Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Correction of Cardy–Verlinde formula for Fermions and Bosons with modified dispersion relation

Cardy–Verlinde formula links the entropy of conformal symmetry field to the total energy and its Casimir energy in a D-dimensional space. To correct black hole thermodynamics, modified dispersion relation can be used which is proposed as a general feature of quantum gravity approaches. In this paper, the thermodynamics of Schwarzschild four-dimensional black hole is corrected using the modified dispersion relation for Fermions and Bosons. Finally, using modified thermodynamics of Schwarzschild four-dimensional black hole, generalization for Cardy–Verlinde formula is obtained. - Highlights: • The modified Cardy–Verlinde formula obtained using MDR for Fermions and Bosons. • The modified entropy of the black hole used to correct the Cardy–Verlinde formula. • The modified entropy of the CFT has been obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correcting distortions of thin-walled machined parts by machine hammer peening

Thin-walled aerostructural components frequently get distorted after the machining process. Reworking to correct distortions or eventually rejecting parts significantly increases the cost. This paper proposes a new approach to correct distortions in thin-walled components by strategically applying hammer peening on target surfaces of a machined component. Aluminium alloy 7475-T7351 was chosen for this research. The study was divided in two stages. First, the residual stresses (RS) induced by four different pneumatic hammer peening conditions (modifying the stepover distance and initial offset) were characterised in a test coupon, and one of the conditions was selected for the next stage. In the second stage, a FEM model was used to predict distortions caused by machining in a representative workpiece. Then, the RS induced by hammer peening were included in an FEM model to define two hammer peening strategies (varying the coverage area) to analyse the capability to reduce distortions. Two workpieces were machined and then treated with the simulated hammer peening strategies for experimental validation. Results in the test coupon showed that pneumatic hammer peening can generate high compressive RS (-50 to –350 MPa) up to 800 μm depth, with their magnitude increasing with a reduced stepover distance. Application of hammer peening over 4% of the surface of the representative workpiece reduced the machining-induced distortions by 37%, and a coverage area of 100% led to and overcorrection by a factor of five. This confirms that hammer peening can be strategically applied (in target areas and changing the percentage of coverage) to correct low or severe distortions.

42 ENGINEERING↗

Margin Evaluation in the Presence of Deformation, Rotation, and Translation in Prostate and Entire Seminal Vesicle Irradiation With Daily Marker-Based Setup Corrections

Purpose: To develop a method for margin evaluation accounting for all measured displacements during treatment of prostate cancer. Methods and Materials: For 21 patients treated with stereographic targeting marker-based online translation corrections, dose distributions with varying margins and gradients were created. Sets of possible cumulative delivered dose distributions were simulated by moving voxels and accumulating dose per voxel. Voxel motion was simulated consistent with measured distributions of systematic and random displacements due to stereographic targeting inaccuracies, deformation, rotation, and intrafraction motion. The method of simulation maintained measured correlation of voxel motions due to organ deformation. Results: For the clinical target volume including prostate and seminal vesicles (SV), the probability that some part receives <95% of the prescribed dose, the changes in minimum dose, and volume receiving 95% of prescription dose compared with planning were 80.5% {+-} 19.2%, 9.0 {+-} 6.8 Gy, and 3.0% {+-} 3.7%, respectively, for the smallest studied margins (3 mm prostate, 5 mm SV) and steepest dose gradients. Corresponding values for largest margins (5 mm prostate, 8 mm SV) with a clinical intensity-modulated radiotherapy dose distribution were 46.5% {+-} 34.7%, 6.7 {+-} 5.8 Gy, and 1.6% {+-} 2.3%. For prostate-only clinical target volume, the values were 51.8% {+-} 17.7%, 3.3 {+-} 1.6 Gy, and 0.6% {+-} 0.5% with the smallest margins and 5.2% {+-} 7.4%, 1.8 {+-} 0.9 Gy, and 0.1% {+-} 0.1% for the largest margins. Addition of three-dimensional rotation corrections only improved these values slightly. All rectal planning constraints were met in the actual reconstructed doses for all studied margins. Conclusion: We developed a system for margin validation in the presence of deformations. In our population, a 5-mm margin provided sufficient dosimetric coverage for the prostate. In contrast, an 8-mm SV margin was still insufficient owing to deformations. Addition of three-dimensional rotation corrections was of minor influence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Clinical Release of an Online, Adaptive, Aperture-Based Image-Guided Radiotherapy Strategy in Intensity-Modulated Radiotherapy to Correct for Inter- and Intrafractional Rotations of the Prostate

