Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Testbed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Science Federation Emulation Testbed: Demonstration of VFSIE Functionalities

The Virtual Federated Science Instrument Environment (VFSIE) is a digital twin of a federated infrastructure of multiple sites with science instruments and computing systems that are geographically dispersed. It emulates the federation using containers and virtual hosts (vhosts) connected over local and wide-area networks for the main purpose of supporting the development and testing of science workflows and software stacks, which will subsequently transition to the physical infrastructure. In this demo, we present VFSIE of a four sites scenario and illustrate the following use cases: (i) execution of federation stack components that expose resources to enable a science user to execute workflows, (ii) execution of remote control commands of beam-line instruments to collect measurements and position the sensor, and (iii) remote execution and access of Jupyter Notebook for tomographic image computations

Al Najjar, Anees↗

An Integrated Testbed for Trojans in Printed Circuit Boards with Fuzzing Capabilities

This paper showcases an all-in-one testing environment that combines Trojan detection and fuzzing capabilities for printed circuit boards using the OpenPLC “NYU Trojan Edition” and a dedicated Trojan detection framework. The demo system is self-contained and equipped with two OpenPLC-based boards (one with a Trojan and one without), and automated tools for inserting the Trojan and collecting side-channel data. We developed a graphical user interface for interactive Trojan selection, data visualization, and anomaly detection analysis.

Trojan detection, anomaly detection, PCB, timing l↗

Vibration isolation for centrifuge testbeds

A method for isolating vibrations for centrifuge testing devices is provided. The method comprises coupling a test payload platform to a number of piezoelectric actuators and coupling the piezoelectric actuators to a reaction mass coupled to a centrifuge arm. A layer of vibration-absorbing material is sandwiched between the reaction mass and the centrifuge arm. The centrifuge arm is rotated around an axis, and the test payload platform is vibrated with the piezoelectric actuators as the centrifuge rotates, wherein the layer of vibration-absorbing material prevents vibrations from traveling down the centrifuge arm.

Siler, David Michael↗

Contaminant Transport Modeling for Technology Evaluation and Long-Term Monitoring in the Tims Branch Testbed, SC - 20343

Studies conducted at U.S. DOE sites have shown the presence of heavy metals, radionuclides, and volatile organic compounds in surface water, groundwater, and soil as a result of nuclear activity in the Cold War era. Since the 1990's, innovative cleanup methods have been implemented in the Tims Branch watershed at Savannah River Site (SRS) to limit the contaminant flux to the stream that have reduced the contaminant concentrations to acceptable regulatory levels in the dissolved phase. A tin-based treatment which effectively eliminated all local anthropogenic mercury inputs to this ecosystem resulted in a known step function addition of inert tin oxide particles which now serve as a potential tracer for sedimentation and particle transport processes in the stream. The long-term effectiveness of this and other remediation techniques and the potential for remobilization of adsorbed contaminant in sediment during extreme hydrologic conditions however remains unclear. It is therefore important to understand not only the fate and transport of dissolved contaminants, but also the movement of sediment and the relevant interactions with dissolved contaminant. To narrow this knowledge gap, a study is being conducted using the Tims Branch watershed as a stream-scale ecosystem test-bed to identify the primary transport processes of major contaminants of concern (such as mercury, nickel and uranium) with an emphasis on interactions with sediment transport. This involves the development of a fully distributed hydrologic watershed model of the Tims Branch watershed to predict streamflow under extreme weather conditions, as well as the development of a comprehensive contaminant transport model that can properly account for coupled contaminant and sediment transport. Review of relevant research reports and peer-reviewed journals revealed that aside from advection-dispersion transport of dissolved contaminants, adsorption and desorption with suspended solids and bed sediment also play an important role in the transport of those contaminants of concern. To develop the fully distributed hydrologic watershed model, the MIKE SHE 2-dimensional (2D) land surface/3D groundwater model that simulates surface/subsurface hydrologic processes (such as overland flow, evapotranspiration, and infiltration) was coupled with a 1D streamflow model that accounts for stream water hydraulics (such as hydraulic structures, cross-sections, and network). To model contaminant transport, the MIKE 11 streamflow component was coupled with the MIKE 11 AD module that simulates solute transport through advection and dispersion, and MIKE ECO Lab module that accounts for both sediment transport and interactions with dissolved contaminant. At this stage, the development and optimization of the fully distributed hydrologic model has been completed, achieving satisfactory statistical results between observed and predicted discharge as indicated by a root mean square error (RMSE) of 0.039 cms and a Nash-Sutcliffe efficiency coefficient (NSE) of 0.764. The ongoing development of the contaminant transport model has also yielded realistic results from preliminary tests. Results from this study are a key to evaluating the effectiveness of tin (II)-based mercury treatment of wetlands at the SRS site, and are also relevant to evaluating the potential of using this type of novel remediation technology in other mercury-contaminated stream systems. Knowledge acquired from this research will also support interpretation of historical data on the trends of contaminant concentration distribution in Tims Branch, particularly considering the effect of extreme hydrological events on the stream flow and pollutant transport. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Testbed for Pipeline Flushing - 20425

Pipelines which carry high-level waste within the DOE complex should be properly flushed in the cases where stationary or moving beds of solid sediment occur, or lines are prone to hydrogen gas buildup. Present guidelines establish a minimum for the amount of water (flush volume) and flush velocity values used for post-transfer flushing operations to achieve satisfactory cleaning of pipelines. However, further studies are needed to find optimal operating velocity modes/values in order to minimizing the flush volume and consequent downstream waste. These efforts are significantly helpful to DOE waste remediation sites by preserving tank storage, preventing additional waste processing, and minimizing dilution and changes in waste chemistry. An experimental test loop was recently developed for study of non-Newtonian slurry flushing at the Florida International University (FIU). This loop was designed to create sediment beds of various materials and bed heights and investigate parameters that effect the efficiency of flushing operations. The objective is to find flush velocity values/modes which lead to satisfactory cleaning of transport lines with a minimum amount of water usage. A 165 ft experimental test loop made of 3-inch carbon steel pipes was constructed and used in initial testing campaigns. This pipe loop was equipped with real-time monitoring instruments to record variation of pressure, density, mass flow rate, and temperature during testing. Post-flush in-situ no-flow evaluations were performed using ultrasonic, endoscopy, and visual inspection. Additional post-flush evaluations were conducted using filtration and density monitoring of residuals within a designated circulations loop. These provisions enable comparison of pipeline cleanness before the start and after termination of flushing operations for efficiency evaluation. This paper presents efforts associated with flushing of kaolin-water mixtures at different concentrations and with various flush volume and flush velocity values/modes. In initial testing, efforts focused on creating repeatable sediment beds inside the pipeline in both fully-flooded (no pre-flush drainage) and gravity-drained (pre-flush drained) systems. Bed characterization (i.e., measurement of sediment height and solids concentration) was conducted to ensure about consistency of initial conditions between tests. Preliminary results for flushing study of 10% vol. kaolin-water mixtures starting from a fully-flooded initial condition showed that flushing with 1-line volume (65 gallons) could remove up to 72 percent of solids from the pipeline. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