Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transducers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Transmitters for animals and methods for transmitting from animals

Animal transmitters are provided that can include: a transducer configured to transmit a signal; process circuitry coupled to the transducer; and an energy harvesting element coupled to the process circuitry. Animals having a transmitter coupled thereto are also provided with the transmitter including an energy harvesting element in operational alignment with the animal's musculoskeletal system. Methods for transmitting the location of an animal are also provided with the methods including: coupling a transmitter powered by an energy harvesting element to the animal; and monitoring the transmissions of the transmitter.

Deng, Z. Daniel↗

Aquatic organism tracking devices, systems and associated methods

Aquatic organism tracking devices, systems and associated methods are described. According to one aspect, an aquatic organism tracking device includes a housing, a transducer coupled with the housing and configured to transmit a data transmission externally of the housing and an aquatic organism associated with the tracking device, a programmable oscillator coupled with the housing, and wherein the programmable oscillator is configured to generate a clock signal having a selected one of a plurality of different frequencies, processing circuitry coupled with the housing and configured to receive the clock signal from the programmable oscillator and to execute a plurality of executable instructions according to the clock signal, a power source coupled with the housing and configured to store electrical energy, and wherein the processing circuitry is configured to control the provision of the electrical energy from the power source to the transducer to generate the data transmission as a result of the execution of the instructions.

Deng, Z. Daniel↗

Status of Research Activities on LVDTs: Modeling and Simulation Development and Performance Characterization of Commercial LVDTs

FY-22 research focused on two major areas. The first area was modeling and simulation with linked testing that will advance the Linear Variable Differential Transformers (LVDT) technology for use by stakeholders requiring LVDTs in upcoming irradiation tests. The second area focused on testing LVDTs purchased from U.S. suppliers that were investigated in FY-21. These cross-cutting development activities will ensure stakeholders have the current state-of-the-art LVDT-based technologies for deployment in future irradiation tests. Two stand-alone reports are included in the appendixes. The purpose of this report is to provide a convenient body of work to access the reports and to evaluate the data and conclusions provided. Appendix A, “Testing of the RDP Translation Transducer,” contains a complete evaluation of an RDP Electrosense linear transducer that has the capability of replicating the form, fit, and function of LVDTs currently being used at Idaho National Laboratory (INL). Appendix B is an extract from the report, “Advanced Sensors and Instrumentation Program at Boise State University (BSU), August 2022, Linear Variable Differential Transformers.” This report contains modeling and testing results conducted at BSU and INL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods of transfection using sonoporation

The present invention relates to methods of transforming a cell by use of an acoustic transducer. In particular embodiments, the radiofrequency signal to the transducer can be tuned to provide optimal membrane disruption of the cell; and an agent, such as a nucleic acid, can then be delivered to the cell.

Ruffing, Anne↗

Evaluating the Feasibility of Measuring and Analyzing Strain Caused by Changes in Barometric Pressure in the Vadose Zone

