Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

A New Method for Grain Texture Manipulation in Post-Deposition Niobium Films

Niobium films are frequently grown using forms of energetic condensation, with modest substrate temperatures to control grain structure. As an alternative, energetic deposition onto a cold substrate results in a dense amorphous film, with a much larger energy density than the re-crystallized state. Re-crystallization is then performed using a pulsed UV (HIPPO) laser, with minimal damage to the substrate. In addition, a graded interface between the substrate and Nb film is created during the early stages of energetic deposition. Experimental approach and apparatus are described.

Musson, J.↗

Idling - cruising the fuel inefficiency highway.

What is the purpose of idling? The scale of idling can be small, as when parents idle their vehicles while waiting for their children outside of school, or it can be large, as when ocean liners are in port. In many cases, the primary purpose for idling is to control the temperature of a passenger or freight compartment. Large line-haul trucks idle overnight to keep fuel and the engine warm, for the resting driver's comfort, to mask out noises and smells, and for safety. In addition, all classes of trucks idle during the workday at ports and terminals, busy delivery sites, border crossings, and other work sites. They may be idling to enable slow movement in a queue (creep idling) or to provide other services. Bus drivers also idle their vehicles while they wait for passengers and to warm up in the morning. Even locomotive engines are idled so they start, for hotel load, to keep the battery charged, to keep the toilet water from freezing, and for air brakes, or because the operator idles out of habit. Although this document focuses on long-haul trucks, much of the information applies to other vehicles as well. The impacts of idling are substantial, with as much as 6 billion gallons of fuel burned unnecessarily each year in the United States at a cost of over $20 billion. The extra hours of engine operation also cost the owners money for more frequent maintenance and overhauls. In addition, idling vehicles emit particulates (PM{sub 10}), nitrogen dioxide (NO{sub 2}), carbon monoxide (CO), and carbon dioxide (CO{sub 2}). These emissions, along with noise from idling vehicles, have led to many local and state restrictions on idling. Two main factors have combined to create a surge of interest in idling reduction (IR): (1) Increasing restrictions on idling for heavy vehicles and (2) The price of diesel fuel. Because stakeholders focus their efforts on improving different factors (air quality, fuel economy, noise level), they do not necessarily agree on the most advantageous technological alternatives to implement. In addition, although many equipment manufacturers have tried to educate customers and government agencies, they often provide conflicting claims about the comparative merits of different devices. This makes it difficult for truck owners to choose the right equipment for their needs. In this study, we present the first comparison of IR technologies with each other and with idling on the basis of both costs and full fuel-cycle emissions, for different locations, fuel prices, and idling patterns. The preferences described are for the technologies that reduce total emissions the most and cost truck owners the least. We also discuss how regulatory issues and legislation affect IR, what financial incentives help to promote IR, and how outreach and education approaches can be adopted to reduce the need to idle. Finally, we offer a prediction of how future research and development (R&D), regulations, and citizen involvement can help to improve fuel economy and clean the air.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first cost of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first cost of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.

15 GEOTHERMAL ENERGY↗

Coastal Ohio Wind Project for Reduced Barriers to Deployment of Offshore Wind Energy

