Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “actuators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

An evaluation plan of bus architectures and protocols using the NASA Ames intelligent redundant actuation system

Means for evaluating data bus architectures and protocols for highly integrated flight control system applications are needed. Described are the criteria and plans to do this by using the NASA/Ames Intelligent Redundant Actuation System (IRAS) experimental set-up. Candidate bus architectures differ from one another in terms of: topology, access control, message transfer schemes, message characteristics, initialization. data flow control, transmission rates, fault tolerance, and time synchronization. The evaluation criteria are developed relative to these features. A preliminary, analytical evaluation of four candidate busses (MIL-STD-1553B, DATAC, Ethernet, and HSIS) is described. A bus must be exercised in a real-time environment to evaluate its dynamic characteristics. A plan for real-time evaluation of these four busses using a combination of hardware and simulation techniques is presented.

Defeo, P.↗

The 15-meter diameter hoop/column antenna surface control actuator system

The design, development, and implementation status of the Surface Control Actuator System (SCAS) for the Hoop/Column Antenna are described with the primary focus on the design of the mechanical element. The SCAS is an electromechanical system that will automatically adjust the antenna shape by changing the length of control cords. Achieving and maintaining the proper surface shape and smoothness are critical to optimizing the electromagnetic characteristics of the antenna.

Ahl, Elvin L., Jr.↗

Evaluation of a high-torque backlash-free roller actuator

The results are presented of a test program that evaluated the stiffness, accuracy, torque ripple, frictional losses, and torque holding capability of a 16:1 ratio, 430 N-m (320 ft-lb) planetary roller drive for a potential space vehicle actuator application. The drive's planet roller supporting structure and bearings were found to be the largest contributors to overall drive compliance, accounting for more than half the total. In comparison, the traction roller contacts themselves contributed only 9 percent of the drive's compliance based on an experimentally verified stiffnesss model. Torque ripple tests showed the drive to be extremely smooth, actually providing some damping of input torsional oscillations. The drive also demonstrated the ability to hold static torque with drifts of 7 arc sec or less over a 24-hour period at 35 percent of full load.

Steinetz, Bruce M.↗

On the stability of adaptive pole-placement controllers with a saturating actuator

The question of how existing pole-placement algorithms work in the case of a saturating input is addressed. The stability of such algorithms and the modifications needed to make them work in the presence of saturation are examined. The net results of this examination are: a mathematical condition for closed-loop stability; physical intuition behind this condition; some explanation of why adaptive control has been successfully implemented, even while ignoring saturation; and some design rules for doing adaptive control on linear plants with saturating actuators.

Abramovitch, Daniel Y.↗

Three-Position Cryogenic Actuator

Linear actuator set at one of three positions by supplying gas at suitable pressure. Designed for use as part of relief valve in system storing liquid oxygen. Stops at any of three positions, depending on pressure at supply port. Seals made of polytetrafluorethylene for low friction at low temperatures. Use of polytetrafluoroethylene and large clearances reduces friction and makes possible operating over range of temperatures from -420 to 250 degree F (-251 to 121 degree C).

Allen, Peter B.↗

An advanced actuator for high-performance slewing

A conceptual design for an advanced momentum exchange actuator for application to spacecraft slewing is described. The particular concept is a magnetically-suspended, magnetically gimballed Control Moment Gyro (CMG). A scissored pair of these devices is sized to provide the torque and angular momentum capacity required to reorient a large spacecraft through large angle maneuvers. The concept described utilizes a composite material rotor to achieve the high momentum and energy densities to minimize system mass, an advanced superconducting magnetic suspension system to minimize system weight and power consumption. The magnetic suspension system is also capable of allowing for large angle gimballing of the rotor, thus eliminating the mass and reliability penalties attendant to conventional gimbals. Descriptions of the various subelement designs are included along with the necessary system sizing formulation and material.