Purpose: We developed and evaluated a correction strategy for prostate rotations using direct adaptation of segments in intensity-modulated radiotherapy (IMRT). Method and Materials: Implanted fiducials (four gold markers) were used to determine interfractional translations, rotations, and dilations of the prostate. We used hybrid imaging: The markers were automatically detected in two pretreatment planar X-ray projections; their actual position in three-dimensional space was reconstructed from these images at first. The structure set comprising prostate, seminal vesicles, and adjacent rectum wall was transformed accordingly in 6 degrees of freedom. Shapes of IMRT segments were geometrically adapted in a class solution forward-planning approach, derived within seconds on-site and treated immediately. Intrafractional movements were followed in MV electronic portal images captured on the fly. Results: In 31 of 39 patients, for 833 of 1013 fractions (supine, flat couch, knee support, comfortably full bladder, empty rectum, no intraprostatic marker migrations >2 mm of more than one marker), the online aperture adaptation allowed safe reduction of margins clinical target volume-planning target volume (prostate) down to 5 mm when only interfractional corrections were applied: Dominant L-R rotations were found to be 5.3 Degree-Sign (mean of means), standard deviation of means {+-}4.9 Degree-Sign , maximum at 30.7 Degree-Sign . Three-dimensional vector translations relative to skin markings were 9.3 {+-} 4.4 mm (maximum, 23.6 mm). Intrafractional movements in 7.7 {+-} 1.5 min (maximum, 15.1 min) between kV imaging and last beam's electronic portal images showed further L-R rotations of 2.5 Degree-Sign {+-} 2.3 Degree-Sign (maximum, 26.9 Degree-Sign ), and three-dimensional vector translations of 3.0 {+-}3.7 mm (maximum, 10.2 mm). Addressing intrafractional errors could further reduce margins to 3 mm. Conclusion: We demonstrated the clinical feasibility of an online adaptive image-guided, intensity-modulated prostate protocol on a standard linear accelerator to correct 6 degrees of freedom of internal organ motion, allowing safe and straightforward implementation of margin reduction and dose escalation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-induced temperature correction for inter-phase heat transfer in Euler-Lagrange point-particle simulation

In a two-way coupled Euler-Lagrange simulation, particles are approximated as point sources and their momentum and energy exchange with the surrounding flow are modeled through point-particle force and heat transfer models. As the particle size increases and approaches the Eulerian grid, the feedback force and heat transfer become large and strongly affect the local flow at the particle location. The fluid velocity and temperature computed in the EL simulation when interpolated to the particle location will be substantially different from the corresponding undisturbed values. In this work we will follow the approach pursued in Balachandar et al. (2018) [1] for self-induced velocity correction to develop an analogous correction procedure for self-induced temperature. We obtain analytical solutions for the self-induced thermal perturbation for a steady uniform cross flow past a Gaussian filtered heat source under both steady and unsteady conditions. The analytical results are extended to finite Peclet number using numerical simulations. The resulting quasi-steady and unsteady models are tested with a simple problem of exponential thermal evolution against the corresponding EL simulation results. We also provide a simple criterion for when the self-induced temperature correction is needed in an Euler-Lagrange simulation.