The Coastal Ohio Wind Project was created to establish the viability of wind turbines on the coastal and offshore regions of Northern Ohio. The project’s main goal was to improve operational unit strategies used for environmental impact assessment of offshore turbines on lake wildlife by optimizing and fusing data from the multi-instrument surveillance system and providing an engineering analysis of potential design/operational alternatives for offshore wind turbines. The project also developed a general economic model for offshore WTG deployment to quantify potential revenue losses due to wind turbine shutdown related to ice and avian issues. In a previous phase of this project (Award Number: DE-FG36-06GO86096), we developed a surveillance system that was used to collect different parameters such as passage rates, flight paths, flight directions, and flight altitudes of nocturnal migrating species, movements of birds and bats, and bird calls for assessing patterns and peak passage rates during migration. To derive such parameters we used thermal IR imaging cameras, acoustic recorders, and marine radar Furuno (XANK250), which was coupled with a XIR3000B digitizing card from Russell Technologies and open source radR processing software. The integration yielded a development of different computational techniques and methods, which we further developed and optimized as a combined surveillance system. To accomplish this task we implemented marine radar calibration, optimization of processing parameters, and fusion of the multi-sensor data in order to make inferences about the potential avian targets. The main goal of the data fusion from the multi-sensor environment was aimed at reduction of uncertainties while providing acceptable confidence levels with detailed information about the migration patterns. Another component comprised of an assessment of wind resources in a near lake environment and an investigation of the effectiveness of ice coating materials to mitigate adverse effects of ice formation on wind turbine structures. Firstly, a Zephir LiDAR system was acquired and installed at Woodlands School in Huron, Ohio, which is located near Lake Erie. Wind resource data were obtained at ten measurement heights, 200m, 150m, 100m, 80m, 60m, 40m, 38m, 30m, 20m, and 10m. The Woodlands School’s wind turbine anemometer also measured the wind speed at the hub height. These data were collected for approximately one year. The hub anemometer data correlated well with the LiDAR wind speed measurements at the same height. The data also showed that on several days different power levels were recorded by the turbine at the same wind speed as indicated by the hub anemometer. The corresponding LiDAR data showed that this difference can be attributed to variability in the wind over the turbine rotor swept area, which the hub anemometer could not detect. The observation suggests that single point hub wind velocity measurements are inadequate to accurately estimate the power generated by a turbine at all times since the hub wind speed is not a good indicator of the wind speed over the turbine rotor swept area when winds are changing rapidly. To assess the effectiveness of ice coatings to mitigate the impact of ice on turbine structures, a closed-loop icing research tunnel (IRT) was designed and constructed. By controlling the temperature, air speed, water content and liquid droplet size, the tunnel enabled consistent and repeatable ice accretion under a variety of conditions with temperatures between approximately 0°C and -20°C and wind speeds up to 40 miles per hour in the tunnel’s test section. The tunnel’s cooling unit maintained the tunnel temperature within ±0.2°C. The coatings evaluated in the study were Boyd Coatings Research Company’s CRC6040R3, MicroPhase Coatings Inc.’s PhaseBreak TP, ESL and Flex coatings. Similar overall performance was observed in all coatings tested in that water droplets form on the test articles beginning at the stagnation region and spreading in the downstream direction in time. When comparing ice accumulation characteristics for the four coatings tested, for ice thickness during accumulation the CRC6040R3 had the least, followed by the ESL, Flex, and TP. However, when comparing the coatings’ ability to reduce ice adhesion, the Flex showed the highest adhesion reduction, followed by the ESL, TP and CRC 6040R3 coatings. The ice accumulated on the Flex coated surface shed under gravity when rotated 90 degrees following the tests while the other coatings required application of varying degrees of force to remove the ice. In conclusion, the ice coatings tested were not sufficient in preventing ice accumulation on all surfaces. However, Flex coating shows promise in mitigating ice on the rotor blades under the gravitational and centrifugal forces. Only the effect of gravity in shedding the ice was considered in this study. Further research will be needed to evaluate this coating on rotating blades in the icing tunnel to characterize its effectiveness. Lastly, the development of economic feasibility models used existing approaches adapted for offshore deployment in marine settings to one more suitable for Lake Erie deployment. Two different wind turbine models were tested and dynamic return on investment (ROI) model scenarios were generated. For the purpose of estimating power generation three bladed wind turbines of 3 MW capacity were selected including Model1- Leitwind LTW101-3.000-kW and Model2-Vostro V90-3.0 MW. The analysis were based on the revenue aspect of decision making of deploying wind turbines in the Ohio coastal region. The installation cost, maintenance and operational aspects were disregarded due to unavailability of data. The adjusted varying price (residential and industrial sector) and projected future price of electricity in different years suggested that the Leitwind model could generate $\$ $32.4 million of revenue in 25 years if the supply electricity is in the residential sector, while it would be $\$ $14.7million if the supply is in the industrial sector. For the Vostro model these figures are $\$ $28.6 million for residential sector and $\$ $12.9 million for industrial sector for 25 years.