Changes in barometric pressure propagate into the subsurface where they can affect water level measurements in wells and cause vertical strain. Previous strain sensors were developed to measure vertical strain, but they were limited to measurements at a single depth, making it difficult to evaluate strains from a migrating pressure wave. Technology known as Coherence-length-gated Microwave Photonics Interferometry (CMPI) uses optical fiber sensors to measure strain at multiple locations. It has the potential to detect strain caused by variations in barometric pressure at multiple depths in the subsurface. The goal of this study is to evaluate the feasibility of using this technology to record the changes in vertical strain in the vadose zone from small fluctuations in air pressure. Propagation of these air pressure fluctuations is affected by hydrogeological properties such as water content and permeability. A second goal of this study is to evaluate how these properties affect the air pressure distribution, strain, and gas-phase diffusivity with a long-term goal of using strain to monitor the vadose zone. The focus of this study is on a suite of laboratory experiments that used a sand-filled column with an open head space. The CMPI fiber was packaged and embedded along the axis of the column to measure the strain at multiple locations while air pressure transducers were installed through the wall of the column. Small periodic fluctuations in air pressure, similar to barometric pressure fluctuations, were created in the head space of the column using an audio driven speaker driven at 4 Hz using a sinusoidal signal created by a function generator. Then, the fluctuations propagated along the column where they were measured by the transducers and recorded as functions of time. Initial tests were conducted using dry sand, but then additional tests were conducted after injecting water into the column, which changed the hydrologic and mechanical properties. Another experiment was conducted after creating a thin barrier to air flow, which was designed to simulate a thin layer of saturated ground during rainfall. A final experiment was conducted by changing the grain size of the material to create a heterogeneity in the upper half of the column. The suite of six experiments was conducted to highlight effects of variations in water content and heterogeneities on air pressure and vertical strain. Numerical simulations were also created to evaluate the laboratory data and to provide a baseline analysis for the results. The numerical simulations used the governing equations to linear poroelasticity and two-phase flow with boundary conditions representing the experiments. The conceptual model for strain caused by barometric pressure recognizes that a fluctuating barometric pressure causes fluctuations in the air pore pressure that decrease in amplitude and lag in time with increase depth. The pressure distribution results in two different loads that cause strain: 1.) a mechanical load as the barometric pressure acts on the ground surface; and 2.) pressure loading in the pore space. The results show that the total vertical strain is a contribution of both of these loads, and this is the strain that was observed in the laboratory. The lab experiments show that both air pressure and strain vary as sinusoids that propagate with depth. The amplitude of the air pressure and strain decrease as a function of depth in all the conditions that were evaluate. For example, in the dry sand, the amplitude of the air pressure decreases from 25 Pa at the head space to 5 Pa at a depth of 70 cm, whereas the amplitude of the strain decreases from 0.15 to 0.06 µε over the same depth interval. In many cases the amplitudes decrease is approximately negative exponential functions of depth. When water was injected into the sand and the saturation increased, the amplitude of the air pressure increased in the partially saturated sand but decreased sharply to zero where the soil was saturated. The strain decreased with depth, but the transition from partially to fully saturated conditions had little effect on the strain profile, even though it had a major effect on the air pressure. This apparently is because strain is caused by variations in both water and air pressure. The fluctuating air pressure caused the water pressure to fluctuate, which caused strain throughout the column. Phase delay of the air pressure and the strain both increase as linear to bi-linear functions of depth. The phase delays indicate that pressure propagates at a velocity of 7 to 8 m/s in dry or partially saturated sand, but it drops by more than an order of magnitude in the vicinity of the capillary fringe. The phase delays indicate the strain propagates faster than the pressure. The data indicate that the strain propagates from 1.2 to more than 4x faster than the pressure. Switching from sand to silt in the column caused the velocity of the pressure to drop by roughly half for both pressures, but curiously, it had little effect on the velocity of the strain.

54 ENVIRONMENTAL SCIENCES↗

Experimental Investigation of Vapor Formation in Liquid CO2 Flow Through a Converging-Diverging Nozzle

Carbon dioxide is an attractive working fluid for many cycles, including for pumped thermal energy storage (PTES). A challenge with some proposed sCO2 PTES cycles is the operation of sCO2 machinery outside the typical bounds of experience, with local phase change from the liquid state being particularly unknown. Presently, there is insufficient data in the literature regarding multiphase CO2 to adequately design a multiphase-tolerant turbine, so generation of foundational data is required. This experimental study investigates the flow characteristics of sub-sonic liquid CO2 undergoing expansion and phase change in a converging-diverging nozzle. The nozzle is instrumented to measure static pressure, unsteady pressure, temperature, and density. The static pressure transducers are located at 27 axial locations to accurately characterize the pressure profile in the nozzle. High-accuracy RTDs are located at the entrance and exit of the nozzle, and three dynamic pressure transducers are strategically located to capture any unsteady phenomena. During testing, values of mass flow and nozzle inlet pressure are swept to vary the pressure drop and fluid properties. The measured total pressure drop in the nozzle is compared to a homogenous model and the Lockhart-Martinelli correlation method, with the latter predicting loss quite closely. The resulting data set is valuable for validating multiphase numerical models in a simple geometry before implementation of these models in turbomachinery design.

