Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data depth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

PylotDB - A Database Management, Graphing, and Analysis Tool Written in Python

PylotDB, written completely in Python, provides a user interface (UI) with which to interact with, analyze, graph data from, and manage open source databases such as MySQL. The UI mitigates the user having to know in-depth knowledge of the database application programming interface (API). PylotDB allows the user to generate various kinds of plots from user-selected data; generate statistical information on text as well as numerical fields; backup and restore databases; compare database tables across different databases as well as across different servers; extract information from any field to create new fields; generate, edit, and delete databases, tables, and fields; generate or read into a table CSV data; and similar operations. Since much of the database information is brought under control of the Python computer language, PylotDB is not intended for huge databases for which MySQL and Oracle, for example, are better suited. PylotDB is better suited for smaller databases that might be typically needed in a small research group situation. PylotDB can also be used as a learning tool for database applications in general.

Barnette, DanielW.↗

SEVEN-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE (WMAP ) OBSERVATIONS: POWER SPECTRA AND WMAP-DERIVED PARAMETERS

The WMAP mission has produced sky maps from seven years of observations at L2. We present the angular power spectra derived from the seven-year maps and discuss the cosmological conclusions that can be inferred from WMAP data alone. With the seven-year data, the temperature (TT) spectrum measurement has a signal-to-noise ratio per multipole that exceeds unity for l < 919; and in band powers of width {Delta}l = 10, the signal-to-noise ratio exceeds unity up to l = 1060. The third acoustic peak in the TT spectrum is now well measured by WMAP. In the context of a flat {Lambda}CDM model, this improvement allows us to place tighter constraints on the matter density from WMAP data alone, {Omega}{sub m} h {sup 2} = 0.1334{sup +0.0056}{sub -0.0055}, and on the epoch of matter-radiation equality, z{sub eq} = 3196{sup +134}{sub -133}. The temperature-polarization (TE) spectrum is detected in the seven-year data with a significance of 20{sigma}, compared to 13{sigma} with the five-year data. We now detect the second dip in the TE spectrum near l {approx} 450 with high confidence. The TB and EB spectra remain consistent with zero, thus demonstrating low systematic errors and foreground residuals in the data. The low-l EE spectrum, a measure of the optical depth due to reionization, is detected at 5.5{sigma} significance when averaged over l = 2-7: l(l + 1)C {sup EE}{sub l}/(2{pi}) = 0.074{sup +0.034}{sub -0.025} {mu}K{sup 2} (68% CL). We now detect the high-l, 24 {<=} l {<=} 800, EE spectrum at over 8{sigma}. The BB spectrum, an important probe of gravitational waves from inflation, remains consistent with zero; when averaged over l = 2-7, l(l + 1)C {sup BB}{sub l}/(2{pi}) < 0.055 {mu}K{sup 2} (95% CL). The upper limit on tensor modes from polarization data alone is a factor of two lower with the seven-year data than it was using the five-year data. The data remain consistent with the simple {Lambda}CDM model: the best-fit TT spectrum has an effective {chi}{sup 2} of 1227 for 1170 degrees of freedom, with a probability to exceed of 9.6%. The allowable volume in the six-dimensional space of {Lambda}CDM parameters has been reduced by a factor of 1.5 relative to the five-year volume, while the {Lambda}CDM model that allows for tensor modes and a running scalar spectral index has a factor of three lower volume when fit to the seven-year data. We test the parameter recovery process for bias and find that the scalar spectral index, n{sub s} , is biased high, but only by 0.09{sigma}, while the remaining parameters are biased by <0.15{sigma}. The improvement in the third peak measurement leads to tighter lower limits from WMAP on the number of relativistic degrees of freedom (e.g., neutrinos) in the early universe: N{sub eff}>2.7(95%CL). Also, using WMAP data alone, the primordial helium mass fraction is found to be Y{sub He} = 0.28{sup +0.14}{sub -0.15}, and with data from higher-resolution cosmic microwave background experiments included, we now establish the existence of pre-stellar helium at >3{sigma}. These new WMAP measurements provide important tests of big bang cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