17 WIND ENERGY↗

Supplemental Cooling for Nitrate Salt Waste

In July 2015, Los Alamos National Laboratory completed installation of a supplemental cooling system in the structure where remediated nitrate salt waste drums are stored. Although the waste currently is in a safe configuration and is monitored daily,controlling the temperature inside the structure adds another layer of protection for workers, the public,and the environment.This effort is among several layers of precautions designed to secure the waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermostatic Radiator Valve Evaluation

A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market. In this project, the ARIES team sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt™ (Building Energy Optimization software).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ensemble of Thermostatically Controlled Loads: Statistical Physics Approach

Thermostatically Controlled Loads (TCL), e.g. air-conditioners and heaters, are by far the most wide-spread consumers of electricity. Normally the devices are calibrated to provide the so-called bang-bang control of temperature - changing from on to off , and vice versa, depending on temperature. Aggregation of a large group of similar devices into a statistical ensemble is considered, where the devices operate following the same dynamics subject to stochastic perturbations and randomized, Poisson on/off switching policy. We analyze, using theoretical and computational tools of statistical physics, how the ensemble relaxes to a stationary distribution and establish relation between the re- laxation and statistics of the probability flux, associated with devices' cycling in the mixed (discrete, switch on/off , and continuous, temperature) phase space. This allowed us to derive and analyze spec- trum of the non-equilibrium (detailed balance broken) statistical system. and uncover how switching policy affects oscillatory trend and speed of the relaxation. Relaxation of the ensemble is of a practical interest because it describes how the ensemble recovers from significant perturbations, e.g. forceful temporary switching o aimed at utilizing flexibility of the ensemble in providing "demand response" services relieving consumption temporarily to balance larger power grid. We discuss how the statistical analysis can guide further development of the emerging demand response technology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

M3FT-16OR0203052-Test Design for FeCrAl Alloy Tube Irradiation in HFIR

This calculation summarizes thermal analyses of a flexible rabbit design for irradiating a variety of pressurized water reactor (PWR) cladding materials (stainless steel, iron-chromium aluminum [FeCrAl], Zircaloy, and Inconel) with variable dimensions at a temperature of 350 °C in the flux trap of the High Flux Isotope Reactor (HFIR). The design can accommodate standard cladding for outer diameters (ODs) of approximately 9.50 mm with thickness ranging from 0.30 mm to 0.70 mm. The length is generally between 10 and 50 mm. The specimens contain moly inserts with a variable OD that provides the heat flux necessary to achieve the design temperature with such a small fixed gas gap. The primary outer containment is an Al-6061 housing with a slightly enlarged inner diameter (ID) of 9.60 mm. The specimen temperature is controlled by determining a helium/argon gas mixture specific to the as-built specimen and housing. Variables that affect the required gas mixture are the cladding material (thermal expansion, density, heat generation rate), cladding OD, housing ID, and cladding ID. This calculation documents the analyses performed to determine required gas mixtures for a variety of scenarios.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiation Tolerance of Controlled Fusion Welds in High Temperature Oxidation Resistant FeCrAl Alloys

High temperature oxidation resistant iron-chromium-aluminum (FeCrAl) alloys are candidate alloys for nuclear applications due to their exceptional performance during off-normal conditions such as a loss-of-coolant accident (LOCA) compared to currently deployed zirconium-based claddings [1]. A series of studies have been completed to determine the weldability of the FeCrAl alloy class and investigate the weldment performance in the as-received (non-irradiated) state [2,3]. These initial studies have shown the general effects of composition and microstructure on the weldability of FeCrAl alloys. Given this, limited details on the radiation tolerance of FeCrAl alloys and their weldments exist. Here, the highest priority candidate FeCrAl alloys and their weldments have been investigated after irradiation to enable a better understanding of FeCrAl alloy weldment performance within a high-intensity neutron field. The alloys examined include C35M (Fe-13%Cr-5% Al) and variants with aluminum (+2%) or titanium carbide (+1%) additions. Two different sub-sized tensile geometries, SS-J type and SS-2E (or SS-mini), were neutron irradiated in the High Flux Isotope Reactor to 1.8-1.9 displacements per atom (dpa) in the temperature range of 195°C to 559°C. Post irradiation examination of the candidate alloys was completed and included uniaxial tensile tests coupled with digital image correlation (DIC), scanning electron microscopy-electron back scattered diffraction analysis (SEM-EBSD), and SEM-based fractography. In addition to weldment testing, non-welded parent material was examined as a direct comparison between welded and non-welded specimen performance. Both welded and non-welded specimens showed a high degree of radiation-induced hardening near irradiation temperatures of 200°C, moderate radiation-induced hardening near temperatures of 360°C, and almost no radiation-induced hardening at elevated temperatures near 550°C. Additionally, low-temperature irradiations showed the non-welded specimens to exhibit strain-induced softening (decrease in the true stress level) with increasing plastic strain during tensile testing. Fracture for the weldments was found to occur exclusively within the fusion zone. The mechanical performance of the weldment was speculated to be directly linked to variances in the radiation-induced microstructure including the formation of dislocation loops and precipitation of the Cr-rich α' phase. The localized microstructural variation within the weldments, including grain size, was determined to play a significant role in the radiation-induced microstructure. The results summarized within highlight the need for additional data on the radiation tolerance of weldments as the mechanical performance of the fusion zone was shown to be the limiting factor in the overall performance of the weldments.

