Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Efficiencies in the Environmental Restoration Operations at Sandia National Laboratories, New Mexico - 12198

The mission of the Environmental Restoration Operations at Sandia National Laboratories - New Mexico is to complete all necessary corrective actions at 268 legacy release soil sites and three groundwater Areas of Concern. Additional scope impacted the anticipated 2009 completion of corrective action at the remaining 32 soil sites and the three groundwater Areas of Concern. This additional scope is base-lined to require 10 years (2011-2020) at an estimated cost of $34 M to $39 M. Efficiencies been proposed to reduce the impact of this recently realized additional corrective action scope: (1) Perform activities concurrently when possible to help reduce the length of the overall schedule; (2) Implement a 'high-performance, one-pass' concept based on an early resolution of deficiencies in draft documents and attempt to avoid multi-submission cycles with long turnaround review times, and (3) Assess the appropriateness of progressing 'at risk' from groundwater characterization to groundwater remediation using existing data, conceptual models and potential remedies. The ongoing promotion and implementation of these ideas with the New Mexico Environment Department will produce scope and cost saving -- without any reduction in the protection of public health and the environment. DOE/SSO developed and presented to the NMED three areas where efficiencies in ER Operations may be realized. The NMED has not formally responded to these proposals, but in discussions with NMED in the fall of 2011 the NMED is conceptually supportive of these proposals. NMED cannot commit to an outcome (such as no NOD), but NMED is very willing to seek efficiencies that will reduce the overall scope, while achieving regulatory compliance and considering public input. The challenge of finding efficiencies to reduce the new schedule and cost has become even more of a necessity due to shrinking budgets. A prioritization of remaining activities has been discussed with the regulatory authority. Efficiencies in the ER Operations at SNL have been proposed to reduce the impact of recently realized regulatory delays and additional corrective action scope. The ongoing promotion and implementation of these ideas with the NMED will produce scope and cost saving, without any reduction in the protection of public health and the environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Instrument Efficiencies and ISO-7503 - 16525

The International Standard for the Evaluation of Surface Contamination provides guidance on evaluating surface contamination, and is used to document clearance of buildings, materials, and equipment. A key component of the guidance is the determination of instrument efficiency based on the 2-pi emission rate of a traceable radiation source. Many projects implement portions of this guidance or apply the guidance incorrectly. These errors generally result in an overestimate of the instrument efficiency, resulting in an underestimate of the activity being measured and overly optimistic estimates of detectability. A review of the recommendations for developing instrument efficiencies is provided, and the aspects of the guidance that are most often neglected are identified. The impact of failing to properly determine the instrument efficiency is demonstrated using experimental data. Data were collected using traceable alpha and beta radiation sources at multiple source-to-detector distances using gas-proportional and dual-phosphor detectors. The results of these measurements demonstrate the importance of proper implementation of the guidance for determining instrument efficiency and assist reviewers in identifying situations where the guidance was not properly implemented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pursuing Energy Efficiency as a Hedge against Carbon Regulatory Risks: Current Resource Planning Practices in the West

Uncertainty surrounding the nature and timing of future carbon regulations poses a fundamental and far-reaching financial risk for electric utilities and their ratepayers. Long-term resource planning provides a potential framework within which utilities can assess carbon regulatory risk and evaluate options for mitigating exposure to this risk through investments in energy efficiency and other low-carbon resources. In this paper, we examine current resource planning practices related to managing carbon regulatory risk, based on a comparative analysis of the most-recent long-term resource plans filed by fifteen major utilities in the Western U.S. First, we compare the assumptions and methods used by utilities to assess carbon regulatory risk and to evaluate energy efficiency as a risk mitigation option. Although most utilities have made important strides in beginning to address carbon regulatory risk within their resource plan, we also identify a number of opportunities for improvement and offer recommendations for resource planners and state regulators to consider. We also summarize the composition and carbon intensity of the preferred resource portfolios selected by the fifteen Western utilities, highlighting the contribution of energy efficiency and its impact on the carbon intensity of utilities' proposed resource strategies. Energy efficiency and renewables are the dominant low-carbon resources included in utilities' preferred portfolios. Across the fifteen utilities, energy efficiency constitutes anywhere from 6percent to almost 50percent of the preferred portfolio energy resources, and represents 22percent of all incremental resources in aggregate.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Collimation Optimizations, Capture Efficiency, and Primary-Beam Power Loss in the ILC Positron Source

