Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bias correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Surface Segregation Studies in Ternary Noble Metal Alloys: Comparing DFT and Machine Learning with Experimental Data

Abstract Surface segregation, whereby the surface composition of an alloy differs systematically from the bulk, has historically been hard to study, because it requires experimental and modeling methods that span alloy composition space. In this work, we study surface segregation in catalytically relevant noble and platinum‐group metal alloys with a focus on three ternary systems: AgAuCu, AuCuPd, and CuPdPt. We develop a data set of 2478 fcc slabs with those compositions including all three low‐index crystallographic orientations relaxed with Density Functional Theory using the PBEsol functional with D3 dispersion corrections. We fine‐tune a machine learning model on this data and use the model in a series of 1800 Monte Carlo simulations spanning ternary composition space for each surface orientation and ternary chemical system. The results of these simulations are validated against prior experimental surface segregation data collected using composition spread alloy films for AgAuCu and AuCuPd. Our findings reveal that simulations conducted using the (110) orientation most closely match experimentally observed surface segregation trends, and while predicted trends qualitatively match observation, biases in the PBEsol functional limit numeric accuracy. This study advances understanding of surface segregation and the utility of computational studies and highlights the need for further improvements in simulation accuracy.

Chemistry↗

Preliminary OARE absolute acceleration measurements on STS-50

On-orbit Orbital Acceleration Research Experiment (OARE) data on STS-50 was examined in detail during a 2-day time period. Absolute acceleration levels were derived at the OARE location, the orbiter center-of-gravity, and at the STS-50 spacelab Crystal Growth Facility. The tri-axial OARE raw acceleration measurements (i.e., telemetered data) during the interval were filtered using a sliding trimmed mean filter in order to remove large acceleration spikes (e.g., thrusters) and reduce the noise. Twelve OARE measured biases in each acceleration channel during the 2-day interval were analyzed and applied to the filtered data. Similarly, the in situ measured x-axis scale factors in the sensor's most sensitive range were also analyzed and applied to the data. Due to equipment problem(s) on this flight, both y- and z- axis sensitive range scale factors were determined in a separate process (using the OARE maneuver data) and subsequently applied to the data. All known significant low-frequency corrections at the OARE location (i.e., both vertical and horizontal gravity-gradient, and rotational effects) were removed from the filtered data in order to produce the acceleration components at the orbiter's center-of-gravity, which are the aerodynamic signals along each body axes. Results indicate that there is a force of unknown origin being applied to the Orbiter in addition to the aerodynamic forces. The OARE instrument and all known gravitational and electromagnetic forces were reexamined, but none produce the observed effect. Thus, it is tentatively concluded that the Orbiter is creating the environment observed.

Blanchard, Robert C.↗

Absolute acceleration measurements on STS-50 from the Orbital Acceleration Research Experiment (OARE)

Orbital Acceleration Research Experiment (OARE) data on Space Transportation System (STS)-50 have been examined in detail during a 2-day time period. Absolute acceleration levels have been derived at the OARE location, the orbiter center-of-gravity, and at the STS-50 spacelab Crystal Growth Facility. During the interval, the tri-axial OARE raw telemetered acceleration measurements have been filtered using a sliding trimmed mean filter in order to remove large acceleration spikes (e.g., thrusters) and reduce the noise. Twelve OARE measured biases in each acceleration channel during the 2-day interval have been analyzed and applied to the filtered data. Similarly, the in situ measured x-axis scale factors in the sensor's most sensitive range were also analyzed and applied to the data. Due to equipment problem(s) on this flight, both y- and z-axis sensitive range scale factors were determined in a separate process using orbiter maneuvers and subsequently applied to the data. All known significant low-frequency corrections at the OARE location (i.e., both vertical and horizontal gravity-gradient, and rotational effects) were removed from the filtered data in order to produce the acceleration components at the orbiter center-of-gravity, which are the aerodynamic signals along each body axis. Results indicate that there is a force being applied to the Orbiter in addition to the aerodynamic forces. The OARE instrument and all known gravitational and electromagnetic forces have been reexamined, but none produces the observed effect. Thus, it is tentatively concluded that the orbiter is creating the environment observed. At least part of this force is thought to be due to the Flash Evaporator System.