36 MATERIALS SCIENCE↗

Mechanical Behavior of UO 2 at Sub-grain Length Scales: Quantification of Elastic, Plastic and Creep Properties via Microscale Testing

Techniques were developed to measure properties at sub-grain scales using depleted Uranium Oxide (d-UO2) samples heat-treated to obtain different grain sizes and oxygen stoichiometries, through three main tasks: 1) sample processing and characterization, 2) microscale and conventional testing and 3) modeling. Grain size and crystallography were characterized using Scanning Electron Microscopy (SEM), in conjunction with Electron Backscattering Diffraction (EBSD) and Electron Channeling Contrast Imaging (ECCI). Grains were then carefully selected based on their crystallographic orientations to perform ex-situ micromechanical tests with samples machined via Focused Ion Beam (FIB), with emphasis on micro-cantilever bending. These experiments were performed under controlled atmospheres, to insure stoichiometry control, at temperatures up to 700 °C and allowed measurements involving elastic (effective Young’s modulus), plastic (critical resolved shear stresses) and creep (creep strain rates) behavior. Conventional compression experiments were performed simultaneously to compare with the ex-situ measurements and study potential size effects. Modeling was implemented using anisotropic elasticity and inelastic constitutive relations for plasticity and creep based on kinematics and kinetics of dislocation glide that account for the effects of crystal orientation, and stress. The models will be calibrated and validated using the experimental data. This project provided insight on correlations among stoichiometry, crystallography and mechanical behavior in advanced oxide fuels, provided valuable experimental data to validate and calibrate mesoscale fuel performance codes and also a framework to measure sub-grain scale mechanical properties that should be suitable for use with irradiated samples due to small volumes required. The goals and metrics of the ongoing study of thermo-mechanical behavior in depleted uranium dioxide (d-UO 2 ) outlined in this project have been concluded successfully, resulting in: 1) the successful fabrication, processing, and characterization of large-grained samples with various orientations (up to and including single crystals) having stoichiometric and hyper-stoichiometric O/U ratios; 2) formulation, calibration, and validation of a crystal plasticity constitutive model to describe the creep deformation of UO 2 at the sub-grain length scale (single crystal level) at intermediate temperatures; 3) the successful calibration of a crystal plasticity constitutive model to describe the elasto-plastic deformation of microcantilever beams, also at moderate temperatures. Samples were prepared from natural uranium oxide powder of production-quality provided by Areva. The powder was pressed in a die to a pressure of 100 MPa to produce green pellets with no sintering aids, lubricants, or any other additives. The green pellets were then heated up to 1700 °C under ultra-high purity argon atmosphere (~1 ppm O2). The atmosphere was then changed to 79% Argon, 21% O 2 and the temperature was held at 1700 °C for 2 hours to sinter the pellets under oxidative conditions [1] that are known to increase grain growth kinetics in UO 2 [2]. Samples were then cooled down under Ar-4%H2 atmosphere to reduce the samples back to stoichiometric UO 2 . For macro-scale procedures, testing of UO 2 samples with large grains was performed at 1200 °C using a modified load frame capable of applying dead-weight loads to ensure constant stress conditions, while displacement of the sample produced by the applied load was measured with high precision micrometers to obtain strains. Stress steps were used during testing and the strains were monitored to measured creep strain rates under steady state for each level of stress used, so that stress exponents could be obtained. The results of the mechanical testing, along with sample geometry and crystal orientation of the grains in the samples, as well as post-test sample characterization were used to formulate a viscoplastic model to account for steady state (stage II) creep behavior, along with basic assumptions from crystal plasticity and kinematic constraints due to testing fixtures. In the micro-scale, testing of microcantilever beams at temperatures ranging from 25 to 570 °C was performed in-situ with a scanning electron microscope with a special attachment to apply load and measure displacement while the samples were at temperature. The load-displacement curves obtained showed linear behavior before fracture for all temperatures attempted except 570 °C, where clear deviations from non-linearity were observed before fracture. These deviations were consistently observed for all samples tested for a given orientation. A viscoplastic model was used to account for the presence of inelastic strain, along with basic assumptions from crystal plasticity and beam theory. These models were kept as simple as possible, and results from tests performed in a set of samples with a given crystal orientation were used to calibrate the material constants for the model, while results from a different sample set were then used for validation, thus satisfying the conditions of all main tasks within the parameters of this project. Details of these efforts are outlined in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Combined microscopy studies of complex electronic materials. Final report

