Define Minimum Safe Operational Volume for Aerial Vehicles in Upper Class E Airspace

This work presents both analytical and simulation studies for defining the minimum safe operational volume needed for aerial vehicles operating in upper Class E airspace. The analytical study is conducted first to investigate factors that affect the minimum safe operational volume, such as position errors, wake/vortex, vehicle maneuverability, communication and surveillance, control/operator response time. A mathematical approach is developed to compute the boundary of the safe operational volume required by the limited aircraft maneuverability and an analytical sensitivity study is then performed with varying parameters. After the analytical study, simulations are then conducted to verify the results from the analytical study. Simulation results will be included in the final paper.

Separation standard, well-clear definition, upper ↗

Spacesuit Reach Capability and Work Volume Assessment

Work volumes and reach envelopes define the locations where work objects or interfaces can be placed around a person to reduce ergonomic risk. Spacesuits, however, show unique reach patterns, due to the stiffness and mechanical constraints from pressurization. This study measured the reach motion patterns and capabilities from subjects wearing a pressurized spacesuit using a 3D motion capture system. The subjects performed arm and hand motions, focusing on extreme lateral and vertical positions. These motions defined the maximum ranges. They also performed on-suit reaches to measure where they could or couldn’t reach on the suit surface to determine where critical controls and devices could be placed on the suit. A parametric model of the reach volume was statistically built using the collected hand position data. The observed shape and size of the work volume substantially vary by persons, depending on anthropometry and strength capability. It was also indicated that the traditional metrics (e.g., simple spherical or cylindrical representations) estimated from “unsuited” persons or computer simulations may not accurately capture such variations. The results of this study can help to design and optimize space hardware and task activities, to protect crewmembers from overexertion or injuries.

Han Kim↗

Controlling the pressure within an annular volume of a wellbore

A process is described for replacing at least a portion of the liquid within the annular volume of a casing system within a wellbore with a second liquid. The second liquid is preselected to provide a measure of control of the pressure within the annular volume as the fluid within the volume is being heated.

42 ENGINEERING↗

Controlling the pressure within an annular volume of a wellbore

A process is described for replacing at least a portion of the liquid within the annular volume of a casing system within a wellbore with a second liquid. The second liquid is preselected to provide a measure of control of the pressure within the annular volume as the fluid within the volume is being heated.

42 ENGINEERING↗

Controlling the pressure within an annular volume of a wellbore

A process is described for replacing at least a portion of the liquid within the annular volume of a casing system within a wellbore with a second liquid. The second liquid is preselected to provide a measure of control of the pressure within the annular volume as the fluid within the volume is being heated.

42 ENGINEERING↗

Computing and Visualizing Reachable Volumes for Maneuvering Satellites

Detecting and predicting maneuvering satellites is an important problem for Space Situational Awareness. The spatial envelope of all possible locations within reach of such a maneuvering satellite is known as the Reachable Volume (RV). As soon as custody of a satellite is lost, calculating the RV and its subsequent time evolution is a critical component in the rapid recovery of the satellite. In this paper, we present a Monte Carlo approach to computing the RV for a given object. Essentially, our approach samples all possible trajectories by randomizing thrust-vectors, thrust magnitudes and time of burn. At any given instance, the distribution of the 'point-cloud' of the virtual particles defines the RV. For short orbital time-scales, the temporal evolution of the point-cloud can result in complex, multi-reentrant manifolds. Visualization plays an important role in gaining insight and understanding into this complex and evolving manifold. In the second part of this paper, we focus on how to effectively visualize the large number of virtual trajectories and the computed RV. We present a real-time out-of-core rendering technique for visualizing the large number of virtual trajectories. We also examine different techniques for visualizing the computed volume of probability density distribution, including volume slicing, convex hull and isosurfacing. We compare and contrast these techniques in terms of computational cost and visualization effectiveness, and describe the main implementation issues encountered during our development process. Finally, we will present some of the results from our end-to-end system for computing and visualizing RVs using examples of maneuvering satellites.

97 MATHEMATICS AND COMPUTING↗

Microfluidic devices for the controlled manipulation of small volumes

A method for conducting a broad range of biochemical analyses or manipulations on a series of nano- to subnanoliter reaction volumes and an apparatus for carrying out the same are disclosed. The invention is implemented on a fluidic microchip to provide high serial throughput. In particular, the disclosed device is a microfabricated channel device that can manipulate nanoliter or subnanoliter reaction volumes in a controlled manner to produce results at rates of 1 to 10 Hz per channel. The reaction volumes are manipulated in serial fashion analogous to a digital shift register. The invention has application to such problems as screening molecular or cellular targets using single beads from split-synthesis combinatorial libraries, screening single cells for RNA or protein expression, genetic diagnostic screening at the single cell level, or performing single cell signal transduction studies.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ion Exchange and Solvent Extraction: Supramolecular Aspects of Solvent Exchange Volume 21

