embodiments less than 1 msec, 100 usec, 10 used, 1 used, 100 nsec, or even 50 nsec, thereby providing enhanced X-ray luminance response and an X-ray flux dynamic range that is linear with X-ray flux on a log-log scale over at least three orders of magnitude. The diamond plate can be a single crystal having a dislocation density of less than 104 per square centimeter, and having surfaces that are ion milled instead of mechanically polished. The defect centers can be SiV centers induced by silicon doping during CVD diamond formation, and/or NV0 centers formed by nitrogen doping followed by applying electron beam irradiation of the diamond plate and annealing.

Antipov, Sergey↗

Influence of Light Atoms on Quantification of Atomic Column Positions in Distorted Perovskites with HAADF-STEM

Measurement of picometer-scale atomic displacements by aberration-corrected STEM has become invaluable in the study of crystalline materials, where it can elucidate ordering mechanisms and local heterogeneities. HAADF-STEM imaging, often used for such measurements due to its atomic number contrast, is generally considered insensitive to light atoms such as oxygen. Light atoms, however, still affect the propagation of the electron beam in the sample and, therefore, the collected signal. In this work, we demonstrate experimentally and through simulations that cation sites in distorted perovskites can appear to be displaced by several picometers from their true positions in shared cation-anion columns. The effect can be decreased through careful choice of sample thickness and beam voltage or can be entirely avoided if the experiment allows reorientation of the crystal along a more favorable zone axis. Therefore, it is crucial to consider the possible effects of light atoms and crystal symmetry and orientation when measuring atomic positions.

36 MATERIALS SCIENCE↗

Characterization of Self-Magnetic Pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories: 1) Diode Dynamics, DC Heating to extend Radiation Pulse

Radiographic diodes focus an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the RITS-6 Inductive Voltage Adder (IVA) driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode-cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analyzation of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below ~ few mm. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle-behavior of SMP shots is made to lend credence to the inference. There is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Method for making metal-carbon composites and compositions

A method for making covetic metal-carbon composites or compositions by electron beam melt heating under vacuum (pressure <10−3 Torr) is described herein. This fabrication method is advantageous, in that it provides oxygen-free covetic materials in a process that allows precise control of the composition of the covetic material to be produced. The method described herein also can be applied to produce multi-element-carbon composites within a metal or alloy matrix, including high melting temperature materials such as ceramic particles or prefabricated nano- or micro-structures, such as carbon nanotubes or graphene compounds. The covetic reaction between metal and carbon takes place under the influence of flowing electrons through the melted metal-carbon precursor. This process creates strong bonding between nanocarbon structure and the metal elements in the melt.

36 MATERIALS SCIENCE↗

High-Resolution Imaging of Cellulose Organization in Cell Walls by Field Emission Scanning Electron Microscopy

Field emission scanning electron microscopy (FESEM) is a powerful tool for analyzing surface structures of biological and nonbiological samples. However, when it is used to study fine structures of nanometer-sized microfibrils of epidermal cell walls, one often encounters tremendous challenges to acquire clear and undistorted images because of two major issues: (1) Preparation of samples suitable for high resolution imaging; due to the delicateness of some plant materials, such as onion epidermal cell walls, many things can happen during sample processing, which subsequently result in damaged samples or introduce artifacts. (2) Difficulties to acquire clear images of samples which are electron-beam sensitive and prone to charging artifacts at magnifications over 100,000×. In this chapter we described detailed procedures for sample preparation and conditions for high-resolution FESEM imaging of onion epidermal cell walls. Lastly, the methods can be readily adapted for other wall materials.

59 BASIC BIOLOGICAL SCIENCES↗

Studies of Quark Transport and Hadronization in Nuclei

In this project, we conducted the first measurement of di‑hadron azimuthal correlations in deep inelastic scattering (DIS) off nuclei using the CLAS detector at Jefferson Lab. Using 5 GeV electron‑beam data collected on deuterium, carbon, iron, and lead targets, we extracted di‑pion correlation functions over a broad kinematic range. The results show a monotonic broadening of the correlation peak with increasing nuclear mass, along with pronounced dependencies on the pions’ kinematics. Separately, we implemented an algorithm based on the Kalman filter that achieved the first complete alignment of the CLAS12 central tracking system. In parallel, we developed simulations, algorithms, and performance studies that informed the conceptual designs of the forward hadronic calorimeter Insert and the Zero Degree Calorimeter, both of which are now included in the ePIC detector baseline for the forthcoming Electron Ion Collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of self-magnetic pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories. I. Diode dynamics, DC heating to extend radiation pulse

Radiographic diodes focus on an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the six-cavity radiographic integrated test stand (RITS-6) inductive voltage adder driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode–cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analysis of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below approximately few millimeters. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle behavior of SMP shots is made to lend credence to the inference. We report there is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Light-Matter Interaction near the Schwinger Limit Using Tightly Focused Doppler-Boosted Lasers

