Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ULTRASOUND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Rationale for a 'Male Lumpectomy,' a Prostate Cancer Targeted Approach Using Cryoablation: Results in 21 Patients with at Least 2 Years of Follow-Up

Background. Prostate cancer in men raises many of the same issues that breast cancer does in women. Complications of prostate cancer treatment, including impotence and incontinence, affect the self-image and psyche of a man no less than does the loss of a breast in a woman. We present a pilot study in which 21 patients were treated with a focal cryoablation procedure. Methods. Focal cryoablation was performed using biplane transrectal ultrasound if the tumor was confined to only one prostate lobe. Preoperative PSA values were recorded. Cryoablation was planned to encompass the area of known tumor. PSA values were obtained every 3 months for 2 years and every 6 months thereafter. Potency and continence status was obtained at the same intervals. Routine biopsy was obtained at 1 year. Results. Twenty-one patients had focal cryoablation. Follow-up ranged from 24 to 105 months with a mean of 50 months. Twenty of 21 (95%) patients have stable PSA values with no evidence for cancer, despite 10 patients being at medium to high risk for recurrence. All patients biopsied (n = 19) were negative for tumor. Potency was maintained in 17 of 21 patients (80%). No other complications, including incontinence or fistula formation, were noted. Conclusion. These preliminary results indicate a 'male lumpectomy,' in which the prostate tumor region itself is destroyed, appears to preserve potency in a majority of patients and limits other complications, without compromising cancer control. If these results are confirmed by further studies and long-term follow-up, this treatment approach could have a profound effect on prostate cancer management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Hemoptysis by Abnormal Systemic Pulmonary Artery Supply

We report the case of a 29-year-old man with hemoptysis. The patient came to the emergency department, where a laboratory test and chest radiograph were reported as normal. The following day the patient again had hemoptysis, though less than previously. He reported no chest pain, dyspnea, fever, catarrh, changes in urine or feces, contact with patients with bacillus disease or constitutional symptoms. Doppler ultrasound of the chest showed right basal parenchymatous condensation containing a vessel with arterial flow (in the opposite direction to the aortic flow) compatible with an aberrant vessel, possibly a sequestration, leaving the aorta above the celiac trunk. Because of the findings of the chest echogram and magnetic resonance study, thoracoabdominal computed tomography angiography was undertaken; this showed right basal condensation and an anomalous vessel originating 1 cm above the celiac trunk, supplying the right lower lobe. An aortic and pulmonary arteriogram via an arterial and right femoral vein approach confirmed the findings. The patient was treated successfully with percutaneous embolization with coils. The relevant literature is reviewed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes After Unilateral Uterine Artery Embolization: A Retrospective Review

Purpose. Bilateral uterine artery embolization (UAE) is considered necessary to provide effective treatment for symptomatic uterine fibroids. Occasionally, only unilateral embolization is performed, and this study evaluates these outcomes. Materials and Methods. As part of a prospective observational study of more than 1600 patients treated with UAE since 1996, there have been 48 patients in whom unilateral embolization has been performed. This study retrospectively reviews clinical response as assessed by our standard questionnaire and radiological response assessed by either magnetic resonance imaging or ultrasound. Results. Two principal groups emerged: the largest, where only the dominant unilateral arterial supply was electively embolized (30 patients); and the second, where there was technical failure to catheterize the second uterine artery as a result of anatomical constraints (12 patients). Favorable clinical response with a reduction in menorrhagia at 1 year was seen in 85.7% (18/21) of those patients with a dominant arterial supply to the fibroid(s). In contrast, in those patients where there was technical failure to embolize one uterine artery, there was a high rate of clinical failure requiring further intervention in 58.3% (7/12). Comparison of the technical failure group with the dominant uterine artery group demonstrated a statistically significant (Fisher's exact test) difference in the proportion of patients with evidence of persistent fibroid vascularity (p < 0.001) and requiring repeat intervention (p < 0.01). Conclusion. We conclude that unilateral UAE can achieve a positive clinical result in the group of patients where there is a dominant unilateral artery supplying the fibroid(s), in contrast to the poor results seen following technical failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Large Renal Artery Aneurysm Treated with Guglielmi Detachable Coils: Procedural and 4-Year Follow-up Results