The ILC positron beam generated from a thin Ti target has a wide energy spread and large transverse divergence. With the collection optics immediately downstream of the target and pre-acceleration to 125 MeV, the collected positron beam still has a long tail of positrons with low energies and large transverse divergence, which will be lost in the rest of the ILC positron source beamline. A collimation system is proposed and optimized for the case of a shielded target with quarter-wave transformation collection optics so that the power loss in the magnets and RF structures is effectively controlled within the acceptable level and in the damping ring (DR) within 640 W, assuming 3 x 10{sup 10} of the captured positrons per bunch in the DR. In this case, the capture efficiency and DR injection efficiency are 13% and 99.8%, respectively. The lower capture efficiency is expected to result in higher injection efficiency and therefore, a lower power loss in the DR. The capture efficiency for the cases of a shielded target with flux concentrator and 5-T immersed target with flux concentrator is 20% and 30%, respectively, with the collimation system.

43 PARTICLE ACCELERATORS↗

Pursuing Energy Efficiency as a Hedge against Carbon Regulatory Risks: Current Resource Planning Practices in the West

Uncertainty surrounding the nature and timing of future carbon regulations poses a fundamental and far-reaching financial risk for electric utilities and their ratepayers. Long-term resource planning provides a potential framework within which utilities can assess carbon regulatory risk and evaluate options for mitigating exposure to this risk through investments in energy efficiency and other low-carbon resources. In this paper, we examine current resource planning practices related to managing carbon regulatory risk, based on a comparative analysis of the most-recent long-term resource plans filed by fifteen major utilities in the Western U.S. First, we compare the assumptions and methods used by utilities to assess carbon regulatory risk and to evaluate energy efficiency as a risk mitigation option. Although most utilities have made important strides in beginning to address carbon regulatory risk within their resource plan, we also identify a number of opportunities for improvement and offer recommendations for resource planners and state regulators to consider. We also summarize the composition and carbon intensity of the preferred resource portfolios selected by the fifteen Western utilities, highlighting the contribution of energy efficiency and its impact on the carbon intensity of utilities' proposed resource strategies. Energy efficiency and renewables are the dominant low-carbon resources included in utilities' preferred portfolios. Across the fifteen utilities, energy efficiency constitutes anywhere from 6percent to almost 50percent of the preferred portfolio energy resources, and represents 22percent of all incremental resources in aggregate.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Successful Case Study of Small Business Energy Efficiency and Demand Response with Communicating Thermostats

This report documents a field study of 78 small commercial customers in the Sacramento Municipal Utility District service territory who volunteered for an integrated energy-efficiency/demand-response (EE-DR) program in the summer of 2008. The original objective for the pilot was to provide a better understanding of demand response issues in the small commercial sector. Early findings justified a focus on offering small businesses (1) help with the energy efficiency of their buildings in exchange for occasional load shed, and (2) a portfolio of options to meet the needs of a diverse customer sector. To meet these expressed needs, the research pilot provided on-site energy efficiency advice and offered participants several program options, including the choice of either a dynamic rate or monthly payment for air-conditioning setpoint control. Overall results show that pilot participants had energy savings of 20%, and the potential for an additional 14% to 20% load drop during a 100 F demand response event. In addition to the efficiency-related bill savings, participants on the dynamic rate saved an estimated 5% on their energy costs compared to the standard rate. About 80% of participants said that the program met or surpassed their expectations, and three-quarters said they would probably or definitely participate again without the $120 participation incentive. These results provide evidence that energy efficiency programs, dynamic rates and load control programs can be used concurrently and effectively in the small business sector, and that communicating thermostats are a reliable tool for providing air-conditioning load shed and enhancing the ability of customers on dynamic rates to respond to intermittent price events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Financial Impact of Energy Efficiency under a Federal Renewable Electricity Standard: Case Study of a Kansas"super-utility"