Replacement correction factors for cylindrical ion chambers in electron beams

Purpose: In the TG-21 dosimetry protocol, for cylindrical chambers in electron beams the replacement correction factor P{sub repl} (or the product p{sub dis}p{sub cav} in the IAEA's notation), was conceptually separated into two components: the gradient correction (P{sub gr}) accounting for the effective point of measurement and the fluence correction (P{sub fl}) dealing with the change in the electron fluence spectrum. At the depth of maximum dose (d{sub max}), P{sub gr} is taken as 1. There are experimental data available at d{sub max} for the values of P{sub fl} (or P{sub repl}). In the TG-51 dosimetry protocol, the calibration is at the reference depth d{sub ref}=0.6R{sub 50}-0.1 (cm) where P{sub gr} is required for cylindrical chambers and P{sub fl} is unknown and so the measured values at d{sub max} are used with the corresponding mean electron energy at d{sub ref}. Monte Carlo simulations are employed in this study to investigate the replacement correction factors for cylindrical chambers in electron beams. Methods: Using previously established Monte Carlo calculation methods, the values of P{sub repl} and P{sub fl} are calculated with high statistical precision (<0.1%) for cylindrical cavities of a variety of diameters and lengths in a water phantom irradiated by various electron beams. The values of P{sub gr} as defined in the TG-51 dosimetry protocol are also calculated. Results: The calculated values of the fluence correction factors P{sub fl} are in good agreement with the measured values when the wall correction factors are taken into account for the plane-parallel chambers used in the measurements. An empirical formula for P{sub fl} for cylindrical chambers at d{sub ref} in electron beams is derived as a function of the chamber radius and the beam quality specifier R{sub 50}. Conclusions: The mean electron energy at depth is a good beam quality specifier for P{sub fl}. Thus TG-51's adoption of P{sub fl} at d{sub max} with the same mean electron energy for use at d{sub ref} is proven to be accurate. The values of P{sub gr} for a Farmer-type chamber as defined in the TG-51 dosimetry protocol may be wrong by 0.3% for high-energy electron beams and by more than 1% for low-energy electron beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cloud Shortwave Optical Properties

The data set consists of calibrated zenith shortwave spectral radiances (400-950 nm and 940-1665 nm) and cloud optical depth (COD) retrievals every 2 seconds. The field of view is 0.5 degree. Retrievals of cloud droplet effective radius and thermodynamic phase are currently experimental and done offline. Effective radius and phase are not in this data set.

54 ENVIRONMENTAL SCIENCES↗

Selected micrometeorological and soil data from the Manaus ZF2 K34 eddy covariance tower for the 2015/16 El Niño event

The K34 tower site (2.609 S, 60.209 W, 130 masl), located within the Tropical Silviculture Experimental Station (EEST, also known as ZF2) research station, in an area of undisturbed tropical forest (Araújo et al. 2002). It features long term measurements using micrometeorological, eddy covariance, and soil instrumentation, among others. This dataset covers January 2012 to December 2017, and includes air temperature (TA, ℃) and air relative humidity (RH, %), measured with thermohygrometers (HC2S3, Campbell Scientific, Logan, UT, USA) deployed above the canopy at the top of the tower (at 51.1 m height), and net radiation (NETRAD, W m-2) using an NR-LITE sensor (Kipp & Zonen, Delft, Netherlands), also at the top of the tower (at 35.0 m above the canopy). The soil moisture data included here is from a soil profile located approximately 12 m from the tower, and covers the period between February 2015 and September 2016. Volumetric soil water content (SWC, m3 m-3) measurements used Water Content Reflectometers (CS655 Campbell Scientific, Logan, UT, USA) at six depths: 10 cm, 20 cm, 30 cm, 40 cm, 60 cm, and 100 cm. Data are included in .csv files, and the text file ZF2-K34_Tower_headers.txt provides descriptions of data file headers.