A large aneurysm of the left renal artery was found incidentally during abdominal ultrasound in a 39-year-old woman with no medical or family history of cardiovascular disease. Vascular pathology with a dysplastic appearance was confirmed by magnetic resonance angiography and the patient was offered transcatheter embolization. Since the position and size of the neck of the aneurysm could not be determined at angiography, detachable platinum coils were used for occlusion. The procedure was performed without complications. During a 4-year follow-up no alterations of renal function, recanalization of the aneurysm, or perfusion defects in the rest of the left renal circulation were noted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Primary Cutting Balloon Angioplasty for Treatment of Venous Stenoses in Native Hemodialysis Fistulas: Long-Term Results from Three Centers

Aim. To evaluate the technical success and patency rates following primary cutting balloon angioplasty for venous stenoses in native dialysis fistulas. Methods. Forty-one patients (26 men, 15 women; age range 26-82 years, average age 59 years) underwent 50 (repeat procedures in 9 patients) primary cutting balloon (PCB) angioplasty procedures in three institutions by three primary operators. The indication was primary stenosis in 21 patients, recurrent lesions in 15, and immature fistulas in 5. A PCB was used alone in 17 cases, but was followed by a larger standard balloon in 33 cases. Follow-up included ultrasound, flow analysis and urea reduction ratio, and ranged from 2 to 30 months (mean 14 months). Results. The technical success rate was 98%. All procedures were relatively painless. Two PCBs burst and 4 leaked, but without causing any morbidity. Nineteen fistulas were still working at last follow-up. Primary patency rates at 6, 12, and 24 months using Kaplan-Meier analysis were 88%, 73%, and 34%, respectively, and the primary assisted patencies were 90%, 75%, and 50%, respectively. Conclusion. PCB angioplasty has high technical success and low complication rates. The long-term patency rates are favorable for PCB angioplasty and compare favorably with other series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chronic Contained Rupture of an Abdominal Aortic Aneurysm: From Diagnosis to Endovascular Resolution

A male patient, 69 years old, presented with fever, leucocytosis, and persistent low back pain; he also had an abdominal aortic aneurysm (AAA), as previously diagnosed by Doppler UltraSound (US), and was admitted to our hospital. On multislice computed tomography (msCT), a large abdominal mass having no definite border and involving the aorta and both of the psoas muscles was seen. This mass involved the forth-lumbar vertebra with lysis, thus simulating AAA rupture into a paraspinal collection; it was initially considered a paraspinal abscess. After magnetic resonance imaging examination and culture of the fluid aspirated from the mass, no infective organisms were found; therefore, a diagnosisof chronically contained AAA rupture was made, and an aortic endoprosthesis was subsequently implanted. The patient was discharged with decreased lumbar pain. At 12-month follow-up, no evidence of leakage was observed. To our knowledge, this is the first case of endoprosthesis implantation in a patient, who was a poor candidate for surgical intervention due to renal failure, leucocytosis and high fever, having a chronically contained AAA ruptured simulatingspodilodiscitis abscess. Appropriate diagnosis and therapy resolved potentially crippling pathology and avoided surgical graft-related complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interventional Management of Massive Hemothorax Due to Inadvertent Puncture of an Aberrant Right Subclavian Artery

We report a case of massive hemothorax due to inadvertent puncture of an aberrant right subclavian artery during central venous access. Iatrogenic laceration at the origin of the right internal thoracic artery was successfully treated with coil embolization of the internal thoracic artery followed by stent-graft placement into the subclavian artery. Due to its elongated and abnormal course, an aberrant right subclavian artery may predispose to inadvertent puncture during vein catheterization and should be recognized as a potential threat for such procedures. Our case emphasizes that ultrasound guidance should be used routinely for central venous lines wherever possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Balloon Angioplasty Optimization: Should We Measure Balloon Volume As Well As Pressure?