25 ENERGY STORAGE↗

Imaging of surface acoustic waves on GaAs using 2D confocal Raman microscopy and atomic force microscopy

Surface acoustic wave devices have been fabricated on a GaAs (100) substrate to demonstrate the capability of 2D Raman microscopy as an imaging technique for acoustic waves on the surface of a piezoelectric substrate. Surface acoustic waves are generated using a two-port interdigitated transducer platform, which is modified to produce surface standing waves. We have derived an analytical model to relate Raman peak broadening to the near-surface strain field of the GaAs surface produced by the surface acoustic waves. Additionally, atomic force microscopy is used to confirm the presence of a standing acoustic wave, resolving a total vertical displacement of 3 nm at the antinode of the standing wave. Stress calculations are performed for both imaging techniques and are in good agreement, demonstrating the potential of this Raman analysis.

47 OTHER INSTRUMENTATION↗

Generation of selective single-mode guided waves by d 36 type piezoelectric wafer

In general, mixed modes and dispersion of guided wave occur at any excitation frequency, while single modes are needed for effective nondestructive evaluation of structures. In this work, we present an approach to generate a selective single-mode guided wave in plate-like structures by exploiting the unique directionality of the d 36 type piezoelectric wafer and the symmetry of fundamental guided wave modes. Specifically, we devise a unified fundamental shear horizontal (SH 0 ) wave/fundamental antisymmetric mode (A 0 ) wave directional transducer pair by attaching the d 36 type piezoelectric wafers back to back on the opposite sides of the plate to provide selective, directional single-mode guided waves for actuation and sensing. Originally, the d 36 -type piezoelectric wafer, poled and cut from the lead magnesium niobate-lead titanate crystal, produces a mixture of the in-plane SH 0 (symmetric) mode and out-of-plane A 0 (asymmetric) and S 0 (symmetric) modes. By applying the in-phase or out-of-phase applied electrical field to the coupled d 36 -type piezoelectric wafer pair, our devised approach generates selective single modes, SH 0 or A 0 , respectively, to propagate in the structure. We describe the theoretical development of our approach and conduct both numerical simulations and laboratory experiments for validations.

42 ENGINEERING↗

Measuring thermal profiles in high explosives using neural networks

We present a new method for calculating the temperature profile of high explosive (HE) material using a Convolutional Neural Network (CNN). To train/test the CNN, we have developed a hybrid experiment/simulation method for collecting acoustic and temperature data. We experimentally heat cylindrical containers of HE material until detonation/deflagration, where we continuously measure the acoustic bursts through the HE using multiple acoustic transducers lined around the exterior container circumference. However, measuring the temperature profile in the HE in an experiment would require inserting a large number of thermal probes, which would disrupt the heating process. Thus, we use two thermal probes, one at the HE center and one at the wall. We then use numerical simulation of the heating process to calculate the temperature distribution and correct the simulated temperatures based on the experimental center and wall temperatures. We calculate temperature errors on the order of 15 °C, which is ∼12% of the range of temperatures in the experiment. We also investigate how the algorithm’s accuracy is affected by the number of acoustic receivers used to collect each measurement and the resolution of the temperature prediction. This work provides a means of assessing the safety status of HE material, which cannot be achieved using existing temperature measurement methods. In addition, it has implications for a range of other applications where internal temperature profile measurements would provide critical information. These applications include detecting chemical reactions, observing thermodynamic processes such as combustion, monitoring metal or plastic casting, determining the energy density in thermal storage capsules, and identifying abnormal battery operations.