Local, state and federal policies that jointly promote the generation of electricity from renewable technologies and the pursuit of energy efficiency are expected to help mitigate the detrimental effects of global climate change and foster energy independence. We examine the financial impacts on various stakeholders from alternative compliance strategies with a Combined Efficiency and Renewable Electricity Standard (CERES) using a case study approach for utilities in Kansas. If only supply-side options are considered, our analysis suggests that a Kansas"super-utility" would prefer to build its own renewable energy resources, while ratepayers would favor a procurement strategy that relies on long-term renewable power purchase agreements. Introducing energy efficiency under varying levels as a CERES resource will, under our analysis, reduce ratepayer bills by ~;;$400M to ~;;$1.0B between 2009 and 2028, but commensurately erode shareholder returns by ~;;10 to ~;;100 basis points. If a business model for energy efficiency inclusive of both a lost fixed cost recovery mechanism and a shareholder incentive mechanism is implemented, our results illustrate how shareholder returns can be improved through the pursuit of energy efficiency, by at most ~;;20 basis points if certain conditions apply, while ratepayers continue to save between $10M and ~;;$840M over 20 years.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Global patterns and climate drivers of water-use efficiency in terrestrial ecosystems deduced from satellite-based datasets and carbon cycle models

Our aim is to investigate how ecosystem water-use efficiency (WUE) varies spatially under different climate conditions, and how spatial variations in WUE differ from those of transpiration-based water-use efficiency (WUE t ) and transpiration-based inherent water-use efficiency (IWUE t ). LocationGlobal terrestrial ecosystems. We investigated spatial patterns of WUE using two datasets of gross primary productivity (GPP) and evapotranspiration (ET) and four biosphere model estimates of GPP and ET. Spatial relationships between WUE and climate variables were further explored through regression analyses. Global WUE estimated by two satellite-based datasets is 1.9 ± 0.1 and 1.8 ± 0.6g C m -2 mm -1 lower than the simulations from four process-based models (2.0 ± 0.3g C m -2 mm -1 ) but comparable within the uncertainty of both approaches. In both satellite-based datasets and process models, precipitation is more strongly associated with spatial gradients of WUE for temperate and tropical regions, but temperature dominates north of 50 degrees N. WUE also increases with increasing solar radiation at high latitudes. The values of WUE from datasets and process-based models are systematically higher in wet regions (with higher GPP) than in dry regions. WUE t shows a lower precipitation sensitivity than WUE, which is contrary to leaf- and plant-level observations. IWUE t , the product of WUE t and water vapour deficit, is found to be rather conservative with spatially increasing precipitation, in agreement with leaf- and plant-level measurements. In conclusion, WUE, WUE t and IWUE t produce different spatial relationships with climate variables. In dry ecosystems, water losses from evaporation from bare soil, uncorrelated with productivity, tend to make WUE lower than in wetter regions. Yet canopy conductance is intrinsically efficient in those ecosystems and maintains a higher IWUEt. This suggests that the responses of each component flux of evapotranspiration should be analysed separately when investigating regional gradients in WUE, its temporal variability and its trends.

54 ENVIRONMENTAL SCIENCES↗

Energy Efficiency: What Has Research Delivered in the Last 40 Years?

This article presents a critical assessment of 40 years of research that may be brought under the umbrella of energy efficiency, spanning different aggregations and domains—from individual producing and consuming agents to economy-wide effects to the role of innovation to the influence of policy. After 40 years of research, energy efficiency initiatives are generally perceived as highly effective. Innovation has contributed to lowering energy technology costs and increasing energy productivity. Energy efficiency programs in many cases have reduced energy use per unit of economic output and have been associated with net improvements in welfare, emission reductions, or both. Rebound effects at the macro level still warrant careful policy attention, as they may be nontrivial. Complexity of energy efficiency dynamics calls for further methodological and empirical advances, multidisciplinary approaches, and granular data at the service level for research in this field to be of greatest societal benefit.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency Improvement and Cost Saving Opportunities for the U.S. Iron and Steel Industry An ENERGY STAR(R) Guide for Energy and Plant Managers