Purpose. To investigate the influence that measurement of balloon volume as a controlled variable in addition to balloon pressure has on the outcome of balloon angioplasty in an experimental model. Methods. One hundred and three segments of explanted normal porcine carotid arteries were obtained. Five were used as controls, and the remaining 98 were subjected to balloon angioplasty with simultaneous measurement of balloon volume and pressure. These arteries were randomized into two groups. In one group the endpoint of the angioplasty was determined by balloon pressure (pressure-limited group, PLG) and in the other group by balloon volume (volume-limited group, VLG). Pressure/volume curves for each procedure were constructed by continuous measurement of both parameters by a purpose-designed computer-controlled inflation device. The diameter of each arterial segment was measured by intravascular ultrasound (IVUS) and the ratio of the inflated balloon to arterial diameter calculated. Arterial appearances after angioplasty were recorded using IVUS. Results. The balloon volumes measured at the endpoint of angioplasty were significantly smaller in the PLG compared with the VLG (p < 0.001). Three types of pressure/volume curves were identified: A, B, and C. In the type A curves, IVUS identified fissures in 28% (17/60) and the examination was normal in 72% (43/60). In the type B curves, IVUS identified fissures in 44% (4/9), dissections in 22% (2/9), and the examination was normal in 33% (3/9). In the type C curves, IVUS identified fissures in 44% (4/9) and dissection in 56% (5/9) with no normal examinations. In undamaged arterial segments a very high correlation was achieved between balloon volume and the balloon/artery ratio (Pearson correlation = -0.979, R{sup 2} = 0.957, p < 0.0001, n = 27). Conclusion. The measurement of pressure and volume during angioplasty enabled the construction of pressure/volume curves that showed deviations from the curves obtained in air. The balloon volume results, and significant deviation of the curve shape from the control curve shape, predicted vessel damage, which was confirmed by the IVUS appearance of the vessel after angioplasty. When pressure was used as the endpoint of balloon inflation the balloons were significantly underdilated compared with the manufacturer's nominal sizes. These data indicate that monitoring of pressure and volume during angioplasty may provide an alternative method of predicting vessel damage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Empyema and Effusion: Outcome of Image-Guided Small-Bore Catheter Drainage

Empyema and complicated pleural effusion represent common medical problems. Current treatment options are multiple. The purpose of this study was to access the outcome of image-guided, small-bore catheter drainage of empyema and effusion. We evaluated 93 small-bore catheters in 82 patients with pleural effusion (n = 30) or empyema (n = 52), over a 2-year period. Image guidance was with ultrasound (US; n = 56) and CT (n = 37). All patients were followed clinically, with catheter dwell times, catheter outcome, pleural fluid outcome, reinsertion rates, and need for urokinase or surgery recorded. Ninety-three small-bore chest drains (mean=10.2 Fr; range, 8.2-12.2 Fr) were inserted, with an average dwell time of 7.81 days for empyemas and 7.14 days for effusions (p > 0.05). Elective removal rates (73% empyema vs 86% effusions) and dislodgement rates (12% empyema vs 13% effusions) were similar for both groups. Eight percent of catheters became blocked and 17% necessitated reinsertion in empyemas, with no catheters blocked or requiring reinsertion in effusions (p < 0.05). Thirty-two patients (51%) required urokinase in the empyema group, versus 2 patients (6%) in the effusion group (p < 0.05). All treatment failures, requiring surgery, occurred in the empyema group (19%; n = 12; p < 0.05). In conclusion, noninfected pleural collections are adequately treated with small-bore catheters, however, empyemas have a failure rate of 19%. The threshold for using urokinase and larger-bore catheters should be low in empyema.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Factors Limiting Complete Tumor Ablation by Radiofrequency Ablation

The purpose of this study was to determine radiological or physical factors to predict the risk of residual mass or local recurrence of primary and secondary hepatic tumors treated by radiofrequency ablation (RFA). Eighty-two patients, with 146 lesions (80 hepatocellular carcinomas, 66 metastases), were treated by RFA. Morphological parameters of the lesions included size, location, number, ultrasound echogenicity, computed tomography density, and magnetic resonance signal intensity were obtained before and after treatment. Parameters of the generator were recorded during radiofrequency application. The recurrence-free group was statistically compared to the recurrence and residual mass groups on all these parameters. Twenty residual masses were detected. Twenty-nine lesions recurred after a mean follow-up of 18 months. Size was a predictive parameter. Patients' sex and age and the echogenicity and density of lesions were significantly different for the recurrence and residual mass groups compared to the recurrence-free group (p < 0.05). The presence of an enhanced ring on the magnetic resonance control was more frequent in the recurrence and residual mass groups. In the group of patients with residual lesions, analysis of physical parameters showed a significant increase (p < 0.05) in the time necessary for the temperature to rise. In conclusion, this study confirms risk factors of recurrence such as the size of the tumor and emphasizes other factors such as a posttreatment enhanced ring and an increase in the time necessary for the rise in temperature. These factors should be taken into consideration when performing RFA and during follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of the Viatorr Expanded Polytetrafluoroethylene-Covered Stent-Graft for Transjugular Intrahepatic Portosystemic Shunt Creation in Children: Initial Clinical Experience

