Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Wavemeter measurements of frequency stability of an injection seeded alexandrite laser for pressure and temperature lidar

The GSFC pressure-temperature lidar is a differential absorption lidar operating in the oxygen A band absorption region (760 to 770 nm), and utilizes two tunable pulsed alexandrite lasers. For obtaining temperature measurements with an accuracy of less than or = 1 K, it has been determined that the stability of the online laser frequency over a period of time corresponding to a set of measurements, 0.1 to 30 min, has to be better than +/- 0.002/cm. In addition, the requirements on laser spectral bandwidth and spectral purity are less than or = 0.02/cm and greater than or = 99.9 percent, respectively. Injection seeding with a stabilized AlGaAs diode laser was used to achieve the required frequency stability and spectral bandwidth. A high resolution Fizeau wavemeter was employed to determine the frequency stability of the pulsed alexandrite laser and determine its bandwidth, mode structure. We present the results of measurements of the frequency stability and the spectrum of the injection seeded alexandrite laser.

Prasad, C. R.↗

Temperature and Flow Measurements in Incompressible Heated Jets

An experimental study is conducted to perform time-resolved temperature and velocity measurements on a Mach 0.08 jet at total temperatures of 295 K and 353 K. Mean and rms temperature data acquired using two fine wire sensors with diameters 1.3 and 3.8 μm are compared. In order to extend the limited frequency response of the wires, the temperature data are post-processed using a frequency compensation technique available in the literature. Corresponding velocity measurements are performed at cold and heated conditions using single and parallel wire probes. Simultaneously measured temperature and velocity data obtained using the parallel wire probe are used to calculate correlations pertinent to axial turbulent heat flux. In addition to shedding some light on the aerothermal properties of heated turbulent jets, vis-`a-vis their cold counterparts, this study also provides a database for numerical prediction of these flows.

Temperature measurement, turbulence, Jets, Turbule↗

PPM/NAR 8.4-GHz noise temperature statistics for DSN 64-meter antennas, 1982-1984

From August 1982 through November 1984, X-band downlink (8.4-GHz) system noise temperature measurements were made on the DSN 64-m antennas during tracking periods. Statistics of these noise temperature values are needed by the DSN and by spacecraft mission planners to assess antenna, receiving, and telemetry system needs, present performance, and future performance. These measurements were made using the DSN Mark III precision power monitor noise-adding radiometers located at each station. It is found that for DSS 43 and DSS 63, at the 90% cumulative distribution level, equivalent zenith noise temperature values fall between those presented in the earlier (1977) and present (1983) versions of DSN/Flight Project design documents. Noise temperatures measured for DSS 14 (Goldstone) are higher than those given in existing design documents and this disagreement will be investigated as a diagnostic of possible PPM or receiving system performance problems.

Slobin, S. D.↗

Characterization of Transition Edge Sensors for the Simons Observatory

The Simons Observatory is building both large (6 m) and small (0.5 m) aperture telescopes in the Atacama Desert in Chile to observe the cosmic microwave background CMB radiation with unprecedented sensitivity. Simons Observatory telescopes in total will use over 60,000 transition edge sensor (TES) detectors spanning center frequencies between 27 and 285 GHz and operating near 100 mK. TES devices have been fabricated for the Simons Observatory by NIST, Berkeley, and HYPRES/SeeQC corporation. Iterations of these devices have been tested cryogenically in order to inform the fabrication of further devices, which will culminate in the final TES designs to be deployed in the field. The detailed design specifications have been independently iterated at each fabrication facility for particular detector frequencies. We present test results for prototype devices, with emphasis on NIST high frequency detectors. A dilution refrigerator was used to achieve the required temperatures. Measurements were taken both with 4-lead resistance measurements and with a time-domain Superconducting Quantum Interference Device (SQUID) multiplexer system. The SQUID readout measurements include analysis of current versus voltage (IV) curves at various temperatures, square wave bias step measurements, and detector noise measurements. Lastly, normal resistance, superconducting critical temperature, saturation power, thermal and natural time constants, and thermal properties of the devices are extracted from these measurements.