Energy is an important cost factor in the U.S iron and steel industry. Energy efficiency improvement is an important way to reduce these costs and to increase predictable earnings, especially in times of high energy price volatility. There are a variety of opportunities available at individual plants in the U.S. iron and steel industry to reduce energy consumption in a cost-effective manner. This Energy Guide discusses energy efficiency practices and energy-efficient technologies that can be implemented at the component, process, facility, and organizational levels. A discussion of the structure, production trends, energy consumption, and greenhouse gas emissions of the iron and steel industry is provided along with a description of the major process technologies used within the industry. Next, a wide variety of energy efficiency measures are described. Many measure descriptions include expected savings in energy and energy-related costs, based on case study data from real-world applications in the steel and related industries worldwide. Typical measure payback periods and references to further information in the technical literature are also provided, when available. The information in this Energy Guide is intended to help energy and plant managers in the U.S. iron and steel industry reduce energy consumption and greenhouse gas emissions in a cost-effective manner while maintaining the quality of products manufactured. Further research on the economics of all measures?and on their applicability to different production practices?is needed to assess their cost effectiveness at individual plants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Role of Appraisals in Energy Efficiency Financing

This research identifies barriers and challenges and current industry status including several key appraisal industry developments for identifying and valuing energy efficiency, critical obstacles to documenting and assessing the potential added value from energy efficiency improvements, current opportunities to support and standardize reporting on energy efficiency and to ensure propervaluation, and next steps towards enabling energy efficiency financing market transformation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Business Case for Energy Efficiency in Support of Climate Change Mitigation, Economic and Societal Benefits in China

This study seeks to provide policymakers and other stakeholders with actionable information towards a road map for reducing energy consumption cost-effectively. We focus on individual end use equipment types (hereafter referred to as appliance groups) that might be the subject of policies - such as labels, energy performance standards, and incentives - to affect market transformation in the short term, and on high-efficiency technology options that are available today. As the study title suggests, the high efficiency or Business Case scenario is constructed around a model of cost-effective efficiency improvement. Our analysis demonstrates that a significant reduction in energy consumption and emissions is achievable at net negative cost, that is, as a profitable investment for consumers. Net savings are calculated assuming no additional costs to energy consumption such as carbon taxes. Savings relative to the base case as calculated in this way is often referred to as 'economic savings potential'. Chinese energy demand has grown dramatically over the last few decades. While heavy industry still plays a dominant role in greenhouse gas emissions, demand from residential and commercial buildings has also seen rapid growth in percentage terms. In the residential sector this growth is driven by internal migration from the countryside to cities. Meanwhile, income in both urban and rural subsectors allows ownership of major appliances. While residences are still relatively small by U.S. or European standards, nearly all households own a refrigerator, a television and an air conditioner. In the future, ownership rates are not expected to grow as much as in other developing countries, because they are already close to saturation. However, the gradual turnover of equipment in the world's largest consumer market provides a huge opportunity for greenhouse gas mitigation. In addition to residences, commercial floor space has expanded rapidly in recent years, and construction continues at a rapid pace. Growth in this sector means that commercial lighting and HVAC will play an increasingly important role in energy demand in China. The outlook for efficiency improvement in China is encouraging, since the Chinese national and local governments have implemented significant policies to contain energy intensity and announced their intention to continue and accelerate these. In particular, the Chinese appliance standards program, first established in 1989, was significantly strengthened and modernized after the passage of the Energy Conservation Law of 1997. Since then, the program has expanded to encompass over 30 equipment types (including motor vehicles). The current study suggests that, in spite of these efforts, there is significant savings to be captured through wide adoption of technologies already available on the Chinese market. The approach of the study is to assess the impact of short-term actions on long-term impacts. 'Short-term' market transformation is assumed to occur by 2015, while 'long-term' energy demand reduction impacts are assessed in 2030. In the intervening years, most but not all of the equipment studied will turn over completely. Early in 2011, the Chinese government announced a plan to reduce carbon dioxide emissions intensity (per unit GDP) by 16% by 2015 as part of the 12th five year plan. These targets are consistent with longer term goals to reduce emissions intensity 40-45% relative to 2005 levels by 2020. The efforts of the 12th FYP focus on short-term gains to meet the four-year targets, and concentrate mainly in industry. Implementation of cost-effective technologies for all new equipment in the buildings sector thus is largely complementary to the 12th FYP goals, and would provide a mechanism to sustain intensity reductions in the medium and long term. The 15-year time frame is significant for many products, in the sense that delay of implementation postpones economic benefits and mitigation of emissions of carbon dioxide. Such delays would result in putting in place energy-wasting technologies, postponing improvement until the end of their service life, or potentially resulting in expensive investment either in additional energy supplies or in early replacement to achieve future energy or emissions reduction targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thinking Globally: How ISO 50001 - Energy Management can make industrial energy efficiency standard practice