54 ENVIRONMENTAL SCIENCES↗

FREDA: A Web Application for the Processing, Analysis, and Visualization of Fourier‐Transform Mass Spectrometry Data

The high-resolution measurement capability of Fourier-transform mass spectrometry (FT-MS) has made it a necessity for exploring the molecular composition of complex organic mixtures, like soil, plant, aquatic, and petroleum samples. This demand has driven a need for informatics tools to explore and analyze FT-MS data in a robust and reproducible manner. FREDA is an interactive web application developed to enable spectrometrists to format, process, and explore their FT-MS data without the need for statistical programming expertise. FREDA was built to explore outputs from a molecular identification tool, like CoreMS, and provide a suite of methods to filter data, compute chemical properties of peaks, statistically compare samples and groups of samples, conduct exploratory data analysis, and download the results with a report detailing all steps conducted. To demonstrate the utility of FREDA, an example analysis was conducted using FT-MS data from a soil microbiology study of samples collected in two different soil depths at the Sphagnum bog forest north of Grand Rapids, Minnesota. Differences between the two depths are observed using Kendrick, Gibbs free energy, and van Krevelen plots. G-tests are used to quantify a significant difference between the groups. All analyses and plotting are conducted using only the FREDA application. FREDA is an open-source and readily available web application that allows users to explore and make statistically valid conclusions about their FT-MS data. The application is available online (https://map.emsl.pnnl.gov/app/freda) with a tutorial web series (https://youtu.be/k5HLE2kNSBY?si=yB6sGoyvzxrFf5MP) and freely accessible code on Github (https://github.com/EMSL-Computing/FREDA).

47 OTHER INSTRUMENTATION↗

Monitoring spatiotemporal evolution of fractures during hydraulic stimulations at the first EGS collab testbed using anisotropic elastic-waveform inversion

The EGS Collab project acquired continuous active-source seismic monitoring (CASSM) data before, during, and after hydraulic stimulations at the first testbed at the depth of 4850 ft (1478 m) at the Sanford Underground Research Facility in Lead, South Dakota, for monitoring fracture creation and evolution. CASSM acquisition was conducted using 24 hydrophones, 18 accelerometers, and 17 piezoelectric sources within four fracture-parallel wells and two orthogonal wells. 3D anisotropic traveltime tomography and anisotropic elastic-waveform inversion of the campaign cross-borehole seismic data show that the rock within the stimulation region is a heterogeneous horizontal transverse isotropic medium. Here we use these inversion results as the initial models and apply 3D anisotropic first-arrival traveltime tomography and 3D anisotropic elastic-waveform inversion to the CASSM data acquired after each stimulation in May, 2018 and December, 2018. We observe the spatiotemporal evolution of seismic velocities and anisotropic parameters caused by hydraulic fracture stimulations, showing the regions of rock alternation caused by hydraulic fracture stimulation.

15 GEOTHERMAL ENERGY↗

MO-F-16A-01: Implementation of MPPG TPS Verification Tests On Various Accelerators

Purpose: To demonstrate the implementation of the Medical Physics Practice Guideline (MPPG) for dose calculation and beam parameters verification of treatment planning systems (TPS). Methods: We implemented the draft TPS MPPG for three linacs: Varian Trilogy, TomoHDA and Elekta Infinity. Static and modulated test plans were created. The static fields are different than used in commissioning. Data was collected using ion chambers and diodes in a scanning water tank, Delta4 phantom and a custom phantom. MatLab and Microsoft Excel were used to create analysis tools to compare reference DICOM dose with scan data. This custom code allowed for the interpolation, registration and gamma analysis of arbitrary dose profiles. It will be provided as open source code. IMRT fields were validated with Delta4 registration and comparison tools. The time for each task was recorded. Results: The tests confirmed the strengths, and revealed some limitations, of our TPS. The agreement between calculated and measured dose was reported for all beams. For static fields, percent depth dose and profiles were analyzed with criteria in the draft MPPG. The results reveal areas of slight mismatch with the model (MLC leaf penumbra, buildup region.) For TomoTherapy, the IMRT plan 2%/2 mm gamma analysis revealed poorest agreement in the low dose regions. For one static test plan for all 10MV Trilogy photon beams, the plan generation, scan queue creation, data collection, data analysis and report took 2 hours, excluding tank setup. Conclusions: We have demonstrated the implementation feasibility of the TPS MPPG. This exercise generated an open source tool for dose comparisons between scan data and DICOM dose data. An easily reproducible and efficient infrastructure with streamlined data collection was created for repeatable robust testing of the TPS. The tests revealed minor discrepancies in our models and areas for improvement that are being investigated.