47 OTHER INSTRUMENTATION↗

Characterization of Rare-earth Doped Thermal Barrier Coatings for Phosphor Thermometry

Thermal Barrier Coatings have been extensively used to protect and insulate the metallic components in turbine engines from extreme environments to achieve higher turbine inlet temperatures, resulting in an increase in combined engine cycle efficiency, lowering NOx emissions and fuel consumption. Additionally, as the major failure mechanisms determining lifetime are thermally activated during engine operation, uncertainty in temperature measurements affects lifetime prediction. Early detection of Thermal Barrier Coatings spallation symptoms, associated with local delamination induced temperature changes, can reduce forced engine outages. Further improvements are envisioned with the development of more reliable measurement techniques. For this purpose, Phosphor Thermometry has been considered a promising method for precision monitoring of turbine blade coatings that contain embedded phosphor dopants. In this work, a modified four-flux Kubelka-Munk model for luminescent rare-earth doped Thermal Barrier Coating configurations supported the design and the fabrication of viable sensing coatings for potential industrial implementation. Phosphor Thermometry instrumentation was developed with the objective of expanding capabilities of the technique, using a synchronized acquisition method on sensing coatings. Experiments on an innovative Erbium-Europium co-doped Yttria-Stabilized Zirconia coating have demonstrated the effectiveness of this advanced Phosphor Thermometry instrument with enhanced sensitivity and extended temperature range. Delamination progression monitoring was achieved for the first time using a Thermal Barrier Coating configuration subjected to indentation that includes a thin luminescent layer deposited on the surface and associating the multi-layer configuration with a predictive model that evaluates the advancement of the degradation of the coatings. To further ensure the integrity of the phosphor doped coatings, synchrotron X-ray diffraction was performed to characterize the specific residual strains and thermal expansion of the materials, determining mechanical robustness and compatibility with state-of-the-art Thermal Barrier Coatings. The outcomes of this work pave the way for in-situ temperature measurements on phosphor-doped turbine blade coatings with increased performance and accuracy.

Fouliard, Quentin↗

Comparative analysis of the sensitivity of nanometallic thin film thermometers

Thin film platinum resistive thermometers are conventionally applied for resistance thermometry techniques due to their stability and proven measurement accuracy. Depending upon the required thermometer thickness and temperature measurement, however, performance benefits can be realized through the application of alternative nanometallic thin films. Herein, a comparative experimental analysis is provided on the performance of nanometallic thin film thermometers most relevant to microelectronics and thermal sensing applications: Al, Au, Cu, and Pt. Sensitivity is assessed through the temperature coefficient of resistance, measured over a range of 10–300 K for thicknesses nominally spanning 25–200 nm. In this work, the interplay of electron scattering sources, which give rise to the temperature-dependent TCR properties for each metal, are analyzed in the framework of a Mayadas–Shatzkes based model. Despite the prevalence of evaporated Pt thin film thermometers, Au and Cu films fabricated in a similar manner may provide enhanced sensitivity depending upon thickness. These results may serve as a guide as the movement toward smaller measurement platforms necessitates the use of smaller, thinner metallic resistance thermometers.

36 MATERIALS SCIENCE↗

Temperature and pressure measurement techniques for an advanced turbine test facility

A high pressure, high-temperature turbine test facility is being constructed at the NASA Lewis Research Center for use in turbine cooling research. Several recently developed temperature and pressure measuring techniques will be used in this facility. This paper describes these measurement techniques, their status, previous applications and some results. Noncontact surface temperature measurements will be made by optical methods. Radiation pyrometry principles combined with photoelectric scanning will be used for rotating components and infrared photography for stationary components. Contact (direct) temperature and pressure measurements on rotating components will be handled with an 80-channel rotary data package which mounts on and rotates with the turbine shaft at speeds up to 17,500 rpm. The data channels are time-division multiplexed and converted to digital words in the data package. A rotary transformer couples power and digital data to and from the shaft.

Pollack, F. G.↗

Microwave radiometer measurement of water vapor path delay: Data reduction techniques

Data reduction techniques are developed to compensate for water vapor path delay, a limiting error source in geodetic measurements made with very long baseline interferometry and in radio ranging to spacecraft. It is shown that water vapor path delay is proportional to a linear combination of saturation-corrected sky brightness temperatures, measured on and off the water vapor line. The effects of emission from liquid water droplets in clouds as well as most of the oxygen emission are removed by the off-line channel. Sky brightness temperatures are saturation-corrected or 'linearized' using estimates of effective sky temperatures made from surface temperature. Tipping curves are used to remove instrumental error. Coefficients are found by two methods: from a regression analysis of measured brightness temperatures versus radiosonde measured delay, and from a regression analysis of theoretical brightness temperatures versus radiosonde measured delay. In each case the coefficients are adjusted for differing climatic conditions by measurements of surface temperature, pressure, and relative humidity. Regression solutions are constrained to remove liquid water contributions and to give the correct slope for radiometer versus radiosonde path delay.