Blanchard, Robert C.↗

An extended source for CN jets in Comet P/Halley

We examined radial intensity profiles of CN jets in comparison with the diffuse, isotropic component of the CN coma of Comet P/Halley. All images were bias-subtracted, flat-fielded, and continuum-subtracted. We calculated the diffuse profiles by finding the azimuthal mean of the coma least contaminated by jets yielding profiles similar to those of vectorial and Haser models of simple photodissociation. We found the jet profiles by calculating a mean around a Gaussian-fitted center in r-theta space. There is an unmistakable difference between the profiles of the CN jets and the profiles of the diffuse CN. Spatial derivatives of these profiles, corrected for geometrical expansion, show that the diffuse component is consistent with a simple photodissociation process, but the jet component is not. The peak production of the jet profile occurs 6000 km from the nucleus at a heliocentric distance of 1.4 AU. Modeling of both components of the coma indicate results that are consistent with the diffuse CN photochemically produced, but the CN jets need an additional extended source. We found that about one-half of the CN in the coma of Comet P/Halley originated from the jets, the rest from the diffuse component. These features, along with the width of the jet being approximately constant, are consistent with a CHON grain origin for the jets.

Klavetter, James Jay↗

The impact of pulse width modulation on heat accumulation in AlGaN channel HEMTs

The poor thermal properties of Aluminum–Gallium Nitride (AlGaN) channel High Electron Mobility Transistors (HEMTs) on sapphire limit the device’s maximum switching frequency due to high channel temperatures. Extracting the correct thermal time constants can provide guidelines for the device’s safe frequency operation. This study experimentally quantifies the impact of pulse width and duty cycle on the transient thermal dynamics of multi-finger AlGaN channel HEMTs. In most transient thermal metrology, lock-in averaging approaches are leveraged to increase signal-to-noise ratio and measure the device’s relative temperature rise. Assuming no heat accumulation, the temperature rise is used to quantify the device’s thermal resistance under continued pulsed biasing. For devices grown on sapphire substrates, however, heat accumulation leads to elevated reference temperatures and causes the differential measurement to underestimate the peak temperature. This study demonstrates the capability of transient Gate Resistance Thermometry (tGRT) to measure the absolute temperature, which is required to precisely evaluate the device’s thermal resistance. When an absolute temperature measurement is not feasible (such as thermoreflectance imaging), a solution is proposed to derive the peak temperature under pulsed biasing based on the differential temperature under pulsing and the steady-state thermal resistance (which is typically easier to obtain). Finally, additional tGRT (without averaging) is performed to demonstrate the temperature-dependent thermal time constants required to minimize heat accumulation effects.

Field effect transistors↗

The magnitude-redshift relation for 561 Abell clusters

The Hubble diagram for the 561 Abell clusters with measured redshifts has been examined using Abell's (1958) corrected photo-red magnitudes for the tenth-ranked cluster member (m10). After correction for the Scott effect and K dimming, the data are in good agreement with a linear magnitude-redshift relation with a slope of 0.2 out to z = 0.1. New redshift data are also presented for 20 Abell clusters. Abell's m10 is suitable for redshift estimation for clusters with m10 of no more than 16.5. At fainter m10, the number of foreground galaxies expected within an Abell radius is large enough to make identification of the tenth-ranked galaxy difficult. Interlopers bias the estimated redshift toward low values at high redshift. Leir and van den Bergh's (1977) redshift estimates suffer from this same bias but to a smaller degree because of the use of multiple cluster parameters. Constraints on deviations of cluster velocities from the mean cosmological flow require greater photometric accuracy than is provided by Abell's m10 magnitudes.