Four children, three boys and one girl, with a median age of 9 years 8 months, underwent transjugular intrahepatic portosystemic shunt creation with an expanded polytetrafluoroethylene (e-PTFE)-covered nitinol stent. The stent-graft was successfully placed in all four patients without any complication. Clinical and biochemical improvement was noted in all four patients during follow-up. Radiological follow-up with use of duplex ultrasound showed a recurrent stenosis of the shunt 180 days after stent-graft implantation in one patient. This was treated with placement of an additional stent-graft, re-expanding completely the recurrent stenosis. In the other three patients, the stent-graft remained fully patent until the end of the study or until orthotopic liver transplantation. These preliminary results suggest that use of the Viatorr ePTFE-covered stent-graft in children is safe and feasible, with potentially the same high patency rate and improved clinical outcome as reported in adult patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-Expandable Stent Placement in Infrapopliteal Arteries After Unsuccessful Angioplasty Failure: One-Year Follow-up

The purpose of this prospective study was to evaluate whether stent placement in infrapopliteal arteries is helpful in failed percutaneous transluminal angioplasty (PTA). Infrapopliteal PTA was performed in 70 arteries of 66 patients with chronic critical lower limb ischemia. The group comprised 55 males and 11 females, with an average age of 63.4 (range, 42-82) years. Diabetes mellitus was present in 92.4% of patients. Only the palpable anterior tibial and posterior tibial arteries were evaluated. Stents (Xpert stent; Abbot Vascular, Redwood City, CA, USA) were placed in 16 arteries where PTA was not successful (the failure was defined as residual stenosis >30% after PTA). In 54 arteries simple PTA was performed and was technically successful. Twenty-four nondilated arteries with no significant stenosis served as a comparison group. The 12-month patency rate was evaluated according to a combination of palpation and Doppler ultrasound. In all cases stent placement restored the flow in the artery immediately after unsuccessful PTA. Twelve-month follow-up showed a patency rate of 82% in the PTA group, 78% in the stent group, and 69% in the comparison group. We conclude that stent placement in the case of unsuccessful infrapopliteal PTA changed technical failure to success and restored flow in the dilated artery. At 12-month follow-up the patency rate of infrapopliteal arteries stented for PTA failure did not differ significantly either from nonstented arteries with an optimal PTA result or from a comparison group of nonintervened arteries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Popliteal Venous Aneurysm: A Rare Cause of Recurrent Pulmonary Emboli and Limb Swelling

Popliteal venous aneurysm is a rare cause of recurrent pulmonary embolism, although the true incidence of aneurysm is probably underestimated. One-third of patients suffer further embolic events despite therapeutic anticoagulation. We report the case of a 59-year-old male who presented with recurrent PEs over a period of 12 years despite anticoagulation therapy. A thrombophilia screen and abdominal ultrasound were normal at that time. He reattended with recurrent pulmonary emboli, left calf swelling, and a mass in his left popliteal fossa causing limitation of knee movement. Venous duplex and MRI of his popliteal fossa demonstrated a thrombosed true popliteal venous aneurysm with popliteal and superficial femoral vein occlusion. In view of the mass effect we proceeded to surgical excision of his aneurysm after prophylactic placement of an IVC filter. The patient regained normal knee function with intensive inpatient physiotherapy. He has been recommenced on lifelong anticoagulant. The presentation, investigation, and management of the condition are briefly discussed. We suggest that a bilateral lower limb duplex is performed to exclude venous aneurysm in all patients presenting with pulmonary embolism in which an underlying source cannot otherwise be identified and no thrombophilic tendency is detected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Central Retinal and Posterior Ciliary Artery Occlusion After Intralesional Injection of Sclerosant to Glabellar Subcutaneous Hemangioma

The aim of this study is to describe vision loss caused by central retinal artery and posterior ciliary artery occlusion as a consequence of sclerotherapy with a polidocanol injection to a glabellar hemangioma. An 18-year-old man underwent direct injection with a 23-gauge needle of 1 mL of a polidocanol-carbon dioxide emulsion into the glabellar subcutaneous hemangioma under ultrasound visualization of the needle tip by radiologists. He developed lid swelling the next day, and 3 days later at referral, the visual acuity in the left eye was no light perception. Funduscopy revealed central retinal artery occlusion and fluorescein angiography disclosed no perfusion at all in the left fundus, indicating concurrent posterior ciliary artery occlusion. The patient also showed mydriasis, blepharoptosis, and total external ophthalmoplegia on the left side. Magnetic resonance imaging demonstrated the swollen medial rectus muscle. In a month, blepharoptosis and ophthalmoplegia resolved but the visual acuity remained no light perception. Sclerosing therapy for facial hemangioma may develop a severe complication such as permanent visual loss.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous RF Thermal Ablation of Renal Tumors: Is US Guidance Really Less Favorable Than Other Imaging Guidance Techniques?