42 ENGINEERING↗

Residual-based error correction for neural operator accelerated infinite-dimensional Bayesian inverse problems

We explore using neural operators, or neural network representations of nonlinear maps between function spaces, to accelerate infinite-dimensional Bayesian inverse problems (BIPs) with models governed by nonlinear parametric partial differential equations (PDEs). Neural operators have gained significant attention in recent years for their ability to approximate the parameter-to-solution maps defined by PDEs using as training data solutions of PDEs at a limited number of parameter samples. The computational cost of BIPs can be drastically reduced if the large number of PDE solves required for posterior characterization are replaced with evaluations of trained neural operators. However, reducing error in the resulting BIP solutions via reducing the approximation error of the neural operators in training can be challenging and unreliable. We provide an a priori error bound result that implies certain BIPs can be ill-conditioned to the approximation error of neural operators, thus leading to inaccessible accuracy requirements in training. To reliably deploy neural operators in BIPs, we consider a strategy for enhancing the performance of neural operators: correcting the prediction of a trained neural operator by solving a linear variational problem based on the PDE residual. We show that a trained neural operator with error correction can achieve a quadratic reduction of its approximation error, all while retaining substantial computational speedups of posterior sampling when models are governed by highly nonlinear PDEs. The strategy is applied to two numerical examples of BIPs based on a nonlinear reaction–diffusion problem and deformation of hyperelastic materials. We demonstrate that posterior representations of the two BIPs produced using trained neural operators are greatly and consistently enhanced by error correction.

97 MATHEMATICS AND COMPUTING↗

Experimental validation of heterogeneity-corrected dose-volume prescription on respiratory-averaged CT images in stereotactic body radiotherapy for moving tumors

The purpose of this study was to experimentally assess the validity of heterogeneity-corrected dose-volume prescription on respiratory-averaged computed tomography (RACT) images in stereotactic body radiotherapy (SBRT) for moving tumors. Four-dimensional computed tomography (CT) data were acquired while a dynamic anthropomorphic thorax phantom with a solitary target moved. Motion pattern was based on cos (t) with a constant respiration period of 4.0 sec along the longitudinal axis of the CT couch. The extent of motion (A{sub 1}) was set in the range of 0.0-12.0 mm at 3.0-mm intervals. Treatment planning with the heterogeneity-corrected dose-volume prescription was designed on RACT images. A new commercially available Monte Carlo algorithm of well-commissioned 6-MV photon beam was used for dose calculation. Dosimetric effects of intrafractional tumor motion were then investigated experimentally under the same conditions as 4D CT simulation using the dynamic anthropomorphic thorax phantom, films, and an ionization chamber. The passing rate of {gamma} index was 98.18%, with the criteria of 3 mm/3%. The dose error between the planned and the measured isocenter dose in moving condition was within {+-} 0.7%. From the dose area histograms on the film, the mean {+-} standard deviation of the dose covering 100% of the cross section of the target was 102.32 {+-} 1.20% (range, 100.59-103.49%). By contrast, the irradiated areas receiving more than 95% dose for A{sub 1} = 12 mm were 1.46 and 1.33 times larger than those for A{sub 1} = 0 mm in the coronal and sagittal planes, respectively. This phantom study demonstrated that the cross section of the target received 100% dose under moving conditions in both the coronal and sagittal planes, suggesting that the heterogeneity-corrected dose-volume prescription on RACT images is acceptable in SBRT for moving tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Problem of overlapping formation times: In-medium virtual corrections for QCD

High energy particles traversing through medium primarily lose energy by showering through hard bremsstrahlung and pair production. These splitting processes are coherent over large distances in the very high energy limit, leading to suppression from the Landau-Pomeranchuk-Migdal (LPM) effect. Avoiding soft-emission approximations, we study the cases where the coherence lengths of two consecutive splittings overlap (which is important for calculating corrections to LPM effect in QCD). Here, we will show how to compute in-medium virtual corrections to the leading order LPM emission rates for QCD. These loop corrections will be necessary for calculating properties of in-medium high energy parton showers. To simplify the calculations, we will focus on the all-gluon case and work in the large-Nc limit of QCD, where Nc is the number of colors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coulomb field correction due to virtual $e$ + $e$ - production in heavy ion collisions

