Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WAVELENGTHS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Improved Determination of Europa's Long-Wavelength Topography Using Stellar Occultations

Europa Clipper will arrive at Jupiter at the end of this decade and will explore Europa through a series of flybys. One of its many goals is to characterize Europa's topography and global shape using the Europa Imaging System and Radar for Europa Assessment and Sounding: Ocean to Near-surface (REASON) instruments. In addition, Europa Clipper's UV Spectrograph will observe stars pass behind (be occulted by) Europa. The spectrograph has sufficiently precise timing, corresponding to a topographic precision of order meters, that these occultations can also serve as altimetric measurements. Because of gaps in the REASON radar altimeter coverage imposed by the flyby geometries, the addition of ∼100 occultations results in a substantial improvement in the recovery of Europa's long-wavelength shape. Typically, five extra spherical harmonic degrees of topography can be recovered by combining occultations with radar altimetry.

Jacob N. H. Abrahams↗

Backscattering enhancement with a finite beam width for millimeter - wavelength weather radars

Backscattering enhancement from random hydrometeors should increase as wavelengths of radars reach millimeter regions. For 95 GHz radars, the reflectivity of backscattering is expected to increase by 2 dB, due to multiple scattering including backscattering enhancement, for water droplets of diameter of 1 mm with a density of 5×103 m−3. Previous theoretical studies of backscattering enhancement considered infinitely extending plane waves. In this paper, we expand the theory to spherical waves with a Gaussian antenna pattern, including depolarizing effects. While the differences from the plane wave results are not great when the optical thickness is small, as the latter increases the differences become significant, and essentially depend on the ratio of radar footprint radius to the mean free path of hydrometeors. In this regime, for a radar footprint that is smaller than the mean free path, the backscattering-enhancement reflectivity corresponding to spherical waves is significantly less pronounced than in the case of the plane wave theory. Hence this reduction factor must be taken into account when analyzing radar reflectivity factors for use in remote sensing applications.

Im, Eastwood↗

Large format long-wavelength infrared narrow-band, multi-band, and broad-band QWIP focal plane arrays

A 640x512 pixel, long-wavelength cutoff, narrow-band quantum well infrared photodetector focal pllay array, a four-band QWIP FPA in 4-16 um spectral region, and a broad-band QWIP FPA having 15.4 mum cutoff have been demonstrated. In this paper we discuss the detector designs, dark currents, quantum efficiencies, responsivities, detectivities, noise equivalent differential temperatures, the effect of FPA nonuniformity on performance, and the operabilities of these QWIP FPAs.

Mumolo, J. M.↗

Very Long Wavelength Intersubband Infrared Hot Electron Transistor

We have demonstrated the first very long wavelength (16 micrometer) infrared hot electron transistor (IHET). This device utilizes a bound to continuum quantum well infrared photodetector (QWIP) as a photosensitive emitter, a wide quantum well as a base, and a thick Al_xGa_(1-x)As barrier between the base and the collector as an energy discriminating filter. This energy filter blocks the lower energy electrons, which drain through the base while higher energy photo electrons pass to the collector. Therefore, the detectivity of the device at the collector is much higher than the detectivity at the emitter.

Park, J.S.↗

640 X 512 pixel long-wavelength infrared narrowband, multiband, and broadband QWIP focal plane arrays

A 640 512 pixel, long-wavelength cutoff, narrowband(delta lambda/lambda ~ 10%) quantum-well infrared photodetector(QWIP) focal plane array (FPA), a four-band QWIP FPA in the 4??m spectral region, and a broadband (delta lambda/lambda ~ 42%)QWIP FPA having a 15.4 m cutoff have been demonstrated. In this paper, we discuss the electrical and optical characterization of these FPAs, and their performance. In addition, we discuss the development of a very sensitive (NEDT ~ 10.6 mK) 640 X 512 pixel thermal imaging camera having a 9 lambda m cutoff.

broadband↗

In Situ Mg/Ca Measurements on Foraminifera: Comparison Between Laser Ablation Inductively Coupled Plasma Mass Spectrometry and Wavelength-Dispersive X-Ray Spectroscopy by Electron Probe Microanalyzer

