Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

A Numerical Study of Two-Phase Flow and Interfacial Mass Transfer in a Wetted Wall Column for Counter-Current Gas Absorption

We present a numerical study to investigate the effects of surface waves of falling films on the mass transfer from flowing gas phase into the liquid film. The model employs the volume of fluid method to explicitly track the gas-liquid phase interface and a one-fluid formulation to model the multiphase flow coupled with mass transfer between the two phases. The surface waves are generated by the time-varying injection rate of the falling film. The effects of surface wave frequencies and amplitudes on the overall mass transfer also are investigated for a counter-current gas-liquid flow of oxygen and water. Because of the solubility difference in the two phases, the model can capture the concentration discontinuity across the liquid-gas interface. Good agreement is obtained between the numerical results and experimental data reported in the literature. By systematically varying the frequencies and amplitudes of flow rate for the falling film, the surface waves generated on the film surface enhance mass transfer in general. Here, the model prediction shows a proportional increase in mass transfer for small frequencies of surface waves, but saturation at higher frequencies.

42 ENGINEERING↗

Design of Column Separation Processes for Recovery of Molybdenum from Dissolved High-Density LEU Target

The Global Threat Reduction Initiative (GTRI) Conversion Program develops technology necessary to convert civilian facilities that use high enriched uranium (HEU) to low enriched uranium (LEU) fuels and targets. The conversion from conventional HEU dispersion targets to LEU for 99Mo production requires approximately five times the uranium in a target to maintain the 99 Mo yield per target. Under GTRI, Argonne National Laboratory (Argonne) is developing two frontend options for the current processes to allow the use of LEU-foil targets. In both processes, the aim is to produce a product after the frontend that will be compatible with current purification operations and that will, with the same number of targets irradiated, provide the same or a higher yield of 99 Mo at the end of processing. The goal of the frontend process is to deliver a product solution that is of the same or higher Mo purity than the current solution and is of equal or better compatibility with current purification process. In the first frontend option, the LEU foil (contained in a thin [10–15 µm] Ni fission-recoil barrier is removed from the annular target and dissolved in nitric acid. In the dissolution, the uranium, nickel, and all fission and activation products are dissolved; the solution will be ~7 mM Mo and ~450 g-U/L, and the nitric-acid concentration after dissolution will be ~1 M. The volume of solution is assumed to be 500 mL and the pressure drop, ΔP, constraint of 0.8 atm is based on the use of a vacuum/gravity fluid transfer system. Therefore pressure loss is limited to <1 atm; hence a value of 0.8 is chosen.

Stepinski, D. C.↗

Evaluation of Gas Retention in Waste Simulants: Tall Column Experiments

Gas generation in Hanford’s underground waste storage tanks can lead to gas accumulation within the layer of settled solids (sludge) at the tank bottom. The gas, which typically has hydrogen as the major component together with other flammable species, is formed principally by radiation-driven chemical reactions. Accumulation of these gases within the sludge in a waste tank is undesirable and limits the amount of tank volume for waste storage. Further, accumulation of large amounts of gas in the sludge may potentially result in an unacceptable release of the accumulated gas if the sludge-layer density is reduced to less than that of the overlying sludge or that of the supernatant liquid. Rapid release of large amounts of flammable gases could endanger personnel and equipment near the tank. For this reason, a thorough understanding of the circumstances that can lead to a potentially problematic gas accumulation in sludge layers is needed. To respond to this need, the Deep Sludge Gas Release Event Program (DSGREP) was commissioned to examine gas release behavior in sludges.

Gas Retention↗

Evaluation of Gas Retention in Waste Simulants: Intermediate-Scale Column and Open-Channel-Depth Tests

Gas generation in Hanford’s radioactive waste storage tanks can lead to gas accumulation within the layer of settled solids (sludge) at the tank bottom. The gas, which may be hazardous and/or flammable, is formed principally by radiation-driven chemical reactions. Accumulation of these gases within the sludge increases the sludge-layer volume, which decreases the available tank volume for waste storage. Further, accumulation of large amounts of gas in the sludge can potentially result in a relatively rapid release of the accumulated gas if the sludge-layer density is reduced to less than that of the overlying sludge or that of the supernatant liquid. The potential for rapid release of large amounts of hazardous and/or flammable gases is a safety hazard that needs to be managed. Accordingly, a thorough understanding is needed of the circumstances that can lead to problematic gas accumulation in sludge layers. The Deep-Sludge Gas Release Event Project (DSGREP) is tasked with developing an improved understanding of these gas release events.

Gas retention↗

Mooring Design for the Floating Oscillating Water Column Reference Model

To reduce the price of the reference Backward Bent Duct Buoy (BBDB), a study was done analyzing the effects of reducing the mooring line length, and a new mooring design was developed. It was found that the overall length of the mooring lines could be reduced by 1290 meters, allowing a significant price reduction of the system. In this paper, we will first give a description of the model and the storm environment it will be subject to. We will then give a recommendation for the new mooring system, followed by a discussion of the severe weather simulation results, and an analysis of the conservative and aggressive aspects of the design.

42 ENGINEERING↗

Crystalline Silicotitanate Ion Exchange Column Sizing and Sensitivity Study in Support of the Hanford Test Bed Initiative

The Environmental Management Office of the Department of Energy (DOE) is spearheading a Test Bed Initiative a (TBI) to treat and dispose 2,000 gallons of tank waste from Hanford. One step in the process is to remove radioactive 137 Cs from the waste using Crystalline Silicotitanate b (CST) ion exchange media. This report describes the modeling performed to provide an estimate of the volume of a bed of CST required to meet the design requirements. Sensitivity studies were also performed to help provide project guidance. This modeling effort assumed 2100 gallons of waste to be processed (i.e., entire 2000 gallon campaign plus a 100 gallon margin).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New Design Methods and Algorithms for Energy Efficient Multicomponent Distillation Column Trains (Final Report)

The major objectives of this project are to; first develop new methods and tools, and then incorporate them in a user-friendly software that will readily generate low-energy solutions for a large class of multicomponent distillation applications found in typical chemical and petrochemical plants. Having such methods and corresponding software at the disposal of the process engineers will allow chemical manufacturers of all sizes to reduce energy consumption of their grassroots as well as existing separation plants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ion Exchange Processing of AP-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The U.S. Department of Energy (DOE) is working to expedite processing of Hanford tank waste supernate at the Hanford Waste Treatment and Immobilization Plant (WTP). To support this goal, Washington River Protection Solutions, LLC (WRPS, Richland, WA) is designing a system for suspended solids and cesium (Cs/ 137 Cs) removal from Hanford tank waste supernate. The effluent will then be sent to the WTP Low-Activity Waste (LAW) Facility for vitrification. The Cs removal is critical for eliminating the high dose rate associated with 137 Cs and facilitating a contact maintenance philosophy for the LAW Facility. The maximum 137 Cs concentration in the LAW sent to the WTP is targeted to be below the 3.18E-5 Ci 137 Cs/mole of Na waste acceptance criteria (WAC) limit. The filtration and ion exchange systems will be placed near the Hanford tanks and are collectively termed the Tank Side Cesium Removal (TSCR) system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