Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Classical field approximation of ultralight dark matter: Quantum break times, corrections, and decoherence

The classical field approximation is widely used to better understand the predictions of ultralight dark matter. Here, in this work, we use the truncated Wigner approximation method to test the classical field approximation of ultralight dark matter. This method approximates a quantum state as an ensemble of independently evolving realizations drawn from its Wigner function. The method is highly parallelizable and allows the direct simulation of quantum corrections and decoherence times in systems many times larger than have been previously studied in reference to ultralight dark matter. Our study involves simulation of systems in 1, 2, and 3 spatial dimensions. We simulate three systems, the condensation of a Gaussian random field in three spatial dimensions, a stable collapsed object in three spatial dimensions, and the merging of two stable objects in two spatial dimensions. We study the quantum corrections to the classical field theory in each case. We find that quantum corrections grow exponentially during nonlinear growth with the timescale being approximately equal to the system dynamical time. In stable systems the corrections grow quadratically. We also find that the primary effect of quantum corrections is to reduce the amplitude of fluctuations on the de Broglie scale in the spatial density. Finally, we find that the timescale associated with decoherence due to gravitational coupling to baryonic matter is at least as fast as the quantum corrections due to gravitational interactions. These results are consistent with the predictions of the classical field theory being accurate.

79 ASTRONOMY AND ASTROPHYSICS↗

Rigid registration algorithm based on the minimization of the total variation of the difference map

Image registration is broadly used in various scenarios in which similar scenes in different images are to be aligned. However, image registration becomes challenging when the contrasts and backgrounds in the images are vastly different. This work proposes using the total variation of the difference map between two images (TVDM) as a dissimilarity metric in rigid registration. A method based on TVDM minimization is implemented for image rigid registration. The method is tested with both synthesized and real experimental data that have various noise and background conditions. The performance of the proposed method is compared with the results of other rigid registration methods. It is demonstrated that the proposed method is highly accurate and robust and outperforms other methods in all of the tests. The new algorithm provides a robust option for image registrations that are critical to many nano-scale X-ray imaging and microscopy applications.

36 MATERIALS SCIENCE↗

Correction for Metastability in the Quantification of PID in Thin-Film Module Testing

A fundamental change in the analysis for the accelerated stress testing of thin-film modules is proposed, whereby power changes due to metastability and other effects that may occur due to the thermal history are removed from the power measurement that we obtain as a function of the applied stress factor. In this work, initial thermal treatment of the module is performed before application of the independent variable stress of system voltage so that any temperature-dependent processes (e.g., diffusion) that affect the module power are largely activated beforehand. Secondly, the power of reference modules normalized to an initial state-undergoing the same thermal and light exposure history but without the applied stress factor such as humidity or voltage bias-is subtracted from that of the stressed modules. For better understanding and appropriate application in standardized tests, the method is demonstrated and discussed for potential-induced degradation testing in view of the paralleloccurring but unrelated physical mechanisms that can lead to confounding power changes in the module.

14 SOLAR ENERGY↗

The nth root percent depth dose method for calculating monitor units for irregularly shaped electron fields

This study outlines an improved method for calculating dose per monitor unit values for irregularly shaped electron fields using the nth root percent depth dose method. This method calculates the percent depth dose and output factors for an irregularly shaped electron field directly from the measured electron beam percent depth dose curves and output factors for circular fields. The percent depth dose curves and output factors for circular fields are normalized and measured at a fixed depth of maximum dose for a reference field, respectively. When compared with the sector integral lateral buildup ratio method, the percent depth dose data calculated using the nth root method accounts more accurately for the change in lateral scatter with decreasing field size. Therefore, it provides more accurate values of dose per monitor unit at different depths for all type of field shapes and beam energies. For beam energies in the range of 6-21 MeV, the differences between measured and calculated dose per monitor unit values, at different depths, were found to be within {+-}1.0% when the nth root percent depth dose method was used for calculation and 12.6% when the sector integral lateral buildup ratio method was used. The nth root percent depth dose method was tested and compared with the sector integral lateral buildup ratio method for ten clinically used irregularly shaped inserts (cutouts). For small irregularly shaped fields, a maximum difference of 2% was found between calculated dose per monitor unit values and measurements when the nth root percent depth dose method was used; this difference changed to 7% when comparisons were made between measurements and calculations based on the sector integral lateral buildup ration method. For large irregular fields this difference was found to be within 1.5% and 3.5%, respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reduction of ring artifacts in CBCT: Detection and correction of pixel gain variations in flat panel detectors