Downer, James↗

Design of feedback control systems for unstable plants with saturating actuators

A new control design methodology is introduced for multi-input/multi-output systems with unstable open loop plants and saturating actuators. A control system is designed using well known linear control theory techniques and then a reference prefilter is introduced so that when the references are sufficiently small, the control system operates linearly as designated. For signals large enough to cause saturations, the control law is modified in such a way to ensure stability and to preserve, to the extent possible, the behavior of the linear control design. Key benefits of this methodology are: the modified feedback system never produces saturating control signals, integrators and/or slow dynamics in the compensator never windup, the directionaL properties of the controls are maintained, and the closed loop system has certain guaranteed stability properties. The advantages of the new design methodology are illustrated in the simulation of an approximation of the AFTI-16 (Advanced Fighter Technology Integration) aircraft multivariable longitudinal dynamics.

Kapasouris, Petros↗

Kinematic calibration of manipulators with closed loop actuated joints

A method for performing forward kinematic calibration of manipulators having one or more closed-loop-actuated joints is presented. The technique is an extension of algorithms designed for open-loop jointed manipulators. The calibration is equivalent to minimizing an objective function subject to constraints. The objective function is taken as the integral of end-effector position and orientation error. The constraints arise from the closed-loop mechanisms present in the manipulator.

Everett, Louis J.↗

Improved Voice-Coil Actuators Have Lower Copper Losses

Improved design concept for electromagnetic linear-motion actuators of loudspeaker-voice-coil type reduces both copper losses (dissipation of power in electrical resistances of windings) and magnetic interference with other equipment. Includes closed magnetic circuit, which suppresses fringing flux. Pr/Fe/B permanent magnets yield better performance at lower temperatures. Intended for use where power supplies limited, heating must be minimized, and/or adequate performance at temperatures far below ambient required.

Simizu, Satoru↗

Independent Orbiter Assessment (IOA): Analysis of the mechanical actuation subsystem

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Mechanical Actuation System (MAS) hardware. Specifically, the MAS hardware consists of the following components: Air Data Probe (ADP); Elevon Seal Panel (ESP); External Tank Umbilical (ETU); Ku-Band Deploy (KBD); Payload Bay Doors (PBD); Payload Bay Radiators (PBR); Personnel Hatches (PH); Vent Door Mechanism (VDM); and Startracker Door Mechanism (SDM). The IOA analysis process utilized available MAS hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.

Bacher, J. L.↗

Independent Orbiter Assessment (IOA): Assessment of the mechanical actuation subsystem, volume 1

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine draft failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline that was available. A resolution of each discrepancy from the comparison was provided through additional analysis as required. These discrepancies were flagged as issues, and recommendations were made based on the FMEA data available at the time. This report documents the results of that comparison for the Orbiter Mechanical Actuation System (MAS) hardware. Specifically, the MAS hardware consists of the following components: Air Data Probe (ADP); Elevon Seal Panel (ESP); External Tank Umbilical (ETU); Ku-Band Deploy (KBD); Payload Bay Doors (PBD); Payload Bay Radiators (PBR); Personnel Hatches (PH); Vent Door Mechanism (VDM); and Startracker Door Mechanism (SDM). Criticality was assigned based upon the severity of the effect for each failure mode.

Bradway, M. W.↗

Independent Orbiter Assessment (IOA): Assessment of the mechanical actuation subsystem, volume 2

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine draft failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline that was available. A resolution of each discrepancy from the comparison was provided through additional analysis as required. These discrepancies were flagged as issues, and recommendations were made based on the FMEA data available at the time. This report documents the results of that comparison for the Orbiter Mechanical Actuation System (MAS) hardware. Specifically, the MAS hardware consists of the following components: Air Data Probe (ADP); Elevon Seal Panel (ESP); External Tank Umbilical (ETU); Ku-Band Deploy (KBD); Payload Bay Doors (PBD); Payload Bay Radiators (PBR); Personnel Hatches (PH); Vent Door Mechanism (VDM); and Startracker Door Mechanism (SDM). Criticality was assigned based upon the severity of the effect for each failure mode. Volume 2 continues the presentation of IOA analysis worksheets and contains the potential critical items list, detailed analysis, and NASA FMEA/CIL to IOA worksheet cross reference and recommendations.