We present a comparison of two different techniques: Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) and wavelength-dispersive X-Ray Spectroscopy by electron probe microanalyzer (EPMA) for obtaining Mg/Ca ratios in individual foraminifera shells. The goal is to assess the use of EPMA as an alternative technique for Mg/Ca analyses of single foraminiferal calcite shells. Foraminifera obtained from sediments (benthic, Uvigerina spp.) and from plankton tows (planktonic, Orbulina universa) were analyzed. All specimens were prepared in epoxy mounts and exposed in cross-section such that multiple high-resolution analyses could be completed on the shells using both techniques. We examined our data using statistical methods designed for the assessment and comparison of measurement techniques. In the case of Uvigerina, the mean difference for ratios obtained using EPMA and LA-ICP-MS is very small (−0.046 mmol mol−1) and scale independent. The Limits of Agreement (LoA, the standard deviation of the bias plus the mean bias) is [−0.315, 0.223] mmol mol−1. For samples with ratios lower than 13 mmol mol−1, we found a mean EPMA–LA-ICP-MS bias of −2.44 mmol mol−1 and a corresponding LoA of [−3.85, −1.04] mmol mol−1. For ratios higher than 13 mmol mol−1, there appears to be a scale dependent bias, meaning that the EPMA measured ratios become progressively larger than those of LA-ICP-MS as the Mg/Ca ratio increases, so the mean bias and LoA metrics are not meaningful. Results indicate that it is possible to use EPMA to collect Mg/Ca data, if the ratios are lower than ∼13 mmol mol−1.

EPMA↗

Improvements to the Search for Cosmic Dawn Using the Long Wavelength Array

We present recent improvements to the search for the global Cosmic Dawn signature using the Long Wavelength Array station located on the Sevilleta National Wildlife Refuge in New Mexico, USA (LWA{SV). These improvements are both in the methodology of the experiment and the hardware of the station. An improved observing strategy along with more sophisticated temperature calibration and foreground modelling schemes have led to improved residual RMS limits. A large improvement over previous work using LWA{SV is the use of a novel achromatic beamforming technique which has been developed for LWA{SV. We present results from an observing campaign which contains 29 days of observations between March 10th, 2021 and April 10th 2021. The reported residual RMS limits are 6 times above the amplitude of the potential signal reported by the Experiment to Detect the Global EoR Signature (EDGES) collaboration.

Christopher Dilullo↗

Design, Calibration, and Application of A Cryogenic Low-Background Infrared Radiometer for Spectral Irradiance and Radiance Measurements From 4- to 20-μm Wavelength

We have constructed, calibrated, and tested a cryogenic low-background infrared (IR) radiometer for both spectral radiance and irradiance measurements over the 4- to 20-μm wavelength range. The primary purpose of the Missile Defense Transfer Radiometer (MDXR) is to measure absolute irradiance or radiance from cryogenic IR test chamber sources using a photoconductive Si:As blocked-impurity band (BIB) detector and a set of spectral filters. The MDXR also includes an absolute cryogenic radiometer (ACR) and a Fourier-transform spectrometer (FTS). For irradiance measurements, the ACR is used to provide the primary power scale for the BIB detector in conjunction with spectral filters, whereas the FTS/BIB configuration derives its scale from an internal blackbody source. The two measurement scales show agreement for the irradiance of highly collimated (<1 mrad) IR beams from 10 -13 to 10 -8 W / μm / cm 2 within the combined relative uncertainties of 2.6% (coverage factor k = 1.) We have also calibrated the radiometer for radiance measurements using a large cavity fluid bath blackbody that overfills the spatial and angular extent of the radiometer entrance pupil. The radiometric calibration uncertainty analysis of the radiometer and its maintenance and stability are discussed.

radiometry↗

Surface Biology and Geology (SBG) Visible to Short Wavelength Infrared (VSWIR) Wide Swath Instrument Concept

The 2017 Decadal Survey: Thriving on Our Changing Planet, A Decadal Strategy for Earth Observation from Space has called new observations including global coverage Visible to Short Wavelength Infrared (VSWIR) Wide Swath (WS) imaging spectroscopy measurements as part of the Surface Biology and Geology (SBG) Designated Observable. The SBG VSWIR-WS along with the companion SBG Thermal Infrared (TIR) imager is an important element of NASA’s larger Earth System Observatory (ESO).

Walch, Marc↗

Mapping Cloud Microphysical Properties to Triple-Wavelength Airborne Lidar Measurements in Winter Storms: Results from the IMPACTS Field Campaign

Ice production and growth inmixed-phase cloudsgive a complicated picture of the radiative and mass characteristics due to the heterogeneity of particle shapes and sizes. Collocated airborne lidar and microphysics datasets from a recent winter storm field study are used to evaluate the effect of ice and liquid hydrometeors,observed in situ,on the multiple-wavelength backscatter coefficientvalues measured by the NASA Cloud Physics Lidarover the course of three winter deployments in the Midwestand Northeast United States.