Strong-field quantum electrodynamics (SF QED) is a burgeoning research topic dealing with electromagnetic fields comparable to the Schwinger field (≈1.32×10 18 V/m). While most past and proposed experiments rely on reaching this field in the rest frame of relativistic particles, the Schwinger limit could also be approached in the laboratory frame by focusing to its diffraction limit the light reflected by a plasma mirror irradiated by a multipetawatt laser. Here, we explore the interaction between such intense light and matter with particle-in-cell simulations. We find that the collision with a relativistic electron beam would enable the study of the nonperturbative regime of SF QED, while the interaction with a solid target leads to a profusion of SF QED effects that retroact on the interaction. In both cases, relativistic attosecond pair jets with high densities are formed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Charge-induced phase transition in encapsulated $\mathrm{HfTe_2}$ nanoribbons

Nanotube encapsulation is a powerful technique for coaxing solids into unconventional configurations. By synthesizing materials within the interior confines of hollow nanotubes, lower dimensional morphologies, such as one-dimensional chains or nanoribbons, are favored. We have used carbon nanotube encapsulation to realize ultranarrow, atomically precise HfTe 2 nanoribbons. A local, electron-beam-stimulated transition from the metallic 1T phase to the previously unreported semiconducting 1H phase is observed. Here, we study computationally how charging can drive the phase transition and the stability of the different atomic configurations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Intrinsic Li Distribution in Layered Transition-Metal Oxides Using Low-Dose Scanning Transmission Electron Microscopy and Spectroscopy

Understanding Li distribution in layered lithium transition-metal oxide (LiTMO) cathodes in Li-ion batteries has been a major challenge at the atomic scale and nanoscale. Li is extremely difficult to study by transmission electron microscopy (TEM) because the high-energy electrons impart significant energy and cause massive migration. Here, we directly map the intrinsic spatial distribution and bonding of Li in LiNiO 2 -layered cathode materials using low-dose and low-loss electron energy loss spectroscopy (EELS). EELS spectra of the Li–K edge are measured simultaneously with O–K and Ni–L, M 3,2 edges from layered, cation-mixed, and rock-salt phases and directly matched with atomic-resolution scanning TEM images to correlate the changes in peak intensities and positions to the stoichiometry changes with continual loss of Li and O. Changes in the Li content in the LiNiO 2 particles as a function of electron beam dose are studied by sequential Li spectroscopic mapping. We show that the “intrinsic” Li distribution can be observed using a total dose of less than ~1.5 × 10 8 e – nm –2 at an accelerating voltage of 80 kV. The method of nanoscale mapping of Li distribution introduced in this study is applicable to high-Ni LiTMO cathode materials (>89% of Ni) as well as LiNiO 2 . Further study on the extra peaks of the Li–K edge reveals that the peak at ~59 eV is from the Li ions intercalated in between NiO 2 layers barely interacting with each other with less Li K shell electrons pulled to the L shell electrons in NiO 2 . Furthermore, the results shown here provide improved low-loss TEM characterization approaches that can be used to understand the intrinsic fundamental behaviors in Li-ion batteries.

25 ENERGY STORAGE↗

Assessment of Blocking Contacts in Suppressing Polarization Effects in CsPbBr 3 Perovskite Detectors

The CsPbBr 3 perovskite has garnered significant attention as a room-temperature semiconductor for hard radiation detection due to straightforward synthesis, scalable crystal growth, low cost, and excellent energy resolution. However, despite these advantages, at ambient temperature, CsPbBr 3 devices may experience performance deterioration and irreversible failure due to “polarization” induced by electromigration of ions to electrical connections on the device. In this study, we tested several contact materials and their optimization deposition techniques to assess the stability of high-performance CsPbBr 3 γ-ray detectors. Metals, with low work functions (Ti, In, Sn, Sb, Pb, Bi, Al, Au, and TiC) and high-work-function (Au or Pt) contacts, were used to form different Schottky junctions using vacuum thermal evaporation, electron-beam evaporation, and sputtering methods. These detectors were tested in intermittent and continuous modes to assess their stability. Among the tested detectors, the Bi/CLB/Pt electrode configuration demonstrated superior stability, operating effectively for 11 months under periodic testing and 16 days under continuous testing. In contrast, other configurations functioned only for a few months under intermittent conditions. Upon incorporating a ~40-nm-thick TiC passivation layer on the anode side (Bi/TiC/CLB/Pt), the CLB device operated continuously for 36 days without degradation. In many cases, the failure mode of the devices was due to the degradation of the anode. Here, the chemical changes in the fresh and deteriorated anodes were characterized using scanning electron microscopy and energydispersive X-ray spectroscopy

CsPbBr3 perovskite↗