Industry utilizes very complex systems, consisting of equipment and their human interface, which are organized to meet the production needs of the business. Effective and sustainable energy efficiency programs in an industrial setting require a systems approach to optimize the integrated whole while meeting primary business requirements. Companies that treat energy as a manageable resource and integrate their energy program into their management practices have an organizational context to continually seek opportunities for optimizing their energy use. The purpose of an energy management system standard is to provide guidance for industrial and commercial facilities to integrate energy efficiency into their management practices, including fine-tuning production processes and improving the energy efficiency of industrial systems. The International Organization for Standardization (ISO) has identified energy management as one of its top five priorities for standards development. The new ISO 50001 will establish an international framework for industrial, commercial, or institutional facilities, or entire companies, to manage their energy, including procurement and use. This standard is expected to achieve major, long-term increases in energy efficiency (20percent or more) in industrial, commercial, and institutional facilities and to reduce greenhouse gas (GHG) emissions worldwide.This paper describes the impetus for the international standard, its purpose, scope and significance, and development progress to date. A comparative overview of existing energy management standards is provided, as well as a discussion of capacity-building needs for skilled individuals to assist organizations in adopting the standard. Finally, opportunities and challenges are presented for implementing ISO 50001 in emerging economies and developing countries.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparison of Test Procedures and Energy Efficiency Criteria in Selected International Standards and Labeling Programs for Clothes Washers, Water Dispensers, Vending Machines and CFLs

Since the late 1970s, energy labeling programs and mandatory energy performance standards have been used in many different countries to improve the efficiency levels of major residential and commercial equipment. As more countries and regions launch programs covering a greater range of products that are traded worldwide, greater attention has been given to harmonizing the specific efficiency criteria in these programs and the test methods for measurements. For example, an international compact fluorescent light (CFL) harmonization initiative was launched in 2006 to focus on collaboration between Australia, China, Europe and North America. Given the long history of standards and labeling programs, most major energy-consuming residential appliances and commercial equipment are already covered under minimum energy performance standards (MEPS) and/or energy labels. For these products, such as clothes washers and CFLs, harmonization may still be possible when national MEPS or labeling thresholds are revised. Greater opportunity for harmonization exists in newer energy-consuming products that are not commonly regulated but are under consideration for new standards and labeling programs. This may include commercial products such as water dispensers and vending machines, which are only covered by MEPS or energy labels in a few countries or regions. As China continues to expand its appliance standards and labeling programs and revise existing standards and labels, it is important to learn from recent international experiences with efficiency criteria and test procedures for the same products. Specifically, various types of standards and labeling programs already exist in North America, Europe and throughout Asia for products in China's 2010 standards and labeling programs, namely clothes washers, water dispensers, vending machines and CFLs. This report thus examines similarities and critical differences in energy efficiency values, test procedure specifications and other technical performance requirements in existing international programs in order to shed light on where Chinese programs currently stands and considerations for their 2010 programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data Center Energy Efficiency

Private and public sector efforts are underway to reduce energy use in data centers and the Office of Management and Budget’s Data Center Optimization Initiative outlines the energy efficiency requirements and strategies for federal data centers. The Federal Energy Management Program (FEMP) helps federal agencies meet these requirements. FEMP sponsors the Center of Expertise for Energy Efficiency in Data Centers (CoE), which helps federal agencies and other organizations implement data center energy efficiency projects by supplying technical support, tools, best practices, analyses, and the introduction of technologies. The CoE, located at the Lawrence Berkeley National Lab, partners with key public and private stakeholders to further efficiency efforts