07 ISOTOPE AND RADIATION SOURCES↗

Groundwater elevation data for monitoring wells within the East and Taylor River basins, Colorado (USA)

This dataset is comprised of temporal variations in groundwater elevation data for the 24 monitoring wells located throughout the East River watershed. Seasonal to annual variations in groundwater elevations are a critical property of mountainous watersheds needed to understand both hydrological and below ground biogeochemical processes. Such data serve as a critical constraint for numerical models describing coupled groundwater-surface water behavior within the watershed. Additionally, the offset between the maximum and minimum groundwater elevations defines the extent of the bedrock weathering zone, with annual excursions in the groundwater hydrographic (i.e., the rising and falling hydrographic limbs) imposing primary controls on bedrock saturation state and redox conditions that govern biogeochemical reactions impacting nitrogen, carbon, and metals cycling. Manufacturer-specific software is used to download pressure data from each transducer, with broadly available spreadsheet software (e.g. Microsoft Excel) used to convert temporal variations in water pressure to elevations in units of meters above mean sea level. As additional monitoring wells are installed within the East River watershed and new groundwater monitoring wells are installed in the Taylor River watershed, temporal groundwater elevation data will be included as a part of this master dataset. Details regarding the metadata associated with each monitoring well location, including well depths, screened intervals, well location coordinates, and bedrock type, are included, as is a standard operating procedure for generating groundwater elevation data from water pressure values recorded by the pressure transducers. This dataset includes: (1) a zip file (East_River_Watershed_Compiled_Groundwater_Elevation_Data_Plots.zip), containing (a) PNG of groundwater hydrographs, (b) a CSV file with groundwater elevation data, and (c) CSV file containing metadata organized by location; (2) an Excel file (East_River_Watershed_Compiled_Groundwater_Elevation_Data_Plots.xlsx) with the groundwater elevation data, groundwater hydrographs, and metadata organized by location; (3) a Word file (Groundwater_elevation_data_protocols.docx) and a PDF file version (Groundwater_elevation_data_protocols.pdf) containing field protocols and methods; (4) a location metadata (locations.csv) file; (5) a file level metadata (flmd.csv); and (6) data dictionary (dd.csv) file.This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗

Characterization of unconventional electron fields for the treatment of mycosis fungoides using the total skin irradiation technique