Postman, M.↗

Photometric cross-calibration of the SDSS Stripe 82 Standard Stars catalogue with Gaia EDR3, and comparison with Pan-STARRS1, DES, CFIS, and GALEX catalogues

ABSTRACT We extend the SDSS Stripe 82 Standard Stars catalogue with post-2007 SDSS imaging data. This improved version lists averaged SDSS ugriz photometry for nearly a million stars brighter than r ∼ 22 mag. With 2–3 times more measurements per star, random errors are 1.4–1.7 times smaller than in the original catalogue, and about three times smaller than for individual SDSS runs. Random errors in the new catalogue are $\lesssim$0.01 mag for stars brighter than 20.0, 21.0, 21.0, 20.5, and 19.0 mag in u, g, r, i, and z-bands, respectively. We achieve this error threshold by using the Gaia Early Data Release 3 (EDR3) Gmag photometry to derive grey photometric zeropoint corrections, as functions of RA and Declination, for the SDSS catalogue, and use the Gaia BP–RP colour to derive corrections in the ugiz bands, relative to the r-band. The quality of the recalibrated photometry, tested against Pan-STARRS1, DES, CFIS, and GALEX surveys, indicates spatial variations of photometric zeropoints ≦ 0.01 mag (rms), with typical values of 3–7 millimag in the RA, and 1–2 millimag in the Declination directions, except for $\lesssim$6 millimag scatter in the u-band. We also report a few minor photometric problems with other surveys considered here, including a magnitude-dependent ∼0.01 mag bias between 16 ≤ GGaia ≤ 20 in the Gaia EDR3. Our new, publicly available catalogue offers robust calibration of ugriz photometry below 1 per cent level, and will be helpful during the commissioning of the Vera C. Rubin Observatory Legacy Survey of Space and Time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Satellite remote sensing of sea surface temperature

An overview is conducted of the satellite methods available for investigating sea-surface temperature (SST). Attention is given to the accuracies expected from specific satellite instruments and retrieval methods. The techniques reviewed include IR radiometry, corrections for atmospheric attenuation and cloudiness, and the combination of AVHRR and High-resolution IR Sounder channels. The analytical derivations of surface emission (microwave and IR) and radiative transfer are demonstrated, and the theoretically derived SST retrieval algorithms are discussed for both microwave and IR sensors. The accuracies of satellite and in situ SST products are compared with attention given to the use of composite SST products. The AVHRR data are found to be self-consistent and provide the lowest rms errors and bias variations, and the occurrence of satellite anomalies are considered acceptable in the light of in situ data which does not adequately represent the SST field.

Njoku, Eni G.↗

Evaluating the design of an Earth Radiation Budget Instrument with systen simulations. Part 1: Instantaneous estimates

A set of system simulations has been performed to evaluate candidate scanner designs for an Earth Radiation Budget Instrument (ERBI) for the Earth Observing System (EOS) of the late 1990s. Five different instruments are considered: (1) the Active Cavity Array (ACA), (2) the Clouds and Earth's Radiant Energy System-Instrument (CERES-I), (3) the Conically Scanning Radiometer (CSR), (4) the Earth Radiation Budget Experiment Cross-Track Scanner (ERBE), and (5) the Nimbus-7 Biaxial Scanner (N7). Errors in instantaneous, top-of-the-atmosphere (TOA) satellite flux estimates are assumed to arise from two measurement problems: the sampling of space over a given geographic domain, and sampling in angle about a given spatial location. When angular sampling errors vanish due to the application of correct angular dependence models (ADMs) during inversion, the accuracy of each scanner design is determined by the instrument's ability to map the TOA radiance field in a uniform manner. In this regard, the instruments containing a cross-track scanning component (CERES-I and ERBE) do best. As errors in ADMs are encountered, cross-track instruments incur angular sampling errors more rapidly than biaxial instruments (N7, ACA, and CSR) and eventually overtake the biaxial designs in their total error amounts. A latitude bias (north-south error gradient) in the ADM error of cross-track instruments also exists. This would be objectionable when ADM errors are systematic over large areas of the globe. For instantaneous errors, however, cross-track scanners outperform biaxial or conical scanners for 2.5 deg latitude x 2.5 deg longitude target areas, providing that the ADM error is less than or equal to 30%. A key issue is the amount of systematic ADM error (departures from the mean models) that is present at the 2.5 deg resolution of the ERBE target areas. If this error is less than 30%, then the CERES-I, ERBE, and CSR, in order of increasing error, provide the most accurate instantaneous flux estimates, within 2-3 W/sq m of each other in reflected shortwave flux. The magnitude of this error is near the 10 W/sq m accuracy requirement of the user community. Longwave flux errors have been found to have the same space and time characteristics as errors in shortwave radiation, but only about 25% as large.