Joseph A. Finlon↗

Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air

Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. However, the reflectance of PTFE is a function of its thickness. In this work, we investigate this dependence in air for light of wavelengths 260 nm and 450 nm using two complementary methods. We find that PTFE reflectance for thicknesses from 5 mm to 10 mm ranges from 92.5% to 94.5% at 450 nm, and from 90.0% to 92.0% at 260 nm. We also see that the reflectance of PTFE of a given thickness can vary by as much as 2.7% within the same piece of material. Finally, we show that placing a specular reflector behind the PTFE can recover the loss of reflectance in the visible without introducing a specular component in the reflectance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavelength selective filtering with non-radial array of microstructure elements

A non-radial array of microstructure elements provides enhanced wavelength selective filtering. The elements are arranged along a line that does not intersect the center of the core. In this configuration, the first coupling element in an array that is nearest to the core is a non-integer array unit spacing from the main waveguide where the array unit spacing is defined as the flat to flat distance of a hexagonal cell.

Kiani, Leily S.↗

Fabrication of a Monolithic 5-Meter Aluminum Reflector for Millimeter-Wavelength Observations of the Cosmic Microwave Background

We have demonstrated the fabrication of a monolithic, 5-meter diameter, aluminum reflector with 17.4 $\mu$m RMS surface error. The reflector was designed to avoid the problem of pickup due to scattering from panel gaps in a large, millimeter-wavelength telescope that will be used for measurements on the cosmic microwave background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Rayleigh Scattering in Liquid Argon at Vacuum Ultraviolet Wavelengths

Liquid argon based detectors are limited in scintillation light analysis capabilities due to inconsistent measurements of fundamental constants essential for the reconstruction of scintillation events. This experiment measures the Rayleigh scattering length of vacuum ultraviolet light propagating in liquid argon in support of liquid argon experiments. Preliminary results are presented for the Rayleigh scattering length in a range of vacuum ultraviolet wavelengths. Current data collection and analysis methods in this measurement require further advancements to understand and eliminate anomalous phenomena in the data. Future measurements in this experiment aim to precisely measure the liquid argon ultraviolet light scattering length. Results will contribute to the development of new photon system analysis methods for liquid argon experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of scintillation light in noble gases with wavelength-shifting optical fibers

Wavelength-shifting (WLS) techniques enable particle detectors based on noble gases, whose scintillation light is predominantly emitted in the vacuum-ultraviolet. We investigate WLS fibers coated with tetraphenyl butadiene (TPB) for scintillation light detection in gaseous xenon and argon at pressures up to 8.5 bar, motivated by future high-pressure xenon time-projection chambers of the NEXT program. Two detector configurations are studied: an elongated high-pressure vessel with four PTFE panels equipped with WLS fibers read by temperature-stabilized SiPMs, and a compact box-shaped detector operated at 1 bar Xe with WLS fibers read out by PMTs. Both operate with continuous gas purification. The detector response is characterized using cosmic muons and alpha particles from a $^{241}$Am source. With the SiPM setup, we measure a light collection efficiency (LCE) of ${1.18 \pm 0.01~\mathrm{(sta.)}~^{+0.07}_{-0.09}~\mathrm{(sys.)}~\%}$ for xenon and ${1.07 \pm 0.01~\mathrm{(sta.)}~^{+0.06}_{-0.08}~\mathrm{(sys.)}~\%}$ for argon. With PMT readout, we measure a LCE of ${0.45 \pm 0.01~\mathrm{(sta.)} \pm 0.05~\mathrm{(sys.)}~\%}$ in xenon, in agreement with the SiPM result once photon detection efficiency is accounted for. Average scintillation waveforms in xenon and argon are studied to assess the time structure of the emitted light. Cosmic-muon measurements yield a mean energy required to produce a scintillation photon $45\pm7~\mathrm{(sta.)}~^{+4}_{-5}~\mathrm{(sys.)}~\mathrm{eV}$ at 1.5 bar, in agreement with the literature. The results demonstrate that TPB-coated WLS fiber systems can reliably detect scintillation light in high-pressure gaseous noble detectors, with a LCE representing an upper limit for realistic large-scale TPCs, where additional photon losses from materials and fiber attenuation are expected.

Soleti, S. R. [Donostia Intl. Phys. Ctr., San Seba↗