Mycosis fungoides is a cutaneous lymphoma that accounts for 2–3% of all lymphomas. Several clinical studies have demonstrated the effectiveness of TSEBT (Total Skin Electron Beam Therapy) in patients with mycosis fungoides. It is important to develop this technique and make it available to a larger number of patients in Mexico. Because large fields for electron TSEBT are required in order to cover the entire body of the patient, beam characterization at conventional treatment distances is not sufficient and a calibration distance of 500cm or higher is required. Materials and methods: Calibration of radiochromic Gafchromic® EBT2 film (RCF) for electrons was performed in a solid water phantom (Scanditronix Wellhöfer) at a depth of 1.4cm and a Source Axis Distance (SAD) of 100cm. A polynomial fit was applied to the calibration curve, in order to obtain the equation relating dose response with optical density. The spatial distribution is obtained in terms of percentage of the dose, placing 3×3cm samples of RCF on the acrylic screen, which is placed in front of the patient in order to obtain maximum absorbed dose on the skin, covering an area of 200×100cm{sup 2}. The Percentage Depth Dose (PDD) curve was obtained placing RCF samples at depths of 0, 1, 1.2, 1.4, 1.5, 2, 3, 4, 5, 6, 7, 8 and 9cm in the solid water phantom, irradiated with an ELEKTA SINERGY Linear Accelerator electron beam, with an energy of 6 MeV, at a Source Skin Distance (SSD) of 500cm, with 1000MU = 100Gy, with a cone of 40×40cm and gantry angle of 90°. The RCFs were scanned on a flatbed scanner (EPSON EXPRESSION 10000 XL) and the images were processed with the ImageJ program using a region of interest (ROI) of 1×1cm{sup 2}. Results: The relative spatial dose distribution and the percentage depth dose for a SSD of 500±0.5cm, over an area of 200×100cm{sup 2} was obtained, resulting to an effective maximum dose depth (Z{sub ref}) for electrons of 1.4±0.05cm. Using the same experimental data, horizontal and vertical beam profiles were also graphed, showing a horizontal symmetry of ±035%, horizontal flatness of ±3.62%, vertical symmetry of ±2.1% and vertical flatness of ±14.2%. Conclusions: The electron beam was characterized and the data obtained were useful to determine the spatial dose distribution to a SSD of 500±0.5cm, in an area of 200×100cm{sup 2}. Dose profiles were obtained both horizontally and vertically, thus allowing to assess electron beam symmetry and flatness. PDD analysis up to a depth of 9±0.05cm, has made possible to establish the depth of electron penetration, assuring an only skin irradiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Changuinola peat soil characteristics and gas emission raw data October 2019

This dataset comprises radiocarbon and geochemical measurements from peat and porewater samples collected across various depths at a site in Bocas del Toro, Panama. The study focuses on carbon cycling dynamics in tropical peatlands by examining carbon isotopic signatures (¹⁴C and ¹³C) and elemental compositions of bulk peat, dissolved organic carbon (DOC), carbon dioxide (CO₂), and methane (CH₄). Key parameters include radiocarbon ages and isotopic ratios (δ¹³C) of bulk peat, concentrations of carbon (%C) and nitrogen (%N), and radiocarbon content of porewater gases and dissolved organic carbon (DOC). The data provide insights into the vertical and spatial distribution of carbon sources and possible preservation and decomposition processes within tropical peat profiles, offering critical information for understanding carbon storage and greenhouse gas emissions in these ecosystems.This dataset is comprised of one main data folder containing (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) carbon isotopic signatures (¹⁴C and ¹³C); (5) concentrations of carbon (%C) and nitrogen (%N); (6) radiocarbon content of porewater carbon dioxide (CO₂), and methane (CH₄) ; (7) porewater DOC; (8) bulk peat sampling protocol; (9) porewater sampling protocol; (10) porewater gas collection methods; and (11) gas extraction methods. All files are in .csv format and can be opened with any software that supports this file types.

54 ENVIRONMENTAL SCIENCES↗

The OME Framework for genome-scale systems biology

The life sciences are undergoing continuous and accelerating integration with computational and engineering sciences. The biology that many in the field have been trained on may be hardly recognizable in ten to twenty years. One of the major drivers for this transformation is the blistering pace of advancements in DNA sequencing and synthesis. These advances have resulted in unprecedented amounts of new data, information, and knowledge. Many software tools have been developed to deal with aspects of this transformation and each is sorely needed. However, few of these tools have been forced to deal with the full complexity of genome-scale models along with high throughput genome-scale data. This particular situation represents a unique challenge, as it is simultaneously necessary to deal with the vast breadth of genome-scale models and the dizzying depth of high-throughput datasets. It has been observed time and again that as the pace of data generation continues to accelerate, the pace of analysis significantly lags behind. It is also evident that, given the plethora of databases and software efforts, it is still a significant challenge to work with genome-scale metabolic models, let alone next-generation whole cell models. We work at the forefront of model creation and systems scale data generation. The OME Framework was borne out of a practical need to enable genome-scale modeling and data analysis under a unified framework to drive the next generation of genome-scale biological models. Here we present the OME Framework. It exists as a set of Python classes. However, we want to emphasize the importance of the underlying design as an addition to the discussions on specifications of a digital cell. A great deal of work and valuable progress has been made by a number of communities towards interchange formats and implementations designed to achieve similar goals. While many software tools exist for handling genome-scale metabolic models or for genome-scale data analysis, no implementations exist that explicitly handle data and models concurrently. The OME Framework structures data in a connected loop with models and the components those models are composed of. This results in the first full, practical implementation of a framework that can enable genome-scale design-build-test. Over the coming years many more software packages will be developed and tools will necessarily change. However, we hope that the underlying designs shared here can help to inform the design of future software.