The aim of this project was to study the electronic properties of exotic electronic materials which are only available as micron-scale samples or have microscopic inhomogeneity, using a special combination of multiple submicron scanning microscopy techniques allied to control of temperature, magnetic and electric fields and mechanical strain. In nanobeams of VO 2 , with its still mysterious metal-insulator phase transition, we determined the phase diagram and demonstrated that hydrogen diffusion is strongly channelled along one crystal axis. Using graphene, we developed and applied the scanning photo-Nernst effect, in which a current is generated when a laser is focused on the edge a sample in a magnetic field. We demonstrated that CrI 3 , a two-dimensional layered magnet, retains true Ising ferromagnetization down the monolayer level due to its out-of-plane anisotropy. In exfoliated WTe 2 , a layered topological semimetal, we discovered that monolayers are the first monolayer topological insulator and we imaged the helical edge states with scanning microwave microscopy. We also discovered that the same material when stacked in a few layers is a ferroelectric metal, and that the monolayer can be converted to a superconducting state by electron doping with a gate a temperatures below 1 K. Additionally, we developed the capability to perform momentum-resolved electronic spectroscopy on operating nanoscale devices by applying micron-scale angle resolved photoemission spectroscopy to two-dimensional heterostructure devices incorporating graphene and transition metal dichalcogenide semiconductors. Using it, we measured the band gaps of a series of monolayer semiconductors and observed band renormalization as a function of electron doping in monolayer WSe 2 .

36 MATERIALS SCIENCE↗

Multifactor Experiment and Model Integration to Determine the Regional Vulnerability of Permafrost Carbon to Climate Change. Final report

The major research goal of this project was to understand and quantify the fate of carbon stored in permafrost ecosystems using a combination of field and laboratory experiments to measure and model isotope ratios and carbon fluxes in a tundra ecosystem exposed to experimental warming. Field measurements centered on a two-factor experimental warming to increase air and soil temperatures alone, and in combination, at a tundra field site in Alaska. A second manipulation of water table was embedded within the warming treatment such that both major environmental factors (temperature, moisture) controlling ecosystem carbon dynamics were experimentally altered. The experiment was interfaced with modeling activities using both data assimilation and forward modeling approaches. Models were used to make forecasts of ecosystem carbon dynamics beyond the time frame and environmental space of the experiment itself. These results were linked with ongoing synthesis and model intercomparison activities through the Permafrost Carbon Network, which led to additional synthesis publications as a result of collaboration and data sharing from this project. As key outcomes, this project has produced new papers published in the peer-reviewed literature, archived datasets used for model-data intercomparisons, trained graduate students and postdoctoral researchers, and has raised awareness about the vulnerability of permafrost carbon to a wider audience.