Purpose: In using flat panel detectors (FPD) for cone beam computed tomography (CBCT), pixel gain variations may lead to structured nonuniformities in projections and ring artifacts in CBCT images. Such gain variations can be caused by change in detector entrance exposure levels or beam hardening, and they are not accounted by conventional flat field correction methods. In this work, the authors presented a method to identify isolated pixel clusters that exhibit gain variations and proposed a pixel gain correction (PGC) method to suppress both beam hardening and exposure level dependent gain variations. Methods: To modulate both beam spectrum and entrance exposure, flood field FPD projections were acquired using beam filters with varying thicknesses. “Ideal” pixel values were estimated by performing polynomial fits in both raw and flat field corrected projections. Residuals were calculated by taking the difference between measured and ideal pixel values to identify clustered image and FPD artifacts in flat field corrected and raw images, respectively. To correct clustered image artifacts, the ratio of ideal to measured pixel values in filtered images were utilized as pixel-specific gain correction factors, referred as PGC method, and they were tabulated as a function of pixel value in a look-up table. Results: 0.035% of detector pixels lead to clustered image artifacts in flat field corrected projections, where 80% of these pixels were traced back and linked to artifacts in the FPD. The performance of PGC method was tested in variety of imaging conditions and phantoms. The PGC method reduced clustered image artifacts and fixed pattern noise in projections, and ring artifacts in CBCT images. Conclusions: Clustered projection image artifacts that lead to ring artifacts in CBCT can be better identified with our artifact detection approach. When compared to the conventional flat field correction method, the proposed PGC method enables characterization of nonlinear pixel gain variations as a function of change in x-ray spectrum and intensity. Hence, it can better suppress image artifacts due to beam hardening as well as artifacts that arise from detector entrance exposure variation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nuclear Fuels & Materials Spotlight Volume 4

As the nation's nuclear energy laboratory, Idaho National Laboratory brings together talented people and specialized nuclear research capability to accomplish our mission. This edition of the Nuclear Fuels and Materials Division Spotlight provides an overview of some of our recent accomplishments in research and capability development. These accomplishments include: • The first identification of silver and palladium migrating through the SiC layer in TRISO fuel • A description of irradiation assisted stress corrosion testing capabilities that support commercial light water reactor life extension • Results of high-temperature safety testing on coated particle fuels irradiated in the ATR • New methods for testing the integrity of irradiated plate-type reactor fuel • Description of a 'Smart Fuel' concept that wirelessly provides real time information about changes in nuclear fuel properties and operating conditions • Development and testing of ultrasonic transducers and real-time flux sensors for use inside reactor cores, and • An example of a capsule irradiation test. Throughout Spotlight, you'll find examples of productive partnerships with academia, industry, and government agencies that deliver high-impact outcomes. The work conducted at Idaho National Laboratory helps to spur innovation in nuclear energy applications that drive economic growth and energy security. We appreciate your interest in our work here at INL, and hope that you find this issue informative.