Center of Expertise for Energy Efficiency in Data ↗

Solar wind conditions leading to efficient radiation belt electron acceleration: A superposed epoch analysis

In this study by determining preferential solar wind conditions leading to efficient radiation belt electron acceleration is crucial for predicting radiation belt electron dynamics. Using Van Allen Probes electron observations (>1 MeV) from 2012 to 2015, we identify a number of efficient and inefficient acceleration events separately to perform a superposed epoch analysis of the corresponding solar wind parameters and geomagnetic indices. By directly comparing efficient and inefficient acceleration events, we clearly show that prolonged southward Bz, high solar wind speed, and low dynamic pressure are critical for electron acceleration to >1 MeV energies in the heart of the outer radiation belt. We also evaluate chorus wave evolution using the superposed epoch analysis for the identified efficient and inefficient acceleration events and find that chorus wave intensity is much stronger and lasts longer during efficient electron acceleration events, supporting the scenario that chorus waves play a key role in MeV electron acceleration.

58 GEOSCIENCES↗

Introducing Low-Cost Pyrazine Unit into Terpolymer Enables High-Performance Polymer Solar Cells with Efficiency of 18.23%

Recently, a random ternary copolymerization strategy has become a promising and efficient approach to develop high-performance polymer donors for polymer solar cells (PSCs). Here, in this study, a low-cost electron-withdrawing unit, 2,5-bis(4-(2-ethylhexyl)thiophen-2-yl)pyrazine (PZ-T), is incorporated into the polymer backbone of PM6 as the third component, and three D-A 1 -D-A 2 type terpolymers PMZ-10, PMZ-20, and PMZ-30 are synthesized by the random copolymerization strategy, with the PZ-T proportion of 10%, 20%, and 30%, respectively. The terpolymers exhibit downshifted highest occupied molecular orbital energy levels than PM6, which is beneficial for obtaining higher open-circuit voltage (V oc ) of the PSCs with the polymer as a donor. Importantly, the PSCs based on PMZ-10:Y6 demonstrate efficient exciton dissociation, higher and balanced electron/hole mobilities, desirable aggregation, and high power conversion efficiency of 18.23%, which is the highest efficiency among the terpolymer-based PSCs so far. The results indicate that the ternary copolymerization strategy with PZ-T as the second A-unit is an efficient approach to further improve the photovoltaic performance and reduce the synthetic cost of the D-A copolymer donors.

36 MATERIALS SCIENCE↗

Solution Processed Ternary Tin (II) Alloy as Hole–Transport Layer of Sn–Pb Perovskite Solar Cells for Enhanced Efficiency and Stability

Tin-lead (Sn-Pb) narrow bandgap (NBG) perovskites show great potential in both single-junction and all-perovskite tandem solar cells. Sn-Pb perovskite solar cells (PSCs) are still limited by low charge collection efficiency and poor stability. Here, we report a ternary Sn (II) alloy of SnOCl as the hole-transport material (HTM) with a work function of 4.95 eV for Sn-Pb PSCs. The solution processed SnOCl layer has a texture structure which not only reduces the optical loss of the devices but also changes grain growth of Sn-Pb perovskites and boosts the carrier diffusion length to 3.63 μm. The formation of small perovskite grains at the HTM/perovskite interface is suppressed. These result in an almost constant internal quantum efficiency of 96 ± 2% across the absorption spectrum of Sn-Pb perovskites. The SnOCl HTM significantly enhances the stability of Sn-Pb PSCs with 87% of its initial efficiency retained after 1-sun illumination for 1,200 h, and keep 85% efficiency under 85°C thermal stress for 1,500 h. Furthermore, the hybrid HTM further improve the stabilized efficiencies of single-function Sn-Pb PSCs and all-perovskite tandem solar cells to 23.2% and 25.9%, respectively. This discovery opens an avenue to the multi-component metal alloys as HTM in PSCs.

36 MATERIALS SCIENCE↗