The correction to the Coulomb energy due to virtual production of $e$ + $e$ - pairs, which is on the order of one percent of the Coulomb energy at nuclear scales is discussed. The effects of including a pair-production term in the semi-empirical mass formula and the correction to the Coulomb barrier for a handful of nuclear collisions using the Bass and Coulomb potentials are studied. Furthermore, with an eye toward future work using Constrained Molecular Dynamics (CoMD) model, we also calculate the correction to the Coulomb energy and force between protons after folding with a Gaussian spatial distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of energy correction coefficient for neutron albedo dosimeter. Three approaches

To accurately determine dose, albedo TLD dosimeters require application of a neutron energy correction factor (NECF). Here, in this paper, the results from three different methods were used to determine NECFs. In the first method, NECF values were calculated as a ratio of the known “conventional true” dose and the neutron dose reported by albedo dosimeter(s) irradiated on a phantom. The results from this direct method were utilized for verification of two other methods. The second method used a specially designed device called the Neutron Area Monitor (NAM) model 5. The third method of NECF determination was based on the response of a BF 3 tube under different levels of moderation. The results of this work showed that the Navy-developed Neutron Area Monitor (NAM) model 5 measures NECF values correctly when irradiated with 252 Cf (bare and D 2 O-moderated). This was an important result, because it validated the use of the NAM-5 in nuclear power and marine propulsion reactors, as their neutron energy spectrum is approximated by the field of a Cadmium-coated 30 cm diameter steel sphere of D 2 O moderated 252 Cf. In the case of a broad neutron energy spectrum the 6 Li response to the small amount of slow neutrons outweighs its response to the fast neutrons overwhelmingly responsible for the neutron dose rate. Based on the obtained results we can conclude that NAM-5 provides correct NECF determination if the fraction of slow neutrons in the neutron dose rate is more than 20%. A satisfactory correlation between the NECF determined by NAM-5 and the multi-moderated BF3 tube method was observed, but the multi-moderated BF 3 tube values were ~30% lower than those obtained by the NAM-5 at the same locations for broader neutron energy spectrum locations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correcting nonlinearity and mass-bias in measurements by ICP quadrupole mass spectrometry

A two-parameter modeling formula is proposed for quadrupole ICP-MS (ICP-QMS) data, which corrects for nonlinearity with a “dead-time” function and makes subsequent weighted mass-bias corrections to normalize isotope ratio data to pertinent isotopic reference materials. The methodology improves the short-term and long-term precision as well as accuracy of the measurements. Applying the model to isotopes spanning a wide mass range revealed that values for the parameters describing nonlinearity and mass bias do not conform to expectations based on conventional interpretation. Within a single analysis run for a specific element, nonlinearity and mass-bias corrections can be evaluated to very tight tolerances and the model fits the data to within a few parts per thousand. However, in a different run or with a different element, the values of the parameters might change. A comprehensive strategy for conducting measurements of isotope ratios or trace-element concentrations is described, which takes advantage of the model’s strengths and accommodates the observed run-to-run variations. in conclusion, supporting data is presented to demonstrate improved precision and accuracy with the widely available ICP-QMS system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Machine learning-based bias-corrected future projections of ozone concentrations from a chemistry-climate model

Reliable projection of future near-surface ozone is crucial for air quality management and health risk assessment. However, potential biases in spatial distribution, magnitude and trends in ozone concentrations simulated by global chemistry-climate models limit their applicability in regional-scale evaluations. In this study, LightGBM, a machine learning (ML) algorithm is applied to correct biases in CESM2-simulated ozone concentrations over China, the United States and Europe and calibrate future ozone projections under two diverse Shared Socioeconomic Pathways (SSP1-2.6 and SSP5-8.5) scenarios from 2020 to 2060. The ML-based correction significantly improves the spatial distribution and reduces the model bias by 40%–60%. It also reverses the potentially incorrect trend of ozone change under SSP1-2.6 in eastern China. When applying ML-based bias correction to CESM2 future projections, warm season mean ozone concentrations decrease across China, the United States, and Europe by –13.5, –17.9, and –13.7 µg/m³, respectively, between 2020 and 2060 in SSP1-2.6, while they increase by 9.4, 2.0, and 5.2 µg/m³ in SSP5-8.5. Decomposition analysis show that changes in anthropogenic emissions dominate future ozone changes in both scenarios, while strong climate penalty from ozone changes occurs in polluted eastern China and climate benefit is found in western China, the United States and Europe under SSP5-8.5. These findings demonstrate the value of combining ML with chemistry-climate models to produce more accurate air quality projections, thereby informing more effective and region-specific environmental protection strategies.