Bradway, M. W.↗

Development of shape memory metal as the actuator of a fail safe mechanism

A small, compact, lightweight device was developed using shape memory alloy (SMA) in wire form to actuate a pin-puller that decouples the flanges of two shafts. When the SMA is heated it contracts producing a useful force and stroke. As it cools, it can be reset (elongated in this case) by applying a relatively small force. Resistive heating is accomplished by running a current through the SMA wire for a controlled length of time. The electronics to drive the device are not elaborate or complicated, consisting of a timed current source. The total available contraction is 3 percent of the length of the wire. This device, the engineering properties of the SMA, and the tests performed to verify the design concept are described.

Ford, V. G.↗

Actuated forebody strakes

Actuated forebody strakes provide yaw control at high angles of attack. In one embodiment, the strakes are axially slidable in the forebody to be deployed out of slots provided for the strakes in the forebody. In another embodiment, the strakes are pivotally connected at the tip of the strakes to pivot radially outwardly out of the slots provided in the forebody. In another embodiment, the forebody is provided with either a single strake or two strakes and the forebody is rotatable to vary the radial location of the strake or strakes. All embodiments achieve significant yaw control capability over a wide angle of attack and sideslip ranges.

Daniel G Murri↗

Robot path planning with obstacles, actuator, gripper, and payload constraints

A method is presented to obtain the time-optimal motions for robotic manipulators. It considers the full nonlinear dynamics of the manipulator, its actuator saturation limits, and gripper and payload constraints. It also accounts for both the presence of obstacles in the work space and restrictions on the motion of the manipulator's joints. The method is computationally practical and has been implemented for the optimal trajectory planning of general six degree-of-freedom manipulators. Examples are presented that demonstrate the substantial improvement in manipulator performance that can be achieved using this method.

Shiller, Zvi↗

Test and theory for piezoelectric actuator-active vibration control of rotating machinery

The application of piezoelectric actuators for active vibration control (AVC) of rotating machinery is examined. Theory is derived and the resulting predictions are shown to agree closely with results of tests performed on an air turbine driven-overhung rotor. The test results show significant reduction in unbalance, transient and sub-synchronous responses. Results from a 30-hour endurance test support the AVD system reliability. Various aspects of the electro-mechanical stability of the control system are also discussed and illustrated. Finally, application of the AVC system to an actual jet engine is discussed.

Palazzolo, A. B.↗

Quick-Actuating Closure And Handling System

Quick-actuating closure and handling system developed for containers, particularly for high-pressure vessels or shells entered frequently. Features simplicity in design and operation, saving of time, monitoring of leakage, and safety. Another significant feature, use of conical surfaces to engage effectively shear blocks in locked position to provide necessary preload and to transmit internal-pressure load directly to pressure vessel. Designed to impart proper radial movement to shear blocks, based on space available for longitudinal travel of screwjacks. Adaptable to many applications; used for such containers as autoclaves, vacuum chambers, and wide variety of specialized vessels requiring frequent entry and closure.

White, Dorsey E.↗

Thermally Actuated Unlatching Mechanism

Thermally actuated latch releases component initially secured to it, when cooled to predetermined temperature lower than initial temperature. Includes supporting arm and spring-loaded hook made of titanium, and engaging arm made of epoxy or high-density polyethylene. As latch cools, engaging arm shrinks away from hook, and spring drives hook away from arm. Latch used to retain cover of cryogenic aerospace instrument during launch through intermediate cooling. With nonmoving hook, latch used to prevent door of industrial furnace from being opened until furnace cools to safe temperature.

Ford, Virginia G.↗