Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Cryogenic Propellant Densification Study

Ground and vehicle system requirements are evaluated for the use of densified cryogenic propellants in advanced space transportation systems. Propellants studied were slush and triple point liquid hydrogen, triple point liquid oxygen, and slush and triple point liquid methane. Areas of study included propellant production, storage, transfer, vehicle loading and system requirements definition. A savings of approximately 8.2 x 100,000 Kg can be achieved in single stage to orbit gross liftoff weight for a payload of 29,484 Kg by utilizing densified cryogens in place of normal boiling point propellants.

Ewart, R. O.↗

Cryogenic thermal diode heat pipes

The development of spiral artery cryogenic thermal diode heat pipes was continued. Ethane was the working fluid and stainless steel the heat pipe material in all cases. The major tasks included: (1) building a liquid blockage (blocking orifice) thermal diode suitable for the HEPP space flight experiment; (2) building a liquid trap thermal diode engineering model; (3) retesting the original liquid blockage engineering model, and (4) investigating the startup dynamics of artery cryogenic thermal diodes. An experimental investigation was also conducted into the wetting characteristics of ethane/stainless steel systems using a specially constructed chamber that permitted in situ observations.

Alario, J.↗

Cryogenic helium 2 systems for space applications

Two cryogenic systems are described which will provide cooling for experiments to be flown on Spacelab 2 in the early 1980's. The first system cools a scanning infrared telescope by the transfer of cold helium gas from a separate superfluid helium storage dewar. The flexible design permits the helium storage dewar and transfer assembly to be designed independent of the infrared experiment. Where possible, modified commerical apparatus is used. The second cryogenic system utilizes a specially designed superfluid dewar in which a superfluid helium experiment chamber is immersed. Each dewar system employs a porous plug as a phase separator to hold the liquid helium within the dewar and provide cold gas to a vent line. To maintain the low vapor pressure of the superfluid, each system requires nearly continuous prelaunch vacuum pump service, and each will vent to space during the Spacelab 2 flight.

Urban, E.↗

A cryogenic helium II system for Spacelab

A description is presented of a helium II storage and gas delivery system which is to provide refrigeration to a scanning infrared telescope experiment which will be flown in space in 1981 aboard the Spacelab 2 mission. Instead of submerging the infrared apparatus within a large, specially constructed helium dewar, which has been the usual approach to space cryogenics, it was decided to separate the cooled infrared optical system from the storage dewar. As a result of this decision the cryogenic supply system will be able to deliver gaseous or liquid helium cooling to other types of experiments on later Spacelab missions.

Urban, E. W.↗

Cryogenic wind tunnel activities at the University of Southampton

The characteristics and behavior of a 0.3m transonic cryogenic wind tunnel are discussed. The wide band of usable Reynolds numbers is analyzed along with a flow visualization technique using propane. The combination of magnetic suspension with the cryogenic wind tunnel is described. An outline of the circuit showing the locations of the magnet system and the features of the tunnel are presented.

Goodyer, M. J.↗

Cryogenic container compound suspension strap

A support strap for use in a cryogenic storage vessel for supporting the inner shell from the outer shell with a minimum heat leak is presented. The compound suspension strap is made from a unidirectional fiberglass epoxy composite material with an ultimate tensile strength and fatigue strength which are approximately doubled when the material is cooled to a cryogenic temperature.

Vorreiter, J. W.↗

Instrumentation for calibration and control of a continuous-flow cryogenic tunnel

Those aspects of selection and application of calibration and control instrumentation that are influenced by the extremes in the temperature environment to be found in cryogenic tunnels are described with emphasis on the instrumentation and data acquisition system used in the Langley 0.3 m transonic cryogenic tunnel. Typical calibration results obtained in a 20 by 60 cm two dimensional test section are included.

Ladson, C. L.↗

Preliminary design of the cryogenic cooled limb scanning interferometer radiometer (CLIR), phase 2

A cryogenic system to be utilized with a mounted pointing system is designed. The analysis indicates that the resulting design is significantly heavier than previous design due to the increased diameter of the system, resulting in greater tank and vacuum enclosure weights. Additional weight is also required in the area where the payload is attached to the pointing system in order to provide additional stiffness to the payload. The vacuum shell required to enclose the instrument is shorter and therefore an attendant reduction in instrument package weight would be expected. The primary resonance of the cooler instrument package occurs at 21 Hz, a mode in which the flexibility of the vacuum shell allows motion of the cryogen tank and instrument, and which can be increased by additional stiffening in the region of the pointing system vacuum shell connection at the cost of additional weight. The second resonance at 59 Hz is due to vibration of the helium tank on the fiberglass support tubes. The parasitic heat load can be reduced to 0.28 W by the utilization of a sandwich support tube structure in place of the monocoque structure assumed in the design.

Source record↗

A review of the NASA/OAST cryogenic coolers technology program

Low and ultra low temperature cryogenic cooler systems for future space missions include mechanical, solid cryogen, gas adsorption, superfluid helium, helium-3, and magnetic (adiabatic demagnetization) coolers. Operating lifetimes required vary from a few weeks for a Shuttle/Spacelab mission to as long as nine years for missions to the outer planets. Temperature requirements vary from tens to tenths of kelvin. At the higher temperature, cooling loads for detectors, instruments and associated shields may be as high as 15 watts. The general requirements for low and ultra low temperature and techniques that can be employed to achieve these temperatures at expected heat loads are discussed. The NASA Centers involved in the R & T efforts and the type of cooler systems on which they are focusing their effort are considered as well as the thrust of R & T effort for each cooler type. Projected missions that will use the technology are identified.