Stowe, Larry↗

Simulation of the Climate of South-West Asia with a Regional Model

The ability of the regional model RegCM2 to simulate the climate of South-West Asia is examined. The climate of the region displays high spatial, seasonal and interannual variability, providing a strong test of climate model capabilities. RegCM2 captures the spatial variability of temperature and precipitation despite cold biases being present in the model. RegCM2 does not capture the annual cycle of precipitation on the Black and Caspian Sea coasts where very steep topography exists, nor on the eastern Mediterranean coast where the coastal mountains are not resolvable. RegCM2 does capture the seasonal cycle in the Fertile Crescent and Zagros mountains, where it is strongly influenced by a plateau circulation above the Iranian plateau. It is shown that accurate simulation of precipitation in these regions, including the inter-annual variability, requires the correct simulation of both storm tracks and topographic interactions. Through the use of regional climate models the concentration and transport pathways of water vapor through the Middle East can be explored. The results demonstrate that short lived 'events' have little impact on monthly mean atmospheric fields yet provide a significant amount of the precipitated water which flows in the Tigris river.

Evans, J. P.↗

Inter-Calibration and Concatenation of Climate Quality Infrared Cloudy Radiances from Multiple Instruments

A change in climate is not likely captured from any single instrument, since no single instrument can span decades of time. Therefore, to detect signals of global climate change, observations from many instruments on different platforms have to be concatenated. This requires careful and detailed consideration of instrumental differences such as footprint size, diurnal cycle of observations, and relative biases in the spectral brightness temperatures. Furthermore, a common basic assumption is that the data quality is independent of the observed scene and therefore can be determined using clear scene data. However, as will be demonstrated, this is not necessarily a valid assumption as the globe is mostly cloudy. In this study we highlight challenges in inter-calibration and concatenation of infrared radiances from multiple instruments by focusing on the analysis of deep convective or anvil clouds. TRMM/VIRS is potentially useful instrument to make correction for observational differences in the local time and foot print sizes, and thus could be applied retroactively to vintage instruments such as AIRS, IASI, IRIS, AVHRR, and HIRS. As the first step, in this study, we investigate and discuss to what extent AIRS and VIRS agree in capturing deep cloudy radiances at the same local time. The analysis also includes comparisons with one year observations from CrIS. It was found that the instruments show calibration differences of about 1K under deep cloudy scenes that can vary as a function of land type and local time of observation. The sensitivity of footprint size, view angle, and spectral band-pass differences cannot fully explain the observed differences. The observed discrepancies can be considered as a measure of the magnitude of issues which will arise in the comparison of legacy data with current data.

cloudy radiance↗

Global Validation of Columnar Water Vapor Derived from EOS MODIS-MAIAC Algorithm Against the Ground-Based AERONET Observations