Preface The theme of supramolecular chemistry (SC), entailing the organization of multiple species through noncovalent interactions, has permeated virtually all aspects of chemical endeavor over the past several decades. Given that the observed behavior of discrete molecular species depends upon their weak interactions with one another and with matrix components, one would have to conclude that SC must indeed form part of the fabric of chemistry itself. A vast literature now serves to categorize SC phenomena within a body of consistent terminology. The word supramolecular itself appears in the titles of dozens of books, several journals, and a dedicated encyclopedia. Not surprisingly, the theme of SC also permeates the field of solvent extraction (SX), inspiring the framework for this volume of Ion Exchange and Solvent Extraction. It is attempted in the six chapters of this volume to identify both how supramolecular behavior occurs and is studied in the context of SX and how SC is influencing the current direction of SX. Researchers and practitioners have long dealt with supramolecular interactions in SX. Indeed, the use of polar extractant molecules in nonpolar media virtually assures that aggregative interactions will dominate the solution behavior of SX. Analytical chemists working in the 1930s to the 1950s with simple mono- and bidentate chelating ligands as extractants noted that extraction of metal ions obeyed complicated mass-action equilibria involving complex stoichiometries. As chemists and engineers developed processes for nuclear and hydrometallurgical applications in the 1950s and 1960s, the preference for aliphatic diluents only enhanced the complexity and supramolecular nature of extraction chemistry. Use of physical techniques such as light scattering and vapor-pressure measurements together with various spectroscopic methods revealed organic-phase aggregates from well-defined dimers to small aggregates containing a few extractant molecules to large inverse micelles swollen with water molecules. Extraction systems involving long-chain cations such as alkylammonium species or long-chain anions such as sulfonates or carboxylates proved especially prone to extensive aggregate formation. The related phenomenon of third-phase formation in SX systems, long misunderstood, is now yielding to spectroscopic and scattering techniques showing extensive long-range organization. Over the last 50 years, tools for studying the structure and thermodynamics of aggregation have grown increasingly sophisticated, leading to a rich and detailed understanding of what we can now recognize as SC phenomena in SX. In the 1970s and 1980s, the rapid growth of SC elicited a paradigm shift in SX. The influence of SC principles had two major effects on the course of SX research. First, it provided a framework for understanding the supramolecular behavior that was already well appreciated in the field of SX, though earlier without the SC terminology. Second, it provided the conceptual tools to control supramolecular behavior in SX, direct it for intended functionality, and to simplify it. Extraction by designed reagents has been steadily progressing ever since, with commercial applications emerging to successfully validate this approach. With the discovery of crown ethers in the late 1960s, the advancement of extractant design has fruitfully employed the concept of inclusion. While considerable initial progress occurred with such molecules, especially because of their affinity and selectivity for alkali and alkaline earth metals, other molecular platforms such as calixarenes have proven more versatile. Multidentate receptors for partial to full inclusion of cations, anions, ion pairs, as well as neutral species, have now become commonplace for selective extraction. This volume of Ion Exchange and Solvent Extraction examines how the principles of SC are being employed both in advancing the design of new highly selective SX systems and in understanding aggregation phenomena in SX systems. Chapter 1 discusses the nature and definition of SC and how it is used generally in design of novel SX reagents. Major approaches using SC principles are outlined and illustrated. Chapter 2 expands upon the theme of ion-pair recognition and introduces outer-sphere recognition of metal complexes, a novel idea with the potential for structural control of solvation, casting a new light on solvent modifiers. Chapter 3 reviews the large literature of calixarenes as extraction reagents for metal ions, where the synthetic versatility of this family of compounds has produced vast possibilities for inclusion and selective separations. Chapter 4 extends such chemistry to extraction of biomolecules, where the potential for selective separations is only beginning to be explored through site recognition in macromolecules. In Chapter 5, a detailed examination of the liquid-liquid interface as an expression of supramolecular phenomena i...

Gloe, Karsten↗

Systems and methods for the detection of low-level harmful substances in a large volume of fluid

A method and device for the detection of low-level harmful substances in a large volume of fluid comprising using a concentrator system to produce a retentate and analyzing the retentate for the presence of at least one harmful substance. The concentrator system performs a method comprising pumping at least 10 liters of fluid from a sample source through a filter. While pumping, the concentrator system diverts retentate from the filter into a container. The concentrator system also recirculates at least part of the retentate in the container again through the filter. The concentrator system controls the speed of the pump with a control system thereby maintaining a fluid pressure less than 25 psi during the pumping of the fluid; monitors the quantity of retentate within the container with a control system, and maintains a reduced volume level of retentate and a target volume of retentate.