The purpose of this study was to compare our experience with ultrasound (US)-guided percutaneous radiofrequency thermal ablation (RFA) of renal tumors with results of CT-guided and MRI-guided series in the current literature. Of 90 consecutive renal tumors treated with RFA in 71 patients, 87 lesions were ablated under US guidance. We performed a retrospective analysis of clinical outcome and safety. Results were then compared to published case series where CT and MRI guidances were used exclusively. In our series we had a major complication rate of 4.6%, whereas in CT- and MRI-based series it was 0-12% (mean, 2.2%) and 0-8.3% (mean, 4.1%), respectively. During follow-up (1-68 months; mean, 24 months) technical effectiveness was 89.7%, while it was between 89.5% and 96% in CT-guided series and between 91.7% and 100% in MRI-guided series. The size of successfully treated lesions (28 mm) was lower than that of partially-ablated lesions (36 mm; p = 0.004) and only central lesion location proved to be a negative prognostic factor (p = 0.009); in CT-guided series, positive prognostic factors were exophytic growth and size {<=}3 cm. 'Tumor-specific' 2-year survival was 92% in our series, 90-96% in CT-guided series, and not reported in MRI-guided series. In conclusion, despite common beliefs, US guidance in RFA of renal tumors is not less favorable than other guidance techniques. Thus the interventional radiologist can choose his or her preferred technique taking into account personal experience and available equipment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Angiographic Evaluation of Carotid Artery Grafting with Prefabricated Small-Diameter, Small-Intestinal Submucosa Grafts in Sheep

The purpose of this study was to report the longitudinal angiographic evaluation of prefabricated lyophilized small-intestinal submucosa (SIS) grafts placed in ovine carotid arteries and to demonstrate a variety of complications that developed. A total of 24 grafts, 10 cm long and 6 mm in diameter, were placed surgically as interposition grafts. Graft patency at 1 week was evaluated by Doppler ultrasound, and angiography was used for follow-up at 1 month and at 3 to 4 months. A 90% patency rate was found at 1 week, 65% at 1 month, and 30% at 3 to 4 months. On the patent grafts, angiography demonstrated a variety of changes, such as anastomotic stenoses, graft diffuse dilations and dissections, and aneurysm formation. These findings have not been previously demonstrated angiographically by other investigators reporting results with small-diameter vessel grafts made from fresh small-intestinal submucosa (SIS). The complications found were partially related to the graft construction from four SIS layers. Detailed longitudinal angiographic study should become an essential part of any future evaluation of small-vessel SIS grafting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency Ablation Assisted by Real-Time Virtual Sonography and CT for Hepatocellular Carcinoma Undetectable by Conventional Sonography

Real-time virtual sonography (RVS) is a diagnostic imaging support system, which provides the same cross-sectional multiplanar reconstruction images as ultrasound images on the same monitor screen in real time. The purpose of this study was to evaluate radiofrequency ablation (RFA) assisted by RVS and CT for hepatocellular carcinoma (HCC) undetectable with conventional sonography. Subjects were 20 patients with 20 HCC nodules not detected by conventional sonography but detectable by CT or MRI. All patients had hepatitis C-induced liver cirrhosis; there were 13 males and 7 females aged 55-81 years (mean, 69.3 years). RFA was performed in the CT room, and the tumor was punctured with the assistance of RVS. CT was performed immediately after puncture, and ablation was performed after confirming that the needle had been inserted into the tumor precisely. The mean number of punctures and success rates of the first puncture were evaluated. Treatment effects were evaluated with dynamic CT every 3 months after RFA. RFA was technically feasible and local tumor control was achieved in all patients. The mean number of punctures was 1.1, and the success rate of the first puncture was 90.0%. This method enabled safe ablation without complications. The mean follow-up period was 13.5 month (range, 9-18 months). No local recurrence was observed at the follow-up points. In conclusion, RFA assisted by RVS and CT is a safe and efficacious method of treatment for HCC undetectable by conventional sonography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