The water vapor is a relevant greenhouse gas in the Earth's climate system, and satellite products become one of the most effective way to characterize and monitor the columnar water vapor (CWV) content at global scale. Recently, a new product (MCD19) was released as part of MODIS (Moderate Resolution Imaging Spectroradiometer) Collection 6 (C6). This operational product from the Multi-Angle Implementation for Atmospheric Correction (MAIAC) algorithm includes a high 1-kilometer resolution CWV retrievals. This study presents the first global validation of MAIAC C6 CWV obtained from MODIS MCD19A2 product. This evaluation was performed using Aerosol Robotic Network (AERONET) observations at 265 sites (2000-2017). Overall, the results show a good agreement between MAIAC/AERONET CWV retrievals, with correlation coefficient higher than 0.95 and RMS (Root Mean Square) error lower than 0.250 centimeters. The binned error analysis revealed an underestimation (approximately 10 percent) of Aqua CWV retrievals with negative bias for CWV higher than 3.0 centimeters. In contrast, Terra CWV retrievals show a slope of regression close to unity and a low mean bias of 0.075 centimeters. While the accuracy is relatively similar between 1.0 and 5.0 centimeters for both sensor products, Terra dataset is more reliable for applications in humid tropical areas (less than 5.0 centimeters). The expected error was defined as plus or minus 15 percent, with less than 68 percent of retrievals falling within this envelope. However, the accuracy is regionally dependent, and lower error should be expected in some regions, such as South America and Oceania. Since MODIS instruments have exceeded their design lifetime, time series analysis was also presented for both sensor products. The temporal analysis revealed a systematic offset of global average between Terra and Aqua CWV records. We also found an upward trend (approximately 0.2 centimeters per decade) in Terra CWV retrievals, while Aqua CWV retrievals remain stable over time. The sensor degradation influences the ability to detect climate signals, and this study indicates the need for revisiting calibration of the MODIS bands 17-19, mainly for Terra instrument, to assure the quality of the MODIS water vapor product. Finally, this study presents a comprehensive validation analysis of MAIAC CWV over land, raising the understanding of its overall quality.

MAIAC↗

Energy Scales in X-Ray Microcalorimeters

Microcalorimeter pulse shape characteristics, such as pulse height, decay time and rise time, are dependent on the detector temperature and bias as well as the photon energy and flux. We examine the nature of the temperature dependency by illuminating the ASTRO-E2 X-ray Spectrometer (XRS) microcalorimeter array with X-rays generated by electron impact on a range of foil targets. The resulting pulses are collected for a range of detector temperatures. We observe and model the temperature dependence of the pulse shape characteristics by fitting the data with non-linear pulse models. Our aim is to determine a robust method for correcting the energy scale obtained in ground calibration for slight differences in the operating conditions while in orbit.

Tillotson, W. A.↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Ionospheric effects on one-way timing signals

A proposed navigation concept requires that a user measure the time-delay that satellite-emitted signals experience in traversing the distance between satellite and user. Simultaneous measurement of the propagation time from four different satellites permits the user to determine his position and clock bias if satellite ephemerides and signal propagation velocity are known. A pulse propagating through the ionosphere is slowed down somewhat, giving an apparent range that is larger than the equivalent free space range. The difference between the apparent range and the true range, or the free space velocity and the true velocity, is the quantity of interest. This quantity is directly proportional to the total electron content along the path of the propagating signal. Thus, if the total electron content is known, or is measured, a perfect correction to ranging could be performed. Faraday polarization measurements are continuously being taken at Fort Monmouth, N. J., using beacon emissions of the ATS-3 (137.35 MHz) satellite. Day-to-day variability of the diurnal variation of total electron content values is present with differences of up to 50% or more not being uncommon. In addition, superposed on the overall diurnal variation are smaller scale variations of approximately 5 to 10% of the total content which are attributed to ionospheric density irregularities.

Soicher, H.↗

Forward-bias capacitance and current measurements for determining lifetimes and band narrowing in p-n junction solar cells

A new method is described and illustrated for determining the minority-carrier diffusion length and lifetime in the base region of p-n junction solar cells. The method requires only capacitance measurements at the device terminals and its accuracy is estimated to be + or - 5%. It is applied to a set of silicon p-n junction devices and the values of the diffusion lengths agree with those obtained using the current response to X-ray excitation but disagree with those obtained by the OCVD method. The reasons for the relative inaccuracy of OCVD applied to silicon devices are discussed. The capacitance method includes corrections for a two-dimensional fringing effects which occur in small area devices. For a device having highly-doped base region and surface (emitter) layer, the method can be extended to enable the determination of material properties of the degenerately doped surface layer. These material properties include the phenomenological emitter lifetime and a measure of the energy band-gap narrowing in the emitter. An alternate method for determining the energy band-gap narrowing from temperature dependence of emitter current is discussed and demonstrated.

Neugroschel, A.↗