99 GENERAL AND MISCELLANEOUS↗

Aerosol-Assisted Solid Debris Collection for the National Ignition Facility

The National Ignition Facility (NIF) has been completed and has made its first shots on-target. While upcoming experiments will be focused on achieving ignition, a variety of subsequent experiments are planned for the facility, including measurement of cross sections, astrophysical measurements, and investigation of hydrodynamic instability in the target capsule. In order to successfully execute several of these planned experiments, the ability to collect solid debris following a NIF capsule shot will be required. The ability to collect and analyze solid debris generated in a shot at the National Ignition Facility (NIF) will greatly expand the number of nuclear reactions studied for diagnostic purposes. Currently, reactions are limited to only those producing noble gases for cryogenic collection and counting with the Radchem Apparatus for Gas Sampling (RAGS). The radchem solid collection diagnostic has already been identified by NIF to be valuable for the determination and understanding of mix generated in the target capsule's ablation. LLNL is currently developing this solid debris collection capability at NIF, and is in the stage of testing credible designs. Some of these designs explore the use of x-ray generated aerosols to assist in collection of solid debris. However, the variety of harsh experimental conditions this solid collection device will encounter in NIF are challenging to replicate. Experiments performed by Gary Grim et al. at Sandia National Laboratory's RHEPP1 facility have shown that ablation causes a cloud of material removed from an exposed surface to move normal to and away from the surface. This ablation is certain to be a concern in the NIF target chamber from the prompt x-rays, gamma rays, etc. generated in the shot. The cloud of ablated material could interfere with the collection of the desired reaction debris by slowing down the debris so that the kinetic energy is too low to allow implantation, or by stopping the debris from reaching the collection device entirely. Our goal is to use this primary ablation wave to our advantage, by the creation of ionized alkali metal halide salt aerosols. This technique is similar to that used by many particle accelerator groups for gas-jet transport. Ideally the salt would be ablated from a substrate, encounter the reaction debris, agglomerate, and be collected for further study. We have done studies at laser and pulsed-power facilities (Titan laser at LLNL, Trident laser at LANL, Zebra z-pinch at Nevada Terawatt Facility) evaluating the hardiness of materials for placement in the NIF target chamber, as well as testing aerosol generation by the incident x-rays generated in device shots. To test this method's potential success in the NIF environment, we have tested KCl, KI, RbI, and CsI films of 1 and 2 um linear thickness on aluminum and silicon wafer substrates in these aforementioned facilities, at varied distances. These salts do ablate in the presence of sufficient x-ray fluence. Further analysis to quantify the final ablation depth as a function of x-ray fluence is ongoing. Half of each sample was masked with a thick tungsten foil for photon opacity. KCl was the most difficult salt to ablate, from comparing the tungsten-masked side of the samples to the unmasked side of the samples. This is likely due to KCl's absorbance peak being at lower wavelengths than that of KI, {approx}160 nm vs. {approx}220 nm, respectively. Samples with and without collimation were tested to identify if any condensation of these ablated salts occurred after ablation. Visual inspection of the silicon wafer witness plates placed parallel to the direction of the incident photons showed that a vapor was deposited on the wafers next to the collimators. Further analysis with EDS in the case of the collimated samples conclusively identified the vapor as CsI. We also intend to examine samples of bare substrate exposed to the same experimental conditions for post-shot change via SEM images, optical microscopy, and atomic force microscopy (AFM). Furthermore, tests with separated isotopes may be done to reduce background contamination. When sample optimization is complete, we plan to develop a 'catcher' device for these desorbed aerosols. Current ideas include biased grids to either attract the ionized particles to the grid, or repel them towards a collection device.

36 MATERIALS SCIENCE↗

Thermal Response Testing Takes a Step Forward

Oak Ridge National Labs has independently confirmed the accuracy of a new breakthrough Advanced Thermal Response Test (TRT) method that it claims “uses less than half of the test time, allows for a fluctuating or interruptible heat flux, performs quality validation of a GHEX installation, and yields new insights into ground thermal conductivity that warrant further research.” The new Advanced TRT approach will reduce costs and, for the first time, also determine the actual thermal conductivity of grout as it is installed. As everyone in the ground source heat pump (GSHP) industry knows, assuring the quality of the grout job of a ground heat exchanger (GHEX) is an especially vexing problem. Unless one is standing at the borehole head the entire time grouting is underway, they basically have no idea how good or bad the grouting job is or even if the loop pipe itself is installed correctly. This problem has been further brought to light with formal third party grout reports confirming that grout had been poured from the surface and that many loops were shorter than the specified depth in several projects

58 GEOSCIENCES↗

Correction for Metastability in the Quantification of PID in Thin-film Module Testing: Preprint

A fundamental change in the analysis for the accelerated stress testing of thin-film modules is proposed, whereby power changes due to metastability and other effects that may occur due to the thermal history are removed from the power measurement that we obtain as a function of the applied stress factor. The power of reference modules normalized to an initial state - undergoing the same thermal and light- exposure history but without the applied stress factor such as humidity or voltage bias - is subtracted from that of the stressed modules. For better understanding and appropriate application in standardized tests, the method is demonstrated and discussed for potential-induced degradation testing in view of the parallel-occurring but unrelated physical mechanisms that can lead to confounding power changes in the module.

14 SOLAR ENERGY↗

Testing large-scale (an)isotropy of ultra-high energy cosmic rays

We present a simple yet powerful method to test models of cosmic-ray (CR) origin using the distribution of CR arrival directions. The method is statistically unambiguous in the sense that it is binless and does not invoke scanning over unknown parameters, and general in the sense that it can be applied to any model that predicts a continuous distribution of CRs over the sky. We show that it provides a powerful discrimination between an isotropic distribution and predictions from the ''matter tracer'' model, a benchmark model that assumes small CR deflections and a continuous distribution of sources tracing the distribution of matter in the Universe. Our method is competitive or superior in statistical power to existing methods, and is especially sensitive in the case of relatively few high-energy events. Applying the method to the present data we find that neither an isotropic distribution nor the matter tracer model can be excluded. Based on estimates of its statistical power, we expect that the proposed test will lead to meaningful constraints on models of CR origin with the data that will be accumulated within the next few years by the Pierre Auger Observatory and the Telescope Array.