54 ENVIRONMENTAL SCIENCES↗

Energy Intensity Baselining and Tracking Guidance

Each company joining the U.S. Department of Energy’s (DOE’s) Better Buildings, Better Plants Program (Better Plants) commits to establishing an energy consumption and energy intensity (EI) baseline and to tracking its energy performance over a 10-year period against that baseline. The baseline must reflect a company’s energy consumption over a 12-month period, covering all its U.S.-based operations. Energy consumption is calculated by fuel type in terms of primary energy (also known as source energy). EI is broadly defined as the amount of energy consumed per unit of output produced. For this guidance document and for the program, the term energy performance represents an evaluation of a facility’s capacity to use energy efficiently. Metrics used to assess a facility’s energy performance can include EI, energy consumption, improvements in EI, etc. Establishing an energy baseline and tracking system is a critical first step in effectively managing energy use. Developing a baseline can help a company understand energy use within the corporation and give it a point of comparison to evaluate future efforts to improve energy performance. It can also support efforts to validate a company’s energy management activities, improve comparative analyses when using benchmarks, and help in predicting future energy needs. In addition, a company that normalizes its performance data can determine highly defensible measures of energy savings generated through implemented energy efficiency projects. Establishing a baseline and tracking energy performance is also a requirement for ISO 50001 certification. Although basic energy data can be collected through utility bills, most manufacturers will have to perform additional analyses to develop accurate and robust energy baselines and tracking systems. Energy is consumed in many ways within the manufacturing sector and can come from multiple sources. Energy is sometimes generated and sold to other parties or captured and reused on-site. External events can exert a significant impact on a facility or company’s energy use independent of any purposeful efforts to improve energy efficiency. Operational changes, such as production shifts—which may be inevitable for some companies over the 10-year period covered by the program—can also make a big difference in energy use. Since Better Plants asks companies to account for all their U.S.-based operations, mergers, acquisitions, and divestitures can also have significant implications for a company’s energy metrics. This document aims to demystify the sometimes complex baselining process. It devotes special attention to the task of normalizing and adjusting energy consumption to account for external factors, such as weather and production changes. A key recommendation is that companies use regression analysis to normalize their energy consumption data whenever possible. Regression analysis is a statistical technique that estimates the dependence of a variable (i.e., energy use in the context of Better Plants) on one or more independent variables such as ambient temperature, while controlling for the influence of other variables at the same time. A properly developed regression analysis can provide a reliable estimate of energy savings resulting from energy improvement strategies and projects by accounting for the effects of variables such as annual production levels and weather. DOE has developed a companion Energy Performance Indicator software tool (EnPI) to simplify the baselining process. This tool can run regression models, calculate changes in EI at the facility level, and automatically compile facility-level data into a corporate-wide metric. Note that although the relevant equations used to calculate EI are provided in this document, the EnPI tool will automatically perform most calculations for the user. Additionally, Better Plants Partners (Partners) can call on their Technical Account Manager (TAM) to help them establish a baseline and assist with the necessary calculations to track progress.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Earth Source Heat: A Cascaded Systems Approach to DDU of Geothermal Energy on the Cornell Campus