97 MATHEMATICS AND COMPUTING↗

High-Cooperativity Coupling of Rare-Earth Spins to a Planar Superconducting Resonator

The interfacing of a superconducting microwave resonator with rare-earth-doped crystals presents a promising hybrid quantum system for applications including spin-assisted transducers and memories. The coupling strength between the spins of the rare-earth ions and the microwave photons is characterized by the cooperativity. Here, we report an ultrahigh cooperativity of C~650 between rare-earth spins and a planar superconducting microwave resonator that features a highly uniform magnetic field for harnessing the strong anisotropic coupling strength of erbium-doped yttrium orthosilicate. This cooperativity rivals that from a bulk dielectric resonator and may pave a path for efficient coupling of spins with microwave photons on an integrated platform.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Broadband, High Efficiency OMT in E-Band

A high-performance, broadband E-Band orthomode transducer (OMT) was designed and fabricated for a dedicated frequency converter. Cross-polarized signals between 71 and 86 GHz, received in a TE 11 mode circular waveguide needed to be split into separate horizontal and vertical polarization channels. The purpose of the OMT is to service the 71–76 and 81–86 GHz licensed communication bands. The main goal of OMT design is maximized transmission across the design bandwidth. Every fraction of a dB lost before the first low noise amplifier is a direct loss in SNR for the overall system. Several different design approaches were simulated, and several OMT’s and ancillary components were built and tested. In the end, practical limitations determined the final path of the completed device. The final product performed several tenths of a dB better than commercially available devices and better than most reported in academic literature. Lessons learned included which construction techniques worked and did not work, as well as what compromises are acceptable.

42 ENGINEERING↗

Optimizing Sensor Count and Placement to Detect Bond Wire Lift-Offs and Surface Defects in High-Power IGBT Modules Using Low-Cost Piezo-Electric Resonators

This manuscript presents the most recent results and findings to identify bond wire lift-offs and surface defects in high-power isolated gate bipolar junction transistor (IGBT) modules. The authors of this manuscript formerly proposed a low-cost, piezoelectric resonator-based measurement unit to detect bond wire related degradation in larger IGBT modules. Since high-power IGBT modules are expensive, it was apparent that evaluating our proposed method by inducing controlled damage to fresh (new) IGBTs may not be cost-effective especially when multiple sets of data need to be captured by inducing damage to different levels. In order to overcome this limitation, IGBT bond wires have been mimicked using a 3D printed enclosure, a PCB, and copper wires with dimensions very closely resembling a real IGBT. Using this method, multiple test devices can be built at the cost of a real IGBT, and the proposed technique could be fine-tuned without damaging expensive, real IGBTs. Our recent findings can be used to determine real IGBT degradation and bond wire lift-offs using only two sensors, as opposed to six transducers used in the first iteration of the setup. In addition to optimizing the sensor count, we have also identified the best possible locations of these sensors by attempting multiple placements inside the IGBT casing.

condition monitoring↗

Electronic Scanning Strategies in Adaptive Electrical Capacitance Volume Tomography: Tradeoffs and Prospects

Electrical Capacitance Volume Tomography (ECVT) has been applied for imaging of multiphase flows found in industrial applications. The ill-posed nature of the image reconstruction problem in ECVT and the consequent low resolution can be alleviated by employing electronic scanning enabled by electrode segmentation and reconfiguration during data acquisition. Here we study electronic scanning strategies that mimic physical rotation and shifting of the sensor along its symmetry axis. First, we study the feasibility of electronic scanning by analyzing the capacitance transducer circuit in SPICE. Then, we simulate electronic scanning using the finite element method for different electrode shapes, for which we compare the image reconstruction results and acquisition time. We find a noticeable improvement in image resolution for the scanning cases over conventional ECVT. Lastly, among the scanning cases, we emphasize a particular electrode shape that provides the best image resolution along with the minimal amount of acquisition time.