Claflin, E. S.↗

Accounting For Nonlinearity In A Microwave Radiometer

Simple mathematical technique found to account adequately for nonlinear component of response of microwave radiometer. Five prescribed temperatures measured to obtain quadratic calibration curve. Temperature assumed to vary quadratically with reading. Concept not limited to radiometric application; applicable to other measuring systems in which relationships between quantities to be determined and readings of instruments differ slightly from linearity.

Stelzried, Charles T.↗

Temperature and pressure measurement techniques for an advanced turbine test facility

A high pressure, high-temperature turbine test facility constructed for use in turbine cooling research is described. Several recently developed temperature and pressure measuring techniques are used in this facility. The measurement techniques, their status, previous applications and some results are discussed. Noncontact surface temperature measurements are made by optical methods. Radiation pyrometry principles combined with photoelectric scanning are used for rotating components and infrared photography for stationary components. Contact (direct) temperature and pressure measurements on rotating components are expected to be handled with an 80 channel rotary data package which mounts on and rotates with the turbine shaft at speeds up to 17,500 rpm. The data channels are time-division multiplexed and converted to digital words in the data package. A rotary transformer couples power and digital data to and from the shaft.

Pollack, F. G.↗

An Experimental Study of Ignition Effects and Flame Growth Over a Thin Solid Fuel in Low-Speed Concurrent Flow Using Drop-Tower Facilities

An experimental study of ignition and flame growth over a thin solid fuel in oxidizer flow speeds from 0 to 10 cm/sec concurrent flow was performed. This study examined the differences between ignition using a resistively heated wire (woven in a sawtooth pattern over the leading edge of the fuel), and a straight resistively heated wire augmented by a chemical ignitor doped onto the leading edge of the fuel. Results showed that the chemical system yielded non-uniform ignition bursts, while the system using only the hotwire gave more uniform ignition. At speeds up to 2.5 cm/sec, the chemical system yielded non-uniform pyrolysis fronts, while the hotwire system gave more uniform pyrolysis fronts. At speeds of 5 cm/sec or greater, both systems gave uniform pyrolysis fronts. The chemically-ignited flames tended to become too dim to see faster than the hotwire-ignited flames, and the flame lengths were observed to be shorter (after the initial burst subsided) for the chemical system for all speeds. Flame and pyrolysis element velocities were measured. Temperature profiles for selected tests were measured using thermocouples at the fuel surface and in the gas phase. Comparisons between the flame element velocities and peak temperatures recorded in these tests with calculated spread rates and peak temperatures from a steady-state model are presented. Agreement was found to be within 20% for most flame elements for nominal velocities of 5 cm/sec and 7.5 cm/sec.

Pettegrew, Richard Dale↗

Investigation of the flow in the diffuser section of the NASA Lewis icing research tunnel

The flow in the diffuser section of the Icing Research Wind Tunnel at NASA Lewis Research Center is investigated using both tunnel calibration measurements and numerical simulation techniques. Local pressure and temperature measurements are made to establish velocity and temperature profiles in the diffuser of the tunnel. These profiles are compared with similar measurements made prior to renovating the equipment which generates the tunnel's icing cloud. This comparison indicates the manner in which this change affected the flow. The measured data were also compared with a numerical simulation of the flow to help understand how such changes may favorably alter the tunnel flow.

Addy, Harold E., Jr.↗

Investigation of the flow in the diffuser section of the NASA Lewis Icing Research Tunnel

The flow in the diffuser section of the Icing Research Wind Tunnel at NASA Lewis Research Center is investigated using both tunnel calibration measurements and numerical simulation techniques. Local pressure and temperature measurements are made to establish velocity and temperature profiles in the diffuser of the tunnel. These profiles are compared with similar measurements made prior to renovating the equipment which generates the tunnel's icing cloud. This comparison indicates the manner in which this change affected the flow. The measured data were also compared with a numerical simulation of the flow to help understand how such changes may favorably alter the tunnel flow.

Addy, Harold E., Jr.↗

Temperature Sensors Based on WGM Optical Resonators

A proposed technique for measuring temperature would exploit differences between the temperature dependences of the frequencies of two different electromagnetic modes of a whispering gallery-mode (WGM) optical resonator. An apparatus based on this technique was originally intended to be part of a control system for stabilizing a laser frequency in the face of temperature fluctuations. When suitably calibrated, apparatuses based on this technique could also serve as precise temperature sensors for purposes other than stabilization of lasers. A sensor according to the proposal would include (1) a transparent WGM dielectric resonator having at least two different sets of modes characterized by different thermo-optical constants and (2) optoelectronic instrumentation for measuring the difference between the temperature-dependent shifts of the resonance frequencies of the two sets of modes.

Savchenkov, Anatoliy↗