Lundholm, J. G., Jr.↗

Support assembly for cryogenically coolable low-noise choke waveguide

A compact cryogenically coolable choked waveguide for low-noise input coupling into a cryogenically cooled device, such as a maser or parametric amplifier, utilizes coaxial stainless steel support tubes surrounding the waveguide and connected in cascade to provide a folded low thermal conduction path. The edges of the tubes connected are welded.

Mccrea, F. E.↗

Development of thermal energy storage units for spacecraft cryogenic coolers

Thermal Energy Storage Units were developed for storing thermal energy required for operating Vuilleumier cryogenic space coolers. In the course of the development work the thermal characteristics of thermal energy storage material was investigated. By three distinctly different methods it was established that ternary salts did not release fusion energy as determined by ideality at the melting point of the eutectic salt. Phase change energy was released over a relatively wide range of temperature with a large change in volume. This strongly affects the amount of thermal energy that is available to the Vuilleumier cryogenic cooler at its operating temperature range and the amount of thermal energy that can be stored and released during a single storage cycle.

Richter, R.↗

Cryogenic wind tunnel force instrumentation

The paper outlines the work that has been accomplished at Langley Research Center (NASA) while investigating the effects of cryogenic environment on one-place multicomponent strain-gage balances. Particular emphasis is placed on cryogenic balances for use in the National Transonic Facility (NTF).

Ferris, J.↗

Modeling and control of a LN2-GN2 operated closed circuit cryogenic wind tunnel

An explicit but simple lumped parameter nonlinear multivariable model of a LN2-GN2-operated closed circuit cryogenic wind tunnel has been developed and its basic features have been experimentally validated. The model describes the mass-energy interaction involved in the cryogenic tunnel process and includes the real gas properties of nitrogen gas.

Balakrishna, S.↗

Simulation of flat-plate turbulent boundary layers in cryogenic tunnels

The magnitudes of real-gas effects on flat-plate turbulent boundary layer simulations in a cryogenic nitrogen wind tunnel are investigated in order to determine the validity of the method used by Inger (1979) to estimate real-gas effects. Boundary layer solutions for real gases, ideal gases with a specific heat ratio of 1.6 and ideal diatomic gases (specific heat ratio 1.4) were obtained for the worst case conditions of maximum stagnation pressure (9 atm), minimum stagnation temperature (120 K) and Mach number of 1.2. Calculated boundary layer parameters such as friction coefficient and displacement thickness are shown to agree closely for the real gas and the ideal diatomic gas (specific heat ratio 1.4), while the ideal gas solution used by Inger is shown to differ from the real-gas values considerably. Results indicate that real-gas effects on a flat-plate turbulent boundary layer simulation in a cryogenic nitrogen tunnel are insignificant, and suggest the unlikelihood of the large real-gas effects reported by Inger for turbulent boundary layer shock interactions.

Adcock, J.↗

NASA low and ultralow temperature cryogenic cooler systems for space missions

The paper describes the NASA research program to provide low and ultralow temperature cryogenic cooler systems for future space missions. These include mechanical, solid cryogen, superfluid helium, helium-3, and helium-3/helium-4 dilution coolers, and all systems must function in the zero gravity environment of space. The temperatures produced range from tens of kelvin down to a few millikelvin; at higher temperatures cooling loads for sensors or detectors and associated sun shields may range up to a few watts. At the ultralow temperature end, cooling loads must be limited to tens of microwatts.

Lundholm, J. G., Jr.↗

Model design and instrumentation experiences with continuous-flow cryogenic tunnels

The development of wind tunnels that can be operated at cryogenic temperatures has placed several new demands on the ability to build and instrument wind tunnel models. The experiences at the NASA Langley Research Center relative to the design and instrumentation of models for continuous flow cryogenic wind tunnels are reviewed.

Kilgore, R. A.↗

Force instrumentation for cryogenic wind tunnels using one-piece strain-gage balances

The use of cryogenic temperatures in wind tunnels to achieve high Reynolds numbers has imposed a harsh operating environment on the force balance. Laboratory tests were conducted to study the effect cryogenic temperatures have on balance materials, gages, wiring, solder, adhesives, and moisture proofing. Wind tunnel tests were conducted using a one piece three component balance to verify laboratory results. These initial studies indicate that satisfactory force data can be obtained under steady state conditions.

Ferris, A. T.↗

Measurements of temperature and pressure fluctuations in the T prime 2 cryogenic wind tunnel

Cold wire measurement of temperature fluctuations were made in a DERAT T'2 induction powered cryogenic wind tunnel for 2 types of liquid nitrogen injectors. Thermal turbulence measured in the tranquilization chamber depends to a great extent on the injector used; for fine spray of nitrogen drops, this level of turbulence seemed completely acceptable. Fluctuations in static pressure taken from the walls of the vein by Kulite sensors showed that there was no increase in aerodynamic noise during cryogenic gusts.

Blanchard, A.↗