47 OTHER INSTRUMENTATION↗

Single-Volume Neutron Scatter Camera for High-Efficiency Neutron Imaging and Spectroscopy

Neutron detection provides an effective method to detect, locate, and characterize sources of interest to nuclear security applications. Current neutron imaging systems based on double-scatter kinematic reconstruction provide good signal vs. background discrimination and spectral capability, but suffer from poor sensitivity due to geometrical constraints. This weakness can be overcome if both neutron-proton scattering interactions are detected and resolved within one large contiguous active detector volume. We describe here a maximum likelihood approach to event reconstruction in a single-volume system with no optical segmentation and sensitivity to individual optical photons on the surfaces of the scintillator. We present results from a Geant4-based simulation establishing the feasibility of this single-volume neutron scatter camera concept given notional performance of existing photodetector and readout technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupled Approximation of U.S. Driving Speed and Volume Statistics Using Spatial Conflation and Temporal Disaggregation

The advent of mobile devices with embedded global positioning systems has allowed commercial providers of real-time traffic data to develop highly accurate estimates of network-level vehicle speeds. Traffic speed data have far outpaced the availability and accuracy of real-time traffic volume information. Limited to a relatively small number of permanent and temporary traffic counters in any city, traffic volumes typically only cover a handful of roadways with inconsistent temporal resolution. This work addressed this data gap by coupling a commercial dataset of typical traffic speeds (by roadway and time of week) from TomTom to the U.S. FHWA's Highway Performance Monitoring System database of annual average daily traffic (AADT) counts by roadway. This work is technically novel in its solution for establishing a national crosswalk between independent network geometries using spatial conflation and big data techniques. The resulting product is a national dataset providing traffic speed and volume estimates under typical conditions for all U.S. roadways with AADT values.

30 DIRECT ENERGY CONVERSION↗

Acoustic gas volume fraction measurement in a multiphase flowing liquid

Apparatus and methods for the measurement of gas volume fraction of produced oil are described. A first method measures the response of a pipe containing the produced oil excited by a source of vibration in the form of an acoustic frequency chirp containing a linearly varying range of frequencies in the tens of kilohertz range encompassing at least one resonant mode of the pipe. As the gas volume fraction increases, the location of the peak maximum of the measured frequency spectrum responsive to the excitation increases in frequency, and the height of the peak maximum increases, thereby permitting a linear calibration curve to be obtained. A second method measures the response of a pipe containing the produced oil to excitation by a continuous source of vibration having a chosen frequency above those which excite flexural vibrations in the pipe and simultaneously excite acoustic waves in the fluid contained in the pipe, known as the coincidence frequency. Gas present in the fluid will interrupt sound propagation or reverberation, thereby generating fluctuations in the amplitude of the measured vibrations of the pipe. The amplitude fluctuation level provides a measure of the gas volume present inside the pipe. A third method measures the response of a pipe containing the produced oil to excitation by a high-bandwidth, short pulse having a chosen center frequency above the coincidence frequency. Gas present in the fluid will interrupt pulse propagation, thereby generating fluctuations in the amplitude of the measured vibrations of the pipe.

Sinha, Dipen N.↗

Beamline Volume Relief Analysis for the PIP-II SSR2 Cryomodule at Fermilab

The beam volume of the Pre-Production Single Spoke Resonator type 2 (ppSSR2) cryomodule [1] for the Proton Improvement Plan-II (PIP-II) [2] project will be protected against over-pressurization using a burst disk. This contribution focuses on the analysis of the relief of such trapped volume during a catastrophic scenario with multiple systems failures. An analytical model, able to predict the pressure in the beam volume depending of the various boundary conditions, has been developed and will be presented along with the results.

43 PARTICLE ACCELERATORS↗

High Energy Performance Tests of Large Volume LaBr{sub 3}:Ce Detector

High energy prompt gamma ray tests of a large volume cylindrical 100 mm x 100 mm (height x diameter) LaBr{sub 3}:Ce detector were carried out using a portable neutron generator-based Prompt Gamma Neutron Activation Analysis (PGNAA) setup. In this study prompt gamma-rays yield were measured from water samples contaminated with toxic elements such nickel, chromium and mercury compounds with gamma ray energies up to 10 MeV. The experimental yield of prompt gamma-rays from toxic elements were compared with the results of Monte Carlo calculations. In spite of its higher intrinsic background due to its larger volume, an excellent agreement between the experimental and calculated yields of high energy gamma-rays from Ni, Cr and Hg samples has been achieved for the large volume LaBr{sub 3}:Ce detector. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the initial and volume recombination losses in gamma versatile cylindrical ionization chamber VGIC developed for gamma ray dosimetry