Chemistry Model↗

Biased Spin-State Energetics of Fe(II) Molecular Complexes within Density-Functional Theory and the Linear-Response Hubbard U Correction

The spin-state energetics of six Fe(II) molecular complexes are computed using the linear-response Hubbard U approach within DFT. The adiabatic energy differences, ΔE H-L , between the high-spin (S = 2) and the low-spin (S = 0) states are computed and compared with accurate-coupled cluster-corrected CASPT2 results. We show that DFT+U fails in correctly capturing the ground state for strong-field ligands yielding ΔE H-L that are almost constant throughout the molecular series. This bias toward high spin together with the metal/ligand charge transfer upon U correction are here quantified and explained using molecular orbital diagrams involving both σ- and π-bonding interactions. Furthermore, with increasing ligand-field strengths this bias also increases owing to the stronger molecular character of the metal/ligand Kohn–Sham orbitals thus resulting in large deviations from the reference larger than 4 eV. Smaller values of U can be employed to mitigate this effect and recover the right energetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Complex Orbitals, Multiple Local Minima, and Symmetry Breaking in Perdew–Zunger Self-Interaction Corrected Density Functional Theory Calculations

Implentation of seminumerical stability analysis for calculations using the Perdew-Zunger self-interaction correction is described. It is shown that real-valued solutions of the Perdew-Zunger equations for gas phase atoms are unstable with respect to imaginary orbital rotations, confirming that a proper implementation of the correction requires complex-valued orbitals. The orbital density dependence of the self-interaction corrected functional is found to lead to multiple local minima in the case of the acrylic acid, H 6 , and benzene molecules. Finally, in the case of benzene, symmetry breaking that results in incorrect ground state geometry is found to occur, erroneously leading to alternating bond lengths in the molecule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Local Spin Density Approximation Strongly Improved by a Better-Informed Local Scaling of Its Self-Interaction Correction

The Perdew−Zunger self-interaction correction (PZSIC) makes density functional approximations (DFAs) exact for all one-electron densities. However, it overcorrects in manyelectron regions, introducing errors for the uniform-density limit, where uncorrected DFAs are exact. The locally scaled PZSIC (LSIC), based on the iso-orbital indicator zσ [which distinguishes single-orbital and slowly varying density regions and is used with the local spin density approximation (LSDA)], restores the uniform-density limit and significantly improves results for many properties, including chemical reaction barrier heights, atomization energies, and ionization potentials. Yet, LSIC performs poorly for weakly bonded systems, leaving many unbound, due to limitations of its iso-orbital indicator. To correct this, in this work we propose a new local scaling, LSIC-α, based on the iso-orbital indicator ασ (which additionally identifies regions of overlapping density tails). A two-parameter scaling function of ασ is fitted to a subset of the nonbonded appropriate norms for the SCAN and r2SCAN meta- GGAs, and tested on many properties of main-group atoms, molecules, and molecular complexes. LSIC-α greatly improves the interaction energies of weakly bonded systems in the S22 data set while retaining LSIC’s accuracy for other properties. This work shows that the errors of LSDA (and presumably of higher-level DFAs) can be largely but not entirely repaired by a proper “do no harm” self-interaction correction.