59 BASIC BIOLOGICAL SCIENCES↗

THE INFRARED ARRAY CAMERA DARK FIELD: FAR-INFRARED TO X-RAY DATA

We present 20 band photometry from the far-IR to X-ray in the Spitzer Infrared Array Camera (IRAC) dark field. The bias for the near-IR camera on Spitzer is calibrated by observing a {approx}20' diameter 'dark' field near the north ecliptic pole roughly every two-to-three weeks throughout the mission duration of Spitzer. The field is unique for its extreme depth, low background, high quality imaging, time-series information, and accompanying photometry including data taken with Akari, Palomar, MMT, KPNO, Hubble, and Chandra. This serendipitous survey contains the deepest mid-IR data taken to date. This data set is well suited for studies of intermediate-redshift galaxy clusters, high-redshift galaxies, the first generation of stars, and the lowest mass brown dwarfs, among others. This paper provides a summary of the data characteristics and catalog generation from all bands collected to date as well as a discussion of photometric redshifts and initial and expected science results and goals. To illustrate the scientific potential of this unique data set, we also present here IRAC color-color diagrams.

79 ASTRONOMY AND ASTROPHYSICS↗

Basic Data Report for Well Plugging and Abandonment Activities for Fiscal Year 2009

The Waste Isolation Pilot Plant (WIPP) facility is a U.S. Department of Energy (DOE) facility for disposal of transuranic mixed waste under a permit issued by the New Mexico Environment Department. The WIPP facility is 26 miles southeast of Carlsbad, New Mexico, in eastern Eddy County. Disposal panels are mined in the Permian Salado Formation at a depth of 2,150 feet below ground surface (bgs). Field activities for this Basic Data Report were initiated in June 2009, and concluded in July 2009. The FY 2009 program included the plugging and abandonment (P&A) of two monitoring wells, which permanently removed them from the monitoring network. This Basic Data Report presents the summary of procedures followed for each well completion as documented by the Subcontract Technical Representative (STR).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A mechanistic model for depth-dependent hardness of ion irradiated metals

A mechanistic model was developed for modeling the depth-dependent hardness in ion irradiated metallic materials. The model is capable of capturing the indentation size effect, ion irradiation induced damage gradient effect, and effect of unirradiated region acting as a soft substrate. A procedure was developed and described in detail to parametrize the model based on experimentally obtained hardness vs. indentation depth curves. Very good agreement was observed between our model predictions and experimental data of several different stainless steels subjected to various ion irradiation conditions. Additionally, two hardening mechanisms are revealed in the new model. One is the well-known indentation size effect arising from the creation of geometrically necessary dislocations as the indenter pierces into the materials. The other is the irradiation hardening due to the presence of irradiation-induced defects. As a function of indentation depth h, the hardening due to indentation size effect is described by $\bar{h}^*/h$, while the hardening due to irradiation first follows a power law form $ph^n$, then changes to Z/h - Q/h 3 , where $\bar{h}^*$, P, n, Z and Q > 0 are constants. This transition occurs at the indentation depth when the plastic zone reaches the end of the irradiated layer.