A versatile Gamma ionization chambers are used for flow control in systems with gamma nuclear reactors and reprocessing plants in and monitoring atmosphere around these facilities, this in order to protect staff. In the Laboratory Detection and Measures (LDM) Division for Study and Development of Nuclear Instrumentation (DSDNI) of CRNB, we designed, developed and characterized a versatile gamma ionization chamber (VGIC) to study experimentally its characteristics according to the geometry of the electrodes, the volume and pressure of the filler gas for the design of a gamma sealed chamber. The tests were conducted under the IEC (International Electro-technical Commission). In this paper, we present the results obtained in the various nuclear tests for characterization and calibration that we have made on the ionization chamber gamma VGIC prototype developed at our Department. To do this, three irradiators were operated at the Laboratory Calibration (SSDL) of the Department of Medical Physics Nuclear Research Center of Algiers (CRNA). Irradiator intensive gamma ({sup 60}Co: 1.25 MeV), one medium intensity gamma ({sup 137}Cs: 0.662 MeV) and 3rd low intensity ({sup 60}Co). Saturation curves and linearity were identified and the operating range and the sensitivity of the chamber have been deducted. The (I,V) characteristics of the chamber filled, with argon gas at 3 bar (0.3 M pa) pressure, for gamma ray irradiator sources were studied. To do so, the chamber was irradiated with gamma rays using different numbers of gamma sources (i.e. Up to 5). The plateau region is reached above 200 V and the detector operating voltage is found to be 600 V. It is observed that in the plateau region the slope is constant with an increase in the exposure rate. The (1/I, 1/V) and (I, l/V{sup 2}) characteristic curves reveal the presence of the initial and volume recombination losses. The volume recombination losses are found to be smaller than the initial recombination losses. Finally, in order to strengthen our results, we performed in the same conditions, a comparative characterization with another ionization gamma chamber type reference LND 504 (USA). (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Finite Volume Method Based Neutronic Solvers for Steady and Transient Analysis of Molten Salt Reactors

In recent years, the coupled neutronics and thermal hydraulics analysis becomes more and more important, because it helps to identify the most relevant safety issues without conservative assumptions. In addition, such coupled simulations are essential for the generation IV advanced nuclear power systems such as molten salt reactor (MSR), because the presence of strong coupling between different phenomena, like the transport of delayed neutron precursors by the fluid flow?. Due to the different discretization methods used in reactor physics analysis and thermal-hydraulics analysis, it is hard to couple different kinds of codes. This work presents an attempt to solve the multigroup neutron diffusion equation with the finite volume method which is quite widely used for the numerical simulation of a variety of applications involving fluid flow and heat and mass transfer. The unstructured finite volume method (FVM) based on open source C++ library OpenFOAM was chosen as the development platform?. The objective of this paper is to concisely present the main features of the developed codes in terms of the theoretical background and numerical approach and as can be seen in the following sections, the calculation results obtained by the NDSFoam which solves the steady-state neutron diffusion equation and NDTFoam which solves the transient-state neutron diffusion equation are discussed and compared to the benchmark problems. In this paper, two new neutronic solvers using finite volume method have been developed to perform the neutron physics analysis. The solvers are based on OpenFOAM, and have been tested with several steady state and transient-state benchmark problems. By verifications of the codes, it is proved that the development of NDSFoam and NDTFoam are correct. In our future work, both of these two solvers will be coupled with the precompiled CFD solvers in OpenFOAM to analyze the molten salt fast reactors. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Large Volume Airborne Contamination Monitoring To Support Nuclear Processes' Deactivation and Decommissioning

Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measuring representative volume elements from high-resolution grain-scale strain fields

Most crystalline materials present a highly heterogeneous response at the microscale, which can be affected by both internal factors (such as microstructural parameters) and external factors (such as loading). Relating microscale inhomogeneities to the macroscale response of a material requires the use of homogenisation techniques, usually based on the concept of a representative volume element (RVE)—the smallest volume of material that represents the global average response. Here, in this work, we present a new and robust experimental method of measuring the size of a strain-based RVE from high-resolution grain-scale strain fields obtained using digital image correlation (DIC). The proposed method is based on the statistical (stereological) nature of the RVE, which has been widely adopted in numerical studies, and involves dividing a strain field into randomly selected regions of varying sizes and statistically analysing the distributions of average strains within them. To validate the new method, we generate a large number of synthetic strain fields from a fractional Gaussian noise algorithm. The proposed stereological method is shown to be capable of producing reliable RVE measurements from a very large range of possible microscale strain fields while at the same time being robust in that it can produce RVE measurement results even in cases where other existing methods may be unable to do so. The proposed method has a low field-of-view requirement, only needing a field-of-view about 1.2 times as large as the RVE to produce reliable measurements. In addition, the stereological method offers significant flexibility since its statistical nature allows for control over how strict the RVE measurement should be in each case.

36 MATERIALS SCIENCE↗