Approximation↗

Study of Self-Interaction Errors in Density Functional Calculations of Magnetic Exchange Coupling Constants Using Three Self-Interaction Correction Methods

We examine the role of self-interaction errors (SIE) removal on the evaluation of magnetic exchange coupling constants. In particular we analyze the effect of scaling down the self-interaction-correction (SIC) for three non-empirical density functional approximations (DFAs) namely, the local spin density approximation, the Perdew-Burke-Ernzerhof generalized gradient approximation, and recent SCAN family of meta-GGA functionals. To this end, we employ three one-electron SIC methods: Perdew-Zunger [Perdew, J. P.; Zunger, A. Phys. Rev. B, 1981, 23, 5048] SIC, the orbitalwise scaled SIC method [Vydrov, O. A. et al., J. Chem. Phys. 2006, 124, 094108], and the recent local scaling method [Zope, R. R. et al., J. Chem. Phys. 2019, 151, 214108]. We compute the magnetic exchange coupling constants using the spin projection and non projection approaches for sets of molecules composed of dinuclear and polynuclear H-He models, organic radical molecules, and chlorocuprate, and compare these results against accurate theories and experiment. Our results show that for the systems that mainly consist of single electron regions, PZSIC performs well but for more complex organic systems and the chlorcuprates, an overcorrecting tendency of PZSIC combined with the DFAs utilized in this work is more pronounced, and in such cases LSIC with kinetic energy density ratio performs better than PZSIC. Furthermore, analysis of the results in terms of SIC corrections to the density and to the total energy shows that both density and energy correction are required to obtain an improved prediction of magnetic exchange couplings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Attractive Way to Correct for Missing Singles Excitations in Unitary Coupled Cluster Doubles Theory

Coupled cluster methods based exclusively on double excitations are comparatively “cheap” and interesting model chemistries, as they are typically able to capture the bulk of the dynamic electron correlation effects. The trade-off in such approximations is that the effect of neglected excitations, particularly single excitations, can be considerable. Using standard and electron-pair-restricted T 2 operators to define two flavors of unitary coupled cluster doubles (UCCD) methods, we investigate the extent to which missing single excitations can be recovered from low-order corrections in many-body perturbation theory (MBPT) within the unitary coupled cluster (UCC) formalism. Here, our analysis includes the derivations of finite-order UCC energy functionals, which are used as a basis to define perturbative estimates of missed single excitations. This leads to the novel UCCD[4S] and UCCD[6S] methods, which consider energy corrections for missing single excitations through fourth- and sixth-order in MBPT, respectively. We also apply the same methodology to the electron-pair-restricted ansatz, but the improvements are only marginal. Our findings show that augmenting UCCD with these post hoc perturbative corrections can lead to UCCSD-quality results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

van der Waals Correction to the Physisorption of Graphene on Metal Surfaces

Adsorption is a scientifically and technologically important interfacial phenomenon, which however presents challenges to conventional density functional theory (DFT) due to the long-range van der Waals (vdW) interactions. We have developed a model of long-range vdW correction for physisorption of graphene (G) on metals with the Lifshitz–Zaremba–Kohn second-order perturbation theory, by incorporating dipole- and quadrupole-surface interactions and screening effects. The physisorption energies calculated by the model between graphene and eight metal surfaces (Al, Ni, Co, Pd, Pt, Cu, Ag, and Au), and the adsorption energies for the same G/metal structures from self-consistent DFT PBE (Perdew–Burke–Ernzerhof) calculations, are obtained in a range of distances between G and the metal surfaces. The sum of these two parts is the total adsorption energy as a function of the distance, from which the equilibrium distance and the binding energy are determined simultaneously. The results show high accuracy, with the mean absolute error (MAE) of binding energy of 7 meV and the MAE of equilibrium distance of 0.2 Å, significantly improving upon other vdW methods. Here, the PBE + vdW binding energy curves give better fits to the random phase approximation curves around the equilibrium distances than do the curves of other methods considered here. The higher-order quadrupole-surface correction is important and accounts for about 30% of the total vdW correction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