36 MATERIALS SCIENCE↗

Nontrivial Nature and Penetration Depth of Topological Surface States in SmB 6 Thin Films

The nontrivial feature and penetration depth of the topological surface states (TSS) in SmB 6 were studied via spin pumping. The experiments used SmB 6 thin films grown on the bulk magnetic insulator Y 3 Fe 5 O 12 (YIG). Upon the excitation of magnetization precession in the YIG, a spin current is generated in the SmB 6 that produces, via spin--orbit coupling, a lateral electrical voltage in the film. This spin-pumping voltage signal becomes considerably stronger as the temperature decreases from 150 to 10 K, and such an enhancement most likely originates from the spin-momentum locking of the TSS and may thereby serve as evidence for the nontrivial nature of the TSS. The voltage data also show a unique film thickness dependence that suggests a TSS depth of ~32 nm. Finally, the spin--pumping results arc supported by transport measurements and analyses using a tight binding model.

36 MATERIALS SCIENCE↗

Novel Histogram Based Unsupervised Classification Technique to Determine Natural Classes From Biophysically Relevant Fit Parameters to Hyperspectral Data

Hyperspectral image analysis has benefited from an array of methods that take advantage of the increased spectral depth compared to multispectral sensors; however, the focus of these developments has been on supervised classification methods. Lack of a priori knowledge regarding land cover characteristics can make unsupervised classification methods preferable under certain circumstances. An unsupervised classification technique is presented in this paper that utilizes physically relevant basis functions to model the reflectance spectra. These fit parameters used to generate the basis functions allow clustering based on spectral characteristics rather than spectral channels and provide both noise and data reduction. Histogram splitting of the fit parameters is then used as a means of producing an unsupervised classification. Unlike current unsupervised classification techniques that rely primarily on Euclidian distance measures to determine similarity, the unsupervised classification technique uses the natural splitting of the fit parameters associated with the basis functions creating clusters that are similar in terms of physical parameters. The data set used in this work utilizes the publicly available data collected at Indian Pines, Indiana. This data set provides reference data allowing for comparisons of the efficacy of different unsupervised data analysis. The unsupervised histogram splitting technique presented in this paper is shown to be better than the standard unsupervised ISODATA clustering technique with an overall accuracy of 34.3/19.0% before merging and 40.9/39.2% after merging. Finally, this improvement is also seen as an improvement of kappa before/after merging of 24.8/30.5 for the histogram splitting technique compared to 15.8/28.5 for ISODATA.

58 GEOSCIENCES↗

SU-E-T-471: Small Field Jaw/MLC Reference Data

Purpose: In recent years the need for small field data of MLCs has increased due to the use of intensity-modulated radiation (IMRT), but moreover the use of stereotactic body radiation (SBRT) has increased, which uses not simply small field sizes, but small jaw and field sizes together. Having reference data for these small fields that is reliable would be invaluable to the physics community. Our study has gathered these values and the data distributions from the Radiological Physics Center's (RPC) site visits between 1990 and the present. Methods: For all measurements, the RPC used a 25 × 25 × 25cm water phantom placed at 100cm SSD. All measurements were made with an Exradin A16 cylindrical ion chamber at an effective depth of 10 cm. A total of 42 Varian machine measurements were used to compose the data for a 6 MV beam and 5 TrueBeam 6 MV flattening filter free (FFF) beams were used for FFF data. Results: Jaw/MLC fields were measured for both 6 MV and 6 MF FFF beams with the jaws and MLCs both at the following field sizes: 6×6, 4×4, 3×3, and 2×2cm. Measurements were normalized to the 10×10 field readings (defined by the jaws and MLC). Spread in the data was minimal and demonstrates a high level of accuracy of acquired data. Conclusion: Small field Jaw/MLC reference data for Varian 6MV and 6 MV FFF beams has been analyzed and presented here, composed of the aggregation of numerous RPC site visits. Obtaining reliable small field data remains difficult, however the RPC has collected high fidelity small field Jaw/MLC data. The data are presented as a reference along with their distributions, in such a way that the physicist can act based upon their own desired agreement with the reference data.

60 APPLIED LIFE SCIENCES↗