79 ASTRONOMY AND ASTROPHYSICS↗

Apparatus and method for highly accelerated life testing of solar cells

An apparatus is provided for highly accelerated life testing (HALT) of multi-junction solar cells according to a method that utilizes a high vacuum chamber, as well as lenses and windows transparent to broad spectrum solar radiation from typically a single source to house packaged solar chips and temperature monitoring and control means during testing, thereby allowing substantially greater control of environmental variables such as temperature, atmospheric composition, and light spectrum than is currently available.

Lamarche, Paul F.↗

Comparison of heavy-ion transport simulations: Mean-field dynamics in a box

Within the transport model evaluation project (TMEP) of simulations for heavy-ion collisions, the mean-field response is examined here. Specifically, zero-sound propagation is considered for neutron-proton symmetric matter enclosed in a periodic box, at zero temperature and around normal density. The results of several transport codes belonging to two families (BUU-like and QMD-like) are compared among each other and to exact calculations. For BUU-like codes, employing the test particle method, the results depend on the combination of the number of test particles and the spread of the profile functions that weight integration over space. These parameters can be properly adapted to give a good reproduction of the analytical zero-sound features. QMD-like codes, using molecular dynamics methods, are characterized by large damping effects, attributable to the fluctuations inherent in their phase-space representation. Moreover, for a given nuclear effective interaction, they generally lead to slower density oscillations, as compared to BUU-like codes. The latter problem is mitigated in the more recent lattice formulation of some of the QMD codes. Furthermore, the significance of these results for the description of real heavy-ion collisions is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single-view phase retrieval of an extended sample by exploiting edge detection and sparsity

We propose a new approach to robustly retrieve the exit wave of an extended sample from its coherent diffraction pattern by exploiting sparsity of the sample's edges. This approach enables imaging of an extended sample with a single view, without ptychography. We introduce nonlinear optimization methods that promote sparsity, and we derive update rules to robustly recover the sample's exit wave. We test these methods on simulated samples by varying the sparsity of the edge-detected representation of the exit wave. Finally, our tests illustrate the strengths and limitations of the proposed method in imaging extended samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Comparison of Three Ways to Measure Time-Dependent Densities With Quantum Simulators

Quantum algorithms are touted as a way around some classically intractable problems such as the simulation of quantum mechanics. At the end of all quantum algorithms is a quantum measurement whereby classical data is extracted and utilized. In fact, many of the modern hybrid-classical approaches are essentially quantum measurements of states with short quantum circuit descriptions. Here, we compare and examine three methods of extracting the time-dependent one-particle probability density from a quantum simulation: direct Z -measurement, Bayesian phase estimation, and harmonic inversion. We have tested these methods in the context of the potential inversion problem of time-dependent density functional theory. Our test results suggest that direct measurement is the preferable method. We also highlight areas where the other two methods may be useful and report on tests using Rigetti's quantum virtual device. This study provides a starting point for imminent applications of quantum computing.

Yang, Jun↗

All-electron, density-functional-based method for angle-resolved tunneling ionization in the adiabatic regime

Here we develop and test a method that integrates many-electron weak-field asymptotic theory (ME-WFAT) [O. I. Tolstikhin, L. B. Madsen, and T. Morishita, Phys. Rev. A 89, 013421 (2014)] in the integral representation (IR) into the density-functional-theory (DFT) framework. In particular, we present modifications of the integral formula in the IR ME-WFAT to incorporate the potential terms unique to DFT. By solving an adiabatic rate equation for the angle-resolved ionization yield in our DFT-based ME-WFAT method, we show that the results are in excellent agreement with those of real-time time-dependent density-functional-theory (TDDFT) simulations for NO, OCS, C⁢H 3 ⁢Br, and C⁢H 3 ⁢Cl interacting with one- and two-color laser fields with a fundamental wavelength of 800 nm. This agreement is significant because the WFAT calculations take only a small fraction of the time of full TDDFT calculations. These results suggest that in the wavelength region commonly used in strong-field experiments (800 nm and longer), our DFT-based WFAT treatment can be used to rapidly screen for the ionization properties of a large number of molecules as a function of alignment or orientation between the molecule and the strong field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of electron microscopes with binary pseudo-random multilayer test samples

Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binarypseudo-random (BPR) gratings and arrays has been suggested and and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer. Here we describe the details of development of binarypseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi{sub 2}/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML testsamples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

36 MATERIALS SCIENCE↗

Characterization of Electron Microscopes with Binary Pseudo-random Multilayer Test Samples

Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested [1] and [2] and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [5]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi2/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of electron microscopes with binary pseudo-random multilayer test samples

Verification of the reliability of metrology data from high quality x-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)} and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010)]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi2/Si multilayer coating with pseudo randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize x-ray microscopes. Corresponding work with x-ray microscopes is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