47 OTHER INSTRUMENTATION↗

Transmission of Images With Ultrasonic Elastic Shear Waves on a Metallic Pipe Using Amplitude Shift Keying Protocol

Transmission of information using ultrasonic elastic waves on existing metallic pipes provides an alternative communication option across physical barriers in a highly partitioned industrial complex, such as a nuclear facility. This work investigates the feasibility of the transmission of digital images over metallic pipes. Ultrasonic communication systems for transmission of images on a nuclear-grade stainless steel pipe were assembled for bench-scale demonstration. Information carriers in this system are refracted shear waves transmitted and received with piezoelectric transducers (PZTs) operating at 2-MHz nominal frequency. The refraction and propagation of ultrasonic shear waves were modeled with COMSOL software. An amplitude shift keying (ASK) communication protocol for image transmission was developed and implemented in the GNURadio software-defined radio (SDR) environment. Digital information was converted to analog ultrasonic signals using Red Pitaya electronic boards. The performance of the ASK protocol is evaluated at the output of every block in the GNURadio program by monitoring the transmission of select characters. Using the ASK communication protocol, the transmission of the 32-KB image was demonstrated at 2-Kbps bitrate across 6-ft-long stainless steel pipe. Finally, preliminary evaluation of ultrasonic communication on the piping of a nuclear facility, such as signal transmission on bent pipes, was performed with COMSOL computer simulations.

42 ENGINEERING↗

Utah FORGE: Pump and Probe Test on an Intact Westerly Granite Sample

This dataset contains results from a pump and probe experiment conducted on an intact Westerly Granite sample with a diameter of 1 inch and a height of 1 3/8 inches. The experiment was performed within an aluminum triaxial pressure vessel (TEMCO) to investigate the non-linear acoustic parameters of the sample under varying axial pressures. The confining pressure was maintained at 4 MPa, while the axial pressure was incrementally increased from 1 MPa to 17 MPa before being reduced back to 1 MPa. 5 dynamic pressure oscillations of 0.5 MPa were applied over a 10 minute interval. The dataset includes pump controller data, linear variable differential transformer (LVDT) measurements, and acoustic data. The pump controller data tracks the confining and axial pressures, flow rates, and pump volumes. LVDT measurements provide detailed records of the axial displacement of the cell piston. Additionally, acoustic data captured by s-wave transducers is archived in a compressed file.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Pump and Probe Test on a Mated Fracture Westerly Granite Sample

This dataset contains results from a pump and probe experiment conducted on a mated fracture Westerly Granite sample with a diameter of 1 inch and a height of 2 7/8 inches. The experiment was performed within an aluminum triaxial pressure vessel (TEMCO) to investigate the non-linear acoustic parameters of the sample under varying axial pressures. The confining pressure was maintained at 4 MPa, while the axial pressure was incrementally reduced from 17 MPa to 1 MPa in 1 MPa steps. 5 dynamic pressure oscillations of 0.5 MPa were applied over a 10 minute interval. The dataset includes pump controller data, linear variable differential transformer (LVDT) measurements, and acoustic data. The pump controller data tracks the confining and axial pressures, flow rates, and pump volumes. LVDT measurements provide detailed records of the axial displacement of the cell piston. Additionally, acoustic data captured by s-wave transducers is archived in a compressed file.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Direct Shear Test Data for Investigating Seismic Precursors to Shear Failure of Fractures

This dataset includes results of direct shear tests to investigate the mechanical and geophysical response of dry and saturated fractures in Indiana limestone and Sierra White granite. Direct shear tests were performed on tensile-induced fractures in Indiana limestone and Sierra White granite in a custom water-pressurized chamber. The provided Excel files include the representative seismic wave signals and the normalized wave amplitudes of ultrasonic wave transducers. A link to the published journal article presenting the data and describing the experiment in detail is provided as well.

15 GEOTHERMAL ENERGY↗