This report documents the completion of the DOE study DE-EE0008103: Earth Source Heat: A Cascaded Systems Approach to DDU of Geothermal Energy on the Cornell Campus. This study involved a comprehensive evaluation of the potential for Earth Source Heat (ESH), Cornell’s specific application of Deep Direct Use (DDU) geothermal energy, to create a viable renewable source of thermal energy for its Ithaca, NY campus district heating system. The study included stochastic modeling that married each of two potential subsurface resources (two specific geological reservoirs) to documented campus heating operations based on hourly campus heating profiles and proposed integrated equipment controls (variable speed pumps and heat pumps). The outputs of the subsurface modeling were used as inputs for a Cornell-developed surface heat use Excel-based modeling program (the program was named “Modeled ENergy Use”, or “MEnU”). This allowed Cornell to compute realistic annual totals of extractable and useable heat for the campus, including details like heat losses, minimum summer demand, and controllable building temperature settings. The Cornell team then evaluated the costs and benefits of each modeled scenario. The primary evaluation was a standard “single bottom line” economic calculation for the Levelized Cost of Heat (LCOH). This represents the annualized cost (per unit heat) for Cornell. Additional valuations were also computed based on the benefit to the environment and to the regional economy (i.e., economic benefits external to campus). The results of this study demonstrate that if suitable reservoir flow can be attained, Earth Source Heat would be a viable technology to supply Cornell’s district heating system. This viability is based on the following criteria: (1) The modeled system produced a total useable heat output that exceeded the minimum annual campus heat load determined at the onset of the project (i.e., offsetting at least 20% of the annual campus thermal load). The output range is substantial depending on both the subsurface resource and the surface applications; at the high end, our modeled solutions produced up to ~70% of existing campus heat load with a single well pair producing 70 kg/s with integrated high-temperature heat pumps, and (2) Modeling demonstrated that multiple geothermal reservoirs could provide economically viable results when heat pumps were strategically integrated, a design that has been proven in at least one European installation already. In this context, “economically viable” means that the LCOH for the project is less than the regional commercial price of heat that would be generated using natural gas (the most common and cheapest fossil alternative in our area). Based on a single-bottom-line (LCOH) valuation, our results show that economic success is likely for any reservoir deeper than about 2.25 km where a sufficient permeability exists (or can be created with stimulation or similar engineering enhancement) and reasonable production temperatures sustained over time. The LCOH values of $\$ 4.77$ to $\$ 6.46$ per MMBtu are all lower than the comparable cost of providing heat energy with a natural gas boiler for a facility in the Northeast U.S. that obtains natural gas at commercial rates (Commercial heat costs would include at least $\$ 9.41$ in fuel costs, representing total boiler/transfer efficiency of 85% using gas at $\$ 8.00$ per MMBtu; LCOH would be higher if capital equipment and other operating costs were included). In addition to LCOH, Cornell’s scope also included evaluation of the Environmental value and Regional Economic value of each scenario. When considering the environmental and regional economic value of such a project, the overall “triple bottom line” cost (i.e., the LCOH less the LCOH ENV and LCOH REG values) is even lower and in some cases negative; i.e., in some cases a project achieving the listed performance would have higher value to the environment and to the regional economy than the total project costs over the 30-year project timeframe.

15 GEOTHERMAL ENERGY↗

Updated Reference VTR Core for CD-1

A preliminary reference core design was previously developed for the Versatile Test Reactor. The main features are that it is a 300 MW th sodium-cooled fast reactor using ternary metallic fuel U-20Pu-10Zr and able to achieve peak fast fluxes (E n > 0.1 MeV) in excess of 4.0x10 15 n/cm 2 -s. The plutonium in the fuel was assumed to be “reactor grade”, with a fissile quality of about 72% (i.e., 239 Pu and 241 Pu comprise 72% of the plutonium isotopes), and the uranium was assumed to be low-enriched uranium with 5% 235 U. This preliminary core design has been used through the CD-0 phase of the VTR project. Progression of the work after CD-0 led to revising, updating and refining the reference VTR core design, based on considerations from the various VTR teams: fuel, experiment, safety, and plant design teams. The objective of this report is to summarize the various changes made and details added to the model, to provide a description of the updated reference VTR core design and of its performance characteristics. This includes the traditional reactor physics characteristics, fuel cycle details, reactivity coefficients, temperature distributions, control rod worths and shutdown requirements. All of these define the updated “reference VTR core” intended to be used through CD-1.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Final Technical Report: Innovative Magnetron Power Sources for Superconducting RF (SRF) Accelerators

In this project, MUONS is designing and building custom magnetrons at Richardson Electronics (RELL) to test the predictions of the models and make improvements to the designs to match the needs of NP SRF accelerators and their life-cycle costs. To increase lifetime, the filament temperature is controlled by a feedback circuit that includes a model of back streaming of electrons. The gain of the magnetron is optimized by the design of an input port. A permanent magnet design with trim coil for amplitude adjustment reduces energy consumption. Moving the construction of the magnetron from prototype to manufacturing includes the utilization of RELL processes and designs. To the extent that outgassing of materials influences the lifetime of the magnetron, methods for minimizing outgassing was explored. Further experimentation of the potential of sub-critical voltage operation continues to be explored. The commercialization goal of the project will be naturally achieved as RELL already has world-wide marketing, sales, and support to exploit the assembly-line capabilities generated by this project to enable magnetron technologies for NP accelerators.

43 PARTICLE ACCELERATORS↗